ILPA100VU SERIES 100W Water-Proof Constant Voltage LED Driver – – – – – – – 3 Year Warranty Wide Input Voltage 90 to 305VAC, 47 to 63Hz Constant Output Voltage Available From 12VDC Thru 105VDC Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection High Efficiency (up to 93%) Active Power Factor Correction (PFC) (99% typical) IP67 Waterproof Rating, Metal Housing Comply with UL8750 & EN61347 Safety Regulation (Pending) Approvals: Single Output Part Number Output Voltage ILPA100VU-S012ST ILPA100VU-S024ST ILPA100VU-S036ST ILPA100VU-S042ST ILPA100VU-S048ST ILPA100VU-S054ST ILPA100VU-S081ST ILPA100VU-S105ST 12 VDC 24 VDC 36 VDC 42 VDC 48 VDC 54 VDC 81 VDC 105 VDC Max. Output Current 8.33 A 4.05A 2.75 A 2.25 A 1.95 A 1.75 A 1.23 A 0.95 A Efficiency Over Voltage Protection (220VAC, Full Load) Min / Typ / Max 91% 14V / 15V / 16V 93% 27V / 30V / 34V 93% 40V / 47V / 50V 93% 47V / 52V / 57V 92% 54V / 59V / 63V 93% 60V / 68V / 75V 93% 91V / 95V / 100V 93% 120V / 125V / 140V Max. Output Power 100W 100W 100W 100W 100W 100W 100W 100W Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Power Factor Correction Power Factor Correction Efficiency No-Load Power Consumption Line Regulation Load Regulation Over Voltage Protection Over Current Protection Over Temperature Protection Short Circuit Protection Output Overshoot / Undershoot Start Up Time Ripple & Noise (Peak to Peak) Test Conditions Operating Voltage Min. 90 47 0 Typ. Max. 305 63 100 1.20 0.60 65 Unit VAC Hz W A A A % % % W % % Vin=90 to 264VAC Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, 25°C, Cool start, Vin=230VAC Vin=110VAC 99 Vin=220VAC 96 Io=Full Load, Vin=230VAC 93 No Load, VIn=230VAC 1.5 Io=Full Load 1 Vin=230VAC 2 Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) 110 135 180 % Io 110 °C No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. When power on or off 10 % Io=Full Load, Vin=100VAC 3 S Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 2 % Vo uF electrolytic capacitor. Conditions Parameter Test Conditions Min. Operating Temperature Storage Temperature Relative Humidity Operation temperature at 25°C, calculated per MIL-HDBK-217F Life Time at 25°C ambient temperature No output power derating from -35°C to 60°C -35 -40 5 0.439M 0.193M Typ. Max. Unit 70 85 95 °C °C % Hours Hours Approvals and Compliance Parameter EMI EMS Safety UL/c-UL, T-mark, CE Waterproof Standards EN55015 EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 IP67 Rating Mechanical Parameter Dimension, Net Weight Input Electric Wire Output Electric Wire Specification 184x67.5x37mm (7.24x2.66x1.46 inches), 950g approx. 650mm, Black(ACL), White(ACN), Green(GND) 220mm, Red(V+), Black(V-)