ETC2 IDT5T9306NLGI 2.5v lvds 1:6 clock buffer terabufferâ ¢ ii Datasheet

2.5V LVDS 1:6 Clock Buffer
Terabuffer™ II
IDT5T9306
DATA SHEET
DESCRIPTION:
FEATURES:
•
•
•
•
•
•
•
•
•
•
•
•
The IDT5T9306 2.5V differential clock buffer is a user-selectable differential
input to six LVDS outputs. The fanout from a differential input to six LVDS outputs
reduces loading on the preceding driver and provides an efficient clock
distribution network. The IDT5T9306 can act as a translator from a differential
HSTL, eHSTL, LVEPECL (2.5V), LVPECL (3.3V), CML, or LVDS input to
LVDS outputs. A single-ended 3.3V / 2.5V LVTTL input can also be used to
translate to LVDS outputs. The redundant input capability allows for an
asynchronous change-over from a primary clock source to a secondary clock
source. Selectable reference inputs are controlled by SEL.
The IDT5T9306 outputs can be asynchronously enabled/disabled. When
disabled, the outputs will drive to the value selected by the GL pin. Multiple power
and grounds reduce noise.
Guaranteed Low Skew < 25ps (max)
Very low duty cycle distortion < 125ps (max)
High speed propagation delay < 1.75ns (max)
Additive phase jitter, RMS 0.159ps (typical) @ 125MHz
Up to 1GHz operation
Selectable inputs
Hot insertable and over-voltage tolerant inputs
3.3V / 2.5V LVTTL, HSTL, eHSTL, LVEPECL (2.5V), LVPECL (3.3V),
CML, or LVDS input interface
Selectable differential inputs to six LVDS outputs
Power-down mode
2.5V VDD
Available in VFQFPN package
APPLICATIONS:
• Clock distribution
FUNCTIONAL BLOCK DIAGRAM
GL
G
PD
A1
A2
0
SEL
IDT5T9306 REVISION B JANUARY 31, 2011
Q1
OUTPUT
CONTROL
Q2
OUTPUT
CONTROL
Q3
OUTPUT
CONTROL
Q4
OUTPUT
CONTROL
Q5
OUTPUT
CONTROL
Q6
Q1
Q2
1
A1
A2
OUTPUT
CONTROL
1
Q3
Q4
Q5
Q6
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
NC
Q5
Q5
Q6
Q6
VDD
SEL
PIN CONFIGURATION
28 27 26 25 24 23 22
G
1
21
PD
VDD
2
20
VDD
Q1
3
19
Q4
Q1
4
18
Q4
VDD
5
17
VDD
A1
6
16
A2
A1
7
15
A2
Q2
VDD
VDD
Q3
10 11 12 13 14
Q3
9
Q2
8
GL
GND
VFQFPN
TOP VIEW
IDT5T9306 REVISION B JANUARY 31, 2011
2
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
CAPACITANCE(1)
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Max
Unit
VDD
Power Supply Voltage
Description
–0.5 to +3.6
V
VI
Input Voltage
–0.5 to +3.6
V
VO
Output Voltage(2)
–0.5 to VDD +0.5
V
TSTG
Storage Temperature
–65 to +150
°C
TJ
Junction Temperature
150
°C
Symbol
CIN
(TA = +25°C, F = 1.0MHz)
Parameter
Min
Typ.
Max.
Unit
Input Capacitance
—
—
3
pF
NOTE:
1. This parameter is measured at characterization but not tested
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
2. Not to exceed 3.6V.
RECOMMENDED OPERATING RANGE
Symbol
TA
VDD
Description
Ambient Operating Temperature
Internal Power Supply Voltage
Min.
–40
2.3
Typ.
+25
2.5
Max.
+85
2.7
Unit
°C
V
PIN DESCRIPTION
Symbol
A[1:2]
A[1:2]
I/O
I
I
Type
Adjustable(1,4)
Adjustable(1,4)
G
I
LVTTL
GL
I
LVTTL
Qn
Qn
SEL
PD
O
O
I
I
LVDS
LVDS
LVTTL
LVTTL
VDD
GND
NC
PWR
PWR
Description
Clock input. A[1:2] is the "true" side of the differential clock input.
Complementary clock inputs. A[1:2] is the complementary side of A[1:2]. For LVTTL single-ended operation, A[1:2] should be set to the
desired toggle voltage for A[1:2]:
3.3V LVTTL VREF = 1650mV
2.5V LVTTL VREF = 1250mV
Gate control for differential outputs Q1 and Q1 through Q6 and Q6. When G is LOW, the differential outputs are active. When G is
HIGH, the differential outputs are asynchronously driven to the level designated by GL(2).
Specifies output disable level. If HIGH, "true" outputs disable HIGH and "complementary" outputs disable LOW. If LOW, "true"
outputs disable LOW and "complementary" outputs disable HIGH.
Clock outputs
Complementary clock outputs
Reference clock select. When LOW, selects A2 and A2. When HIGH, selects A1 and A1.
Power-down control. Shuts off entire chip. If LOW, the device goes into low power mode. Inputs and outputs are disabled. Both
"true" and "complementary" outputs will pull to VDD. Set HIGH for normal operation.(3)
Power supply for the device core and inputs
Power supply return for all power
No connect; recommended to connect to GND
NOTES:
1. Inputs are capable of translating the following interface standards:
Single-ended 3.3V and 2.5V LVTTL levels
Differential HSTL and eHSTL levels
Differential LVEPECL (2.5V) and LVPECL (3.3V) levels
Differential LVDS levels
Differential CML levels
2. Because the gate controls are asynchronous, runt pulses are possible. It is the user's responsibility to either time the gate control signals to minimize the possibility of runt
pulses or be able to tolerate them in down stream circuitry.
3. It is recommended that the outputs be disabled before entering power-down mode. It is also recommended that the outputs remain disabled until the device completes powerup after asserting PD.
4. The user must take precautions with any differential input interface standard being used in order to prevent instability when there is no input signal.
IDT5T9306 REVISION B JANUARY 31, 2011
3
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE FOR LVTTL(1)
Symbol
Parameter
Input Characteristics
IIH
Input HIGH Current
IIL
Input LOW Current
VIK
Clamp Diode Voltage
VIN
DC Input Voltage
VIH
DC Input HIGH
VIL
DC Input LOW
VTHI
DC Input Threshold Crossing Voltage
Single-Ended Reference Voltage(3)
VREF
Test Conditions
VDD = 2.7V
VDD = 2.7V
VDD = 2.3V, IIN = -18mA
3.3V LVTTL
2.5V LVTTL
Min.
Typ.(2)
Max
Unit
—
—
—
- 0.3
1.7
—
—
—
—
—
—
- 0.7
—
—
—
VDD /2
1.65
1.25
±5
±5
- 1.2
+3.6
—
0.7
—
—
—
μA
V
V
V
V
V
V
NOTES:
1. See RECOMMENDED OPERATING RANGE table.
2. Typical values are at VDD = 2.5V, +25°C ambient.
3. For A[1:2] single-ended operation, A[1:2] is tied to a DC reference voltage.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE FOR
DIFFERENTIAL INPUTS(1)
Symbol
Parameter
Input Characteristics
IIH
Input HIGH Current
IIL
Input LOW Current
VIK
Clamp Diode Voltage
VIN
DC Input Voltage
VDIF
DC Differential Voltage(3)
VCM
DC Common Mode Input Voltage(4)
Test Conditions
VDD = 2.7V
VDD = 2.7V
VDD = 2.3V, IIN = -18mA
Min.
Typ.(2)
Max
Unit
—
—
—
- 0.3
0.1
0.05
—
—
- 0.7
—
—
—
±5
±5
- 1.2
+3.6
—
VDD
μA
V
V
V
V
NOTES:
1. See RECOMMENDED OPERATING RANGE table.
2. Typical values are at VDD = 2.5V, +25°C ambient.
3. VDIF specifies the minimum input differential voltage (VTR - VCP) required for switching where VTR is the "true" input level and VCP is the "complement" input level. The DC differential
voltage must be maintained to guarantee retaining the existing HIGH or LOW input. The AC differential voltage must be achieved to guarantee switching to a new state.
4. VCM specifies the maximum allowable range of (VTR + VCP) /2.
DC ELECTRICAL CHARACTERISTICS OVER RECOMMENDED OPERATING
RANGE FOR LVDS(1)
Symbol
Parameter
Output Characteristics
VOT(+)
Differential Output Voltage for the True Binary State
VOT(-)
Differential Output Voltage for the False Binary State
ΔVOT
Change in VOT Between Complementary Output States
VOS
Output Common Mode Voltage (Offset Voltage)
ΔVOS
Change in VOS Between Complementary Output States
IOS
Outputs Short Circuit Current
Differential Outputs Short Circuit Current
IOSD
Test Conditions
Min.
Typ.(2)
Max
Unit
VOUT + and VOUT - = 0V
VOUT + = VOUT -
247
247
—
1.125
—
—
—
—
—
—
1.2
—
12
6
454
454
50
1.375
50
24
12
mV
mV
mV
V
mV
mA
mA
NOTES:
1. See RECOMMENDED OPERATING RANGE table.
2. Typical values are at VDD = 2.5V, TA = +25°C ambient.
IDT5T9306 REVISION B JANUARY 31, 2011
4
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
DIFFERENTIAL INPUT AC TEST CONDITIONS FOR HSTL
Symbol
Parameter
VDIF
Input Signal Swing(1)
Value
Units
1
V
VX
Differential Input Signal Crossing Point
750
mV
DH
Duty Cycle
50
%
VTHI
Input Timing Measurement Reference Level
tR, tF
Input Signal Edge Rate(4)
(2)
(3)
Crossing Point
V
2
V/ns
NOTES:
1. The 1V peak-to-peak input pulse level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VDIF (AC)
specification under actual use conditions.
2. A 750mV crossing point level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VX specification under
actual use conditions.
3. In all cases, input waveform timing is marked at the differential cross-point of the input signals.
4. The input signal edge rate of 2V/ns or greater is to be maintained in the 20% to 80% range of the input waveform.
DIFFERENTIAL INPUT AC TEST CONDITIONS FOR eHSTL
Symbol
Parameter
VDIF
Input Signal Swing(1)
Value
Units
1
V
VX
Differential Input Signal Crossing Point
900
mV
DH
Duty Cycle
50
%
VTHI
Input Timing Measurement Reference Level
tR, tF
Input Signal Edge Rate(4)
(2)
(3)
Crossing Point
V
2
V/ns
NOTES:
1. The 1V peak-to-peak input pulse level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VDIF (AC)
specification under actual use conditions.
2. A 900mV crossing point level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VX specification under
actual use conditions.
3. In all cases, input waveform timing is marked at the differential cross-point of the input signals.
4. The input signal edge rate of 2V/ns or greater is to be maintained in the 20% to 80% range of the input waveform.
DIFFERENTIAL INPUT AC TEST CONDITIONS FOR LVEPECL (2.5V) AND
LVPECL (3.3V)
Symbol
Parameter
VDIF
Input Signal Swing
VX
Differential Input Signal Crossing Point(2)
DH
Duty Cycle
VTHI
Input Timing Measurement Reference Level
tR, tF
Input Signal Edge Rate(4)
Value
Units
732
mV
LVEPECL
1082
mV
LVPECL
1880
(1)
50
(3)
%
Crossing Point
V
2
V/ns
NOTES:
1. The 732mV peak-to-peak input pulse level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VDIF (AC)
specification under actual use conditions.
2. 1082mV LVEPECL (2.5V) and 1880mV LVPECL (3.3V) crossing point levels are specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment.
This device meets the VX specification under actual use conditions.
3. In all cases, input waveform timing is marked at the differential cross-point of the input signals.
4. The input signal edge rate of 2V/ns or greater is to be maintained in the 20% to 80% range of the input waveform.
IDT5T9306 REVISION B JANUARY 31, 2011
5
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
DIFFERENTIAL INPUT AC TEST CONDITIONS FOR LVDS
Symbol
Parameter
VDIF
Input Signal Swing(1)
VX
Differential Input Signal Crossing Point
DH
Duty Cycle
VTHI
Input Timing Measurement Reference Level(3)
tR, tF
Input Signal Edge Rate(4)
Value
Units
400
mV
(2)
1.2
V
50
%
Crossing Point
V
2
V/ns
NOTES:
1. The 400mV peak-to-peak input pulse level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VDIF (AC)
specification under actual use conditions.
2. A 1.2V crossing point level is specified to allow consistent, repeatable results in an automatic test equipment (ATE) environment. This device meets the VX specification under
actual use conditions.
3. In all cases, input waveform timing is marked at the differential cross-point of the input signals.
4. The input signal edge rate of 2V/ns or greater is to be maintained in the 20% to 80% range of the input waveform.
AC DIFFERENTIAL INPUT SPECIFICATIONS(1)
Symbol
Parameter
Min.
Typ.
Max
Unit
VDIF
AC Differential Voltage(2)
0.1
—
3.6
V
VIX
VCM
Differential Input Crosspoint Voltage
Common Mode Input Voltage Range(3)
0.05
0.05
—
—
VDD
VDD
V
V
VIN
Input Voltage
- 0.3
+3.6
V
NOTES:
1. The output will not change state until the inputs have crossed and the minimum differential voltage range defined by VDIF has been met or exceeded.
2. VDIF specifies the minimum input voltage (VTR - VCP) required for switching where VTR is the "true" input level and VCP is the "complement" input level. The AC differential voltage
must be achieved to guarantee switching to a new state.
3. VCM specifies the maximum allowable range of (VTR + VCP) /2.
POWER SUPPLY CHARACTERISTICS FOR LVDS OUTPUTS(1)
Symbol
IDDQ
ITOT
IPD
Parameter
Quiescent VDD Power Supply Current
Total Power VDD Supply Current
Total Power Down Supply Current
Test Conditions
VDD = Max., All Input Clocks = LOW(2)
Outputs enabled
VDD = 2.7V., FREFERENCE CLOCK = 1GHz
PD = LOW
Typ.
—
Max
240
Unit
mA
—
—
250
5
mA
mA
NOTES:
1. These power consumption characteristics are for all the valid input interfaces and cover the worst case conditions.
2. The true input is held LOW and the complementary input is held HIGH.
IDT5T9306 REVISION B JANUARY 31, 2011
6
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
AC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE(1,5)
Symbol
Skew Parameters
tSK(O)
tSK(P)
tSK(PP)
Propagation Delay
tPLH
tPHL
Parameter
Min.
Typ.
Max
Unit
Same Device Output Pin-to-Pin Skew(2)
Pulse Skew(3)
—
—
—
—
25
125
ps
ps
Part-to-Part Skew(4)
—
—
300
ps
Propagation Delay A, A Crosspoint to Qn, Qn Crosspoint
—
1.25
1.75
ns
—
—
1
GHz
Output Gate Enable Crossing VTHI to Qn/Qn Crosspoint
—
—
3.5
ns
Output Gate Disable Crossing VTHI to Qn/Qn Crosspoint Driven to GL Designated Level
—
—
3.5
ns
—
—
—
—
100
100
μS
μS
fO
Frequency Range(6)
Output Gate Enable/Disable Delay
tPGE
tPGD
Power Down Timing
tPWRDN
PD Crossing VTHI to Qn = VDD, Qn = VDD
Output Gate Disable Crossing VTHI to Qn/Qn Driven to GL Designated Level
tPWRUP
RMS Additive Phase Jitter
RMS Additive Phase Jitter @ 25MHz (12kHz – 10MHz Integration Range)
tJIT
0.541
ps
RMS Additive Phase Jitter @ 125MHz (12kHz – 20MHz Integration Range)
0.159
ps
RMS Additive Phase Jitter @ 156.25MHz (12kHz – 20MHz Integration Range)
0.185
ps
Output Rise/Fall Time
tR/tF
Output Rise/Fall Time(6), (20% - 80%)
125
600
ps
NOTES:
1. AC propagation measurements should not be taken within the first 100 cycles of startup.
2. Skew measured between crosspoints of all differential output pairs under identical input and output interfaces, transitions and load conditions on any one device.
3. Skew measured is the difference between propagation delay times tPHL and tPLH of any differential output pair under identical input and output interfaces, transitions and load conditions
on any one device.
4. Skew measured is the magnitude of the difference in propagation times between any single differential output pair of two devices, given identical transitions and load conditions
at identical VDD levels and temperature.
5. All parameters are tested with a 50% input duty cycle.
6. Guaranteed by design but not production tested.
IDT5T9306 REVISION B JANUARY 31, 2011
7
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
DIFFERENTIAL AC TIMING WAVEFORMS
1/fo
+ VDIF
VDIF = 0
- VDIF
A[1:2] - A[1:2]
tPHL
tPLH
+ VDIF
VDIF = 0
- VDIF
Qn - Qn
tSK(O)
tSK(O)
+ VDIF
VDIF = 0
- VDIF
Qm - Qm
Output Propagation and Skew Waveforms
NOTES:
1. Pulse skew is calculated using the following expression:
tSK(P) = | tPHL - tPLH |
Note that the tPHL and tPLH shown above are not valid measurements for this calculation because they are not taken from the same pulse.
2. AC propagation measurements should not be taken within the first 100 cycles of startup.
IDT5T9306 REVISION B JANUARY 31, 2011
8
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
+ VDIF
VDIF = 0
- VDIF
A[1:2] - A[1:2]
VIH
VTHI
VIL
GL
tPLH
VIH
VTHI
VIL
G
tPGD
tPGE
+ VDIF
VDIF = 0
- VDIF
Qn - Qn
Differential Gate Disable/Enable Showing Runt Pulse Generation
NOTE:
1. As shown, it is possible to generate runt pulses on gate disable and enable of the outputs. It is the user's responsibility to time the G signal to avoid this problem.
A1 - A1
+VDIF
VDIF=0
-VDIF
A2 - A2
+VDIF
VDIF=0
-VDIF
G
VIH
VTHI
VIL
PD
VIH
VTHI
VIL
+VDIF
VDIF=0
-VDIF
Qn - Qn
Power Down Timing
NOTES:
1. It is recommended that outputs be disabled before entering power-down mode. It is also recommended that the outputs remain disabled until the device completes power-up after
asserting PD.
2. The POWER DOWN TIMING diagram assumes that GL is HIGH.
3. It should be noted that during power-down mode, the outputs are both pulled to VDD. In the POWER DOWN TIMING diagram this is shown when Qn-Qn goes to VDIF = 0.
IDT5T9306 REVISION B JANUARY 31, 2011
9
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
TEST CIRCUITS AND CONDITIONS
VIN
~50
Transmission Line
VDD/2
A
D.U.T.
Pulse
Generator
VIN
A
~50
Transmission Line
-VDD/2
Scope
50
50
Test Circuit for Differential Input
DIFFERENTIAL INPUT TEST CONDITIONS
IDT5T9306 REVISION B JANUARY 31, 2011
Symbol
VDD = 2.5V ± 0.2V
Unit
VTHI
Crossing of A and A
V
10
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
VDD
A
Pulse
Generator
Qn
RL
A
D.U.T.
VOS
VOD
RL
Qn
Test Circuit for DC Outputs and Power Down Tests
VDD/2
SCOPE
CL
Z = 50
Pulse
Generator
A
Qn
50
A
D.U.T.
50
Qn
Z = 50
CL
-VDD/2
Test Circuit for Propagation, Skew, and Gate Enable/Disable Timing
LVDS OUTPUT TEST CONDITION
Symbol
VDD = 2.5V ± 0.2V
Unit
CL
0(1)
8(1,2)
pF
RL
50
Ω
NOTES:
1. Specifications only apply to "Normal Operations" test condition. The TIA/EIA specification load is for reference only.
2. The scope inputs are assumed to have a 2pF load to ground. TIA/EIA - 644 specifies 5pF between the output pair. With CL = 8pF, this gives the test circuit appropriate 5pF equivalent
load.
IDT5T9306 REVISION B JANUARY 31, 2011
11
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
VFQFPN EPAD THERMAL RELEASE PATH
In order to maximize both the removal of heat from the package and the
“heat pipes”) are application specific and dependent upon the package
power dissipation as well as electrical conductivity requirements. Thus,
thermal and electrical analysis and/or testing are recommended to determine
the minimum number needed. Maximum thermal and electrical performance
is achieved when an array of vias is incorporated in the land pattern. It is
recommended to use as many vias connected to ground as possible. It is
also recommended that the via diameter should be 12 to 13mils (0.30 to
0.33mm) with 1oz copper via barrel plating. This is desirable to avoid any
solder wicking inside the via during the soldering process which may result
in voids in solder between the exposed pad/slug and the thermal land.
Precautions should be taken to eliminate any solder voids between the
exposed heat slug and the land pattern. Note: These recommendations are
to be used as a guideline only. For further information, refer to the Application
Note on the Surface Mount Assembly of Amkor’s Thermally/Electrically
Enhance Leadframe Base Package, Amkor Technology.
electrical performance, a land pattern must be incorporated on the Printed
Circuit Board (PCB) within the footprint of the package corresponding to the
exposed metal pad or exposed heat slug on the package, as shown in
Figure 1. The solderable area on the PCB, as defined by the solder mask,
should be at least the same size/shape as the exposed pad/slug area on the
package to maximize the thermal/electrical performance. Sufficient clearance
should be designed on the PCB between the outer edges of the land pattern
and the inner edges of pad pattern for the leads to avoid any shorts.
While the land pattern on the PCB provides a means of heat transfer and
electrical grounding from the package to the board through a solder joint,
thermal vias are necessary to effectively conduct from the surface of the PCB
to the ground plane(s). The land pattern must be connected to ground
through these vias. The vias act as “heat pipes”. The number of vias (i.e.
PIN
PIN PAD
SOLDER
EXPOSED HEAT SLUG
GROUND PLANE
SOLDER
PIN
LAND PATTERN
THERMAL VIA
PIN PAD
(GROUND PAD)
FIGURE 1. P.C.ASSEMBLY FOR EXPOSED PAD THERMAL RELEASE PATH –SIDE VIEW (DRAWING NOT TO SCALE)
IDT5T9306 REVISION B JANUARY 31, 2011
12
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
RECOMMENDED LANDING PATTERN
NL 28 pin
NOTE:
All dimensions are in millimeters.
IDT5T9306 REVISION B JANUARY 31, 2011
13
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
July 23, 2002
October 8, 2002
October 10, 2002
October 24, 2002
November 1, 2002
December 12, 2002
December 16, 2002
May 8, 2003
August 7, 2003
October 2, 2003
March 26, 2004
June 22, 2004
October 26, 2004
October 27, 2004
October 29, 2004
March 9, 2005
October 23, 2007
April 15, 2008
January 31, 2011
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
Datasheet creation
Page 1, entire page changed; page 2, both diagrams; page 3, Pin Description and notes; page 4, DC Cha. for LVPECL
and Differential Input tables; page 6, DC Cha. and Power Supply tables; page 7, entire page; page 9, added note 3;
page 10, entire page; page 10, entire page; page 11, entire page; page 12, Ordering Info; added 3 new pages (10 thru
12) of diagrams.
Page 1, entire page changed; page 2, both diagrams; page 3, Pin Description and notes; page 7, AC Cha. table; page
8, added new LVPECL table; page 10, removed Input Clock Switching diagram; page 11, deleted entire page; page
12, changed Power Down Timing; page 15, Ordering Info.
Page 2, added note 1 to TQFP TOP VIEW text; page3, aded note 4 to Pin Description; page 4, replaced "Compliant devices
must meet" with the text "This device meets" in four instances; page 5, Differential Input table, note 1, changed 1V
to 732mV and replaced "Compliant devices must meet" with the text "This device meets"; page 6, DC Electrical table,
Vdif row, changed Min. value to 0.1, and under Differential Input table replaced "Compliant devices must meet" with
the text "This device meets" page 7, Power Supply table, replaced ((TBD)) with 800MHz, and under AC Electrical table,
replaced ((TBD)) with 500; page 8, completely altered AC DIfferential table; page 12, LVDS Output table, replaced ((TBD))
with 3.
Radical changes to entire document.
Radical changes to entire document, using 5T9316 as a base.
Throughout document, removed "Differential" from title; page 7, Power Supply table, changed Max values, changed
FREFERENCE value; page 10, note 1, changed Gx to G.
Page 2, corrected pinout diagram.
Page 1, Features text, 3rd bullet, changed 2ns to 1.75ns, 4th bullet, changed 800MHz to 1GHz, and 7th bullet, added
CML, on Description, 3rd line, added CML to list; page 4, Pin Descr., note 1, added "Differential CML levels", for
Description of PD row, replaced 2nd sentence with "Both 'true' and 'complementary' output will pull to Vdd"; page
5, DC... for Differential Inputs table, removed note 5 and changed Vcm Max. from 3.5 to Vdd; page 7, Power Supply table,
changed 800MHz to 1GHz; page 8, AC Differential table, changed Vix and Vcm Max specs from 3.5V to Vdd, removed
notes 4 and 5, and placed entire table on page 7, for AC Elect. table, added notes 5 and 6, changed ((TBD)) to 300ps,
tplh Type to 1.25ns, and Max from 2ns to 1.75ns, and changed fo Max from 800MHz to 1GHz.
Page 1, Features, 7th bullet, added "3.3V / 2,5V LVTTL" to front, Description, added to 1st paragraph "A single-ended
3.3V / 2.5V LVTTL input can also be used to translate to LVDS outputs."; page 4, Pin Description table, added large
block of text to 2nd row, added "Single-ended 3.3V and 2.5V LVTTL levels" to note 1; page 5, DC for LVTTL table, added
Vref row and note 3, for DC for LVDS table, changed Ios ratings from 5 Typ, 7.5 Max to 12 Typ, 24 Max, and changed
Iosd ratings from 5 Typ, 7.5 Max to 6 Typ, 12 Max; page 7, Power Supply table, changed Ipd from 3 to 5.
Page 2, changed pin 22 to NC; page 3, changed pin 25 to NC; page 4, added NC row to Pin Description.
Removed TQFP package.
Inserted a page before Ordering Info and added Landing Pattern.
Added note to Landing Pattern.
Changed landing pattern diagram.
Page 6, switched Iddq and Itot values.
Page 7, added Additive Phase Jitter, RMS specs to the AC Electrical Characterisitcs Table.
Page 7, added Rise/Fall Time spec. to the AC Electrical Characteristics Table.
Page 12, added VFQFPN Thermal Release Path application note.
Updated to header/footer to new format.
IDT5T9306 REVISION B JANUARY 31, 2011
14
©2011 Integrated Device Technology, Inc.
IDT5T9306 Data Sheet
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
ORDERING INFORMATION
IDT
XXXXX
Device Type
XX
Package
X
Process
IDT5T9306 REVISION B JANUARY 31, 2011
I
-40°C to +85°C (Industrial)
NL
Thermally Enhanced Plastic Very Fine Pitch
Quad Flat No Lead Package
5T9306
2.5V 1:6 LVDS Clock Buffer Terabuffer™ II
15
©2011 Integrated Device Technology, Inc.
IDT5T9306
Data Sheet
IDT5T9306
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
2.5V LVDS 1:6 CLOCK BUFFER TERABUFFER™ II
We've GotYourTiming Solution
6024 Silver Creek Valley Road
San Jose, CA 95138
Sales
800-345-7015 (inside USA)
+408-284-8200 (outside USA)
Fax: 408-284-2775
www.IDT.com/go/contactIDT
Techical Support
[email protected]
+480-763-2056
DISCLAIMER Integrated Device Technology, Inc. (IDT) and its subsidiaries reserve the right to modify the products and/or specifications described herein at any time and at IDT’s sole discretion. All information
in this document, including descriptions of product features and performace, is subject to change without notice. Performance specifications and the operating parameters of the described products are
determined in the independent state and are not guaranteed to perform the same way when installed in customer products. The information contained herein is provided without representation or warranty of any
kind, whether express or implied, including, but not limited to, the suitablity of IDT’s products for any particular purpose, an implied warranty of merchantability, or non-infringement of the intellectual property
rights of others. This document is presented only as a guide and does not convey any license under intellectual property rights of IDT or any third parties.
IDT’s products are not intended for use in life support systems or similar devices where the failure or malfunction of an IDT product can be reasonably expected to significantly affect the health or safety of users.
Anyone using an IDT product in such a manner does so at their own risk, absent an express, written agreement by IDT.
Integrated Device Techology, IDT and the IDT logo are registered trademarks of IDT. Other trademarks and service marks used herein, including protected names, logos and designs, are the property of IDT or
their respective third party owners.
Copyright 2011. All rights reserved.
Similar pages