MCC MB3510-BC01

MCC
!"#
$
% !"#
Features
•
•
•
•
MB3505-BC01
THRU
MB3510-BC01
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Low Reverse Leakage Current
High Conductivity Metal Case
Any Mounting Position
Surge Rating Of 400 Amps
MB-35
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
MB3505-BC01
MB351-BC01
MB352-BC01
MB354-BC01
MB356-BC01
MB358-BC01
MB3510-BC01
Device
Marking
MB3505
MB351
MB352
MB354
MB356
MB358
MB3510
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
B
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
C
E
G
+
AC
D
H
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
2
I t Rating for Fusing
(<8.3mS)
IF(AV)
35.0A
TC = 55°C
IFSM
400A
8.3ms, half sine
-
A
AC
J
VF
1.2V
A
IFM = 17.5A per
element;
TJ = 25°C
DIMENSIONS
IR
2
It
10µA
1mA
664
TJ = 25°C
TJ = 125°C
2
AS
DIM
A
B
C
D
E
G
H
J
INCHES
MIN
1.115
.427
.469
.688
.618
.193
.618
.530
MAX
1.135
.322
.563
.730
.658
--.658
.570
www.mccsemi.com
MM
MIN
28.33
7.80
11.9
17.48
15.70
4.90
15.70
13.46
MAX
28.83
8.20
14.3
18.50
16.71
--16.71
14.48
NOTE
∅
MCC
MB3505-BC01 thru MB3510-BC01
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
20
2
1
10
.6
6
.4
4
.2
2
TJ=25°C
25°C
µAmps .1
1
Amps
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.4
.6
.8
1.0
1.2
40
60
80
100
120
140
1.4
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
60
600
50
500
40
400
300
30
Amps
Amps
200
20
100
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
0
150
1
2
4
Average Forward Rectified Current - Amperesversus
Case Temperature - °C
8 10
20
40
00
60 80 100
Cycles
175
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com