CT Micro CTM3063VT1 Zero cross 4-pin mini-flat phototriac optocoupler Datasheet

CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Features
•
High isolation 3750 VRMS
•
Peak Breakdown Voltage
600V – CTM3061,3062,3063
800V – CTM3081,3082,3083
•
Temperature range - 55 °C to 100 °C
•
Regulatory Approvals
•
Description
The CTM3061, CTM3062, CTM3063, CTM3081,
CTM3082 and CTM3083 series consists of a Zero
Cross Photo Triac optically coupled to a gallium
arsenide Infrared-emitting diode in a 4-lead Mini Flat
package.
Applications
UL - UL1577 (E364000)
•
Motor Controls
VDE - EN60747-5-5(VDE0884-5)
•
Lamp ballasts
CQC – GB4943.1, GB8898
•
Static AC Power Switch
IEC60065, IEC60950
•
Solenoid/ Valve Control
Green Package
Package Outline
CT Micro
Proprietary & Confidential
Schematic
Page 1
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Absolute Maximum Rating at 25oC
Symbol
Parameters
Ratings
Units
3750
VRMS
VISO
Isolation voltage
TOPR
Operating temperature
-55 ~ +100
oC
TSTG
Storage temperature
-55 ~ +125
oC
TSOL
Soldering temperature
260
oC
PTOT
Total power dissipation
200
mW
Forward current
60
mA
1
A
6
V
Notes
Emitter
IF
IF(TRANS)
Peak transient current
(≤1µs P.W,300pps)
VR
Reverse voltage
PD
Power dissipation
100
mW
Power dissipation
300
mW
CTM3061,3062,3063
600
V
CTM3081,3082,3083
800
V
1
A
Detector
PD
VDRM
ITSM
Off-State Output Terminal Voltage
Peak Repetitive Surge Current
CT Micro
Proprietary & Confidential
Page 2
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Electrical Characteristics T
A
= 25°C (unless otherwise specified)
Emitter Characteristics
Symbol
Parameters
Test Conditions
Min
Typ
Max
Units
VF
Forward voltage
IF=10mA
-
-
1.5
V
IR
Reverse Current
VR = 6V
-
-
5
µA
Input Capacitance
f= 1MHz
-
45
-
pF
Min
Typ
Max
Units
-
-
500
nA
-
-
500
µA
CIN
Notes
Detector Characteristics
Symbol
IDRM1
Parameters
Peak Blocking
CTM3061,62,63
Current
CTM3081,82,83
Test Conditions
IF= 0mA, VDRM= Rated VDRM
Notes
IF= Rated IFT, VDRM= Rated
IDRM2
Inhibit Leakage Current
VINH
Inhibit Voltage
IF= Rated IFT,
-
-
20
V
VTM
Peak On-State Voltage
IF= Rated IFT, ITM= 100mA
-
-
3
V
1000
-
-
600
-
-
dv/dt
VDRM
Critical Rate of
CTM3061,62,63
Rise off-State
CTM3081,82,83
V/µs
VPEAK= Rated VDRM
Voltage
Transfer Characteristics
Symbol
Parameters
Test Conditions
Min
Typ
Max
Units
-
-
15
-
-
10
-
-
5
-
380
-
µA
1x1011
-
-
Ω
-
0.25
-
pF
Notes
CTM3061,
CTM3081
Input
CTM3062,
IFT
Trigger
Terminal Voltage = 3V
mA
CTM3082
Current
CTM3063,
CTM3083
IH
Holding Current
RIO
Isolation Resistance
VIO= 500VDC
CIO
Isolation Capacitance
f= 1MHz
CT Micro
Proprietary & Confidential
Page 3
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Typical Characteristic Curve
CT Micro
Proprietary & Confidential
Page 4
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Typical Characteristic Curve
CT Micro
Proprietary & Confidential
Page 5
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Package Dimension Dimensions in mm unless otherwise stated
Recommended Solder Mask Dimensions in mm unless otherwise stated
CT Micro
Proprietary & Confidential
Page 6
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Marking Information
CT
3063
VYWWK
Note:
CT
3063
: Denotes “CT Micro”
: Product Number
V
Y
WW
K
: VDE Option
: Fiscal Year
: Work Week
: Manufacturing Code
Ordering Information
CTM30XX(V)(Z)
XX = Part No. (XX=83, 82, 81, 63, 62 and 61)
V = VDE Option ( V or None)
Z = Tape and reel option (T1 or T2)
Option
Description
Quantity
T1
Surface Mount Lead Forming – With Option 1 Taping
3000 Units/Reel
T2
Surface Mount Lead Forming – With Option 2 Taping
3000 Units/Reel
CT Micro
Proprietary & Confidential
Page 7
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Carrier Tape Specifications Dimensions in mm unless otherwise stated
Option T1
Option T2
CT Micro
Proprietary & Confidential
Page 8
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
Reflow Profile
Profile Feature
Pb-Free Assembly Profile
Temperature Min. (Tsmin)
150°C
Temperature Max. (Tsmax)
200°C
Time (ts) from (Tsmin to Tsmax)
60-120 seconds
Ramp-up Rate (tL to tP)
3°C/second max.
Liquidous Temperature (TL)
217°C
Time (tL) Maintained Above (TL)
60 – 150 seconds
Peak Body Package Temperature
260°C +0°C / -5°C
Time (tP) within 5°C of 260°C
30 seconds
Ramp-down Rate (TP to TL)
6°C/second max
Time 25°C to Peak Temperature
8 minutes max.
CT Micro
Proprietary & Confidential
Page 9
Rev.2
Mar, 2015
CTM3083, CTM3082, CTM3081
CTM3063, CTM3062, CTM3061
600V/800V Zero Cross 4-Pin Mini-Flat Phototriac Optocoupler
DISCLAIMER
CT MICRO RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS
HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. CT MICRO DOES NOT ASSUME ANY LIABILITY
ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN;
NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS.
______________________________________________________________________________________
DISCOLORATION MIGHT OCCUR ON THE PACKAGE SURFACE AFTER SOLDERING, REFLOW OR LONG
TERM USE. THIS DOES NOT IMPACT THE PRODUCT PERFORMANCE NOR THE PRODUCT RELIABILITY.
CT MICRO ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT EXPRESS WRITTEN APPROVAL OF CT MICRO INTERNATIONAL CORPORATION.
1. Life support devices or systems are devices or
2. A critical component is any component of a life
systems which, (a) are intended for surgical
support device or system whose failure to perform
implant into the body, or (b) support or sustain life,
can be reasonably expected to cause the failure of
or (c) whose failure to perform when properly used
the life support device or system, or to affect its
in accordance with instruction for use provided in
safety or effectiveness.
the labelling, can be reasonably expected to result
in significant injury to the user.
CT Micro
Proprietary & Confidential
Page 10
Rev.2
Mar, 2015
Similar pages