Cypress CY7C09179V-7AC 3.3v 32k/64k/128k x 8/9 synchronous dual-port static ram Datasheet

25/0251
CY7C09079V/89V/99V
CY7C09179V/89V/99V
3.3V 32K/64K/128K x 8/9
Synchronous Dual-Port Static RAM
Features
• True Dual-Ported memory cells which allow simultaneous access of the same memory location
• 6 Flow-Through/Pipelined devices
— 32K x 8/9 organizations (CY7C09079V/179V)
— 64K x 8/9 organizations (CY7C09089V/189V)
— 128K x 8/9 organizations (CY7C09099V/199V)
• 3 Modes
— Flow-Through
• High-speed clock to data access 6.5[1]/7.5[1]/9/12 ns
(max.)
• 3.3V low operating power
— Active= 115 mA (typical)
— Standby= 10 µA (typical)
• Fully synchronous interface for easier operation
• Burst counters increment addresses internally
— Shorten cycle times
— Minimize bus noise
— Pipelined
— Burst
• Pipelined output mode on both ports allows fast
100-MHz operation
• 0.35-micron CMOS for optimum speed/power
•
•
•
•
— Supported in Flow-Through and Pipelined modes
Dual Chip Enables for easy depth expansion
Automatic power-down
Commercial and Industrial temperature ranges
Available in 100-pin TQFP
v
Logic Block Diagram
R/WL
R/WR
OEL
OER
CE0L
CE1L
1
1
0
0
0/1
0/1
FT/PipeL
[2]
1
CE0R
CE1R
0/1
0
0
1
0/1
8/9
FT/PipeR
[2]
8/9
I/O0L–I/O7/8L
I/O0R–I/O7/8R
I/O
Control
[3]
A0–A14/15/16L
CLKL
ADSL
CNTENL
CNTRSTL
I/O
Control
15/16/17
15/16/17
Counter/
Address
Register
Decode
True Dual-Ported
RAM Array
Counter/
Address
Register
Decode
[3]
A0–A14/15/16R
CLKR
ADSR
CNTENR
CNTRSTR
Notes:
1. See page 6 for Load Conditions.
2. I/O0–I/O7 for x8 devices, I/O0–I/O8 for x9 devices.
3. A0–A14 for 32K, A0–A15 for 64K, and A0–A16 for 128K devices.
For the most recent information, visit the Cypress web site at www.cypress.com
Cypress Semiconductor Corporation • 3901 North First Street • San Jose • CA 95134 • 408-943-2600
Document #: 38-06043 Rev. *A
Revised December 27, 2002
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Functional Description
A HIGH on CE0 or LOW on CE1 for one clock cycle will power
down the internal circuitry to reduce the static power consumption. The use of multiple Chip Enables allows easier banking
of multiple chips for depth expansion configurations. In the
pipelined mode, one cycle is required with CE0 LOW and CE1
HIGH to reactivate the outputs.
The CY7C09079V/89V/99V and CY7C09179V/89V/99V are
high-speed synchronous CMOS 32K, 64K, and 128K x 8/9
dual-port static RAMs. Two ports are provided, permitting independent, simultaneous access for reads and writes to any
location in memory.[4] Registers on control, address, and data
lines allow for minimal set-up and hold times. In pipelined output mode, data is registered for decreased cycle time. Clock
to data valid tCD2 = 6.5 ns[1] (pipelined). Flow-through mode
can also be used to bypass the pipelined output register to
eliminate access latency. In flow-through mode data will be
available tCD1 = 18 ns after the address is clocked into the
device. Pipelined output or flow-through mode is selected via
the FT/Pipe pin.
Counter enable inputs are provided to stall the operation of the
address input and utilize the internal address generated by the
internal counter for fast interleaved memory applications. A
port’s burst counter is loaded with the port’s Address Strobe
(ADS). When the port’s Count Enable (CNTEN) is asserted,
the address counter will increment on each LOW-to-HIGH
transition of that port’s clock signal. This will read/write one
word from/into each successive address location until CNTEN
is deasserted. The counter can address the entire memory
array and will loop back to the start. Counter Reset (CNTRST)
is used to reset the burst counter.
Each port contains a burst counter on the input address register. The internal write pulse width is independent of the
LOW-to-HIGH transition of the clock signal. The internal write
pulse is self-timed to allow the shortest possible cycle times.
All parts are available in 100-pin Thin Quad Plastic Flatpack
(TQFP) packages.
NC
NC
A6R
A5R
A4R
A3R
A2R
A1R
A0R
CLKR
ADSR
GND
ADSL
CLKL
CNTENL
A0L
A1L
A2L
A3L
A4L
A5L
A6L
NC
NC
100-Pin TQFP
(Top View)
CNTENR
Pin Configurations
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
[7]
NC
1
75
NC
NC
2
74
NC
A7L
3
73
A7R
A8L
4
72
A8R
A9L
5
71
A9R
A10L
6
70
A10R
A11L
7
69
A11R
A12L
8
68
A12R
A13L
9
67
A13R
A14L
10
66
A14R
[5]
A15L
11
65
A15R
[5]
[6]
A16L
12
64
A16R
[6]
VCC
13
63
GND
NC
14
62
NC
NC
15
61
NC
NC
16
60
NC
NC
17
59
NC
CE0L
18
58
CE0R
CE1L
19
57
CE1R
CNTRSTL
20
56
CNTRSTR
R/WL
21
55
R/WR
CY7C09099V (128K x 8)
CY7C09089V (64K x 8)
CY7C09079V (32K x 8)
OEL
22
54
OER
FT/PIPEL
23
53
FT/PIPER [7]
NC
24
52
GND
NC
25
51
NC
NC
NC
NC
I/O7R
I/O6R
I/O5R
I/O4R
I/O3R
VCC
I/O2R
I/01R
I/O0R
GND
VCC
I/O0L
I/O1L
GND
I/O2L
I/O3L
I/O4L
I/O5L
I/O6L
I/O7L
NC
GND
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Notes:
4. When writing simultaneously to the same location, the final value cannot be guaranteed.
5. This pin is NC for CY7C09079V.
6. This pin is NC for CY7C09079V and CY7C09089V.
Document #: 38-06043 Rev. *A
Page 2 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
7.
For CY7C09079V and CY7C09089V, pin #23 connected to VCC is pin compatible with an IDT 5V x8 pipelined device; connecting pin #23 and #53 to GND is
pin compatible with an IDT 5V x16 flow-through device.
Pin Configurations (continued)
NC
A6R
A5R
A4R
A3R
A2R
A1R
A0R
CNTENR
CLKR
ADSR
GND
GND
ADSL
CLKL
CNTENL
A0L
A1L
A2L
A3L
A4L
A5L
A6L
NC
NC
100-Pin TQFP
(Top View)
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
NC
1
75
NC
NC
2
74
NC
A7L
3
73
A7R
A8L
4
72
A8R
A9L
5
71
A9R
A10L
6
70
A10R
A11L
7
69
A11R
A12L
8
68
A12R
A13L
9
67
A13R
A14L
10
66
A14R
A15L
11
65
A15R [8]
A16L
12
64
A16R [9]
VCC
13
63
GND
NC
14
62
NC
NC
15
61
NC
NC
16
60
NC
NC
17
59
NC
CE0L
18
58
CE0R
CE1L
19
57
CE1R
CNTRSTL
20
56
CNTRSTR
R/WL
21
55
R/WR
[8]
[9]
CY7C09199V (128K x 9)
CY7C09189V (64K x 9)
CY7C09179V (32K x 9)
OEL
22
54
OER
FT/PIPEL
23
53
FT/PIPER
NC
24
52
GND
NC
25
51
NC
NC
NC
I/O8R
I/O7R
I/O6R
I/O5R
I/O4R
I/O3R
VCC
I/O2R
I/01R
I/O0R
GND
VCC
I/O0L
I/O1L
GND
I/O2L
I/O3L
I/O4L
I/O5L
I/O6L
I/O7L
GND
I/O8L
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Selection Guide
CY7C09079V/89V/99V CY7C09079V/89V/99V CY7C09079V/89V/99V CY7C09079V/89V/99V
CY7C09179V/89V/99V CY7C09179V/89V/99V CY7C09179V/89V/99V CY7C09179V/89V/99V
-6[1]
-7[1]
-9
-12
fMAX2 (MHz) (Pipelined)
100
83
67
50
Max. Access Time (ns)
(Clock to Data,
Pipelined)
6.5
7.5
9
12
Typical Operating
Current ICC (mA)
175
155
135
115
Typical Standby Current for ISB1 (mA) (Both
Ports TTL Level)
25
25
20
20
Typical Standby Current for ISB3 (µA) (Both
Ports CMOS Level)
10 µA
10 µA
10 µA
10 µA
Notes:
8. This pin is NC for CY7C09179V.
9. This pin is NC for CY7C09179V and CY7C09189V.
Document #: 38-06043 Rev. *A
Page 3 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Pin Definitions
Left Port
Right Port
Description
A0L–A16L
A0R–A16R
Address Inputs (A0–A14 for 32K; A0–A15 for 64K; and A0–A16 for 128K devices).
ADSL
ADSR
Address Strobe Input. Used as an address qualifier. This signal should be asserted LOW to
access the part using an externally supplied address. Asserting this signal LOW also loads the
burst counter with the address present on the address pins.
CE0L,CE1L
CE0R,CE1R
Chip Enable Input. To select either the left or right port, both CE0 AND CE1 must be asserted to
their active states (CE0 ≤ VIL and CE1 ≥ VIH).
CLKL
CLKR
Clock Signal. This input can be free running or strobed. Maximum clock input rate is fMAX.
CNTENL
CNTENR
Counter Enable Input. Asserting this signal LOW increments the burst address counter of its
respective port on each rising edge of CLK. CNTEN is disabled if ADS or CNTRST are asserted
LOW.
CNTRSTL
CNTRSTR
Counter Reset Input. Asserting this signal LOW resets the burst address counter of its respective
port to zero. CNTRST is not disabled by asserting ADS or CNTEN.
I/O0L–I/O8L
I/O0R–I/O8R
Data Bus Input/Output (I/O0–I/O7 for x8 devices; I/O0–I/O8 for x9 devices).
OEL
OER
Output Enable Input. This signal must be asserted LOW to enable the I/O data pins during read
operations.
R/WL
R/WR
Read/Write Enable Input. This signal is asserted LOW to write to the dual port memory array.
For read operations, assert this pin HIGH.
FT/PIPEL
FT/PIPER
Flow-Through/Pipelined Select Input. For flow-through mode operation, assert this pin LOW. For
pipelined mode operation, assert this pin HIGH.
GND
Ground Input.
NC
No Connect.
VCC
Power Input.
Maximum Ratings[10]
Output Current into Outputs (LOW)20 mA
(Above which the useful life may be impaired. For user guidelines, not tested.)
Static Discharge Voltage>2001V
Latch-Up Current>200 mA
Storage Temperature –65°C to +150°C
Ambient Temperature with Power Applied–55°C to +125°C
Operating Range
Supply Voltage to Ground Potential–0.5V to +4.6V
DC Voltage Applied to
Outputs in High Z State–0.5V to VCC+0.5V
DC Input Voltage–0.5V to VCC+0.5V
Ambient
Temperature
VCC
Commercial
0°C to +70°C
3.3V ± 300 mV
Industrial[11]
–40°C to +85°C
3.3V ± 300 mV
Range
Note:
10. The Voltage on any input or I/O pin cannot exceed the power pin during power-up.
11. Industrial parts are available in CY7C09099V and CY7C09199V only.
Document #: 38-06043 Rev. *A
Page 4 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Electrical Characteristics Over the Operating Range
CY7C09079V/89V/99V
CY7C09179V/89V/99V
2.4
Output HIGH Voltage (VCC = Min.
IOH = –4.0 mA)
VOL
Output LOW Voltage (VCC = Min.
IOH = +4.0 mA)
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IOZ
Output Leakage Current
ICC
Com’l.
Operating Current
(VCC = Max. IOUT = 0 mA)
Ind.[11]
Outputs Disabled
175
Standby Current (Both
Com’l.
Ports TTL Level)[12] CEL
Ind.[11]
& CER ≥ VIH, f = fMAX
25
Standby Current (One
Com’l.
Port TTL Level)[12] CEL |
Ind.[11]
CER ≥ VIH, f = fMAX
115
Standby Current (Both
Com’l.
Ports CMOS Level)[12]
Ind.[11]
CEL & CER ≥ VCC – 0.2V,
f=0
10
Standby Current (One
Com’l.
Port CMOS Level)[12]
Ind.[11]
CEL | CER ≥ VIH, f = fMAX
105
ISB2
ISB3
ISB4
2.0
10
320
95
175
250
135
2.0
10
0.4
2.0
10
155
275
135
225
275
390
185
295
25
85
20
65
85
120
35
75
105
165
95
150
165
210
105
160
10
250
10
250
10
250
10
250
95
125
85
115
125
170
95
125
V
V
0.8
–10
Unit
Max.
Typ.
V
0.4
0.8
–10
Min.
Max.
Typ.
2.4
0.4
0.8
–10
-12
2.4
0.4
2.0
Min.
Max.
Typ.
Min.
-9
2.4
VOH
ISB1
-7[1]
Max.
Description
Typ.
Parameter
Min.
-6[1]
–10
115
0.8
V
10
µA
205
mA
mA
20
50
mA
mA
85
140
mA
mA
10
250
µA
µA
75
100
mA
mA
Capacitance
Parameter
Description
CIN
Input Capacitance
COUT
Output Capacitance
Test Conditions
TA = 25°C, f = 1 MHz,
VCC = 3.3V
Max.
Unit
10
pF
10
pF
Note:
12. CEL and CER are internal signals. To select either the left or right port, both CE0 AND CE1 must be asserted to their active states (CE0 ≤ VIL and CE1 ≥ VIH).
Document #: 38-06043 Rev. *A
Page 5 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
AC Test Loads
3.3V
3.3V
R1 = 590Ω
OUTPUT
RTH = 250Ω
OUTPUT
R1 = 590Ω
OUTPUT
C = 30 pF
C = 30 pF
R2 = 435Ω
C = 5 pF
R2 = 435Ω
VTH = 1.4V
(a) Normal Load (Load 1)
(c) Three-State Delay (Load 2)
(Used for tCKLZ, tOLZ, & tOHZ
including scope and jig)
(b) Thévenin Equivalent (Load 1)
AC Test Loads (Applicable to -6 and -7 only)[13]
Z0 = 50Ω
OUTPUT
ALL INPUT PULSES
R = 50Ω
3.0V
C
GND
90%
10%
90%
10%
≤ 3 ns
≤ 3 ns
VTH = 1.4V
(a) Load 1 (-6 and -7 only)
0. 60
∆ (ns) for all -7 access times
0. 50
0. 40
0. 30
0. 20
0. 1 0
0. 00
10
15
20
25
30
35
Capacitance (pF)
(b) Load Derating Curve
Note:
13. Test Conditions: C = 10 pF.
Document #: 38-06043 Rev. *A
Page 6 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Characteristics Over the Operating Range
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Unit
Max.
Min.
Max.
-12
Min.
Max.
Description
-9
Min.
Min.
Parameter
-7[1]
Max.
-6[1]
fMAX1
fMax Flow-Through
53
45
40
33
MHz
fMAX2
fMax Pipelined
100
83
67
50
MHz
tCYC1
Clock Cycle Time - Flow-Through
19
22
25
30
ns
tCYC2
Clock Cycle Time - Pipelined
10
12
15
20
ns
tCH1
Clock HIGH Time - Flow-Through
6.5
7.5
12
12
ns
tCL1
Clock LOW Time - Flow-Through
6.5
7.5
12
12
ns
tCH2
Clock HIGH Time - Pipelined
4
5
6
8
ns
tCL2
Clock LOW Time - Pipelined
4
5
6
8
ns
tR
Clock Rise Time
3
3
3
3
ns
tF
Clock Fall Time
3
3
3
3
ns
tSA
Address Set-Up Time
tHA
Address Hold Time
tSC
Chip Enable Set-Up Time
tHC
Chip Enable Hold Time
tSW
R/W Set-Up Time
tHW
R/W Hold Time
tSD
Input Data Set-Up Time
tHD
Input Data Hold Time
tSAD
ADS Set-Up Time
tHAD
ADS Hold Time
tSCN
CNTEN Set-Up Time
tHCN
CNTEN Hold Time
tSRST
CNTRST Set-Up Time
tHRST
CNTRST Hold Time
3.5
4
4
4
ns
0
0
1
1
ns
3.5
4
4
4
ns
0
0
1
1
ns
3.5
4
4
4
ns
0
0
1
1
ns
3.5
4
4
4
ns
0
0
1
1
ns
3.5
4
4
4
ns
0
0
1
1
ns
3.5
4.5
5
5
ns
0
0
1
1
ns
3.5
4
4
4
ns
0
0
1
1
ns
tOE
Output Enable to Data Valid
tOLZ[14, 15]
OE to Low Z
2
[14, 15]
OE to High Z
1
tOHZ
8
tCD1
Clock to Data Valid - Flow-Through
tCD2
Clock to Data Valid - Pipelined
tDC
Data Output Hold After Clock HIGH
2
[14, 15]
Clock HIGH to Output High Z
2
[14, 15]
Clock HIGH to Output Low Z
2
tCKHZ
tCKLZ
9
2
7
1
15
7
1
18
6.5
2
7
2
1
9
2
9
12
2
20
7.5
2
9
10
2
2
ns
7
ns
25
ns
12
ns
2
9
2
2
ns
ns
9
2
ns
ns
Port to Port Delays
tCWDD
Write Port Clock HIGH to Read Data Delay
30
35
40
40
ns
tCCS
Clock to Clock Set-Up Time
9
10
15
15
ns
Notes:
14. Test conditions used are Load 2.
15. This parameter is guaranteed by design, but it is not production tested.
Document #: 38-06043 Rev. *A
Page 7 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Read Cycle for Flow-Through Output (FT/PIPE = VIL)[16, 17, 18, 19]
tCH1
tCYC1
tCL1
CLK
CE0
tSC
tHC
tSW
tSA
tHW
tHA
tSC
tHC
CE1
R/W
An
ADDRESS
An+1
An+2
An+3
tCKHZ
tDC
tCD1
DATAOUT
Qn
Qn+1
Qn+2
tDC
tCKLZ
tOHZ
tOLZ
OE
tOE
Read Cycle for Pipelined Operation (FT/PIPE = VIH)[16, 17, 18, 19]
tCH2
tCYC2
tCL2
CLK
CE0
tSC
tHC
tSW
tSA
tHW
tHA
tSC
tHC
CE1
R/W
ADDRESS
An
DATAOUT
An+1
1 Latency
An+2
tDC
tCD2
Qn
tCKLZ
An+3
Qn+1
tOHZ
Qn+2
tOLZ
OE
tOE
Notes:
16. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge.
17. ADS = VIL, CNTEN and CNTRST = VIH.
18. The output is disabled (high-impedance state) by CE0=VIH or CE1 = VIL following the next rising edge of the clock.
19. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK. Numbers are for reference only.
Document #: 38-06043 Rev. *A
Page 8 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Bank Select Pipelined Read[20, 21]
-
tCYC2
tCH2
tCL2
CLKL
tHA
tSA
ADDRESS(B1)
A0
A1
A3
A2
A4
A5
tHC
tSC
CE0(B1)
tCD2
tHC
tSC
tCD2
tHA
tSA
tDC
A0
ADDRESS(B2)
A1
tDC
tSC
tCKLZ
A3
A2
tCKHZ
D3
D1
D0
DATAOUT(B1)
tCD2
tCKHZ
A4
A5
tHC
CE0(B2)
tSC
tCD2
tHC
DATAOUT(B2)
tCKHZ
tCD2
D4
D2
tCKLZ
tCKLZ
Left Port Write to Flow-Through Right Port Read[22, 23, 24, 25]
CLKL
tSW
tHW
tSA
tHA
R/WL
ADDRESSL
NO
MATCH
MATCH
tHD
tSD
DATAINL
VALID
tCCS
CLKR
R/WR
tCD1
tSW
tSA
ADDRESSR
tHW
tHA
NO
MATCH
MATCH
tCWDD
DATAOUTR
tCD1
VALID
tDC
VALID
tDC
Notes:
20. In this depth expansion example, B1 represents Bank #1 and B2 is Bank #2; Each Bank consists of one Cypress dual-port device from this datasheet.
ADDRESS(B1) = ADDRESS(B2).
21. OE and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH.
22. The same waveforms apply for a right port write to flow-through left port read.
23. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH.
24. OE = VIL for the right port, which is being read from. OE = VIH for the left port, which is being written to.
25. It tCCS ≤ maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS>maximum specified, then data is not
valid until tCCS + tCD1. tCWDD does not apply in this case.
Document #: 38-06043 Rev. *A
Page 9 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Pipelined Read-to-Write-to-Read (OE = VIL)[19, 26, 27, 28]
tCH2
tCYC2
tCL2
CLK
CE0
tSC
tHC
CE1
tSW
tHW
R/W
tSW
tHW
An
ADDRESS
An+1
tSA
An+2
An+2
An+3
An+4
tSD tHD
tHA
DATAIN
tCD2
tCKHZ
Dn+2
tCD2
tCKLZ
Qn
DATAOUT
READ
Pipelined Read-to-Write-to-Read (OE
tCH2
tCYC2
Qn+3
NO OPERATION
WRITE
READ
Controlled)[19, 26, 27, 28]
tCL2
CLK
CE0
tSC
tHC
CE1
R/W
tSW tHW
tSW
tHW
An
An+1
An+2
An+3
An+4
An+5
ADDRESS
tSA
tHA
tSD tHD
Dn+2
DATAIN
Dn+3
tCD2
DATAOUT
tCKLZ
tCD2
Qn
Qn+4
tOHZ
OE
READ
WRITE
READ
Notes:
26. Output state (HIGH, LOW, or high-impedance) is determined by the previous cycle control signals.
27. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH.
28. During “No Operation”, data in memory at the selected address may be corrupted and should be re-written to ensure data integrity.
Document #: 38-06043 Rev. *A
Page 10 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Flow-Through Read-to-Write-to-Read (OE = VIL)[17, 19, 26, 27, 28]
tCH1
tCYC1
tCL1
CLK
CE0
tSC
tHC
CE1
tSW
tHW
R/W
tSW
tHW
An
ADDRESS
An+1
tSA
DATAIN
An+2
An+2
tSD
tHA
An+3
tHD
Dn+2
tCD1
tCD1
DATAOUT
An+4
tCD1
Qn
Qn+1
tDC
tCKHZ
READ
tCD1
Qn+3
tCKLZ
NO
OPERATION
WRITE
tDC
READ
Flow-Through Read-to-Write-to-Read (OE Controlled)[17, 20, 26, 27, 28]
tCH1
tCYC1
tCL1
CLK
CE0
tSC
tHC
CE1
tSW
tHW
R/W
tSW
tHW
An
An+1
An+2
An+3
An+4
An+5
ADDRESS
tSA
DATAIN
tSD
tHA
DATAOUT
Dn+2
tDC
tCD1
tHD
Dn+3
tOE
tCD1
Qn
tCD1
Qn+4
tOHZ
tCKLZ
tDC
OE
READ
Document #: 38-06043 Rev. *A
WRITE
READ
Page 11 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Pipelined Read with Address Counter Advance[29]
tCH2
tCYC2
tCL2
CLK
tSA
tHA
ADDRESS
An
tSAD
tHAD
ADS
tSAD
tHAD
tSCN
tHCN
CNTEN
tSCN
DATAOUT
tHCN
Qx-1
tCD2
Qx
READ
EXTERNAL
ADDRESS
Qn
Qn+1
tDC
READ WITH COUNTER
Qn+2
COUNTER HOLD
Qn+3
READ WITH COUNTER
Flow-Through Read with Address Counter Advance[29]
tCH1
tCYC1
tCL1
CLK
tSA
tHA
An
ADDRESS
tSAD
tHAD
ADS
tSAD
tHAD
tSCN
tHCN
CNTEN
tSCN
DATAOUT
tHCN
tCD1
Qx
Qn
Qn+1
tDC
READ
EXTERNAL
ADDRESS
READ WITH COUNTER
Qn+3
Qn+2
COUNTER HOLD
READ
WITH
COUNTER
Note:
29. CE0 and OE = VIL; CE1, R/W and CNTRST = VIH.
Document #: 38-06043 Rev. *A
Page 12 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Write with Address Counter Advance (Flow-Through or Pipelined Outputs)[30, 31]
tCH2
tCYC2
tCL2
CLK
tSA
tHA
An
ADDRESS
INTERNAL
ADDRESS
An
tSAD
tHAD
tSCN
tHCN
An+1
An+2
An+3
An+4
ADS
CNTEN
Dn
DATAIN
tSD
tHD
WRITE EXTERNAL
ADDRESS
Dn+1
Dn+1
WRITE WITH
COUNTER
Dn+2
WRITE COUNTER
HOLD
Dn+3
Dn+4
WRITE WITH COUNTER
Notes:
30. CE0 and R/W = VIL; CE1 and CNTRST = VIH.
31. The “Internal Address” is equal to the “External Address” when ADS = VIL and equals the counter output when ADS = VIH.
Document #: 38-06043 Rev. *A
Page 13 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Switching Waveforms (continued)
Counter Reset (Pipelined Outputs)[19, 26, 32, 33]
tCH2
tCYC2
tCL2
CLK
tSA
tHA
An
ADDRESS
INTERNAL
ADDRESS
AX
0
tSW
tHW
tSD
tHD
1
An+1
An
An+1
R/W
tSAD
tHAD
tSCN
tHCN
tSRST
tHRST
ADS
CNTEN
CNTRST
DATAIN
D0
DATAOUT
Q0
COUNTER
RESET
WRITE
ADDRESS 0
READ
ADDRESS 0
READ
ADDRESS 1
Q1
Qn
READ
ADDRESS n
Notes:
32. CE0 = VIL; CE1 = VIH.
33. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset.
Document #: 38-06043 Rev. *A
Page 14 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Read/Write and Enable Operation[34, 35, 36]
Inputs
OE
CLK
CE0
Outputs
CE1
R/W
I/O0–I/O9
Operation
[37]
X
H
X
X
High-Z
Deselected
X
X
L
X
High-Z
Deselected[37]
X
L
H
L
DIN
Write
L
L
H
H
DOUT
Read[37]
L
H
X
High-Z
Outputs Disabled
H
X
Address Counter Control Operation[34, 38, 39, 40]
Address
Previous
Address
X
CLK
ADS
CNTEN
X
X
X
An
X
L
X
An
X
An
CNTRST
I/O
Mode
Operation
L
Dout(0)
Reset
Counter Reset to Address 0
X
H
Dout(n)
Load
Address Load into Counter
H
H
H
Dout(n)
Hold
External Address Blocked—Counter
Disabled
H
L
H
Dout(n+1)
Increment
Counter Enabled—Internal Address
Generation
Notes:
34. “X” = “Don’t Care”, “H” = VIH, “L” = VIL.
35. ADS, CNTEN, CNTRST = “Don’t Care.”
36. OE is an asynchronous input signal.
37. When CE changes state in the pipelined mode, deselection and read happen in the following clock cycle.
38. CE0 and OE = VIL; CE1 and R/W = VIH.
39. Data shown for flow-through mode; pipelined mode output will be delayed by one cycle.
40. Counter operation is independent of CE0 and CE1.
Document #: 38-06043 Rev. *A
Page 15 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Ordering Information
32K x8 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
Package Type
Operating Range
[1]
CY7C09079V-6AC
A100
100-Pin Thin Quad Flat Pack
Commercial
7.5[1]
CY7C09079V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
7.5[1]
CY7C09079V-7AI
A100
100-Pin Thin Quad Flat Pack
Industrial
9
CY7C09079V-9AC
A100
100-Pin Thin Quad Flat Pack
Commercial
12
CY7C09079V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
6.5
64K x8 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
Package Type
Operating Range
6.5[1]
CY7C09089V-6AC
A100
100-Pin Thin Quad Flat Pack
7.5[1]
CY7C09089V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
9
CY7C09089V-9AC
A100
100-Pin Thin Quad Flat Pack
Commercial
12
CY7C09089V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
Commercial
128K x8 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
Package Type
Operating Range
6.5[1]
CY7C09099V-6AC
A100
100-Pin Thin Quad Flat Pack
Commercial
7.5[1]
CY7C09099V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
9
CY7C09099V-9AC
A100
100-Pin Thin Quad Flat Pack
Commercial
CY7C09099V-9AI
A100
100-Pin Thin Quad Flat Pack
Industrial
CY7C09099V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
12
32K x9 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
6.5[1]
CY7C09179V-6AC
A100
7.5[1]
Package Type
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
CY7C09179V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
9
CY7C09179V-9C
A100
100-Pin Thin Quad Flat Pack
Commercial
12
CY7C09179V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
64K x9 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
Package Type
Operating Range
[1]
CY7C09189V-6AC
A100
100-Pin Thin Quad Flat Pack
Commercial
7.5[1]
CY7C09189V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
6.5
9
CY7C09189V-9AC
A100
100-Pin Thin Quad Flat Pack
Commercial
12
CY7C09189V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
128K x9 3.3V Synchronous Dual-Port SRAM
Speed (ns)
Ordering Code
Package Name
Package Type
Operating Range
[1]
6.5
CY7C09199V-6AC
A100
100-Pin Thin Quad Flat Pack
Commercial
7.5[1]
CY7C09199V-7AC
A100
100-Pin Thin Quad Flat Pack
Commercial
9
CY7C09199V-9AC
A100
100-Pin Thin Quad Flat Pack
Commercial
CY7C09199V-9AI
A100
100-Pin Thin Quad Flat Pack
Industrial
CY7C09199V-12AC
A100
100-Pin Thin Quad Flat Pack
Commercial
12
Document #: 38-06043 Rev. *A
Page 16 of 18
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Package Diagram
100-Pin Thin Plastic Quad Flat Pack (TQFP) A100
51-85048-B
Document #: 38-06043 Rev. *A
Page 17 of 18
© Cypress Semiconductor Corporation, 2001. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.
CY7C09079V/89V/99V
CY7C09179V/89V/99V
Document Title: CY7C09079V/89V/99V, CY7C09179V/89V/99V 3.3V 32K/64K/128K x 8/9Synchronous Dual Port Static
RAM
Document Number: 38-06043
REV.
ECN NO.
Issue
Date
Orig. of
Change
Description of Change
**
110191
09/29/01
SZV
Change from Spec number: 38-00667 to 38-06043
*A
122293
12/27/02
RBI
Power up requirements added to Operating Conditions Information
Document #: 38-06043 Rev. *A