CY7C344
32-Macrocell MAX® EPLD
Features
densest EPLD of this size. Eight dedicated inputs and 16
bidirectional I/O pins communicate to one logic array block. In
the CY7C344 LAB there are 32 macrocells and 64 expander
product terms. When an I/O macrocell is used as an input, two
expanders are used to create an input path. Even if all of the
I/O pins are driven by macrocell registers, there are still 16
“buried” registers available. All inputs, macrocells, and I/O pins
are interconnected within the LAB.
• High-performance, high-density replacement for TTL,
74HC, and custom logic
• 32 macrocells, 64 expander product terms in one LAB
• 8 dedicated inputs, 16 I/O pins
• 0.8-micron double-metal CMOS EPROM technology
The speed and density of the CY7C344 makes it a natural for
all types of applications. With just this one device, the designer
can implement complex state machines, registered logic, and
combinatorial “glue” logic, without using multiple chips. This
architectural flexibility allows the CY7C344 to replace
multichip TTL solutions, whether they are synchronous,
asynchronous, combinatorial, or all three.
• 28-pin, 300-mil DIP, cerDIP or 28-pin HLCC, PLCC
package
Functional Description
Available in a 28-pin, 300-mil DIP or windowed J-leaded
ceramic chip carrier (HLCC), the CY7C344 represents the
Logic Block Diagram [1]
Pin Configurations
HLCC
Top View
INPUT
INPUT
INPUT/CLK 2(9)
27(6)
INPUT
INPUT
13(20)
28(7)
INPUT
INPUT
14(21)
MACROCELL 4
MACROCELL 6
MACROCELL 8
MACROCELL 10
MACROCELL 12
MACROCELL 14
MACROCELL 16
I/O
I/O
I/O
VCC
GND
I/O
I/O
MACROCELL 1
L
O
I/O
4(11)
I/O
5(12)
MACROCELL 7
O
I/O
6(13)
MACROCELL 11
MACROCELL 13
L
3(10)
I
I/O
9(16)
C
O
I/O
10(17)
I/O
11(18)
N
T
I/O
12(19)
I/O
17(24)
R
I/O
18(25)
O
L
I/O
19(26)
I/O
20(27)
MACROCELL 9
B
A
I/O
MACROCELL 5
MACROCELL 3
G
MACROCELL 15
MACROCELL 18
B
MACROCELL 17
MACROCELL 20
U
S
MACROCELL 19
MACROCELL 22
4 3 2 1 28 27 26
MACROCELL 21
MACROCELL 24
MACROCELL 23
MACROCELL 26
MACROCELL 25
I/O
23(2)
MACROCELL 28
MACROCELL 27
I/O
24(3)
MACROCELL 30
MACROCELL 29
I/O
25(4)
MACROCELL 32
MACROCELL 31
I/O
26(5)
64 EXPANDER PRODUCT TERM ARRAY
I/O
INPUT
INPUT
INPUT
INPUT/CLK
I/O
I/O
5
6
7
8
9
10
11
12 13 14 1516 1718
I/O
I/O
MACROCELL 2
1(8)
25
24
23
22
21
20
19
I/O
I/O
INPUT
INPUT
INPUT
INPUT
I/O
I/O
INPUT
15(23)
VCC
GND
I/O
I/O
15(22)
CerDIP
Top View
INPUT
INPUT/CLK
I/O
I/O
I/O
I/O
VCC
GND
I/O
I/O
I/O
I/O
INPUT
INPUT
32
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
27
26
25
24
23
22
21
20
19
18
17
16
15
INPUT
INPUT
I/O
I/O
I/O
I/O
VCC
GND
I/O
I/O
I/O
I/O
INPUT
INPUT
Selection Guide
7C344-15
Maximum Access Time
Maximum Operating Current
Commercial
7C344-20
15
20
25
ns
200
200
mA
220
220
Industrial
220
220
220
Commercial
150
150
150
170
170
170
170
Military
Industrial
Unit
200
Military
Maximum Standby Current
7C344-25
170
mA
Note:
1. Numbers in () refer to J-leaded packages.
Cypress Semiconductor Corporation
Document #: 38-03006 Rev. *B
•
3901 North First Street
•
San Jose, CA 95134
•
408-943-2600
Revised June 6, 2005
USE ULTRA37000TM FOR
ALL NEW DESIGNS
Maximum Ratings
(Above which the useful life may be impaired. For user guidelines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied...................................................0°C to +70°C
Maximum Junction Temperature (Under Bias)............. 150°C
CY7C344
Static Discharge Voltage
(per MIL-STD-883, Method 3015) ............................. >2001V
DC Output Current, per Pin ......................–25 mA to +25 mA
DC Input Voltage[2] .........................................–3.0V to +7.0V
DC Program Voltage................................................... +13.0V
Operating Range
Supply Voltage to Ground Potential ............... –2.0V to +7.0V
Ambient
Temperature
Range
Maximum Power Dissipation...................................1500 mW
Commercial
DC VCC or GND Current ............................................500 mA
Industrial
Military
VCC
0°C to +70°C
5V ±5%
–40°C to +85°C
5V ±10%
–55°C to +125°C (Case)
5V ±10%
[3]
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
Min.
Max.
Unit
VOH
Output HIGH Voltage
VCC = Min., IOH = –4.0 mA
2.4
VOL
Output LOW Voltage
VCC = Min., IOL = 8 mA
0.45
V
VIH
Input HIGH Level
2.2
VCC+0.3
V
VIL
Input LOW Level
–0.3
0.8
V
IIX
Input Current
GND ≤ VIN ≤ VCC
–10
+10
µA
IOZ
Output Leakage Current
VO = VCC or GND
–40
+40
µA
–30
–90
mA
0.5V[4, 5]
V
IOS
Output Short Circuit Current
VCC = Max., VOUT =
ICC1
Power Supply
Current (Standby)
VI = VCC or GND (No
Load)
Commercial
150
mA
Military/Industrial
170
mA
ICC2
Power Supply Current
VI = VCC or GND (No
Load) f = 1.0 MHz[4,6]
Commercial
200
mA
Military/Industrial
220
mA
tR
Recommended Input Rise Time
100
ns
tF
Recommended Input Fall Time
100
ns
Capacitance
Max.
Unit
CIN
Parameter
Input Capacitance
Description
VIN = 2V, f = 1.0 MHz
Test Conditions
10
pF
COUT
Output Capacitance
VOUT = 2.0V, f = 1.0 MHz
10
pF
AC Test Loads and Waveforms[7]
R1 464Ω
5V
R1 464Ω
5V
OUTPUT
ALL INPUT PULSES
OUTPUT
R2
250Ω
50 pF
INCLUDING
JIG AND
SCOPE
Equivalent to:
(a)
3.0V
R2
250Ω
5 pF
GND
≤ 6 ns
90%
10%
90%
10%
tR
tf
tF
≤ 6 ns
(b)
THÉVENIN EQUIVALENT (commercial/military)
163Ω
OUTPUT
1.75V
Notes:
2. Minimum DC input is –0.3V. During transitions, the inputs may undershoot to –2.0V for periods less than 20 ns.
3. Typical values are for TA = 25°C and VCC = 5V.
4. Guaranteed by design but not 100% tested.
5. Not more than one output should be tested at a time. Duration of the short circuit should not be more than one second. VOUT = 0.5V has been chosen to avoid
test problems caused by tester ground degradation.
6. Measured with device programmed as a 16-bit counter.
7. Part (a) in AC Test Load and Waveforms is used for all parameters except tER and tXZ, which is used for part (b) in AC Test Load and Waveforms. All external timing
parameters are measured referenced to external pins of the device.
Document #: 38-03006 Rev. *B
Page 2 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
Timing Delays
Timing delays within the CY7C344 may be easily determined
using Warp®, Warp Professional™, or Warp Enterprise™
software. The CY7C344 has fixed internal delays, allowing the
user to determine the worst case timing delays for any design.
Design Recommendations
Operation of the devices described herein with conditions
above those listed under “Maximum Ratings” may cause
permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other
conditions above those indicated in the operational sections of
this data sheet is not implied. Exposure to absolute maximum
ratings conditions for extended periods of time may affect
device reliability. The CY7C344 contains circuitry to protect
device pins from high-static voltages or electric fields; however,
normal precautions should be taken to avoid applying any
voltage higher than maximum rated voltages.
For proper operation, input and output pins must be
constrained to the range GND ≤ (VIN or VOUT) ≤ VCC. Unused
inputs must always be tied to an appropriate logic level (either VCC or
GND). Each set of VCC and GND pins must be connected together
directly at the device. Power supply decoupling capacitors of at least
0.2 µF must be connected between VCC and GND. For the most
effective decoupling, each VCC pin should be separately decoupled.
Timing Considerations
Unless otherwise stated, propagation delays do not include
expanders. When using expanders, add the maximum
expander delay tEXP to the overall delay.
When calculating synchronous frequencies, use tS1 if all inputs
are on the input pins. tS2 should be used if data is applied at an I/O
pin. If tS2 is greater than tCO1, 1/tS2 becomes the limiting frequency
in the data-path mode unless 1/(tWH + tWL) is less than 1/tS2.
When expander logic is used in the data path, add the appropriate maximum expander delay, tEXP to tS1. Determine which of
1/(tWH + tWL), 1/tCO1, or 1/(tEXP + tS1) is the lowest frequency. The
lowest of these frequencies is the maximum data-path frequency for
the synchronous configuration.
When calculating external asynchronous frequencies, use
tAS1 if all inputs are on dedicated input pins. If any data is applied to
an I/O pin, tAS2 must be used as the required set-up time. If (tAS2 +
tAH) is greater than tACO1, 1/(tAS2 + tAH) becomes the limiting
frequency in the data-path mode unless 1/(tAWH + tAWL) is less than
1/(tAS2 + tAH).
When expander logic is used in the data path, add the appropriate maximum expander delay, tEXP to tAS1. Determine which
of 1/(tAWH + tAWL), 1/tACO1, or 1/(tEXP + tAS1) is the lowest frequency.
The lowest of these frequencies is the maximum data-path frequency
for the asynchronous configuration.
The parameter tOH indicates the system compatibility of this device
when driving other synchronous logic with positive input hold times,
which is controlled by the same synchronous clock. If tOH is greater
than the minimum required input hold time of the subsequent
synchronous logic, then the devices are guaranteed to function
properly with a common synchronous clock under worst-case
environmental and supply voltage conditions.
The parameter tAOH indicates the system compatibility of this
device when driving subsequent registered logic with a positive hold
time and using the same clock as the CY7C344. In general, if tAOH
is greater than the minimum required input hold time of the subsequent logic (synchronous or asynchronous), then the devices are
guaranteed to function properly under worst-case environmental and
supply voltage conditions, provided the clock signal source is the
same. This also applies if expander logic is used in the clock signal
path of the driving device, but not for the driven device. This is due to
the expander logic in the second device’s clock signal path adding an
additional delay (tEXP), causing the output data from the preceding
device to change prior to the arrival of the clock signal at the following
device’s register.
EXPANDER
DELAY
t EXP
REGISTER
LOGIC ARRAY
CONTROLDELAY tCLR
tLAC
tPRE
INPUT
INPUT
DELAY
tIN
CY7C344
LOGIC ARRAY tRSU
DELAY
tRH
tLAD
OUTPUT
DELAY
OUTPUT
tRD
tCOMB
tLATCH
tOD
tXZ
tZX
SYSTEM CLOCK DELAYtICS
I/O
I/O
I/O DELAY
tIO
CLOCK
DELAY
tIC
FEEDBACK
DELAY
tFD
Figure 1. CY7C344 Timing Model
Document #: 38-03006 Rev. *B
Page 3 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
External Synchronous Switching Characteristics Over Operating Range
[7]
7C344-15
Parameter
tPD1
tPD2
Description
Min.
[9]
I/O Input to Combinatorial Output Delay
Min.
Max.
7C344-25
Max.
Unit
15
20
25
ns
Mil
15
20
25
Com’l/Ind
15
20
25
Mil
15
20
25
Dedicated Input to Combinatorial Output Delay[8] Com’l/Ind
Max.
7C344-20
Min.
tPD3
Dedicated Input to Combinatorial Output Delay
with Expander Delay[10]
Com’l/Ind
30
30
40
Mil
30
30
40
tPD4
I/O Input to Combinatorial Output Delay with
Expander Delay[4, 11]
Com’l/Ind
30
30
40
Mil
30
30
40
tEA
Input to Output Enable Delay[4]
Com’l/Ind
20
20
25
Mil
20
20
25
tER
[4]
Com’l/Ind
20
20
25
Mil
20
20
25
Com’l/Ind
10
12
15
Input to Output Disable Delay
tCO1
Synchronous Clock Input to Output Delay
Mil
10
12
15
tCO2
Synchronous Clock to Local Feedback to
Combinatorial Output[4, 12]
Com’l/Ind
20
22
29
tS
Dedicated Input or Feedback Set-Up Time to
Synchronous Clock Input
Com’l/Ind
10
12
15
Mil
10
12
15
tH
Input Hold Time from Synchronous Clock Input[7]
Com’l/Ind
0
0
0
Mil
0
0
0
Com’l/Ind
6
7
8
Mil
6
7
8
Com’l/Ind
6
7
8
tWH
Synchronous Clock Input HIGH Time[4]
tWL
Synchronous Clock Input LOW Time[4]
tRW
Asynchronous Clear Width[4]
tRR
Asynchronous Clear Recovery
Time[4]
Mil
20
22
6
7
8
Com’l/Ind
20
20
25
Mil
20
20
25
Com’l/Ind
20
20
25
Mil
20
20
25
tRO
Asynchronous Clear to Registered Output
Delay[4]
Com’l/Ind
tPW
Asynchronous Preset Width[4]
Com’l /Ind
20
20
25
Mil
20
20
25
tPR
Asynchronous Preset Recovery Time[4]
Com’l /Ind
20
20
25
Mil
20
20
25
Mil
20
15
ns
ns
ns
ns
ns
ns
29
Mil
15
ns
ns
ns
ns
ns
ns
ns
25
20
ns
25
ns
ns
Notes:
8. This parameter is the delay from an input signal applied to a dedicated input pin to a combinatorial output on any output pin. This delay assumes no expander
terms are used to form the logic function.
9. This parameter is the delay associated with an input signal applied to an I/O macrocell pin to any output. This delay assumes no expander terms are used to
form the logic function.
10. This parameter is the delay associated with an input signal applied to a dedicated input pin to combinatorial output on any output pin. This delay assumes
expander terms are used to form the logic function and includes the worst-case expander logic delay for one pass through the expander logic. This parameter
is tested periodically by sampling production material.
11. This parameter is the delay associated with an input signal applied to an I/O macrocell pin to any output pin. This delay assumes expander terms are used to
form the logic function and includes the worst-case expander logic delay for one pass through the expander logic. This parameter is tested periodically by
sampling production material.
12. This specification is a measure of the delay from synchronous register clock input to internal feedback of the register output signal to a combinatorial output for
which the registered output signal is used as an input. This parameter assumes no expanders are used in the logic of the combinatorial output and the register
is synchronously clocked. This parameter is tested periodically by sampling production material.
Document #: 38-03006 Rev. *B
Page 4 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
External Synchronous Switching Characteristics Over Operating Range (continued)[7]
7C344-15
Parameter
Description
Min.
tPO
Asynchronous Preset to Registered Output
Delay[4]
tCF
Synchronous Clock to Local Feedback Input[4, 13] Com’l /Ind
tP
External Synchronous Clock Period (1/fMAX3)[4]
fMAX1
External Maximum Frequency(1/(tCO1 + tS))
7C344-20
Min.
Max.
7C344-25
Min.
Unit
ns
15
20
25
Mil
15
20
25
4
4
7
4
4
ns
7
Com’l/Ind
13
14
16
Mil
13
14
16
Com’l/Ind
50.0
41.6
33.3
Mil
50.0
41.6
33.3
fMAX2
Maximum Frequency with Internal Only
Feedback (1/(tCF + tS))[4, 15]
Com’l/Ind
71.4
62.5
45.4
Mil
71.4
62.5
45.4
fMAX3
Data Path Maximum Frequency, least of
1/(tWL + tWH), 1/(tS + tH), or (1/tCO1)[4, 16]
Com’l/Ind
83.3
71.4
62.5
Mil
83.3
71.4
62.5
fMAX4
Maximum Register Toggle Frequency
1/(tWL + tWH)[4, 17]
Com’l/Ind
83.3
71.4
62.5
Mil
83.3
71.4
62.5
Output Data Stable Time from Synchronous
Clock Input[4, 18]
Com’l/Ind
3
3
3
Mil
3
3
3
tOH
Max.
Com’l /Ind
Mil
[4, 14]
Max.
ns
MHz
MHz
MHz
MHz
ns
Notes:
13. This specification is a measure of the delay associated with the internal register feedback path. This delay plus the register set-up time, tS, is the minimum internal
period for an internal state machine configuration. This parameter is tested periodically by sampling production material.
14. This specification indicates the guaranteed maximum frequency at which a state machine configuration with external only feedback can operate.
15. This specification indicates the guaranteed maximum frequency at which a state machine with internal-only feedback can operate. If register output states must
also control external points, this frequency can still be observed as long as it is less than 1/tCO1. This specification assumes no expander logic is used. This parameter
is tested periodically by sampling production material.
16. This frequency indicates the maximum frequency at which the device may operate in data-path mode (dedicated input pin to output pin). This assumes that no
expander logic is used.
17. This specification indicates the guaranteed maximum frequency in synchronous mode, at which an individual output or buried register can be cycled by a clock
signal applied to either a dedicated input pin or an I/O pin.
18. This parameter indicates the minimum time after a synchronous register clock input that the previous register output data is maintained on the output pin.
Document #: 38-03006 Rev. *B
Page 5 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
External Asynchronous Switching Characteristics Over Operating Range[7]
7C344-15
Parameter
tACO1
Description
Asynchronous Clock Input to Output Delay
7C344-20
7C344-25
Min. Max. Min. Max. Min. Max.
Com’l/Ind
15
20
25
Mil
15
20
25
30
30
37
tACO2
Asynchronous Clock Input to Local Feedback to
Combinatorial Output[19]
Com’l/Ind
tAS
Dedicated Input or Feedback Set-Up Time to
Asynchronous Clock Input
Com’l/Ind
7
9
12
Mil
7
9
12
tAH
Input Hold Time from Asynchronous Clock Input
Com’l/Ind
7
9
12
Mil
7
9
12
tAWH
Asynchronous Clock Input HIGH Time[4, 20]
Com’l/Ind
6
7
9
Mil
6
7
9
Com’l/Ind
7
9
11
Mil
7
Time[4]
tAWL
Asynchronous Clock Input LOW
tACF
Asynchronous Clock to Local Feedback Input[4, 21]
(1/fMAX4)[4]
Mil
30
30
9
ns
ns
ns
11
18
21
Mil
18
18
21
Com’l/Ind
fMAXA1
External Maximum Frequency in Asynchronous
Mode 1/(tACO1 + tAS)[4, 22]
16
20
Com’l/Ind
13
16
20
45.4
34.4
27
Mil
45.4
34.4
27
fMAXA2
Maximum Internal Asynchronous Frequency
1/(tACF + tAS) or 1/(tAWH + tAWL)[4, 23]
Com’l/Ind
40
37
30.3
fMAXA3
Data Path Maximum Frequency in Asynchronous
Mode[4, 24]
Com’l/Ind
40
37
30.3
66.6
50
40
Mil
66.6
50
40
fMAXA4
Maximum Asynchronous Register Toggle
Frequency 1/(tAWH + tAWL)[4, 25]
Com’l/Ind
76.9
62.5
50
tAOH
Output Data Stable Time from Asynchronous Clock Com’l/Ind
Input[4, 26]
Mil
Mil
76.9
62.5
50
15
15
15
15
15
15
Mil
Mil
13
ns
ns
18
External Asynchronous Clock Period
ns
37
Com’l/Ind
tAP
Unit
ns
ns
MHz
MHz
MHz
MHz
ns
Notes:
19. This specification is a measure of the delay from an asynchronous register clock input to internal feedback of the registered output signal to a combinatorial
output for which the registered output signal is used as an input. Assumes no expanders are used in logic of combinatorial output or the asynchronous clock
input. This parameter is tested periodically by sampling production material.
20. This parameter is measured with a positive-edge-triggered clock at the register. For negative edge triggering, the tAWH and tAWL parameters must be swapped. If a
given input is used to clock multiple registers with both positive and negative polarity, tAWH should be used for both tAWH and tAWL.
21. This specification is a measure of the delay associated with the internal register feedback path for an asynchronously clocked register. This delay plus the
asynchronous register set-up time, tAS, is the minimum internal period for an asynchronously clocked state machine configuration. This delay assumes no expander logic in
the asynchronous clock path. This parameter is tested periodically by sampling production material.
22. This parameter indicates the guaranteed maximum frequency at which an asynchronously clocked state machine configuration with external feedback can
operate. It is assumed that no expander logic is employed in the clock signal path or data path.
23. This specification indicates the guaranteed maximum frequency at which an asynchronously clocked state machine with internal-only feedback can operate. If
register output states must also control external points, this frequency can still be observed as long as this frequency is less than 1/tACO1. This specification assumes
no expander logic is utilized. This parameter is tested periodically by sampling production material.
24. This specification indicates the guaranteed maximum frequency at which an individual output or buried register can be cycled in asynchronously clocked mode.
This frequency is least of 1/(tAWH + tAWL), 1/(tAS + tAH), or 1/tACO1. It also indicates the maximum frequency at which the device may operate in the asynchronously clocked
data-path mode. Assumes no expander logic is used.
25. This specification indicates the guaranteed maximum frequency at which an individual output or buried register can be cycled in asynchronously clocked mode
by a clock signal applied to an external dedicated input or an I/O pin.
26. This parameter indicates the minimum time that the previous register output data is maintained on the output pin after an asynchronous register clock input to
an external dedicated input or I/O pin.
Document #: 38-03006 Rev. *B
Page 6 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Typical Internal Switching Characteristics Over Operating Range[7]
7C344-15
Parameter
tIN
Description
Dedicated Input Pad and Buffer Delay
tIO
I/O Input Pad and Buffer Delay
tEXP
Expander Array Delay
tLAD
Logic Array Data Delay
tLAC
Logic Array Control Delay
tOD
tZX
tXZ
Output Buffer and Pad Delay
Output Buffer Enable Delay[27]
Output Buffer Disable Delay
Min.
Max.
7C344-20
Min.
Max.
7C344-25
Min.
Max.
Unit
ns
Com’l/Ind
4
5
7
Mil
4
5
7
Com’l/Ind
4
5
7
Mil
4
5
7
Com’l/Ind
8
10
15
Mil
8
10
15
Com’l/Ind
7
9
10
Mil
7
9
10
Com’l/Ind
5
7
7
Mil
5
7
7
Com’l/Ind
4
5
5
Mil
4
5
5
Com’l/Ind
7
8
11
Mil
7
8
11
Com’l/Ind
7
8
11
Mil
7
8
11
tRSU
Register Set-Up Time Relative to Clock Signal
at Register
Com’l/Ind
5
5
Mil
5
5
8
tRH
Register Hold Time Relative to Clock Signal at
Register
Com’l/Ind
7
9
12
Mil
7
tLATCH
Flow-Through Latch Delay
Com’l/Ind
1
1
3
Mil
1
1
3
tRD
Register Delay
Com’l/Ind
1
1
1
Mil
1
1
1
Com’l/Ind
1
1
3
Mil
1
1
3
tCOMB
tCH
Transparent Mode
Delay[28]
Clock HIGH Time
tCL
Clock LOW Time
tIC
Asynchronous Clock Logic Delay
tICS
Synchronous Clock Delay
tFD
Feedback Delay
tPRE
Asynchronous Register Preset Time
8
9
ns
ns
ns
ns
ns
ns
ns
ns
ns
12
Com’l/Ind
6
7
8
Mil
6
7
8
Com’l/Ind
6
7
8
Mil
6
7
ns
ns
ns
ns
ns
8
Com’l/Ind
7
8
10
Mil
7
8
10
Com’l/Ind
1
2
3
Mil
1
2
3
Com’l/Ind
1
1
1
Mil
1
1
1
Com’l/Ind
5
6
9
Mil
5
6
9
ns
ns
ns
ns
Notes:
27. Sample tested only for an output change of 500 mV.
28. This specification guarantees the maximum combinatorial delay associated with the macrocell register bypass when the macrocell is configured for combinatorial
operation.
Document #: 38-03006 Rev. *B
Page 7 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Typical Internal Switching Characteristics Over Operating Range[7] (continued)
7C344-15
Parameter
Description
Min.
tCLR
Asynchronous Register Clear Time
Com’l/Ind
tPCW
Asynchronous Preset and Clear Pulse Width
Max.
Min.
5
Mil
tPCR
7C344-20
Max.
7C344-25
Min.
6
5
6
5
5
7
Mil
5
5
7
5
5
7
5
5
7
Mil
Unit
9
ns
9
Com’l/Ind
Asynchronous Preset and Clear Recovery Time Com’l/Ind
Max.
ns
ns
Switching Waveforms
External Combinatorial
DEDICATED INPUT/
I/O INPUT
tPD1/tPD2
COMBINATORIAL
OUTPUT
tER
COMBINATORIAL OR
REGISTERED OUTPUT
HIGH-IMPEDANCE
THREE-STATE
tEA
HIGH-IMPEDANCE
THREE-STATE
VALID OUTPUT
External Synchronous
DEDICATED INPUTS OR
REGISTERED FEEDBACK
tS
tH
tWH
tWL
SYNCHRONOUS
CLOCK
tCO1
ASYNCHRONOUS
CLEAR/PRESET
tRW/tPW
tRR/tPR
tOH
tRO/tPO
REGISTERED
OUTPUTS
tCO2
COMBINATORIAL OUTPUT FROM
REGISTERED FEEDBACK [12]
Document #: 38-03006 Rev. *B
Page 8 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Switching Waveforms (continued)
External Asynchronous
DEDICATED INPUTS OR
REGISTERED FEEDBACK
tAH
tAS
ASYNCHRONOUS
CLOCK INPUT
ASYNCHRONOUS
CLEAR/PRESET
tACO1
tAWH
tRW/tPW
tAWL
tRR/tPR
tAOH
tRO/tPO
ASYNCHRONOUS REGISTERED
OUTPUTS
tACO2
COMBINATORIAL OUTPUT FROM
ASYNCH. REGISTERED
FEEDBACK [19]
Internal Combinatorial
tIN
INPUT PIN
tIO
tPIA
I/O PIN
tEXP
EXPANDER
ARRAY DELAY
tLAC, tLAD
LOGIC ARRAY
INPUT
LOGIC ARRAY
OUTPUT
Document #: 38-03006 Rev. *B
Page 9 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Switching Waveforms (continued)
Internal Asynchronous
tAWH
tIOtR
tAWL
tF
CLOCK PIN
tIN
CLOCK INTO
LOGIC ARRAY
tIC
CLOCK FROM
LOGIC ARRAY
tRSU
tRH
DATA FROM
LOGIC ARRAY
tRD,tLATCH
tFD
REGISTER OUTPUT
TO LOCAL LAB
LOGIC ARRAY
tCLR,tPRE
tFD
tPIA
REGISTER OUTPUT
TO ANOTHER LAB
Internal Synchronous (Input Path)
tCH
tCL
SYSTEM CLOCK PIN
tIN
tICS
tRSU
tRH
SYSTEM CLOCK
AT REGISTER
DATA FROM
LOGIC ARRAY
Internal Synchronous (Output Path)
CLOCK FROM
LOGIC ARRAY
tRD
tOD
DATA FROM
LOGIC ARRAY
tXZ
OUTPUT PIN
Document #: 38-03006 Rev. *B
tZX
HIGH Z
Page 10 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Ordering Information
Speed
(ns)
15
20
25
Ordering Code
CY7C344-15HC/HI
Package
Name
H64
28-Lead Windowed Leaded Chip Carrier
CY7C344-15JC/JI
J64
28-Lead Plastic Leaded Chip Carrier
CY7C344-15PC/PI
P21
28-Lead (300-Mil) Molded DIP
CY7C344-15WC/WI
W22
28-Lead Windowed CerDIP
CY7C344-20HC/HI
H64
28-Lead Windowed Leaded Chip Carrier
CY7C344-20JC/JI
J64
28-Lead Plastic Leaded Chip Carrier
CY7C344-20PC/PI
P21
28-Lead (300-Mil) Molded DIP
CY7C344-20WC/WI
W22
28-Lead Windowed CerDIP
CY7C344-20HMB
H64
28-Lead Windowed Leaded Chip Carrier
CY7C344-20WMB
W22
28-Lead Windowed CerDIP
CY7C344-25HC/HI
H64
28-Lead Windowed Leaded Chip Carrier
CY7C344-25JC/JI
J64
28-Lead Plastic Leaded Chip Carrier
CY7C344-25PC/PI
P21
28-Lead (300-Mil) Molded DIP
CY7C344-25WC/WI
W22
28-Lead Windowed CerDIP
CY7C344-25HMB
H64
28-Lead Windowed Leaded Chip Carrier
CY7C344-25WMB
W22
28-Lead Windowed CerDIP
MILITARY SPECIFICATIONS
Group A Subgroup Testing
Commercial/Industrial
Commercial/Industrial
Military
Commercial/Industrial
Military
Switching Characteristics
Parameter
DC Characteristics
Parameter
Operating
Range
Package Type
tPD1
7, 8, 9, 10, 11
tPD2
7, 8, 9, 10, 11
tPD3
7, 8, 9, 10, 11
VOH
1, 2, 3
tCO1
7, 8, 9, 10, 11
VOL
1, 2, 3
tS
7, 8, 9, 10, 11
VIH
1, 2, 3
tH
7, 8, 9, 10, 11
VIL
1, 2, 3
tACO1
7, 8, 9, 10, 11
IIX
1, 2, 3
tACO1
7, 8, 9, 10, 11
IOZ
1, 2, 3
tAS
7, 8, 9, 10, 11
ICC1
1, 2, 3
tAH
7, 8, 9, 10, 11
Document #: 38-03006 Rev. *B
Subgroups
Subgroups
Page 11 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Package Diagrams
28-Pin Windowed Leaded Chip Carrier H64
51-80077-**
Document #: 38-03006 Rev. *B
Page 12 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Package Diagrams (continued)
28-Lead Plastic Leaded Chip Carrier J64
51-85001-*A
28-Lead (300-Mil) PDIP P21
SEE LEAD END OPTION
14
1
DIMENSIONS IN INCHES [MM] MIN.
MAX.
REFERENCE JEDEC MO-095
0.260[6.60]
0.295[7.49]
15
28
PACKAGE WEIGHT: 2.15 gms
0.030[0.76]
0.080[2.03]
SEATING PLANE
1.345[34.16]
1.385[35.18]
0.290[7.36]
0.325[8.25]
0.120[3.05]
0.140[3.55]
0.140[3.55]
0.190[4.82]
0.115[2.92]
0.160[4.06]
0.015[0.38]
0.060[1.52]
0.090[2.28]
0.110[2.79]
0.009[0.23]
0.012[0.30]
0.055[1.39]
0.065[1.65]
0.015[0.38]
0.020[0.50]
LEAD END OPTION
3° MIN.
0.310[7.87]
0.385[9.78]
SEE LEAD END OPTION
51-85014-*D
(LEAD #1, 14, 15 & 28)
Document #: 38-03006 Rev. *B
Page 13 of 15
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Package Diagrams (continued)
28-Lead (300-Mil) Windowed CerDIP W22
MIL-STD-1835 D-15 Config. A
51-80087-**
MAX and Warp are registered trademarks and Ultra37000, Warp Professional and Warp Enterprise are trademarks of Cypress
Semiconductor Corporation. All products and company names mentioned in this document may be the trademarks of their respective
holders.
Document #: 38-03006 Rev. *B
Page 14 of 15
© Cypress Semiconductor Corporation, 2005. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be
used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its
products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
USE ULTRA37000TM FOR
ALL NEW DESIGNS
CY7C344
Document History Page
Document Title: CY7C344 32-Macrocell MAX® EPLD
Document Number: 38-03006
REV.
ECN NO.
Issue Date
Orig. of
Change
Description of Change
**
106271
04/19/01
SZV
Change from Spec number: 38-00127 to 38-03006
*A
213375
See ECN
FSG
Added note to title page: “Use Ultra37000 For All New Designs”
*B
373715
See ECN
PCX
Corrected header information
Document #: 38-03006 Rev. *B