MCC MUR20005CT

MCC
MUR20005CT
THRU
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
MUR20060CT
Features
•
•
•
•
•
200 Amp Supre Fast
Recovery Rectifier
50 to 600 Volts
Supre Fast switching for high efficiency
High Surge Capability
Low Leakage
Low Forward Voltage Drop
High Current Capability
Maximum Ratings
•
•
FULL PACK
Operating Temperature: -55°C to +175°C
Storage Temperature: -55°C to +175°C
MCC
Part Number
MUR20005CT
MUR20010CT
MUR20020CT
MUR20040CT
MUR20060CT
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
35V
70V
40V
280V
420V
50V
100V
200V
400V
600V
A
B
K
C
M
F
J
L
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
20005CT-20020CT
20040CT-20060CT
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
20005CT-20020CT
20040CT
20060CT
Typical Junction
Capacitance
20005CT-20020CT
20040CT
20060CT
IF(AV)
200 A
H
TC= 135°C
E
G
IFSM
800A
8.3ms, half sine
DIMENSIONS
VF
IR
1.25V
1.75V
IFM = 100.0A;
TJ = 25°C
50 µA TJ = 25°C
6 mA TJ = 125°C
T rr
60ns
75ns
90ns
CJ
575pF
300pF
275pF
DIM
A
B
C
D
E
F
G
H
J
K
L
M
INCH ES
MIN
MAX
3.150
NOM
1.565
1.585
.700
.800
2.400
2.500
.119
.132
1.375 REF
3.550
3.650
.580
.620
1/4 -20 UNF
.380
.410
.185
.195
.275
.295
IF=0.5A, IR=1.0A,
Irr=0.25A
Measured at
1.0MHz, VR=10V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
www.mccsemi.com
MM
MIN
MAX
80.01
NOM
39.75
40.26
17.78
20.32
60.96
63.50
3.02
3.35
34.92 REF
90.17
92.71
14.73
15.75
FULL
9.65
10.41
4.70
4.95
6.99
7.49
NOTE
∅
∅
∅
MCC
MUR20005CT thru MUR20060CT
Figure 1
Typical Forward Characteristics
200
20040CT-20060CT
20005CT-20020CT
Figure 2
Forward Derating Curve
100
220
60
40
200
20
25°C
180
Amps 10
6
160
Amps
4
140
2
120
1
.6
0
.4
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
100
150
200
150
°C
.2
.1
0.8
0.6
1.0
1.2
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
1.6
1.4
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
1000
800
400
200
pF
TJ=25°C
20005CT-20020CT
100
20040CT
60
40
20060CT
20
10
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
MUR20005CT thru MUR20060CT
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
1000
5000
4000
2000
800
1000
600
100
400
70
Amps
60
200
100
50
0
TJ=125°C
µAmps 10
1
2
4
6
40
60 80 100
Cycles
6
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
4
2
1
.6
.4
TJ=25°C
.2
.1
8 10 20
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com