XP Power LCL150PS48 150- 500 watts lcl sery Datasheet

ACDC
150500 Watts
LCL Series
xppower.com
•
Single Output Industrial Supplies
•
High Efficiency
•
Low Cost
•
150 W Convection Cooled
•
300 W & 500 W with Internal Fans
•
Outputs from 12 V to 48 V
•
3 Year Warranty
Specification
Input
General
• 85-264 VAC (127-370 VDC) (see note 1)
• 47-63 Hz
• 2.1 A max for LCL150, 4.5 A max for
LCL300, 6.6 A max for LCL500
Inrush Current
• 40 A max for LCL150,
60 A max for LCL300 & 500
cold start at 25 °C, 230 VAC
Power Factor
• >0.9
Earth Leakage Current • <2 mA at 264 VAC, 60 Hz
Input Protection
• LCL150: T3.15 A/250 V,
LCL300: T6.3A/250 V,
LCL500: T10A/250 V,
internal fuse fitted in line
Input Voltage
Input Frequency
Input Current
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 88% typical at full load & 230 VAC
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 90-110 kHz main converter & 45-190 kHz
PFC for LCL150, 80-190 kHz main converter
& 62-65 kHz PFC for LCL300 & 500
• 2.7 W/in3 LCL150, 4.4 W/in3 LCL300,
4.9 W/in3 LCL500
• LCL150: >489 kHrs,
LCL300: >235 kHrs,
LCL500: >211 kHrs to MIL-HBK-217F at
25 °C, GB
Environmental
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
•
•
•
•
•
Start Up Rise Time
•
Hold Up Time
Line Regulation
•
•
Load Regulation
Transient Response
•
•
Ripple & Noise
Overvoltage Protection
Overtemperature
Protection
Overload Protection
•
•
•
•
Short Circuit Protection •
Remote Sense
•
Remote On/Off
•
See tables
See tables
±100 mV at 50% load
None required
2 s max for LCL150, 1.5 s max for LCL300,
0.8 s max for LCL500
50 ms max for LCL150,
35 ms max for LCL300 & LCL500
10 ms min at 115 VAC and full load
±0.5% max for LCL150,
±0.3% for LCL300 & LCL500
±1% max
4% max deviation recovery to within 1%
in 500 µs for a 50% load change
See tables
110-140%, recycle input to reset
Output turns off when OTP triggered,
measured internally, auto recovery
110-150% of rated output power. Delayed
by 1 s min to allow for peak loads.
Trip and restart (hiccup mode),
auto recovery
Fitted to LCL500 only, compensates for
0.25 V max each line
Fitted on LCL500 only,
On = logic low or open circuit,
Off = logic high
Operating Temperature • -10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• LCL150 convection cooled, LCL300 &
LCL500 have internal fans
Operating Humidity
• 5% to 90% non condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 10-500 Hz, 2 g, 10 mins per cycle on
3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 level B conducted,
level A radiated
• EN61000-3-2 class A
LCL150: EN61000-3-2 class C for loads ≥40%
LCL300 & LCL500: EN61000-3-2 class C
for loads ≥20%
• EN61000-3-3
• EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Performance Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5,
installation class 3, Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• EN60950-1, UL60950-1, CSA60950
No 22.2
Output Power(1)
Output Voltage
12.0 V
13.5 V
15.0 V
24.0 V
27.0 V
48.0 V
150 W
Trim Range
11.0-13.0 V
12.5-14.5 V
14.0-16.0 V
23.0-25.0 V
26.0-28.0 V
47.0-49.0 V
Output Current
12.5 A
11.1 A
10.0 A
6.3 A
5.6 A
3.1 A
Ripple & Noise(2)
100 mV pk-pk
100 mV pk-pk
100 mV pk-pk
150 mV pk-pk
150 mV pk-pk
250 mV pk-pk
Model Number
LCL150PS12
LCL150PS13
LCL150PS15
LCL150PS24
LCL150PS27
LCL150PS48
Notes
1. Output power derates linearly from 100% at 90 VAC to 90% at 85 VAC.
2. Measured with 20 MHz bandwidth.
Mechanical Details
1.02
(26.0)
1.97
(50.0)
0.90
(23.0)
0.57
(14.5)
4.64 (118.0)
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
Terminal Block, M4 Screw 7 pins 0.37 (9.5) centre
2.44 (62.0)
1
3.74
(95.0)
2.83 (72.0)
2 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
7
J1
7.55 (192.0)
1.02
(26.0)
4.64
(118.0)
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
0.57
(14.5)
0.90
(23.0)
Notes
3. Tolerance is ±0.05 (±0.2) maximum.
100
100
80
90
60
40
20
-10
Function
+Vout
+Vout
-Vout
-Vout
Ground
Neutral
Line
Output Power (%)
Output Power (%)
1. All dimensions shown in inches (mm).
2. Weight: 1.39 lbs (630 g) approx.
Pin
1
2
3
4
5
6
7
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85 90
100
110
120
230
Input Voltage (VAC)
240
250
264
ACDC
LCL150
Model and Ratings
Output Power(1)
Output Voltage
12.0 V
13.5 V
15.0 V
24.0 V
27.0 V
48.0 V
300 W
310 W
315 W
320 W
Trim Range
11.0-13.0 V
12.5-14.5 V
14.0-16.0 V
23.0-25.0 V
26.0-28.0 V
47.0-49.0 V
Output Current
25.0 A
22.0 A
20.0 A
13.0 A
11.7 A
6.70 A
Ripple & Noise(2)
150 mV pk-pk
150 mV pk-pk
150 mV pk-pk
150 mV pk-pk
200 mV pk-pk
240 mV pk-pk
Model Number
LCL300PS12
LCL300PS13
LCL300PS15
LCL300PS24
LCL300PS27
LCL300PS48
Notes
1. Output power derates linearly from 100% at 90 VAC to 90% at 85 VAC.
2. Measured with 20 MHz bandwidth.
Mechanical Details
8.07 (205.0)
3 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
1.97
(50.0) 0.94
(24.0)
0.63 (16.0)
Terminal Block, M4 Screw 9 pins 0.37 (9.5) centre
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
1
4.33
(110.0)
1.97
(50.0)
9
J1
0.63
7.44 (189.0)
(16.0)
3 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
6.81 (173.0)
0.98
(25.0)
0.50
(12.5)
1.97
(50.0)
6.81 (173.0)
Notes
1. All dimensions shown in inches (mm
2. Weight: 1.94 lbs (880 g) approx.
3. Tolerance is ±0.05 (±0.2) maximum.
4. Airflow direction is out of the unit at fan.
Pin
1
2
3
4
5
6
7
8
9
J1 Pin Connections
Function
+Vout
+Vout
+Vout
-Vout
-Vout
-Vout
Ground
Neutral
Line
Derating Curves
100
80
90
Output Power (%)
100
Output Power (%)
ACDC
LCL300
Model and Ratings
60
40
20
-10
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85 90
100
110
120
230
Input Voltage (VAC)
240
250
264
Output Power(1)
Output Voltage
12.0 V
13.5 V
15.0 V
24.0 V
27.0 V
48.0 V
500 W
Trim Range
11.0-13.0 V
12.5-14.5 V
14.0-16.0 V
23.0-25.0 V
26.0-28.0 V
47.0-49.0 V
Output Current
42.0 A
37.0 A
34.0 A
21.0 A
18.5 A
10.5 A
Ripple & Noise(2)
120 mV pk-pk
150 mV pk-pk
150 mV pk-pk
150 mV pk-pk
150 mV pk-pk
240 mV pk-pk
Model Number
LCL500PS12
LCL500PS13
LCL500PS15
LCL500PS24
LCL500PS27
LCL500PS48†
Notes
1. Output power derates linearly from 100% at 90 VAC to 90% at 85 VAC.
2. Measured with 20 MHz bandwidth.
Mechanical Details
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
1.41
(36.0)
1.00
(25.5)
2.08
(53.0)
0.60
(15.0)
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
Terminal Block, M4 Screw 9 pins 0.37 (9.5) centre
1
J2
4
AIRFLOW
1
3.54
(90.0)
5.00
(127.0)
9
9.21 (234.0)
J1
1.41
(36.0)
7.75 (197.0)
9.84 (250.0)
1.41
(0.36)
0.60
(15.0)
7.75 (197.0)
Notes
1.Dimensions shown in inches (mm).
2. Weight: 3.2 lbs (1.45 kg) approx.
Pin
1
2
1.00
(25.5)
3
4
4 x M4 x 0.7 THD
0.15 (3.8) Max Screw Penetration
5
6
7
8
9
3. Tolerance is ±0.05 (±0.2) maximum.
J1 Pin Connections
Function
+Vout
+Vout
+Vout
-Vout
-Vout
-Vout
Ground
Neutral
Line
Pin
1
2
3
4
J2 Pin Connections
Function
Remote On/Off Remote On/Off +
Sense Sense +
Applying >4.5 V to Pin 2 with
respect to Pin 1 turns output off.
Applying <0.8 V to Pin 2 with
respect to Pin 1 or open circuit
turns output on.
Mating Connectors (J2):
WST P4-I25002 housing
WST I25002BS contacts
100
100
80
90
Output Power (%)
Output Power (%)
Derating Curves
60
40
20
-10
0
10
20
30
40
50
Ambient Temperature (°C)
60
70
85 90
100
110
120
230
Input Voltage (VAC)
240
250
264
03-July-14
ACDC
LCL500
Model and Ratings