B40SR12424A/B/C/D/DP/H 12V Output DC/DC Converter, Box Type Package FEATURES Wide input voltage range, 18~60V 200W Output @ 18V~27V Vin range(for A/B/C/D/H) 300W Output @ 27~60V Vin range (for A/B/C/D/H) 300W Output @ 18V~60V Vin range(for DP) Full Load Efficiency up to 88.3% @48Vin Intergrated fuse holder (option) Parallel Connection of multiple units Box type package with metal base plate Package Dimension: 190.0x76.0x44.0mm (7.48”x2.99”x1.73”) Operating Temperature Range - 40°C to +75°C Input Reverse Polarity Protection Minimized Inrush current Input UVLO, Output OCL, Short circuit protection, OVP, OTP Enable on/off (option) 2250VDC Isolation IP67 protection for selective model RoHs Compliant ISO 9001, ISO 14001 certified manufacturing facility UL60950 CE Mark EMC compatible: EN12895, CISPR11 ClassA Electrical transient conduction: ISO7637-2 The B40SR12424, a wide input voltage range of 18~60V, and single isolated output converter, is the latest product offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. Such box type DCDC converter can provide 300W (200W at Vin < 27V for A/B/C/D/H), 12.4V regulated DC output voltage with full load efficiency up to 88.3% @48Vin; The B40SR12424 offers input UVLO, output over current limit, short circuit, output over voltage, over temperature, and input reverse polarity protections, It has an option for intergrated fuse holder and enable on/off function. It also has parallel function; and allows a wide operating temperature range of –40°C to +75°C. With creative design technology and optimization of component placement, this converter possess outstanding electrical and thermal performance, as well as high reliability under extrmely harsh operating conditions. The B40SR12424 meet IP67 protection(refer to “water protection level” specification). Input Characteristics Item Condition Continuous Input Voltage Max Input voltage Min. Typ. Max. Unit 18 48 60 VDC 80 VDC 10 minutes, normal operating Input Under-Voltage Lockout, Turn-On Voltage Threshold 16 17 18 VDC Input Under-Voltage Lockout, Turn-Off Voltage Threshold 14 15 16 VDC 1 2 3 VDC Vin=18V, 100% Load(for A/B/C/D/H) 12.6 13.1 A Vin=18V, 100% Load(for DP) 18.8 19.5 A Vin=24V 85 110 mA Vin=48V 40 70 mA Vin=48V, enable off (C version) 8 15 mA Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off converter input current Reflected input ripple current Vin=48V, Vpp Max Reverse Polarity Input Voltage Max Inrush current Internal Input Fuse DS_B40SR12424_10282016 Ø 6.35mm*31.75mm 0.2 A 60 VDC 10 A 250V/30A Fast-acting fuse E-mail: [email protected] http://www.deltaww.com/dcdc P1 Output Characteristics Item Operating Output Current Range Output Voltage Set Point Output Voltage Ripple and Noise, Output Current Limit Current share accuracy Start-up time(start _up time by Vin) Start-up time(start _up time by Enable) Rise time Output Voltage Protection Conditions Vin=18V~27V(for A/B/C/D/H) Vin=27V~60V(for A/B/C/D/H) Vin=18V~60V(for DP) Vin=24V,36V,48V, Io=0 Vin=24V, Io=16A(for A/B/C/D/H) Vin=24V, Io=24A(for DP) Vin=36V,48V, Io=24A Vin=36V, 48V, peak to peak, 20MHz bandwidth RMS Vin=24V, Io=16A(for A/B/C/D/H) peak to peak, 20MHz bandwidth RMS,Vin=24V, Io=16A(for A/B/C/D/H) Vin=24V, Io=24A(for DP) peak to peak, 20MHz bandwidth RMS,Vin=24V, Io=24A(for DP) Vin=24V (for A/B/C/D/H) Vin=24V (for DP) Vin=36V, 48V Vin=36V, 48V, 24A for each module Vin=48V,full load (for A/B/C/D/DP/H) Vin=48V,full load (for C) General Characteristics Isolation Voltage, Isolation Resistance, Input to Output Isolation Capacitance, Input to Output Switching Frequency MTBF Weight DS_B40SR12424_10282016 16.5 25 25 13 Vin=24V, 8A to 12A load dynamic, 0.1A/us slew rate(for A/B/C/D/H) Output Voltage Current Transient, positive Vin=36V,48V, 12A to 18A load dynamic, 0.1A/us slew rate and nagetive voltage step Vin=24V, 12A to 18A load dynamic, 0.1A/us slew rate(for DP) Maximum Output Capacitance ESR>10mohm Output overshoot Efficiency @ 100% Load(16A) Vin=24V(for A/B/C/D/H) Efficiency @ 100% Load(24A) Vin=24V(for DP) Efficiency @ 100% Load(24A) Vin=36V Efficiency @ 100% Load(24A) Vin=48V Efficiency @ 60% Load(9.6A) Vin=24V(for A/B/C/D/H) Efficiency @ 60% Load(14.4A) Vin=24V(for DP) Efficiency @ 60% Load(14.4A) Vin=36V Efficiency @ 60% Load(14.4A) Vin=48V Item Min. 0 0 0 12.4 12.13 12.0 12.0 Conditions Input to Output, Input to Case Ouput to Case Typ. 12.6 12.33 12.2 12.2 Max. 16 24 24 12.8 12.53 12.4 12.4 Unit A A A V V V V 100 160 mV 35 50 mV 60 90 mV 20 30 mV 70 100 mV 25 18.5 28 28 6 750 250 30 15 35 20.5 31 31 10 900 350 50 17 mV A A A % mS mS mS V 100 150 mV 100 150 mV 160 86.8 86.5 86.5 86.3 87.6 88.2 87.8 87.3 88.8 88.5 88.5 88.3 89.6 90.2 89.8 89.3 Min. Typ. 10 Ta=25ºC, 80%load 6000 175 0.7 900 260 mV 5000 3 µF % % % % % % % % % Max. 2250 550 Unit VDC VDC MΩ pF KHz Mhours g E-mail: [email protected] http://www.deltaww.com/dcdc P2 Environmental Specifications Parameter Storage Temperature Range Operating Temperature Range Over Temperature Protection Humidity (non condensing) Water Protection Level Vibration Shock Emission Immunity ESD Conditions Ambient Temperature NTC Temperature Min. -40 -40 Max. +125 +75 118 Unit ℃ ℃ ℃ % rel. H 95 With connector&fuseholder for B IP67 Without connector&fuseholder for A/C/D/DP/H IEC 60068-2-6 10G/15~200HZ/3 PLANES IEC 60068-2-27 50G 3 PLANES EN12895 30-1000MHz 34-45dBuV/m EN12895, EN61000-4-3 10V/m /27-1000MHz AM; 10V/m /900MHz PM EN12895, EN61000-4-2 Direct: ±2KV ±4KV; Air: ±2KV ±4KV ±8KV Notes 1 2 Specifications typical at Ta=+25℃, nominal input voltage and rated full load output current unless otherwise noted. Specifications are subject to change without notice. ELECTRICAL CURVES Figure 1: Efficiency vs. Output current Vin=24V,36V,48V (for A/B/C/D/H) @ Figure 2: Loss vs. Output current @ Vin=24V,36V,48V (for A/B/C/D/H) Figure 3: Efficiency vs. Output current Vin=24V,36V,48V (for DP) @ Figure 4: Loss vs. Output current @ Vin=24V,36V,48V(for DP) DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P3 ELECTRICAL CURVES Figure 5: Dynamic response to load step 12A~18A with 0.1A/uS slew rate at 48Vin CH1:VOUT, 100mV/div, 500uS/div Figure 6: Vout start up with Vin on at 48Vin,24A Iout, TOP:VIN, 20V/div, 200mS/div BOTTOM: VOUT, 5V/div, 200mS/div Figure 7: Output ripple & noise at 48Vin, 24A Iout CH1:VOUT, 50mV/div, 5uS/div Figure 8: Output over voltage protection at 48Vin, 24A Iout CH1:VOUT, 10V/div, 50mS/div Figure 9: Input current vs. Input voltage @ Vin=18V~27V, 200W; Vin=27V~60V, 300W(for A/B/C/D/H) Figure 10: Output voltage vs. Output current OCL Performance( for A/B/C/D/H) DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P4 ELECTRICAL CURVES (continous) Figure 11: Input current vs. Input voltage @ Vin=18V~60V, 300W (for DP) Figure 12: Output voltage vs. Output current OCL Performance (for DP) Figure 13: Output voltage vs. Output current @Vin=48V. Droop function. Figure 14: Current share accuracy vs. Total output current 2 in parallel. Figure 15: Inrush current @ Vin=48V CH1:Iin, 2A/div, 200nS/div Max current 2.7A, I2t=1.24E-7 A²S DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P5 FEATURES DESCRIPTIONS Output Over-Current Limit and Short Protection The modules include internal output over-current limit (OCL) and short circuit protection (SCP) circuits, the OCL set point is lower than that of the SCP; The response of SCP circuit is much fast than that of the OCL circuit. The slowly increase of the output current will let module enter OCL protection when the current exceeds the OCL set point, while the fast increase of the output current will let module enter SCP when the current exceeds the SCP set point. When the modules enter OCL protection, the output voltage will decrease while the output current is kept constant, the output voltage will soft start to set point when the overload condition is removed. The module will enter hiccup mode when it triggers the SCP set point. The module will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is removed. Output Over-Voltage Protection The power module includes an internal output over-voltage protection(OVP) circuit, which monitors the voltage on the output terminals. If this voltage exceeds the OVP set point, the module will shut down, and then restart after a fixed delay time (hiccup mode), please refer to figure8 for detail. Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the preset temperature threshold the module will shut down,and all components will not exceed their absolute maximum temperature ratings.The module will restart after the temperature is within specification. Remote On/Off B40SR12424C has Enable control function. This Enable PIN is designed on the primary side of converter, the converter will turn on when the Enable PIN connected to VIN+, and turn off when the Enable PIN connected to VIN- or floating. Figure 16: suggested Enable connection Input Reverse Voltage Protection The input reverse voltage protection is provided by an diode on the input line, the standoff voltage for the reverse protection shall be no less than -60V. DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P6 DESIGN CONSIDERATIONS Parallel connection of multiple units Two units parallel operation is verified, please contact Delta if more than two units need to be paralleled. While parallelling multiple units, the impedance of the cables from unit to junction point of each unit should be within ±5% of each other. Figure 17: suggested parallel connections EMC 80 80 70 70 60 60 50 EN 12895_R E_10m QP 40 30 20 10 0 30M Leve l i n dB 米 V / Leve l i n dB 米 V / The converter has the internal EMI filters and meet the EMC standards EN12895 30-1000MHz 34-45dBuV/m.The test result is showed as below Conditions: Vin=48V, Io=24A, 10m measure distance EN 12895_R E_10M _Auto EN 1 2 8 9 5 _ R E_ 1 0 M _ Au to 50 EN 12895_R E_10m QP 40 30 20 10 50 60 80 100M 200 300 400 500 Frequenc y in H z Figure 18: test result(Vertical) 800 1G 0 30M 50 60 80 100M 200 300 400 500 800 1G Fre q u e n c y in H z Figure 19: test result(Horizontal) Fuse replacement For the versions with the intergratted the fuse holder, when the fuse needs to be replaced, it can be taked down in an anticlockwise direction by slotted type screwdrivers . Recommended fuse replacement P/N: Littlefuse 0314030.MXP DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P7 THERMAL CONSIDERATION The thermal curve (Figure21~23) is based on a 250x300x5 AL table, shown as below figure. Figure 20: Thermal consideration THERMAL CURVE Figure 21: Output Current vs. Ambient temperature @Vin=24V DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P8 THERMAL CURVE DS_B40SR12424_10282016 Figure 22: Output Current vs. Ambient temperature @ Vin=36V Figure 23: Output Current vs. Ambient temperature @ Vin=48V E-mail: [email protected] http://www.deltaww.com/dcdc P9 THERMAL CONSIDERATION The following figure shows the location to monitor the temperature of base plate. Before customer decides to use this DCDC converter, a thermal evaluation need to be did to make sure the temperature of base plate is lower than that read from below thermal curves (Figure25~27 base on different input voltage). Figure 24: Thermal consideration THERMAL CURVE Figure 25: Output Current vs. Base Plate temperature @Vin=24V DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P10 THERMAL CURVE DS_B40SR12424_10282016 Figure 26: Output Current vs. Base Table temperature @ Vin=36V Figure 27: Output Current vs. Base Table temperature @ Vin=48V E-mail: [email protected] http://www.deltaww.com/dcdc P11 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-4213) B40SR12424A Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-4213) B40SR12424AC DS_B40SR12424_10282016 Connector kit : Housing: 42816-0412 Terminal: 42815-0042 E-mail: [email protected] http://www.deltaww.com/dcdc P12 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) Connector: Deutsch DTP Receptacles X.XX±0.25 ( X.XXX±0.010) B40SR12424B (DEUTSCH P/N :DTP04-4P) Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) Connector: Deutsch DTP Receptacles Connector kit : Housing: DTP06-4S Wedge lock: WP-4S Terminal: 0462-203-12141 X.XX±0.25 ( X.XXX±0.010) (DEUTSCH P/N :DTP04-4P) B40SR12424BC DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P13 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + 5 ENABLE All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010) Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-5213) B40SR12424C Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + 5 ENABLE All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-5213) B40SR12424CC DS_B40SR12424_10282016 Connector kit : Housing: 42816-0512 Terminal: 42815-0042 E-mail: [email protected] http://www.deltaww.com/dcdc P14 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010) Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-4213) B40SR12424D\DP Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010) Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-4213) B40SR12424DC\DPC DS_B40SR12424_10282016 Connector kit : Housing: 42816-0412 Terminal: 42815-0042 E-mail: [email protected] http://www.deltaww.com/dcdc P15 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function / Wire Color 1 OUTPUT – , YELLOW 2 OUTPUT +, BLUE 3 INPUT -, BLACK 4 INPUT +, RED All dimensions in mm (inches) Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010) B40SR12424H Physical Outline Case Size Case Material DS_B40SR12424_10282016 : : 190.0x76.0x44.0 mm (7.48”x2.99”x1.73”) Case: PC; Plate: AL6063 E-mail: [email protected] http://www.deltaww.com/dcdc P16 Part Numbering System B Form Factor BBox 40 S R 124 24 A C Input Voltage Number of Outputs Product Series Output Voltage Output Current Option Code Option Fitting 40 – 18V~60V S– Single R– Regular 124 – 12.4V 24 – 24A With Built-in fuse holder Enable pin Sealed connector & fuse holder Connector Kit A YES NO NO 1xhousing+ 4 terminals B YES NO YES 1xhousing+ 4 terminals C NO YES NO 1xhousing+ 5 terminals D NO NO NO 1xhousing+ 4 terminals DP NO NO NO 1xhousing+ 4 terminals H YES NO NO N/A Model List Input Voltage Range Input EFF @48VIN 100% LOAD Output B40SR12424(A\B\C\D\H) 18V~60V 13.1A 12.4V 24A 88.3% B40SR12424(DP) 18V~60V 19.5A 12.4V 24A 88.3% CONTACT: www.deltaww.com/dcdc Email: [email protected] USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999 Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6224 Fax: +886 3 4513485 WARRANTY Delta offers a two (2) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_B40SR12424_10282016 E-mail: [email protected] http://www.deltaww.com/dcdc P17