Artesyn NAN40-7608 Dual and triple output 40 watt ac/dc universal input switch mode power supply Datasheet

NAN40 SERIES
Dual and triple output
•
•
•
•
•
•
5.0 x 3.0 x 1.2 inch package (1U applications)
Ideal for high volume designs
Industry standard package
Overvoltage and short circuit protection
40W with free air convection
EN55022, EN55011 conducted emissions level B
The NAN40 series are 40W universal input AC/DC power supplies on a 5 x 3
inch card with a maximum component height of 1.2 inch for use in 1U
applications. These series are available with a wide range of models in the
industry standard 5 x 3 inch footprint at low cost making the series ideal for new
and existing high volume communication and industrial applications. The
NAN40 series provide 40W of output power with free air convection cooling with
a peak output of 50W for a maximum duration of 60 seconds. The NAN40
series are designed for use in high volume low power data networking,
computer and telecom applications such as hubs, routers, POS terminals, cable
modems and PABX's. This list is not exclusive as the generic feature set of both
series with industry standard output configurations provide a solution for most
high volume applications including many industrial applications.
[ 2 YEAR WARRANTY ]
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Line regulation
Main output
Auxiliary outputs
±0.5%
±1.0%
Total regulation
Main output
Auxiliary outputs
±3.0%
±5.0%
Overshoot/undershoot
At turn-on
<10%
Transient response
+5.1V
(1.5A to 3A step)
Temperature coefficient
±150mV max. dev.,
500µs recovery
±0.02%/°C
Overvoltage protection
+5.1V output
6.25V ±0.75Vout
Output power limit
Primary power
limited
50W Pout, min.
110W Pin, max.
Short circuit protection
Multiple output
30 seconds
INPUT SPECIFICATIONS
Input voltage range
Universal input
Input frequency range
Input surge current
Safety ground
leakage current
90 to 264VAC
120 to 370VDC
47Hz to 440Hz
110VAC, cold start
230VAC, cold start
110VAC, 60Hz
230VAC, 50Hz
15A
32A
0.2mA
0.4mA
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Hold-up time
Certificate No. PS/605108
PAGE 1
110VAC
230VAC
10ms @ 40W
60ms @ 40W
Efficiency
Isolation voltage
68% min. @ 40W
Input/output
Input/chassis
Switching frequency
Approvals and
standards
(See Note 8)
MTBF
3000VAC
1500VAC
Variable
VDE0805, EN60950, IEC950
BABT, IEC1010, UL1950
CSA C22.2 No. 950
Weight
200g (7.06oz)
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0°C to +70°C
Non-operating
-40°C to +85°C
0°C to 50°C ambient,
40W
convection cooled
50°C to 70°C,
Derate linearly
ambient conv. cooled
to half load
Peak (0°C to 50°C) max. 60s
50W
Relative humidity
Non-condensing
Altitude
Operating
Non operating
Vibration
Three orthogonal axes,
2.4G rms
random vibration, 10
5Hz to 500Hz
minute test for each axis
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
level B
level A
criteria 2
criteria 2
criteria 2
criteria 2
criteria 2
criteria 2
GENERAL SPECIFICATIONS
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076
Licence No. 70567, 1076 and 90354
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
5% to 95% RH
10,000 feet max.
30,000 feet max.
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
40W AC/DC
40 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENT
OUTPUT
(1)
PEAK
(2)
FAN
RIPPLE
(3)
TOTAL
(4)
REG.
MODEL NUMBER
(5)
VOLTAGE
MAX
+ 5.1V (IA)
3A
7A
4A
50mV
±3.0%
+12V (IB)
2A
3A
2A
120mV
±5.0%
–12V (IC)
0.35A
1A
0.5A
120mV
±5.0%
+5.1V (IA)
3A
7A
4A
50mV
±3.0%
+12V (IB)
2A
3A
2A
120mV
±5.0%
–5V (IC)
0.35A
1.0A
0.5A
50mV
±5.0%
+5.1V (IA)
3A
7A
4A
50mV
±3.0%
+12V (IB)
2A
3A
2A
120mV
±5.0%
NAN40-7608
(5)
NAN40-7607
(5)
NAN40-7629
(5)
(B)
Notes
Mechanical notes
1
2
A Ground pad encircling mounting hole near P1 allows system grounding
through a metal stand-off of up to 8mm max. diameter to metal chassis.
B A standard L-bracket and cover is available for mounting, which contains
all screws, connectors and necessary mounting hardware. Order part
number ‘NAL40 COVER KIT’.
3
4
5
6
7
8
Natural convection cooling (40W maximum).
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation
limits.
Forced air, 20CFM at 1 atmosphere, 50W maximum.
Figure is peak-to-peak. Output noise measurements are made across a
50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF
capacitor.
Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits and output voltages adjusted to their factory settings. For multiple
output units to maintain stated regulation then:
0.25 ≤ IA / IB ≤ 5, for IB > 0.3A
0.50 ≤ IA / IB ≤ 5, for IB < 0.3A
Minimum load must also be 4W to achieve design MTBF.
For maximum output current IC on triple-output models, i.e. for:
IC = IMax., then IA min. ≥ 0.5A and IB ≥ IC.
Derating curve is application specific for ambient temperatures >50°C, for
optimum reliability, no part of the heatsink should exceed 120°C, and no
semiconductor case temperature should exceed 130°C.
Caution: allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5.00
(127.00)
0.156 (3.96) Dia. (4 Places)
J2
F1
F3.15A, 250VAC
1
3.00
(76.20)
2.55
(64.80)
T1
1
J1
P1
0.22
(5.59)
4.55
(115.80)
MAXIMUM COMPONENT
HEIGHT 1.2 inches
0.22
(5.59)
ALL DIMENSIONS IN INCHES (mm)
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Neutral
Pin 2
No Pin
Pin 3
AC Line
P1
Pin 1
Safety Ground
OUTPUT PIN CONNECTIONS
J2
DUAL
TRIPLE
P1
+12V
V (B)
P2
+5.1V
V (A)
P3
+5.1V
V (A)
P4
Return
Return
P5
Return
Return
P6
N/C
V (C)
DERATING CURVE (See Notes 6, 7)
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
25W
NATURAL
CONVECTION
COOLING
4W
20W
4W MIN. LOAD TO ACHIEVE DESIGN MTBF
0°C 10°C
20°C
30°C
40°C
50°C
60°C
70°C
Available Output Power V's Ambient Temperature
Data Sheet © Artesyn Technologies® 2001
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 2
BTO_DS_NAN40_20011119.PDF
AC (J1) mating connector
Molex 09-50-3031 or equiv. with Molex 08-50-0105 or equiv. crimp terminals.
DC (J2) mating connector
Molex 09-50-3061 or equiv. with Molex 08-50-0164 or equiv. crimp terminals.
Similar pages