IRF HFA30TA60CS Ultrafast, soft recovery diode Datasheet

Bulletin PD-20374 01/01
HFA30TA60CS
HEXFRED
Ultrafast, Soft Recovery Diode
TM
VR = 600V
2
Features
•
•
•
•
•
VF(typ.)* = 1.2V
IF(AV) = 15A
Ultrafast Recovery
Ultrasoft Recovery
Very Low IRRM
Very Low Qrr
Specified at Operating Conditions
Qrr (typ.)= 80nC
IRRM (typ.) = 4.0A
Benefits
• Reduced RFI and EMI
• Reduced Power Loss in Diode and Switching
Transistor
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
1
3
trr(typ.) = 19ns
di(rec)M/dt (typ.)* = 160A/µs
Description
International Rectifier's HFA30TA60CS is a state of the art center tap ultra fast
recovery diode. Employing the latest in epitaxial construction and advanced
processing techniques it features a superb combination of characteristics
which result in performance which is unsurpassed by any rectifier previously
available. With basic ratings of 600 volts and 15 amps per Leg continuous
current, the HFA30TA60CS is especially well suited for use as the companion
diode for IGBTs and MOSFETs. In addition to ultra fast recovery time, the
HEXFRED product line features extremely low values of peak recovery current
(IRRM) and does not exhibit any tendency to "snap-off" during the tb portion of
recovery. The HEXFRED features combine to offer designers a rectifier with
lower noise and significantly lower switching losses in both the diode and the
switching transistor. These HEXFRED advantages can help to significantly
reduce snubbing, component count and heatsink sizes. The HEXFRED
HFA30TA60Cs is ideally suited for applications in power supplies and power
conversion systems (such as inverters), motor drives, and many other similar
applications where high speed, high efficiency is needed.
D2Pak
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 100°C
IFSM
IFRM
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Single Pulse Forward Current
Maximum Repetitive Forward Current
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max
Units
600
15
150
60
74
29
V
-55 to +150
W
A
C
* 125°C
1
HFA30TA60CS
Bulletin PD-20374 01/01
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min Typ Max Units
V BR
Cathode Anode Breakdown Voltage
600
V
VFM
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
Junction Capacitance
1.3 1.7
1.5 2.0
1.2 1.6
1.0
10
400 1000
25
50
LS
Series Inductance
8.0
V
µA
pF
nH
Test Conditions
IR = 100µA
IF = 15A
See Fig. 1
IF = 30A
IF = 15A, TJ = 125°C
VR = VR Rated
See Fig. 2
TJ = 125°C, VR = 0.8 x VR RatedD Rated
See Fig. 3
VR = 200V
Measured lead to lead 5mm from
package body
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
See Fig. 5, 10
Peak Recovery Current
See Fig. 6
Reverse Recovery Charge
See Fig. 7
Peak Rate of Fall of Recovery Current
During tb
See Fig. 8
Min Typ Max Units
19
42
70
4.0
6.5
80
220
188
160
60
90
6.0
10
180
450
ns
A
nC
A/µs
Test Conditions
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
TJ = 25°C
TJ = 125°C
IF = 15A
TJ = 25°C
TJ = 125°C
VR = 200V
TJ = 25°C
TJ = 125°C
dif/dt = 200A/µs
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics (per Leg)
Parameter
Tlead!
RthJC
RthJA"
Wt
Mounting Torque
!
"
2
Min
Lead Temperature
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Thermal Resistance, Junction to Ambient
Weight
Typ
Max
Units
300
1.7
0.85
80
°C
2.0
0.07
6.0
5.0
12
10
K/W
g
(oz)
Kg-cm
lbf•in
0.063 in. from Case (1.6mm) for 10 sec
Typical Socket Mount
www.irf.com
HFA30TA60CS
Bulletin PD-20374 01/01
Reverse Current - IR (µA)
10000
TJ = 150°C
TJ = 150°C
1000
100
TJ = 125°C
10
1
0.1
TJ = 25°C
A
0.01
TJ = 125°C
10
0
100
200
300
400
500
600
Reverse Voltage - V R (V)
TJ = 25°C
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage, (per Leg)
100
1
1.0
A
1.2
1.4
1.6
1.8
2.0
2.2
2.4
ForwardVoltage
VoltageDrop
Drop- -VVFM
(V)
Forward
FM(V)
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current,
(per Leg)
Junction Capacitance -CT (pF)
Instantaneous Forward Current - IF (A)
100
A
TJ = 25°C
A
10
0
100
200
300
400
500
600
Reverse Voltage - V R (V)
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage, (per Leg)
Thermal Response (Z thJC )
10
1
D = 0.50
0.20
0.10
PDM
0.05
0.1
t1
0.02
0.01
0.01
0.00001
t2
SINGLE PULSE
(THERMAL RESPONSE)
0.0001
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.001
0.01
0.1
1
10
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics, (per Leg)
www.irf.com
3
HFA30TA60CS
Bulletin PD-20374 01/01
100
25
VR = 200V
TJ = 125°C
TJ = 25°C
I F = 30A
I F = 15A
I F = 5.0A
80
20
I F = 30A
I F = 15A
Irr- ( A)
trr- (ns)
I F = 5.0A
60
40
15
10
20
5
VR = 200V
TJ = 125°C
TJ = 25°C
0
100
A
di f /dt - (A/µs)
10000
800
VR = 200V
TJ = 125°C
TJ = 25°C
VR = 200V
TJ = 125°C
TJ = 25°C
I F = 30A
di (rec) M/dt- (A /µs)
I F = 15A
Qrr- (nC)
di f /dt - (A/µs)
1000
Fig. 6 - Typical Recovery Current vs. dif/dt,
(per Leg)
Fig. 5 - Typical Reverse Recovery Time vs.
dif/dt, (per Leg)
600
A
0
100
1000
IF = 5.0A
400
I F = 30A
I F = 15A
1000
I F = 5.0A
200
0
100
A
di f /dt - (A/µs)
1000
Fig. 7 - Typical Stored Charge vs. dif/dt,
(per Leg)
4
100
100
A
di f /dt - (A/µs)
1000
Fig. 8 - Typical di(rec)M/dt vs. dif/dt,
(per Leg)
www.irf.com
HFA30TA60CS
Bulletin PD-20374 01/01
3
t rr
IF
REVERSE RECOVERY CIRCUIT
tb
ta
0
Q rr
VR = 200V
2
I RRM
4
0.5 I RRM
di(rec)M/dt
0.01 Ω
L = 70µH
D.U.T.
dif/dt
ADJUST
D
G
IRFP250
S
Fig. 9 - Reverse Recovery Parameter Test
Circuit
www.irf.com
5
0.75 I RRM
1
di f /dt
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and
Definitions
5
HFA30TA60CS
Bulletin PD-20374 01/01
4.69 (0.18)
4.20 (0.16)
10.16 (0.40)
REF.
1.32 (0.05)
15.49 (0.61)
1.22 (0.05)
6.47 (0.25)
93°
6.18 (0.24)
14.73 (0.58)
5.28 (0.21)
2.61 (0.10)
4.78 (0.19)
2.32 (0.09)
0.55 (0.02)
8.89 (0.35)
3X
REF.
1.40 (0.055)
1.14 (0.045)
2X
1
0.46 (0.02)
0.93 (0.37)
MINIMUM RECOMMENDED FOOTPRINT
0.69 (0.27)
11.43 (0.45)
3
4.57 (0.18)
2
4.32 (0.17)
8.89 (0.35)
17.78 (0.70)
0.61 (0.02) MAX.
5.08 (0.20) REF.
3.81 (0.15)
2.08 (0.08)
2X
2.54 (0.10)
2X
Conforms to JEDEC Outline D2PAK
Dimensions in millimeters and inches
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 01/01