MCC PB605

MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
•
PB605
THRU
PB610
6 Amp Glass
Passivated Rectifier
50 to 1000 Volts
Glass Passivated chip
Low Forward Voltage
Any Mounting Position
Silver Plated Copper Leads
Surge Overload Rating Of 150 Amps
PB-6
Maximum Ratings
•
•
Operating Temperature: -55°C to +125°C
Storage Temperature: -55°C to +150°C
Microsemi
Catalog
Number
Device
Marking
PB605
PB61
PB62
PB64
PB66
PB68
PB610
PB605
PB61
PB62
PB64
PB66
PB68
PB610
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000v
B
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000v
C
E
D
G
+
AC
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
IF(AV)
6.0A
A
TJ = 50°C
IFSM
150A
8.3ms, half sine
VF
1.10V
IFM = 3.0A;
TJ = 25°C*
AC
-
A
DIMENSIONS
Maximum DC
Reverse Current At
IR
10µA
TJ = 25°C
Rated DC Blocking
1 mA
TJ = 100°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
DIM
A
B
C
D
E
G
INCHES
MIN
.578
.230
.750
.405
.038
.145
www.mccsemi.com
MAX
.618
.270
--.444
.042
---
MM
MIN
14.69
5.84
19.10
10.30
0.97
3.70
MAX
15.71
6.86
--11.30
1.07
---
NOTE
2PL
2PL
4PL/TYP
∅
PB605 thru PB610
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
20
2
1
10
.6
6
.4
4
.2
2
TJ=25°C
25°C
µAmps .1
1
Amps
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.4
.6
.8
1.0
1.1
40
60
80
100
120
140
1.2
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
12
300
10
250
8
200
150
6
Amps
Amps
100
4
50
2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
20
40
60
80
0
100
1
2
4
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
8 10
20
40
00
60 80 100
Cycles
120
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com