Radial Leaded PPTC FRH Series RoHS ü FEATURES AGENCY RECOGNITION •Low hold current, Solid state Radial-leaded product ideal for •UL (E211981) •C-UL (E211981) •TÜV (R50004084) up to 60V/250V/600V •Application: Telecommunication and Data transmitting •Operation Current: 0.08A ~ 0.18A •Maximum Voltage: 60V/250V/600V •Temperature Range: -40°C to 85°C ELECTRICAL CHARACTERISTICS (23°C) Part Number Hold Current Trip Current Max. Time Maximum to Trip Current Max. Oper. Voltage Max. Int. Voltage Resistance Tolerance RMIN R1MAX IH, A IT, A A Sec IMAX, A VMAX, VDC VI-MAX, V OHMS OHMS FRH080-250UF 0.08 0.16 0.35 4.0 3.0 60 250 14.0 33.0 FRH080-250F 0.08 0.16 0.35 4.0 3.0 60 250 14.0 33.0 FRH110-250UF 0.11 0.22 1.0 2.0 3.0 60 250 5.0 16.0 FRH110-250F 0.11 0.22 1.0 2.0 3.0 60 250 5.0 16.0 FRH120-250UF 0.12 0.24 1.0 2.0 3.0 60 250 6.0 16.0 FRH120-250F 0.12 0.24 1.0 2.0 3.0 60 250 4.0 16.0 FRH145-250UF 0.15 0.29 1.0 2.5 3.0 60 250 3.5 12.0 FRH145-250F 0.15 0.29 1.0 2.5 3.0 60 250 3.0 12.0 FRH180-250UF 0.18 0.65 1.5 10.0 10.0 60 250 0.8 4.0 FRH180-250F 0.18 0.65 1.5 11.0 10.0 60 250 0.8 4.0 FRH150-600F 0.15 0.30 1.0 5.0 3.0 60 600 6.0 22.0 FRH160-600F 0.16 0.32 1.0 7.0 3.0 60 600 4.0 18.0 IH=Hold current-maximum current at which the device will not trip at 23°C still air. IT=Trip current-maximum current at which the device will always trip at 23°C still air. V MAX=Maximum voltage device can withstand without damage at its rated current. VI-MAX=Maximum interrupt voltage device can withstand for short period of time. (Not for long term.) I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX). Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment. R MIN=Minimum device resistance at 23°C. R1MAX=Maximum device resistance at 23°C, 1 hour after tripping. Physical specifications: Lead material: FRH080-250~FRH180-250 Tin plated copper, 22 AWG. FRH150-600~FRH160-600 Tin plated copper, 22 AWG. Soldering characteristics: MIL-STD-202, Method 208E. Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement. Figure 1 FRH PRODUCT DIMENSIONS (MILLIMETERS) NOTE: All FRH products are designed to assist equipment to pass ITU, UL1950 or GR1089 specification. Part A Number B C D E Maximum Maximum Typical Minimum Maximum FRH080-250UF 4.8 9.1 5 4.7 3.8 FRH080-250F 5.3 9.6 5 4.7 4.6 FRH110-250UF 5.3 9.4 5 4.7 3.8 FRH110-250F 5.8 9.9 5 4.7 4.6 FRH120-250UF 6.0 10.0 5 4.7 3.8 FRH120-250F 6.5 11.0 5 4.7 4.6 FRH145-250UF 6.0 10.0 5 4.7 3.8 FRH145-250F 6.5 11.0 5 4.7 4.6 FRH180-250UF 10.4 12.6 5 4.7 3.8 FRH180-250F 10.9 13.6 5 4.7 4.6 FRH150-600F 13.5 12.6 5 4.7 6 FRH160-600F 16.0 12.6 5 4.7 6 Lead Size: 22AWG (0.65mm) Figure 2 Lead Size: 22AWG (0.65mm) CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above. RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C5EB08 REV 2007.03.1 Radial Leaded PPTC FRH Series RoHS ü THERMAL DERATING CURVE Percent of Rated Hold and Trip Current Thermal Derating Curve - FRH Series 200% 150% 100% 50% 0% -40 -20 0 20 40 60 80 Ambient Temperature (C) TYPICAL TIME-TO-TRIP AT 23°C 1000 Time-to-trip (S) 100 10 G E F D C B A 1 0.1 A= B= C= D= E= F= G= FRH080(U)-250 FRH110(U)-250 FRH120(U)-250 FRH145(U)-250 FRH180(U)-250 FRH150-600 FRH160-600 0.01 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 Fault current (A ) CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above. NOTE: All Specification subject to change without notice. RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C5EB08 REV 2007.03.1