Series 1 - 110/125A
120/240, 480 Vac • AC Output
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• Internal Snubber
A24110
D24110
A24125
D24125
HA48110
HD48110
HA48125
HD48125
24-280
24-280
48-530
48-530
Max. Load Current ➂ [Arms]
110
125
110
125
Min. Load Current, [mArms]
150
150
150
150
Transient Overvoltage [Vpk]
600
600
1200
1200
1500
1750
1500
1750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (RθJC) [˚C/W]
.25
.22
.25
.22
9,340
12,700
9,340
12,700
10
10
10
10
500
500
500
500
MODEL NUMBERS
AC CONTROL
D C C ONTROL
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and versions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Surge Current, (16.6ms) [Apk]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
0.5
0.5
0.5
DC CONTROL
AC CONTROL
AC CONTROL
(D PREFIX)
(A PREFIX)
(E SUFFIX)
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
Nominal Input Impedance
1500 Ohms (120/240V Models) ➄
60K Ohms
9.0K Ohms
Typical Input Current
3.4mA @ 5 Vdc, 20mA @ 28Vdc➄
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
GENERAL NOTES
©1998 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➄ Input circuitry for 480V models incorporates active current limiter with 2mA typical input current..
FastFax Document No. 152
110/125.040898, PAGE 1 OF 2
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
9002
Series 1 - 110/125A
120/240, 480 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
E
24 Vac Input (18-36 Vac)
Example: A24110E
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D24110-10
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
8-32 TERMINAL
(2 PLACES )
OUTPUT
1
1.87
(47.5)
2
SOLID-STATE RELAY
--
+
4
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
2.30
(58.4)
1.70
(43.2)
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
All dimensions are in inches (millimeters)
.78
(19.8)
.90
(22.9)
6-32 TERMINAL
(2 PLACES)
CURRENT DERATING CURVES
110A
125A
160
120
.5ºC/W
100
80
1ºC/W
110
40
90
.4ºC/W
Power Dissipation
Power Dissipation
.2ºC/W
Base Plate Temp [ºC]
90
.4ºC/W
120
.5ºC/W
.2ºC/W
100
80
1ºC/W
110
40
120
0
Base Plate Temp [ºC]
160
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116950
FastFax Document No. 152
110/125.040898, PAGE 2 OF 2
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
9002
Similar pages