Allied AM40-331K-RC Axial molded inductor Datasheet

RoHS
Axial Molded Inductors
Allied
Part
Number
AM40-271K-RC
22AWG
1.15
NOMINAL
(29)
1.15
NOMINAL
(29)
0.44±0.01
Inductance Tolerance
(µh)
(%)
AM40
Q
Min.
Test
Freq.
(MHz)
SRF
Min.
(MHz)
DCR
Max.
(Ω )
Rated
Current
(mA)
8.2
126
270
10
65
0.79
5.6
AM40-301K-RC
300
10
65
0.79
5.3
8.7
122
AM40-331K-RC
330
10
65
0.79
5.0
9.1
120
AM40-361K-RC
360
10
65
0.79
4.7
9.6
115
AM40-391K-RC
390
10
65
0.79
4.5
10.0
114
AM40-431K-RC
430
10
65
0.79
4.3
10.6
111
AM40-471K-RC
470
10
65
0.79
4.0
11.0
108
AM40-501K-RC
500
10
65
0.79
3.7
11.3
106
AM40-551K-RC
510
10
65
0.79
3.8
11.6
105
AM40-561K-RC
560
10
65
0.79
3.6
12.3
104
AM40-621K-RC
620
10
60
0.79
3.5
13.0
101
AM40-681K-RC
680
10
60
0.79
3.4
13.7
97
AM40-751K-RC
750
10
60
0.79
3.3
14.4
95
AM40-821K-RC
820
10
60
0.79
3.1
15.1
92
AM40-911K-RC
910
10
60
0.79
2.9
15.8
91
AM40-102K-RC
1000
10
60
0.79
2.8
16.5
88
(11.18±0.25)
Dimensions:
Inches
(mm)
0.19±0.01
(4.83±0.25)
Features
• Axial Leaded Molded Inductors
• Available on Tape and Reel or
Ammo Pack for Auto placement
All specifications subject to change without notice.
Electrical
Inductance Range: 270 µH to 1000 µH.
Tolerance: 10% over entire range
Also available in tighter tolerances.
Test Frequency for (L): .79Mhz
Operating Temp.: -55°C to + 105 °C.
Current Rating: Based on a 10% drop in (L)
from initial value.
Part Temperature should not exceed 125ºC
measurements @ 20ºC.
Test Equipment
(L) & (Q): HP4342A & HP4285A
DCR: CH301 Current Source and DCR Meter
Physical
Packaging: 2500pcs per 13” Tape and Reel
500 per bag
Marking: EIA Inductance Code
714-665-1140
ALLIED COMPONENTS INTERNATIONAL
02/23/12
www.alliedcomponents.com