MCC MUR20005CT THRU omponents 21201 Itasca Street Chatsworth !"# $ % !"# MUR20060CT Features • • • • • 200 Amp Supre Fast Recovery Rectifier 50 to 600 Volts Supre Fast switching for high efficiency High Surge Capability Low Leakage Low Forward Voltage Drop High Current Capability Maximum Ratings • • FULL PACK Operating Temperature: -55°C to +175°C Storage Temperature: -55°C to +175°C MCC Part Number MUR20005CT MUR20010CT MUR20020CT MUR20040CT MUR20060CT Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 40V 280V 420V 50V 100V 200V 400V 600V A B K C M F J L D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage 20005CT-20020CT 20040CT-20060CT Maximum DC Reverse Current At Rated DC Blocking Voltage Maximum Reverse Recovery Time 20005CT-20020CT 20040CT 20060CT Typical Junction Capacitance 20005CT-20020CT 20040CT 20060CT IF(AV) 200 A H TC= 135°C E G IFSM 800A 8.3ms, half sine DIMENSIONS VF IR 1.25V 1.75V IFM = 100.0A; TJ = 25°C 50 µA TJ = 25°C 6 mA TJ = 125°C T rr 60ns 75ns 90ns CJ 575pF 300pF 275pF DIM A B C D E F G H J K L M INCH ES MIN MAX 3.150 NOM 1.565 1.585 .700 .800 2.400 2.500 .119 .132 1.375 REF 3.550 3.650 .580 .620 1/4 -20 UNF .380 .410 .185 .195 .275 .295 IF=0.5A, IR=1.0A, Irr=0.25A Measured at 1.0MHz, VR=10V *Pulse Test: Pulse Width 300µsec, Duty Cycle 2% www.mccsemi.com MM MIN MAX 80.01 NOM 39.75 40.26 17.78 20.32 60.96 63.50 3.02 3.35 34.92 REF 90.17 92.71 14.73 15.75 FULL 9.65 10.41 4.70 4.95 6.99 7.49 NOTE ∅ ∅ ∅ MCC MUR20005CT thru MUR20060CT Figure 1 Typical Forward Characteristics 200 20040CT-20060CT 20005CT-20020CT Figure 2 Forward Derating Curve 100 220 60 40 200 20 25°C 180 Amps 10 6 160 Amps 4 140 2 120 1 .6 0 .4 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 100 150 200 150 °C .2 .1 0.8 0.6 1.0 1.2 Average Forward Rectified Current - Amperes versus Case Temperature - °C 1.6 1.4 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 1000 800 400 200 pF TJ=25°C 20005CT-20020CT 100 20040CT 60 40 20060CT 20 10 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pF versus Reverse Voltage - Volts www.mccsemi.com 1000 MCC MUR20005CT thru MUR20060CT Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 1000 5000 4000 2000 800 1000 600 100 400 70 Amps 60 200 100 50 0 TJ=125°C µAmps 10 1 2 4 6 40 60 80 100 Cycles 6 Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles 4 2 1 .6 .4 TJ=25°C .2 .1 8 10 20 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts www.mccsemi.com