Obsolescence Notice This product is obsolete. This information is available for your convenience only. For more information on Zarlink’s obsolete products and replacement product lists, please visit http://products.zarlink.com/obsolete_products/ MVTX1100 9-Port Home PNA Packet Concentrator Data Sheet Features November 2003 • 8 1/10 Mbps Serial ports direct interface with Home PNA PHY or 8 10/100 Mbps RMII ports • Ideal for MDU (Multiple Dwelling Unit) application with Home PNA PHY • 1 10/100 Mbps auto-negotiating MII/serial port (port 8) that can be used as uplink port • Up to 8 port-based VLANs can be configured from EEPROM • Ability to support WinSock 2.0 and Windows 98 & Windows 2000 smart applications • Internal 1 k MAC address table • Transmit delay control capabilities • - Auto address learning - Auto address aging Ordering Information MVTX1100AL 208 Pin PQFP -40°C to +85°C - Provides maximum delay guarantee (<1 ms)(Last bit in to first bit out) - Supports mixed voice-data networks Leading edge QoS capabilities provided based on 802.1 p and IP TOS/DS field • Support Concentrator mode - 2 queues per output port • - Packet scheduling based on Weighted RoundRobin (WRR) Ports 0 & 1 can be trunked to provide a 2x1/10 Mbps link to another switch or server • - Weighted Random Early Detection/Drop (WRED) to drop packets during traffic congestion Utilizes a single low-cost external pipelined, SyncBurst SRAM (SBRAM) for buffer memory • External I2C EEPROM for power-up configuration 2 levels of packet drop provided • Support external parallel port for configuration updates • Optimized pin-out for easy board layout • Packaged in a 208 PQFP • Supports both Full/Half duplex ports • Full wire-speed layer 2 switching on all ports S S R A M - MVTX1100 9-Port Home PNA Packet Concentrator 56 k bytes or 512 k bytes (1 chip) 10/100 MII CPU 1/10MB* Serial Interface Home PNA PHY Home PNA PHY 8 Port Home PNA + 1-Port MII Switch * also supports 10/100MB RMII Interface Figure 1 - System Block Diagram 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003, Zarlink Semiconductor Inc. All Rights Reserved. MVTX1100 Data Sheet Description The MVTX1100 is a fully integrated 9-port Ethernet packet concentrator designed to support Home Networking. It is ideal for Multiple Dwelling Units (MDU) application. The MVTX1100 provides features normally not associated with plug-and-play technology without requiring an external processor to facilitate their utilization. The MVTX1100 begins operating immediately at power-up, learning addresses automatically and forwarding packets at full wire speed to any of its 8 output ports or the uplink expansion port. At power-up, MVTX1100 configures itself from the EEPROM, and can then provide port trunking, port-based VLANs, and Quality of Service (QoS) capabilities, usually associated only with managed switches. The proprietary built-in intelligence of the MVTX1100 allows it to recognize and offer packet prioritization QoS. Packets are prioritized based on their layer 2 VLAN priority tag or layer 3 Type-Of Service/ Differentiated Services (TOS/DS) field. This priority can be defined as transmit and/or drop priority. The MVTX1100 can be used to create an 8-port unmanaged switch with one WAN router port by adding a CPU (ARM or MPC 850) connected to the additional MII port (port 8). The only external components needed for a low cost MDU system are the Home PNA physical layer transceivers and a single SBRAM per MVTX1100. Operating at 50 MHz internally, and with a 50 MHz interface to the external SBRAM, the MVTX1100 sustains full wire-speed switching on all 9 ports. When the system supports 8 ports of 1 M Home PNA PHY with the 10M Serial uplink, the system clock can be operated to 20 MHz and still achieve full wire-speed switching on all nine ports. The chip is packaged in a small 208 pin Plastic Quad Flat-Pak (PQFP) package. 2 Zarlink Semiconductor Inc. MVTX1100 Data Sheet LA_[6] VSS L_A[5] L_A[4] L_A[3] L_A[18] VDD L_D[31] L_D[30] L_D[29] VSS (CORE) L_D[28] L_D[27] L_D[26] VDD L_D[25] L_D[24] L_D[23] L_D[22] VSS L_D[21] L_D[20] L_D[19] L_D[18] VDD (CORE) L_D[17] L_D[16] L_D[15] VSS L_D[14] L_D[13] L_D[12] L_D[11] VDD L_D[10] L_D[9] L_D[8] VSS (CORE) L_D[7] L_D[6] L_D[5] L_D[4] VDD L_D[3] L_D[2] L_D[1] VSS L_D[0] L_A[15] VDD (CORE) L_A[16] L_ADSC# MVTX1100 Physical Pinout 208 206 204 202 200 198 196 194 192 190 188 186 184 182 180 178 176 174 172 170 168 166 164 162 160 158 2 4 + 154 Buffer Mem Interface 152 Pin 1 I.D. 6 156 150 8 148 10 146 12 144 14 Config Interfaces 142 18 20 22 24 26 28 30 RMII Port Interfaces 16 140 138 136 134 132 130 128 126 32 124 34 122 36 120 MII Port Interfaces 38 40 42 44 46 48 50 RMII Port Interfaces 118 116 114 112 110 108 106 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 M4_CLS M4_LINK M4_DUPLEX M5_CLS M5_LINK M5_DUPLEX VDD M4_TXEN M4_TXD M4_TXCLK M4_CRS_DV M4_RXD M4_RXCLK VSS M5_TXEN M5_TXD M5_TXCLK M5_CRS_DV M5_RXD M5_RXCLK VDD (CORE) M6_TXEN M6_TXD M6_TXCLK M6_CRS_DV M6_RXD M6_RXCLK VSS (CORE) M7_TXEN M7_TXD M7_TXCLK M7_CRS_DV M7_RXD M7_RXCLK VDD M6_CLS M6_LINK M6_DUPLEX M7_CLS M7_LINK M7_DUPLEX VSS M_CLK VDD (CORE) M8_RXDV M8_COL VSS M8_RXCLK VDD M8_RXD[0] M8_RXD[1] M8_RXD[2] L_A[7] L_A[8] VDD_CORE L_A[9] L_A[10] L_A[11] VSS L_A[12] L_A[13] L_A[14] VDD M0_CLS M0_LINK M0_DUPLEX M1_CLS M1_LINK M1_DUPLEX VSS (CORE) M0_TXEN M0_TXD M0_TXCLK M0_CRS_DV M0_RXD M0_RXCLK VDD M1_TXEN M1_TXD M1_TXCLK M1_CRS_DV M1_RXD M1_RXCLK VSS M2_TXEN M2_TXD M2_TXCLK M2_CRS_DV M2_RXD M2_RXCLK VDD (CORE) M3_TXEN M3_TXD M3_TXCLK M3_CRS_DV M3_RXD M3_RXCLK VSS (CORE) M2_CLS M2_LINK M2_DUPLEX M3_CLS M3_LINK M3_DUPLEX 3 Zarlink Semiconductor Inc. L_OE# L_WE# VSS L_CLK VDD L_A[17] L_A[2] VSS SCLK VDD MIR_CTL[3] MIR_CTL[2] MIR_CTL[1] MIR_CTL[0] RSTIN# RSTOUT# VSS (CORE) T_MODE TSTOUT[7] TSTOUT[6] TSTOUT[5] TSTOUT[4] TSTOUT[3] TSTOUT[2] TSTOUT[1] TSTOUT[0] VDD (CORE) ACK DATA0 STROBE TRUNK_EN TEST# SDA SCL M_MDIO VSS M_MDC VDD M8_REFCLK VSS M8_SPEED M8_DUPLEX M8_LINK M8_TXD[3] M8_TXD[2] M8_TXD[1] M8_TXD[0] M8_TXEN VDD M8_TXCLK VSS (CORE) M8_RXD[3] MVTX1100 Pin Reference Table Pin # Pin Name 1 L_A[7] 2 L_A[8] 3 VDD (CORE) 4 L_A[9] 5 L_A[10] 6 L_A[11] 7 VSS 8 L_A[12] 9 L_A[13] 10 L_A[14] 11 VDD 12 M0_CLS 13 M0_LINK 14 M0_DUPLEX 15 M1_CLS 16 M1_LINK 17 M1_DUPLEX 18 VSS (CORE) 19 M0_TXEN 20 M0_TXD/(M0_TXD[0])1 21 M0_TXCLK/(M0_TXD[1]) 22 M0_CRS_DV 23 M0_RXD/(M0_RXD[0]) 24 M0_RXCLK/(M0_RXD[1]) 25 VDD 26 M1_TXEN 27 M1_TXD/(M1_TXD[0]) 28 M1_TXCLK/(M1_TXD[1]) 29 M1_CRS_DV 30 M1_RXD/(M1_RXD[0]) 31 M1_RXCLK/(M1_RXD[1]) 32 VSS 33 M2_TXEN 34 M2_TXD/(M2_TXD[0]) Data Sheet 35 M2_TXCLK/M2_TXD[1]) 70 M5_CRS_DV 36 M2_CRS_DV 71 M5_RXD/(M5_RXD[0]) 37 M2_RXD/(M2_RXD[0]) 72 38 M2_RXCLK/ (M2_RXD[1]) M5_RXCLK/ (M5_RXD[1]) 73 VDD (CORE) 39 VDD (CORE) 74 M6_TXEN 40 M3_TXEN 75 M6_TXD/(M6_TXD[0]) 41 M3_TXD/(M3_TXD[0]) 76 42 M3_TXCLK/(M3_TXD[1]) M6_TXCLK/ (M6_TXD[1]) 43 M3_CRS_DV 77 M6_CRS_DV 44 M3_RXD/(M3_RXD[0]) 78 M6_RXD/(M6_RXD[0]) 45 M3_RXCLK/(M3_RXD[1]) 79 M6_RXCLK/ (M6_RXD1]) 46 VSS (CORE) 80 VSS (CORE) 47 M2_CLS 81 M7_TXEN 48 M2_LINK 82 M7_TXD/(M7_TXD[0]) 49 M2_DUPLEX 83 M7_TXCLK/(M7_TXD[1]) 50 M3_CLS 84 M7_CRS_DV 51 M3_LINK 85 M7_RXD/(M7_RXD[0]) 52 M3_DUPLEX 86 M7_RXCLK/(M7_RXD[1]) 53 M4_CLS 87 VDD 54 M4_LINK 88 M6_CLS 55 M4_DUPLEX 89 M6_LINK 56 M5_CLS 90 M6_DUPLEX 57 M5_LINK 91 M7_CLS 58 M5_DUPLEX 92 M7_LINK 59 VDD 93 M7_DUPLEX 60 M4_TXEN 94 VSS 61 M4_TXD/(M4_TXD[0]) 95 M_CLK 62 M4_TXCLK/(M4_TXD[1]) 96 VDD (CORE) 63 M4_CRS_DV 97 M8_RXDV/S8_CRS_DV 64 M4_RXD/(M4_RXD[0]) 98 M8_COL/S8_COL 65 M4_RXCLK/(M4_RXD[1]) 99 VSS 66 VSS 100 M8_RXCLK/S8_RXCLK 67 M5_TXEN 101 VDD 68 M5_TXD/(M5_TXD[0]) 102 M8_RXD[0]/S8_RXD 69 M5_TXCLK/M5_TXD[1]) 103 M8_RXD[1] 4 Zarlink Semiconductor Inc. MVTX1100 Data Sheet 104 M8_RXD[2] 139 T_MODE 175 VDD 105 M8_RXD[3] 140 VSS (CORE) 176 L_D[11] 106 VSS (CORE) 141 RSTOUT# 177 L_D[12] 107 M8_TXCLK/S8_TXCLK 142 RSTIN# 178 L_D[13] 108 VDD 143 (MIRROR_CONTROL[0]) 179 L_D[14] 109 M8_TXEN[0]/S8_TXEN 144 (MIRROR_CONTROL[1]) 180 VSS 110 M8_TXD[0]/S8_TXD 145 (MIRROR_CONTROL[2]) 181 L_D[15] 111 M8_TXD[1] 146 (MIRROR_CONTROL[3]) 182 L_D[16] 112 M8_TXD[2] 147 VDD 183 L_D[17] 113 M8_TXD[3] 148 SCLK 184 VDD (CORE) 114 M8_LINK/S8_LINK 149 VSS 185 L_D[18] 115 M8_DUPLEX/S8_DUPLE X 150 L_A[2] 186 L_D[19] 151 L_A[17] 187 L_D[20] 116 M8_SPEED 152 VDD 188 L_D[21] 117 VSS 153 L_CLK 189 VSS 118 M8_REFCLK 154 VSS 190 L_D[22] 119 VDD 155 L_WE# 191 L_D[23] 120 M_MDC 156 L_OE# 192 L_D[24] 121 VSS 157 L_ADSC# 193 L_D[25] 122 M_MDIO 158 L_A[16] 194 VDD 123 SCL 159 VDD (CORE) 195 L_D[26] 124 SDA 160 L_A[15] 196 L_D[27] 125 TEST# 161 L_D[0] 197 L_D[28] 126 TRUNK_ENABLE 162 VSS 198 VSS (CORE) 127 STROBE 163 L_D[1] 199 L_D[29] 128 DATA0 164 L_D[2] 200 L_D[30] 129 ACK 165 L_D[3] 201 L_D[31] 130 VDD (CORE) 166 VDD 202 VDD 131 TSTOUT[0] 167 L_D[4] 203 L_A[18] 132 TSTOUT[1] 168 L_D[5] 204 L_A[3] 133 TSTOUT[2] 169 L_D[6] 205 L_A[4] 134 TSTOUT[3] 170 L_D[7] 206 L_A[5] 135 TSTOUT[4] 171 VSS (CORE) 207 VSS 136 TSTOUT[5] 172 L_D[8] 208 L_A[6] 137 TSTOUT[6] 173 L_D[9] Note 1: 138 TSTOUT[7] 174 L_D[10] 5 Zarlink Semiconductor Inc. Pin names inside ( ) indicate RMII pins for ports 0-7. MVTX1100 S S R A M MVTX1100 Switch Chip 1-Port MII 10/100 8-Port 10 MB Serial 10/100 MII Data Sheet PAL 10 MB Serial Interface Home PNA PHY 10/100 RMII MVTX2604 Routing Switch 1 G GMII 24 10/100 Ports + 2-1 G Uplinks . . . Home PNA PHY Line Card 192+2 Port Switch MDU System 10 Mbps Serial Interface S S R A M MVTX1100 8-Port 1 MB Serial MVTX1100 1 MB Serial Interface Home PNA PHY 10/100 MII Home PNA PHY Line Card 64+1 Port Switch MDU System Figure 2 - System Block Diagram (High Port Density MDU System) 6 Zarlink Semiconductor Inc. MVTX1100 1k Figure 3 - MVTX1100 Block Diagram 7 Zarlink Semiconductor Inc. Data Sheet MVTX1100 1.0 Data Sheet Functional Operation The MVTX1100 was designed to provide a cost-effective layer 2 switching solution, using technology from the Zarlink family to offer a highly integrated product for the unmanaged, DiffServ ready, Ethernet switching market. Nine 1/10 Media Access Controllers (MAC) provide the protocol interface into the MVTX1100. These MACs perform the required packet checks to ensure that each packet provided to the Frame Engine meets all the IEEE 802.1 standards. Data packets longer than 1518 (1522 with VLAN tag) bytes and shorter than 64 bytes are dropped and MVTX1100 has been designed to support minimum inter-frame gaps between incoming packets. The PHY addresses for the 8 RMII MACs are from 08h to 0Fh. These eight ports are denoted as ports 0 to 7. The PHY address for the uplink MAC is 10h. This port is denoted as port 8. The Frame Engine (FE) is the primary packet buffering and forwarding engine within the MVTX1100. As such, the FE controls the storage of packets in and out of the external frame buffer memory, keeps track of frame buffer availability and schedules output packet transmissions. While packet data is being buffered, the FE extracts the necessary information from each packet header and sends it to the Search Engine for processing. Search results returned to the FE ensue the scheduling of packet transmission and prioritization. When a packet is chosen for transmission, the FE reads the packet from external buffer memory and places it in the output FIFO of the output port. 2.0 Address Learning and Aging The MVTX1100 is able to begin address learning and packet forwarding shortly after powerup has been completed. The Search Engine examines the contents of its internal Switch Database Memory for each valid packet received on an input port. Unknown source and destination MAC addresses are detected when the Search Engine does not find a match within its database. These unknown source MAC addresses are learned by creating a new entry in the switch database memory, and storing the necessary resulting information in that location. Subsequent searches to a learned destination MAC address will return the new contents of that MAC Control Table (MCT) entry. After each source address search the MCT entry aging flag is updated. MCT entries that have not been accessed during a user configurable time period (2 to 67,108 seconds) will be removed. This aging time period can be configured using the 16-bit value stored in the registers MAC Address Aging Time Low and High (MATL[7:0], MATH[7:0]). The aging period is defined by the following equation: {MATH[7:0]&MATL[7:0]} x 1024ms = Tage The aging of all MCT entries is checked once during each time period. If the MCT entry has not been utilized before the end of the next time period, it will be deleted. Note that when the system clock operates at 20 MHz, the aging period will be increased, compared with 50 MHz of system clock. One should adjust the MATH and MATHL content variable accordingly. 3.0 Quality of Service The MVTX1100 utilizes Zarlink’s architecture that provides a new level of (QoS) capability to unmanaged switch applications. Similar in operation to the QoS capabilities of other Zarlink chipset members, MVTX1100 provides two transmit queues per output port. The Frame Engine manages the output transmission queues for all the MVTX1100 ports. Once the destination address search is complete, and the switch decision is passed back to the FE, the packet is inserted into the appropriate output queue. The packet entry into the high or low priority queue is controlled by either the VLAN tag information or the Type of Service/Differentiated Service (TOS/DS) field in the IP header. Either of these priority fields can be used to select the transmission priority, and the mapping of the priority field values into either the high or low priority queue can be configured using the MVTX1100 configuration registers. 8 Zarlink Semiconductor Inc. MVTX1100 Data Sheet If the system uses the TOS/DS field to prioritize packets, there are two choices regarding which bits of the TOS/DS field are used. Bits [0:2] of the TOS byte (known as the IP precedence field) or bits [3:5] of the TOS byte (known as the DRT field) can be used to map the transmission queue priority. Either bits, [0:2] or [3:5], can also be used as a packet drop precedence, by using bits 6 and 7 of the FCB Buffer Low Threshold register (FCBST). MVTX1100 utilizes Weighted Round Robin (WRR) and Weighted Random Early Detection/Drop (WRED) to schedule packets for transmission. To enable MVTX1100’s QoS capabilities requires the use of an external EEPROM to change the default register configurations and turn on QoS. Weighted Round Robin is an efficient method to ensure that each of the transmission queues gets at least a minimum service level. With two output transmission queues, MVTX1100 will transmit “X” packets from the high priority queue before transmitting “Y” packets from the low priority queue. MVTX1100 allows the designer to set the high priority weight to a value between 0 and 16. The low priority weight is fixed at the value 1. If the high priority weight is set to the value 4, then it will transmit 4 high priority packets before transmitting each low priority packet. MVTX1100 also uses a proprietary mechanism to ensure the timely delivery of high priority packets. When the latency of high priority packets reaches a threshold, it will override the WRR weights and transmit only high priority packets until the high priority packet delays are below the threshold. This threshold limit is set at less than 1 ms (last bit in and first bit out). The QoS capabilities of the MVTX1100 are enabled by loading the appropriate values into the configuration registers. QoS for packet transmission is enabled by performing the following four steps: 1. Select the TOS/DS or VLAN Priority Tag field as the control for IP packet transmission. The selection is made using bit 7 of the Flooding Control (FCR[7]) register. - FCR[7]=0, use VLAN Priority Tag field to map the transmission priority if this Tag field exists. - FCR[7]=1, use TOS/DS field for IP packet transmission priority mapping. 2. Select which TOS/DS field to use as the control for packet transmission priority if the TOS/DS field was selected in step 1. The selection is made using bit 6 of the FCB Buffer Low Threshold (FCBST[6]) register. - FCBST[6]=0, use DTR subfield to map the transmission priority. - FCBST[6]=1, use IP precedence subfield1 to map the transmission priority. 3. Set the transmission queue weight for the high priority queue in the Transmission Scheduling Control (AXSC[3:0]) register. 4. Set the priority mappings from the TOS/DS or VLAN Priority Tag field to the high or low priority output queue. The selection is made using the VLAN Priority Map (AVPM) and TOS Priority Map (TOSPML) registers. Note that, for half duplex operation, the priority queues2 must be enabled using bit 7 in the Transmission Scheduling Control (AXSC[7]) register to utilize the QoS function. When QoS is enabled, MVTX1100 will utilize WRR to schedule packet transmission, and will use Weighted Random Early Detection/Drop (WRED) to drop random packets in order to handle buffer memory congestion. In this method, only certain packet flows are slowed down while the remaining see no impact from the network traffic congestion. Weighted Random Early Detection/Drop (WRED) is a method of handling traffic congestion in the absence of flow control mechanisms. When flow control is enabled, all devices that are connected to a switch node that is exercising flow control are effectively unable to transmit, including nodes that are not directly responsible for the congestion problem. This inability to transmit during flow control periods would play havoc with voice packets, or other high priority packet flows, and therefore flow control is not recommended for networks that mix voice and data traffic. 1. IP precedence and DTR subfields are referred to as TOS/DS[0:2] and TOS/DS[3:5] in the IP TOS/DS byte. 2. In Half Duplex mode, the QoS functions are disabled by default. 9 Zarlink Semiconductor Inc. MVTX1100 Data Sheet WRED allows traffic to continue flowing into ports on a switch, and randomly drops packets with different probabilities based upon each packet’s priority markings. As the switch congestion increases, the probability of dropping an input packet increases, and as congestion decreases, the probability of dropping an input packet decreases. In this manner, only traffic flows that have had packets dropped will be affected by the congestion. Other traffic flows will see no effect. The following table summarizes the WRED operation of the MVTX1100. It lists the buffer thresholds at which each drop probability takes effect. WRED Threshold Condition for High Priority Queue Level 0 Level 1 Drop Percentage Condition for Low Priority Queue Drop Percentage for High-Drop Packet Drop Percentage for Low-Drop Packet 50% 0% 72 buffers occupied 75% 25% 84 buffers occupied 100% 50% Total buffer space available in device is ≤LPBT 24 buffers occupied Level 2 Table 1 - WRED Operation of the MVTX1100 The WRED packet drop capabilities of MVTX1100 are enabled by performing the following three steps: 1. Select the TOS/DS or VLAN Tag field as the control for packet dropping. The selection is made using bit 7 of the Flooding Control (FCR[7]) register. - FCR[7]=0, use VLAN Priority Tag field to map the drop priority if this Tag field exists - FCR[7]=1, use ToS/DS field for IP packet transmission priority mappin. 2. Select which TOS/DS Tag field to use for packet dropping provided that the TOS/DS field was selected in step 1. The selection is made using bit 7 of the FCB Buffer Low Threshold (FCBST[7]) register. - FCBST[7]=0, use DTR subfield to map the drop priority - FCBST[7]=1, use IP precedence subfield to map the drop priority 3. Set the drop mappings from the TOS/DS or VLAN Tag field to the high or low drop priority output flag. The selection is made using the VLAN Drop Map (AVDM) and TOS Discard Map (TOSDML) registers. Note that to utilize the QoS function of the MVTX1100, flow control has to be disabled. 4.0 Buffer Management MVTX1100 stores each input packet into the external frame buffer memory while determining the destination the packet is to be forwarded to. The total number of packets that can be stored in the frame buffer memory depends upon the size of the external SBRAM that is utilized. For a 256 k byte SBRAM MVTX1100 can buffer 170 packets. For a 512 K byte SBRAM MVTX1100 can buffer 340 packets. In order to provide good QoS characteristics, MVTX1100 must allocate the available buffer space to low and high priority unicast and multicast traffic. This can be accomplished using the external EEPROM to load the appropriate values into MVTX1100 configuration registers. To allow the designer to set the minimum number of buffers provided for low drop priority unicast traffic, use the Low Drop Priority Buffer Threshold (LPBT[7:0]) register. To set the maximum number of buffers allocated for all multicast packets, use the Multicast Buffer Control (MBCR[7:0]) register. During operation MVTX1100 will continuously monitor the amount of frame buffer memory that is available, and when the unused buffer space falls below a designer configurable threshold, MVTX1100 will begin to drop incoming packets (WRED). This threshold is set using the FCB Buffer Low Threshold (FCBST[5:0]) register. 10 Zarlink Semiconductor Inc. MVTX1100 5.0 Data Sheet Virtual LANs MVTX1100 provides the designer the ability to define a single port-based Virtual LAN (VLAN) for each of the nine ports. This VLAN is individually defined for each port using the Port Control Registers (ECR1Px[6:4]). Bits [6:4] allow the designer to define a VLAN ID (value between 0-7) for each port. When packets arrive at an input of MVTX1100, the search engine will determine the VLAN ID for that port, and then determine which of the other ports also are members of that VLAN by matching their assigned VLAN Id values. The packet will then be transmitted to each port with the same VLAN ID as the source port. 6.0 Concentration Mode MVTX1100 supports a Concentration Mode, where each of the 0-7 port is only allowed to directly communicate with the uplink port 8. This mode ensures that data from any of ports 0-7 cannot be directly seen by any other port. This feature is used in MDU applications to provide data privacy to subscribers. To use this mode, a CONC (concentration) bit in each ECR1 register of ports 0-8 must be enabled, i.e., ECR1 [7]=1, and ports 0-7 must each be set on a separate VLAN. Note that, in concentration mode, the VLAN of port 8 will be ignored. A more flexible concentration mode can be set up. For this mode, ports 0–7 are partitioned into several groups, sharing the same VLAN ID. This will allow traffic within the same group to freely communicate with each other, while continuing to communicate outside the group in concentration mode. 7.0 Port Trunking Port trunking allows the designer to configure the MVTX1100, such that ports 0 and 1 are defined as a logical port. This provides a 20Mb/s link to a switch or server using two 10Mb/s ports in parallel. Ports 0 and 1 can be trunked by pulling the TRUNK_EN pin to the high state. In this mode, the source MAC address of all packets received from the trunk are checked against the MCT database to ensure that they have a port ID of 0 or 1. Packets that have a port ID other than 0 and 1 will effect the MVTX1100 to learn the new MAC address for this port change. On transmission, the selected trunk port is determined by hashing the source and destination MAC addresses. This provides a one-to-one mapping between the trunk port and the MAC addresses. Subsequent packets with the same MAC addresses will always utilize the same trunk port. MVTX1100 also provides a safe fail-over mode for port trunking. If one of the two ports goes down, via the ports link signal, MVTX1100 will switch all traffic destined to the failed port over to the remaining port in the trunk. Thus maintaining the trunk link, albeit at a lower effective bandwidth. 11 Zarlink Semiconductor Inc. MVTX1100 8.0 Data Sheet Port Mirroring The port mirroring function is only supported in RMII mode. Using the 4 port mirroring control pins provides the ability to enable or disable port mirroring, select which of the remaining 7 ports is to be mirrored and whether the received or transmitted data is being mirrored. The control for this function is shown in the following table. Mirrored Port Mirror_Control [3] Mirror_Control [2] Mirror_Control [1] Mirror_Control [0] Port 0 RX 1 0 0 0 Port 0 TX 0 0 0 0 Port 1 RX 1 0 0 1 Port 1 TX 0 0 0 1 Port 2 RX 1 0 1 0 Port 2 TX 0 0 1 0 Port 3 RX 1 0 1 1 Port 3 TX 0 0 1 1 Port 4 RX 1 1 0 0 Port 4 TX 0 1 0 0 Port 5 RX 1 1 0 1 Port 5 TX 0 1 0 1 Port 6 RX 1 1 1 0 Port 6 TX 0 1 1 0 Disabled X 1 1 Table 2 - Port Mirroring Configuration 1 When enabled, port mirroring will allow the user to monitor traffic going through the switch on output Port 7. If the port mirroring control pins, Mirror_Control[3:0], are left floating, MVTX1100 will operate with the port mirroring function disabled. When port mirroring is enabled, the user must configure Port 7 to operate in the same mode as the port it is mirroring (autoneg, duplex, speed, flow control). 9.0 Power Saving Mode in MAC The power saving mode is activated only in RMII mode. MVTX1100 was designed to be power efficient. When the internal RMII MAC sections detect that the external port is not receiving or transmitting packets, it will shut down and conserve power. When new packet data is loaded into the output transmit FIFO of a MAC in power saving mode, the MAC will return to life and begin operating immediately. When the MAC is in power saving mode and new packet data is received on the RMII interface, the MAC will return to life and receive data normally into the receive FIFO. This wake up occurs when the MAC sees the CRS_DV signal asserted. Using this method, the switch will turn off all MAC sections during periods when there is no network activity (at night for example), and save power. For large networks this power savings can be significant. To achieve the maximum power efficiency, the designer should use a physical layer transceiver that utilizes “Wake-On-LAN” technology. 12 Zarlink Semiconductor Inc. MVTX1100 10.0 Data Sheet EEPROM I2C Interface A simple 2 wire serial interface is provided to allow the configuration of the MVTX1100 via an external EEPROM. MVTX1100 utilizes a 1 K bit EEPROM with an I2C interface. 11.0 Management Interface MVTX1100 uses a standard parallel port interface to provide external CPU access to the internal registers. This parallel interface consists of 3 pins: DATA0, STROBE and ACK. The DATA0 pin provides the address and data content input to MVTX1100, while the ACK pin provides the corresponding output to the external CPU. The STROBE pin is provided as the clock for both serial data streams. Any of its internal registers can be modified through this parallel port interface. Figure 4 - Write Command Figure 5 - Read Command Each management interface transfer consists of four parts: 1. A START pulse – occurs when DATA is sampled high when STROBE is rising followed by DATA being sampled low when STROBE falls. 2. Register Address strobed into DATA0 pin by the high level of the STROBE pin. 3. Either a Read or Write Command (see waveforms above). 4. Data to be written provided on DATA0, or data to be read back provided on ACK. Any command can be aborted in the middle by sending an ABORT pulse to MVTX1100. An ABORT pulse occurs when DATA is sampled low and STROBE is rising, then DATA is sampled high when STROBE falls. 13 Zarlink Semiconductor Inc. MVTX1100 12.0 Data Sheet Configuration Register Definitions MVTX1100 registers can be accessed via the parallel interface and/or the I 2C interface. Some registers are only accessible through the parallel interface. The access method for each register is listed in the individual register definitions. Each register is 8-bit wide. 12.1 GCR - Global Control Register • Access: parallel interface, Write Only • Address: h30 12.2 Bit 0 Save configuration into EEPROM Write '1' followed by a '0' (Default = 0) Bit 1 Save configuration into EEPROM and reset system Write '1' (self-clearing due to reset) (Default = 0) Bit 2 Start Built-In Self-Test (BIST) Write '1' followed by a '0' (Default = 0) Bit 3 Reset system Write '1' (self-clearing due to reset) (Default = 0) Bit [7:4] Reserved DCR - Device Status and Signature Register • Access: parallel interface, Read Only • Address: h31 Bit 0 Busy writing configuration from I2C 1: Activity 0: No Activity Bit 1 Busy reading configuration from I2C 1: Activity 0: No Activity Bit 2 Built-In Self-Test (BIST) in progress 1: BIST In-Progress 0: Normal Mode Bit 3 RAM error during BIST 1: RAM Error 0: No Error Bit [5:4] Reserved Bit [7:6] Revision number 00: Initial Silicon 01: Second Silicon 14 Zarlink Semiconductor Inc. MVTX1100 12.3 Data Sheet DA – DA Register • Access: parallel interface, Read Only • Address: h36 Always returns 8-bit value hDA. Indicates the (Default DA) parallel port connection is good. 12.4 MBCR – Multicast Buffer Control Register (Address H00) • Access: parallel interface and I2C, Read/Write • Address: h00 Bit [7:0] 12.5 MAX_CNT_LMT Maximum number of multicast frames allowed (Default = 80) FCBST – FCB Buffer Low Threshold • Access: parallel interface and I2C, Read/Write • Address: h01 Bits [5:0] BUF_LOW_TH Buffer Low Threshold – number of FCB left before triggering WRED (Default = 3F) Bit 6 Use IP precedence field (TOS[0:2]) for Priority (Default = 0) Bit 7 Use IP precedence subfield (TOS[0:2]) for Drop (Default = 0) Note that, for Bits 6 and 7, Default = 0 means to use DTR filed (TOS[3:5]). 12.6 LPBT – Low Drop Priority Buffer Threshold • Access: parallel interface and I2C, Read/Write • Address: h02 Bit [7:0] 12.7 LOW_PRI_CNT Number of frame buffers reserved for low-dropping traffic (Default 3F) FCR – Flooding Control Register • Access: parallel interface and I2C, Read/Write • Address: h03 Bits [3:0] U2MR Unicast to Multicast Rate (Default = 8) Bits [6:4] TimeBase 000 = 100 µs 001 = 200 µs 010 = 400 µs 011 = 800 µs 100 = 1.6 ms 101 = 3.2 ms 110 = 6.4 ms 111 = 100 µs (Default = 000) Bit 7 USE_TOS Pick TOS over VLAN priority for IP Packet. (Default = 0) 15 Zarlink Semiconductor Inc. MVTX1100 12.8 AVTCL – VLAN Type Code Register Loq • Access: parallel interface and I2C, Read/Write • Address: h04 Bit [7:0] 12.9 VLANType_LOW Lower 8 bits of VLAN type code. (Default 00) AVTCH – VLAN Type Code Register High • Access: parallel interface and I2C, Read/Write • Address: h05 Bit [7:0] 12.10 Data Sheet VLANType_HIGH Upper 8 bits of the VLAN type code (Default 81) AVPM – VLAN Priority Map • Access: parallel interface and I2C, Read/Write • Address: h06 Map VLAN tag into 2 transmit queues (0 = low priority, 1 = high priority) 12.11 Bit 0 Mapped priority of tag value 0 (Default 0) Bit 1 Mapped priority of tag value 1 (Default 0) Bit 2 Mapped priority of tag value 2 (Default 0) Bit 3 Mapped priority of tag value 3 (Default 0) Bit 4 Mapped priority of tag value 4 (Default 0) Bit 5 Mapped priority of tag value 5 (Default 0) Bit 6 Mapped priority of tag value 6 (Default 0) Bit 7 Mapped priority of tag value 7 (Default 0) AVDM – VLAN Discard Map • Access: parallel interface and I2C, Read/Write • Address: h07 Map VLAN tag into frame discard when low priority buffer usage is above threshold Bit 0 Frame discard for tag value 0 (Default 0) Bit 1 Frame discard for tag value 1 (Default 0) Bit 2 Frame discard for tag value 2 (Default 0) Bit 3 Frame discard for tag value 3 (Default 0) Bit 4 Frame discard for tag value 4 (Default 0) Bit 5 Frame discard for tag value 5 (Default 0) Bit 6 Frame discard for tag value 6 (Default 0) Bit 7 Frame discard for tag value 7 (Default 0) 16 Zarlink Semiconductor Inc. MVTX1100 12.12 Data Sheet TOSPML – TOS/DS Priority Map Low • Access: parallel interface and I2 C, Read/Write • Address: h08 Map TOS field in IP packet into 2 transmit queues (0 = low priority, 1 = high priority). Bit 0 Mapped priority when TOS is 0 (Default 0) 1 Bit 1 Mapped priority when TOS is 1 (Default 0) Bit 2 Mapped priority when TOS is 2 (Default 0) Bit 3 Mapped priority when TOS is 3 (Default 0) Bit 4 Mapped priority when TOS is 4 (Default 0) Bit 5 Mapped priority when TOS is 5 (Default 0) Bit 6 Mapped priority when TOS is 6 (Default 0) Bit 7 Mapped priority when TOS is 7 (Default 0) 1. TOS = 1 means the appropriate 3-bit TOS subfield is “001. 12.13 TOSDML – TOS/DS Discard Map • Access: parallel interface and I2C, Read/Write • Address: h0A Map TOS into frame discard when low priority buffer usage is above threshold 12.14 Bit 0 Frame discard when TOS is 0 (Default 0) Bit 1 Frame discard when TOS is 1 (Default 0) Bit 2 Frame discard when TOS is 2 (Default 0) Bit 3 Frame discard when TOS is 3 (Default 0) Bit 4 Frame discard when TOS is 4 (Default 0) Bit 5 Frame discard when TOS is 5 (Default 0) Bit 6 Frame discard when TOS is 6 (Default 0) Bit 7 Frame discard when TOS is 7 (Default 0) AXSC – Transmission Scheduling Control Register • Access: parallel interface and I2C, Read/Write • Address: h0B Bits [3:0]: Transmission Queue Service Weight for high priority queue Bit [4] Reserved Bit [5] Reserved Bit [6]: Global Flow Control (Default 0, enable) Bit [7]: Half Duplex Priority Enable (Default 0) 17 Zarlink Semiconductor Inc. (Default F) MVTX1100 12.15 Data Sheet MII_OP0 – MII Register Option 0 • Access by parallel interface and I2C, Read/Write • Address: h0C To provide a non-standard address for the Phy Status Register. When low and high Address bytes are 0, MVTX1100 will use the standard address. Bit [7:0] Low order address byte (Default 00) 12.16 MII_OP1 – MII Register Option 1 • Access: parallel interface and I2C, Read/Write • Address: h0D Bit [7:0] 12.17 High order address byte (Default 00) AGETIME_LOW – Mac Address Aging Timer Low Access: parallel interface and I2C, Read/Write Address: h0E Bit [7:0] 12.18 Low byte of the MAC address aging timer. (Default 25) AGETIME_HIGH – Mac Address Aging Timer High • Access: parallel interface and I2C, Read/Write • Address: h0F Bit [7:0] High byte of the MAC address aging timer. (Default 01) The aging time is based on the following formula: {AGETIME_HIGH, AGETIME_LOW} x 1024 ms. 12.19 ECR1P0 – Port 0 Control Register • Access: parallel interface and I2C, Read/Write • Address: h10 Bits [3:0] RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Auto and advertise based on Bits [2:0] Bits [6:4] PVID Port-based VLAN ID Bit [7] CONC: Enable Concentration Mode 18 Zarlink Semiconductor Inc. (Default 0000) (Default 000) MVTX1100 12.20 ECR1P1 – Port 1 Control Register • Access: parallel interface and I2C, Read/Write • Address: h11 Bits [3:0] 12.21 Data Sheet RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Auto and advertise based on Bits [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) ECR1P2 – Port 2 Control Register • Access: parallel interface and I2C, Read/Write • Address: h12 Bits [3:0] RMII Port Mode Only for RMII mode,(Default 0000) Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Auto and advertise based on Bits [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) 19 Zarlink Semiconductor Inc. MVTX1100 12.22 ECR1P3 – Port 3 Control Register • Access: parallel interface and I2C, Read/Write • Address: h13 Bits [3:0] 12.23 Data Sheet RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Auto and advertise based on Bits [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) ECR1P4 – Port 4 Control Register • Access: parallel interface and I2C, Read/Write • Address: h14 Bits [3:0] RMII Port Mode Only for RMII mode, (Default 0000) Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bit [2:0] 0 – Auto and advertise based on Bit [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] Reserved Enable Concentration Mode (Default 0) 20 Zarlink Semiconductor Inc. MVTX1100 12.24 ECR1P5 – Port 5 Control Register • Access: parallel interface and I2C, Read/Write • Address: h15 Bits [3:0] 12.25 Data Sheet RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bit [2:0] 0 – Auto and advertise based on Bits [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) ECR1P6 – Port 6 Control Register • Access: parallel interface and I2C, Read/Write • Address: h16 Bits [3:0] RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bit [2:0] 0 – Auto and advertise based on Bit [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) 21 Zarlink Semiconductor Inc. MVTX1100 12.26 ECR1P7 – Port 7 Control Register • Access: parallel interface and I2C, Read/Write • Address: h17 Bits [3:0] 12.27 Data Sheet RMII Port Mode Only for RMII mode, Serial Mode DON’T CARE Bit [0] 1 – Flow Control Off 0 – Flow Control On Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [3] 1 – Force configuration based on Bit [2:0] 0 – Auto and advertise based on Bit [2:0] (Default 0000) Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) ECR1P8 – Port 8 Control Register • Access: parallel interface and I2C, Read/Write • Address: h18 Bits [3:0] Port Mode (Default 0000) Bit [3] 1 – Force configuration based on Bit [2:0] 0 – Autonegotiate and advertise based on Bit[2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Port-based VLAN ID (Default 000) Bit [7] CONC: Enable Concentration Mode (Default 0) 22 Zarlink Semiconductor Inc. MVTX1100 12.28 Data Sheet FC_0 – Flow Control Byte 0 • Access: parallel interface and I2C, Read/Write • Address: h19 The flow control hold time parameter is the length of time a flow control message is effectual (i.e. halts incoming traffic) after being received. The hold time is measured in units of “slots,” the time it takes to transmit 64 bytes at wire speed. The default setting is 32 slots, or for a 100 Mbps port, approximately 164 s. Bits [7:0] 12.29 Flow control hold time byte 0 FC_1 – Flow Control Byte 1 • Access: parallel interface and I2C, Read/Write • Address: h1A Bits [7:0] 12.30 Flow control hold time byte 1 Access: parallel interface and I2C, Read/Write • Address: h1B Bits [7:0] Flow control frame CRC byte 0 (Default 96) FC_3 – Flow Control CRC Byte 1 • Access: parallel interface and I2C, Read/Write • Address: h1C Bits [7:0] 12.32 Flow control frame CRC byte 1 (Default 8E) FC_4 – Flow Control CRC Byte 2 • Access: parallel interface and I2C, Read/Write • Address: h1D Bits [7:0] 12.33 Flow control frame CRC byte 2 (Default 99) FC_5 – Flow Control CRC Byte 3 • Access: parallel interface and I2C, Read/Write • Address: h1E Bits [7:0] 12.34 (Default 00) FC_2 – Flow Control CRC Byte 0 • 12.31 (Default FF) Flow control frame CRC byte 3 (Default 9A) CHECKSUM - EEPROM Checksum • • Access: parallel interface and I2C, Read/Write • • Address: h24 The calculation is [0x100 - ((sum of registers 0x00~0x23) & 0xFF)]. For example, based on the default register settings, the CHECKSUM value would be 0xEE. Bits [7:0] Checksum (Default 00) 23 Zarlink Semiconductor Inc. MVTX1100 13.0 Data Sheet MVTX1100 Pin Descriptions Note: # Active low signal I Input signal S Input signal with Schmitt-Trigger O Output signal OD Open-Drain driver I/O Input & Output signal SL Slew Rate Controlled D Pulldown U Pullup 5 5V Tolerance Pin No(s). Symbol Type Name & Functions Frame Buffer Memory Interface 201, 200, 199, 197, 196, 195, 193, 192, 191, 190, 188, 187, 186, 185, 183, 182, 181, 179, 178, 177, 176, 174, 173, 172, 170, 169, 168, 167, 165, 164, 163, 161 L_D[31:0] I/O, U, SL Databus to Frame Buffer Memory 203, 151, 158, 160, 10, 9, 8, 6, 5, 4, 2, 1, 208, 206, 205, 204, 150 L_A[18:2] I/O, U, SL Address Pins for Buffer Memory 153 L_CLK O Frame Buffer Memory Clock 155 L_WE# O, SL Frame Buffer Memory Write Enable 156 L_OE# O Frame Buffer Memory Output Enable 157 L_ADSC# O, SL Address Status Control 120 M_MDC O MII Management Data Clock 122 M_MDIO I/O, U MII Management Data I/O MII Management Interface I2C Interface (Serial EEPROM Interface) 123 SCL O, U, 5 I2C Data Clock 124 SDA I/O, U, OD, 5 I2C Data I/O Parallel Port Management Interface 127 STROBE I, U, S, 5 Strobe Pin 128 DATA0 I, U, 5 Data Pin 129 ACK O, U, OD, 5 Acknowledge Pin M0_RXD I, U Port 0 Receive Data Port 0 Serial Interface 23 24 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions 24 M0_RXCLK I, U Port 0 Receive Clock 22 M0_CRS_DV I, D Port 0 Carrier Sense and Data Valid 20 M0_TXD O Port 0 Transmit Data 21 M0_TXCLK I Port 0 Transmit Clock 19 M0_TXEN O Port 0 Transmit Enable 12 M0_CLS I, U Port 0 Collision Detection 13 M0_LINK I, U Port 0 Link Status 14 M0_DUPLEX I, U Port 0 Full Duplex Select (half-duplex = 0) 30 M1_RXD I, U Port 1 Receive Data 31 M1_RXCLK I, U Port 1 Receive Clock 29 M1_CRS_DV I, D Port 1 Carrier Sense and Data Valid 27 M1_TXD O Port 1 Transmit Data 28 M1_TXCLK I Port 1 Transmit Clock 26 M1_TXEN O Port 1 Transmit Enable 15 M1_CLS I, U Port 1 Collision Detection 16 M1_LINK I, U Port 1 Link Status 17 M1_DUPLEX I, U Port 1 Full-Duplex Select (half-duplex = 0) 37 M2_RXD I, U Port 2 Receive Data 38 M2_RXCLK I, U Port 2 Receive Clock 36 M2_CRS_DV I, D Port 2 Carrier Sense and Data Valid 34 M2_TXD O Port 2 Transmit Data 35 M2_TXCLK I Port 2 Transmit Clock 33 M2_TXEN O Port 2 Transmit Enable 47 M2_CLS I, U Port 2 Collision Detection 48 M2_LINK I, U Port 2 Link Status 49 M2_DUPLEX I, U‘ Port 2 Full-Duplex Select (half-duplex = 0) M3_RXD I, U Port 3 Receive Data Port 1 Serial Interface Port 2 Serial Interface Port 3 Serial Interface 44 25 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions 45 M3_RXCLK I, U Port 3 Receive Clock 43 M3_CRS_DV I, D Port 3 Carrier Sense and Data Valid 41 M3_TXD O Port 3 Transmit Data 42 M3_TXCLK I Port 3 Transmit Clock 40 M3_TXEN O Port 3 Transmit Enable 50 M3_CLS I, U Port 3 Collision Detection 51 M3_LINK I, U Port 3 Link Status 52 M3_DUPLEX I, u Port 3 Full-Duplex Select (half-duplex = 0) 64 M4_RXD I, U Port 4 Receive Data 65 M4_RXCLK I, U Port 4 Receive Clock 63 M4_CRS_DV I, U Port 4 Carrier Sense and Data Valid 61 M4_TXD O Port 4 Transmit Data 62 M4_TXCLK I Port 4 Transmit Clock 60 M4_TXEN O Port 4 Transmit Enable 53 M4_CLS I, U Port 4 Collision Detection 54 M4_LINK I, U Port 4 Link Status 55 M4_DUPLEX I, U Port 4 Full-Duplex Select (half-duplex = 0) 71 M5_RXD I, U Port 5 Receive Data 72 M5_RXCLK I, U Port 5 Receive Clock 70 M5_CRS_DV I, D Port 5 Carrier Sense and Data Valid 68 M5_TXD O Port 5 Transmit Data 69 M5_TXCLK I Port 5 Transmit Clock 67 M5_TXEN O Port 5 Transmit Enable 56 M5_CLS I, U Port 5 Collision Detection 57 M5_LINK I, U Port 5 Link Status 58 M5_DUPLEX I, U Port 5 Full-Duplex Select (half-duplex = 0) M6_RXD I, U Port 6 Receive Data Port 4 Serial Interface Port 5 Serial Interface Port 6 Serial Interface 78 26 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions 79 M6_RXCLK I, U Port 6 Receive Clock 77 M6_CRS_DV I, D Port 6 Carrier Sense and Data Valid 75 M6_TXD O Port 6 Transmit Data 76 M6_TXCLK I Port 6 Transmit Clock 74 M6_TXEN O Port 6 Transmit Enable 88 M6_CLS I, U Port 6 Collision Detection 89 M6_LINK I, U Port 6 Link Status 90 M6_DUPLEX I, U Port 6 Full-Duplex Select (half-duplex = 0) 85 M7_RXD I, U Port 7 Receive Data 86 M7_RXCLK I, U Port 7 Receive Clock 84 M7_CRS_DV I, D Port 7 Carrier Sense and Data Valid 82 M7_TXD O Port 7 Transmit Data 83 M7_TXCLK I Port 7 Transmit Clock 81 M7_TXEN O Port 7 Transmit Enable 91 M7_CLS U Port 7 Collision Detection 92 M7_LINK I, U Port 7 Link Status 93 M7_DUPLEX I, U Port 7 Full-Duplex Select (half-duplex = 0) 24, 23 M0_RXD[1:0] I, U Port 0 Receive Data 22 M0_CRS_DV I, D Port 0 Carrier Sense and Data Valid 21, 20 M0_TXD[1:0] O Port 0 Transmit Data 19 M0_TXEN O Port 0 Transmit Enable 31, 30 M1_RXD[1:0] I, U Port 1 Receive Data 29 M1_CRS_DV I, D Port 1 Carrier Sense and Data Valid 28, 27 M1_TXD[1:0] O Port 1 Transmit Data 26 M1_TXEN O Port 1 Transmit Enable M2_RXD[1:0] I, U Port 2 Receive Data Port 7 Serial Interface Port 0 RMII Interface Port 1 RMII Interface Port 2 RMII Interface 38, 27 27 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions 36 M2_CRS_DV I, D Port 2 Carrier Sense and Data Valid 35, 34 M2_TXD[1:0] O Port 2 Transmit Data 34 M2_TXEN O Port 2 Transmit Enable 45, 44 M3_RXD[1:0] I, U Port 3 Receive Data 43 M3_CRS_DV I, D Port 3 Carrier Sense and Data Valid 42, 41 M3_TXD[1:0] O Port 3 Transmit Data 40 M3_TXEN O Port 3 Transmit Enable 65, 64 M4_RXD[1:0] I, U Port 4 Receive Data 63 M4_CRS_DV I, D Port 4 Carrier Sense and Data Valid 62, 61 M4_TXD[1:0] O Port 4 Transmit Data 60 M4_TXEN O Port 4 Transmit Enable 72, 71 M5_RXD[1:0] I, U Port 5 Receive Data 70 M5_CRS_DV I, D Port 5 Carrier Sense and Data Valid 69, 68 M5_TXD[1:0] O Port 5 Transmit Data 67 M5_TXEN O Port 5 Transmit Enable 79, 78 M6_RXD[1:0] I, U Port 6 Receive Data 77 M6_CRS_DV I, D Port 6 Carrier Sense and Data Valid 76, 75 M6_TXD[1:0] O Port 6 Transmit Data 74 M6_TXEN O Port 6 Transmit Enable 86, 85 M7_RXD[1:0] I, U Port7 Receive Data 84 M7_CRS_DV I, D Port 7 Carrier Sense and Data Valid 83, 82 M7_TXD[1:0] O Port 7 Transmit Data 81 M7_TXEN O Port 7 Transmit Enable M8_RXD[3:0] I, U Port 8 Receive Data Port 3 RMII Interface Port 4 RMII Interface Port 5 RMII Interface Port 6 RMII Interface Port 7 RMII Interface Port 8 MII Interface 105, 104, 103, 102 28 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions 113, 112, 111, 110 M8_TXD[3:0] O Port 8 Transmit Data 109 M8_TXEN O Port 8 Transmit Enable 97 M8_RXDV I, D Port 8 Receive Data Valid 100 M8_RXCLK I, U Port 8 Receive Clock 107 M8_TXCLK I/O, U Port 8 Transmit Clock 114 M8_LINK I, U Port 8 Link Status 116 M8_SPEED I/O, U Port 8 Speed Select (100Mb = 1) 115 M8_DUPLEX I, U Port 8 Full-Duplex Select (half-duplex = 0) 98 M8_COL I, U Port 8 Collision Detect 118 M8_REFCLK O, U Port 8 Reference Clock M8_REFCLK=1/2 M_CLK 102 S8_RXD I, U Port 8 Serial Receive Data 100 S8_RXCLK I, U Port 8 Serial Receive Clock 97 S8_CRS_DV I, D Port 8 Serial Carrier Sense and Data Valid 110 S8_TXD O Port 8 Serial Transmit Data 107 S8_TXCLK I Port 8 Serial Transmit Clock 109 S8_TXEN O Port 8 Serial Transmit Enable 98 S8_COL I, U Port 8 Serial Collision Detect 114 S8_LINK I, U Port 8 Link Status 115 S8_DUPLEX I, U Port 8 Full-Duplex Select (half-duplex = 0) 95 M_CLK I Reference Clock for Serial interface = 50 MHz±50 ppm 148 SCLK I System Clock (50 - 80 MHz) 126 TRUNK_EN I, D Port Trunking Enable 142 RESIN# I, S Reset Pin 141 RESETOUT# O PHY Reset Pin 146, 145, 144, 143 MIR_CTL[3:0] I/O, U Port Mirroring Control (only for RMII mode) Port 8 Serial Interface Miscellaneous Control Pins 29 Zarlink Semiconductor Inc. MVTX1100 Pin No(s). Symbol Data Sheet Type Name & Functions Test Pins 125 TEST# Manufacturing Pin. Leave as No Connect (NC) 139 TMODE# I/O, U Manufacturing Pin. Puts device into test mode for ATE test. Leave as No Connect (NC) 138, 137, 136, 135 TSTOUT[7:4] O Test Outputs 134, 133, 132, 131 TSTOUT[3:0] I/O, U Test Outputs VDD (Core) Input +3.3 Volt DC Supply for Core Logic (7 pins) 11, 25, 59, 87, 101, 108, 119, VDD 147, 152, 166, 175, 194, 202 Input +3.3 Volt DC Supply for I/O Pads (13 pins) 18, 46, 80, 106, 140, 171, 198 Input Ground for Core Logic (7 pins) Input Ground for I/O Pads (13 pins) Power Pins 3, 39, 73, 96, 130, 159, 184 VSS (Core) 7, 32, 66, 94, 99, 117, 121, VSS 149, 154, 162, 180, 189, 207 30 Zarlink Semiconductor Inc. MVTX1100 13.1 Data Sheet STRAP Options The Strap options are relevant during the initial power-on period, when reset is asserted. During reset, MVTX1100 will examine the boot strap address pin to determine its value and modify the internal configuration of the chip accordingly. “1” means Pull Up “0” means Pull Down with an external 1 K Ohm Default value is 1, (all boot strap pins have internal pull up resistor). Pin No(s) Symbol Name & Functions 206 (L_A[5]) Memory Size 1 - Memory size = 256 KB, 0 - Memory size = 512 KB 208 (L_A [6]) EEPROM 1 - NO EEPROM Installed 0 - EEPROM Installed1 1 (L_A [7]) MII Management via MDIO 1 - Enable 0 - Disable 5, 4 (L_A [10:9]) XLINK Speed 11 - 100 Mbps 10 - 200 Mbps 01 - 300 Mbps 00 - 400 Mbps (0 - Pull down, 1 - Pull up) 160 (L_A[15]) Ports 0-7 RMII/Serial 1 - RMII Mode for ports 0-7 0 - Serial mode for ports 0-7 151 (L_A[17]) Port 8 MII/Serial 1 - MII Mode for port 8 0 - Serial mode for port 8 150 (L_A[2]) Link Polarity Link Polarity for serial interface 1 - Active Low 0 - Active High 204 (L_A[3]) FDX Polarity Full/Half Duplex Polarity for serial interface 1 - Active Low 0 - Active High 205 (L_A[4]) SPD100 Polarity Speed polarity for serial interface 1 - Active Low 0 - Active High 2 (L_A[8]) Device ID Use in cascade mode only 133 (TST[2]) SBRAM Self Test For Board/System Manufacturing Test2 1 - Disable 0 - Enable Note 1: 1. If the MVTX1100 is configured from EEPROM preset (L_A[6] pulled down at reset), it will try to load its configuration from the EEPROM. If the EEPROM is blank or not preset, it will not boot up. The parallel port can be used to program the EEPROM at any time. Note 2: During normal power-up the MVTX1100 will run through an external SBRAM memory test to ensure that there are no memory interface problems. If a problem is detected, the chip will stop functioning. To facilitate board debug in the event that a system stops functioning, the MVTX1100 can be put into a continuous SBRAM self test mode to allow an operator to determine if there are stuck pins in the memory interface (using network analyzer). 31 Zarlink Semiconductor Inc. MVTX1100 14.0 DC Electrical Characteristics 14.1 Absolute Maximum Ratings Data Sheet Storage Temperature -65°C to +150C Operating Temperature -40°C to +85C Maximum Junction Temperature +125C Supply Voltage VDD with Respect to VSS +3.0 V to +3.6 V Voltage on 5V Tolerant Input Pins -0.5 V to (VDD + 3.3 V) Voltage on Other Pins -0.5 V to (VDD + 0.3 V) Caution: Stresses above those listed may cause permanent device failure. Functionality at or above these limits is not implied. Exposure to the Absolute Maximum Ratings for extended periods may affect device reliability. 14.2 DC Electrical Characteristics VDD = 3.0 V to 3.6 V (3.3v +/- 10%) TAMBIENT = -40C to +85C 14.3 Recommended Operating Conditions Symbol Parameter Description fOSC Frequency of Operation IDD VOH VOL Supply Current - @ 55 MHz, 8x100 M, 100% Full Duplex Traffic (VDD = 3.3V) Output High Voltage (CMOS) Min. Typ. Max. Unit 50 66 80 MHz 580 mA 2.4 Output Low Voltage (CMOS) 0.4 V VDD + 2.0 V VIH-TTL Input High Voltage (TTL 5 V tolerant) VIL-TTL Input Low Voltage (TTL 5 V tolerant) 0.8 V IIL Input Leakage Current (0.1 V < VIN < VDD) (all pins except those with internal pull-up/ pulldown resistors) 10 µA IOL Output Leakage Current (0.1 V < VOUT < VDD) 10 µA CIN Input Capacitance 5 pF Output Capacitance 5 pF I/O Capacitance 7 pF COUT CI/O 2.0 V θja Thermal resistance with 0 air flow 29.7 C/W θja Thermal resistance with 1 m/s air flow 28.8 C/W θja Thermal resistance with 2 m/s air flow 26.8 C/W θjc Thermal resistance between junction and case 12.6 C/W 32 Zarlink Semiconductor Inc. MVTX1100 14.4 Data Sheet Clock Frequency Specifications Symbol Parameter (Hz) C1 SCLK - Core System Clock Input 50 M C2 M_CLK - RMII Port Clock 50 M C3 M8_REFCLK - MII Reference Clock 25 M C4 L_CLK - Frame Buffer Memory Clock 50 M C5 M_MDC - MII Management Data Clock 2 C6 SCL - I C Data Clock Note: L_CLK = SCLK 1.56 M M_MDC = SCLK/32 50 K SCL = M_CLK/1000 Suggestion Clock rate for various configurations: Input Configuration Port 0-7 Port 8 Output SCLK M_CLK (RMII) M8_REF L_CLK M_MDC SCL 10 M RMII 10/100 M MII 50 M 50 M -- =SCLK =SCLK/32 50 K 100 M RMII Not Used 55 M 50 M -- =SCLK =SCLK/32 50 K 100 M RMII 10/100 M MII 60 M 50 M -- =SCLK =SCLK/32 50 K 100 M RMII 200 M MII 66.66 M 50 M 50 M =SCLK =SCLK/32 50 K 100 M RMII 300 M MII 75 M 50 M 75 M =SCLK =SCLK/32 50 K 100 M RMII 400 M MII 80 M 50 M 100 M =SCLK =SCLK/32 50 K 33 Zarlink Semiconductor Inc. MVTX1100 15.0 AC Timing Characteristics 15.1 Frame Buffer Memory Interface: Data Sheet L_D[31:0] Figure 6 - Framer Buffer Memory Interface Timing Symbol 50 MHz Parameter Min. (ns) Max. (ns) Note L1 L_D[31:0] input setup time 5 L2 L_D[31:0] input hold time 0 L3 L_D[31:0] output valid delay 1 8 CL = 30 pF L4 L_A[18:2] output valid delay 1 8 CL = 50 pF L6 L_ADSC# output valid delay 1 8 CL = 50 pF L8 L_WE# output valid delay 1 8 CL = 30 pF L9 L_OE# output valid delay 1 8 CL = 30 pF Table 3 - Frame Buffer Memory Interface Timing 34 Zarlink Semiconductor Inc. MVTX1100 15.2 Data Sheet Serial Timing Requirements Symbol 50 MHz Parameter Min. (ns) Max. (ns) Note: M1 M_[8:0]_[TX/RX]CLK Serial Input Clock M2 M[8:0]_RXD input setup time 4 M3 M[8:0]_RXD input hold time 1 M4 M[8:0]_CRS_DV input setup time 4 M5 M[8:0]_TXEN output delay time 1 11 CL = 30 pF M6 M[8:0]_TXD output delay time 1 11 CL = 30 pF M7 M[8:0]_LINK input setup time 4 Table 4 - Serial Timing Requirements 15.3 RMII Timing Requirements Symbol 50 MHz Parameter Min. (ns) Max. (ns) Note: M1 M_CLK Reference Input Clock M2 M[7:0]_RXD[1:0] input setup time 4 M3 M[7:0]_RXD[1:0] input hold time 1 M4 M[7:0]_CRS_DV input setup time 4 M5 M[7:0]_TXEN output delay time 1 11 CL = 30 pF M6 M[7:0]_TXD[1:0] output delay time 1 11 CL = 30 pF M7 M[7:0]_LINK input setup time 4 Table 5 - RMII Timing Requirements 35 Zarlink Semiconductor Inc. MVTX1100 15.4 Data Sheet MII Timing Requirements Figure 7 - Transmit Timing Symbol Time Parameter Min. Max. Unit 1 M8_TXCLK rise to M8_TXD[3:0] inactive delay 5 20 ns 2 M8_TXCLK rise to M8_TXD[3:0] active delay 5 20 ns 3 M8_TXCLK rise to M8_TXEN active delay 5 20 ns 4 M8_TXCLK rise of last M8_TXD bit to M8_TXEN inactive delay 5 20 ns 5 M8_TXCLK high wide 25 Inf. ns 6 M8_TXCLK low wide 25 Inf. ns M8_TXCLK input rise time require 5 ns M8_TXCLK input fall time require 5 ns *Inf. = infinite Table 6 - Transmit Timing Requirements 36 Zarlink Semiconductor Inc. MVTX1100 Data Sheet Figure 8 - Receive Timing Symbol Time Parameter Min. 1 M8_RXD[3:0] low input setup time 2 M8_RXD[3:0] low input hold time 3 M8_RXD[3:0] high input setup time 4 M8_RXD[3:0] high input hold time 5 M8_RXDV low input setup time 6 M8_RXDV low input hold time 7 M8_RXDV high input setup time 8 M8_RXDV high input hold time 9 M8_RXCLK high wide 10 M8_RXCLK low wide Max. 10 Unit ns 5 10 ns ns 5 10 ns ns 5 10 ns ns 5 ns 25 Inf. ns 25 Inf. ns M8_RXCLK input rise time require 5 ns M8_RXCLK input fall time require 5 ns Table 7 - Receive Timing Requirements 37 Zarlink Semiconductor Inc. D D1 = 0°-7° A E1 A2 E A1 L INDEX CORNER PIN 1 Notes: 1. Pin 1 indicator may be a corner chamfer, dot or both. 2. Controlling dimensions are in millimeters. 3. The top package body size may be smaller than the bottom package body size by a max. of 0.15 mm. 4. Dimension D1 and E1 do not include mould protusion. Package Code c Zarlink Semiconductor 2003 All rights reserved. ISSUE ACN DATE APPRD. Previous package codes: For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE