MCC MP356

MCC
!"#
$
% !"#
Features
•
•
•
•
MP3505
THRU
MP3510
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Mounting Hole For #8 Screw
Plastic Case With Metal Bottom
Any Mounting Position
Surge Rating Of 400 Amps
MP-50
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
Device
Marking
MP3505
MP351
MP352
MP354
MP356
MP358
MP3510
MP3505
MP351
MP352
MP354
MP356
MP358
MP3510
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000v
B
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000v
35V
70V
140V
280V
420V
560V
700V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
2
I t Rating for Fusing
t<8.3mS
IF(AV)
35.0A
TC = 55°C
IFSM
400A
8.3ms, half sine
C
E
G
+
AC
D
H
-
A
AC
J
VF
1.1V
IR
5µA
500µA
2
It
IFM = 17.5A per
element;
TJ = 25°C
TJ = 25°C
TJ = 125°C
660
Typical Themal
R jc
Resistance Junction
3.0
to case(per element)
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
2
AS
K/W
A
DIMENSIONS
DIM
A
B
C
D
E
G
H
J
INCHES
MIN
1.118
.432
.468
.689
.618
.193
.618
.531
MAX
1.130
.442
.558
.728
.657
--.657
.571
www.mccsemi.com
MM
MIN
28.40
10.97
11.89
17.50
15.70
4.90
15.70
13.50
MAX
28.70
11.23
14.17
18.50
16.70
--16.70
14.50
NOTE
∅
MCC
MP3505 thru MP3510
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
20
2
1
10
.6
6
.4
4
.2
2
TJ=25°C
25°C
µAmps .1
1
Amps
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.4
.6
.8
1.0
1.2
40
60
80
100
120
140
1.4
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
60
600
50
500
40
400
300
30
Amps
Amps
200
20
100
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
0
150
1
2
4
Average Forward Rectified Current - Amperesversus
Case Temperature - °C
8 10
20
40
00
60 80 100
Cycles
175
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com