MCC MUR10005CT THRU omponents 21201 Itasca Street Chatsworth !"# $ % !"# MUR10060CT Features • • • • • 100 Amp Supre Fast Recovery Rectifier 50 to 600 Volts Supre Fast switching for high efficiency High Surge Capability Low Leakage Low Forward Voltage Drop High Current Capability Maximum Ratings • • FULL PACK Operating Temperature: -65°C to +175°C Storage Temperature: -65°C to +175°C MCC Part Number MUR10005CT MUR10010CT MUR10020CT MUR10040CT MUR10060CT Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 40V 280V 420V 50V 100V 200V 400V 600V A B K C M J F L D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage 10005-10020 10040-10060 Maximum DC Reverse Current At Rated DC Blocking Voltage Maximum Reverse Recovery Time 10005-10020 10040-10060 Typical Junction Capacitance IF(AV) 100 A IFSM 400A TL = 140°C 8.3ms, half sine 1.10V 1.35V Trr CJ 25 µA 50ns 75ns 240pF E G IFM = 50.0A; TA = 25°C VF IR H TA = 25°C DIMENSIONS DIM A B C E F G H J K L L INCH ES MIN MAX 3.150 NOM 1.565 1.585 .700 .800 .119 .132 1.375 REF 3.55 3.65 .590 .620 1/4 - UNF .380 .410 .185 .195 .275 .295 IF=0.5A, IR=1.0A, Irr=0.25A Measured at 1.0MHz, VR=4.0V *Pulse Test: Pulse Width 300µsec, Duty Cycle 1% www.mccsemi.com MM MIN MAX 80.01 NOM 39.75 40.26 17.78 20.32 3.02 3.35 34.92 REF 90.17 92.71 14.99 15.75 FULL 9.65 10.41 4.70 4.95 6.99 7.49 NOTE ∅ ∅ ∅ MCC MUR10005CT thru MUR10060CT Figure 1 Typical Forward Characteristics 200 10040-10060 10005-10020 Figure 2 Forward Derating Curve 100 120 60 40 100 20 25°C 80 Amps 10 6 60 Amps 4 40 2 20 1 .6 0 .4 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 125 150 175 °C .2 .1 0.8 0.6 1.0 1.2 Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 1.6 1.4 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 1000 600 400 200 pF TJ=25°C 100 60 40 20 10 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pF versus Reverse Voltage - Volts www.mccsemi.com 1000 MCC MUR10005CT thru MUR10060CT Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 500 5000 4000 2000 400 1000 300 100 200 60 Amps 40 100 50 25 0 TA=125°C µAmps 10 1 2 4 6 40 60 80 100 Cycles 6 Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles 4 2 1 .6 .4 TA=25°C .2 .1 8 10 20 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts www.mccsemi.com