Emerson Network Power NLP65-9608J Universal input Datasheet

Embedded Power for
Business-Critical Continuity
Rev.06.02.08
NLP65 Series
1 of 4
NLP65 Series
Single, dual,
and triple output
Total Power:
65 - 75W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc*
# of Outputs: Single, dual,
triple
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
•
Universal Input
3" x 5" footprint
Low profile fits 1U applications
EN61000-3-2 compliance
option (HCC)
Overvoltage and short circuit
protection
65 W with free air convection
cooling
EN55022, EN55011 conducted
emissions level B
EN61000-4-2,-3,-4, -5, -6
immunity compliant
RoHS compliant
LPX80 enclosure kit available
2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 1040100-3336-0096
Licence No. 114404
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
China Compulsory
Certification 60950
*NLP65-76xx version only
Input
Input voltage range
Universal input,
(See Note 2)
NLP65-76xx version only
Input frequency range
85-264 Vac
120-370 Vdc
47-63 Hz
Input current
(cold start)
120 Vac
230 Vac
17 A max.
32 A max.
Safety ground
leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
0.7 mA
1.4 mA
Input current
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
1.05 A rms
0.51 A rms
1.40 A rms
0.80 A rms
Input fuse
UL/IEC127
S3.15 A, 250 Vac In live and neutral
Total regulation
(line and load)
Rise time
Main output
Auxiliary outputs
At turn-on
±2.0%
±5.0%
1.0 s, max
Transient response
Main output
25% step
at 0.1 A/μs
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
Output
Temperature coefficient
±0.02%/°C
Overvoltage protection
Main outputs
125%, ±10%
Short circuit protection
Minimum output current
Cyclic operation
Single and multiple
Continuous
(See Note 6)
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
Rev.06.02.08
NLP65 Series
2 of 4
EMC Charateristics (11, 12)
Conducted emissions
EN55022, FCC part 15
Level B
Radiated emissions
EN55022, FCC part 15
Level A
ESD air
EN61000-4-2, level 3
Perf. criteria 1
ESD contact
EN61000-4-2, level 4
Perf. criteria 1
Surge
EN61000-4-2, level 3
Perf. criteria 1
Fast transients
Radiated immunity
EN61000-4-4, level 3
EN61000-4-3, level 3
Perf. criteria 1
Perf. criteria 2
Conducted immunity
EN61000-4-6, level 3
Perf. criteria 2
Hold-up time
120 Vac, 60 Hz
230 Vac, 50 Hz
16 ms @ 65 W
78 ms @ 65 W
Efficiency
120 Vac, 65 W
72% typical
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency
Fixed
100 kHz, ±5 kHz
General Specifications
Approvals and standards EN60950, VDE0805
(see Notes 9, 13)
IEC950, UL1950, CCC60950
CSA C22.2 No. 950
Weight
283 g (10 oz)
MTBF demonstrated
MIL-HDBK-217F
150,000 hours min
Environmental Specifications
Thermal performance
(see Notes 1, 3, 10)
Operating ambient,
0 °C to +70 °C
(See derating curve)
Non-operating
-40 °C to +85 °C
50 °C to 70 °C ambient,
Derate to
convection cooled
50% load
0 °C to 50 °C, ambient,
65 W
convection cooled
0 °C to 50 °C ambient,
75 W
20 CFM forced air (See Note 10)
Peak (0 °C to +50 °C, 60 s) See table
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max
30,000 feet max
Vibration (see Note 5)
5-500 Hz
2.4 G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
DERATING CURVE
Output Power (Watts)
75W
20 CFM FORCED AIR COOLING
65W
NATURAL
CONVECTION
COOLING
0°C
38W
32W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
Embedded Power for
Business-Critical Continuity
Output
Voltage
Output Current
Total
Non-harmonic
Regulation (6)
Corrected
Harmonic
Corrected
Ground
Pin (12, 14, 17)
NLP65-7608J
NLP65-9608J
NLP65-X608GJ
NLP65-7610J
NLP65-9610J
NLP65-X610GJ
NLP65-7620J
NLP65-9620J
NLP65-X620GJ
NLP65-7629J
NLP65-9629J
NLP65-X629GJ
Max (1)
Peak (3)
Fan (10)
+5 V (IA)
7.5 A
9.1 A
8A
50 mV
±2.0%
+12 V (IB)
2.5 A
3.3 A
3A
150 mV
±5.0%
–12 V
0.65 A
0.81 A
0.8 A
120 mV
±5.0%
+5 V (IA)
7.5 A
9.1 A
8A
50 mV
±2.0%
+15 V (IB)
2.2 A
2.9 A
2.5 A
150 mV
±5.0%
–15 V
0.65 A
0.85 A
0.8 A
150 mV
±5.0%
+5 V
7.0 A
9.1 A
8.0 A
50 mV
±2.0%
+24 V
1.5 A
2.6 A
2.0 A
240 mV
±5.0%
+12 V
0.7 A
1.0 A
1.0 A
120 mV
±5.0%
+5 V (IA)
7A
9.1 A
8A
50 mV
±2.0%
+24 V (IB)
2A
2.6 A
2A
240 mV
±5.0%
+5 V (IA)
7A
9.1 A
8A
50 mV
±2.0%
+12 V (IB)
2.5 A
3.3 A
3A
150 mV
±5.0%
+5 V
10 A
13 A
12 A
50 mV
±2.0%
NLP65-7605J
NLP65-9605J
NLP65-X605GJ
+12 V
5.4 A
7A
6.5 A
120 mV
±2.0%
NLP65-7612J
NLP65-9612J
NLP65-X612GJ
+15 V
4.4 A
5.7 A
5.3 A
150 mV
±2.0%
NLP65-7615J
NLP65-9615J
NLP65-X615GJ
+24 V
2.7 A
3.5 A
3.5 A
240 mV
±2.0%
NLP65-7624J
NLP65-9624J
NLP65-X624GJ
Ripple (4)
NLP65-3322J
Notes
1
Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-X610J
must not exceed 62.5 Watts continuous output power with natural convection.
Model NLP65-X620J not to exceed 65 Watts continuous output power with
natural convection. Model NLP65-3322J must not exceed 60 Watts continuous
output power with natural convection.
2 When the input voltage is less than 90 Vac the operating temperature range is
0 °C to +40 °C. The ripple and regulation specifications may not be met.
3 Peak output current lasting less than 60 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
4 Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 μF electrolytic capacitor and a 0.1 μF ceramic
capacitor.
5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
Hz to 500 Hz.
6 A minimum load on the main output is required for proper start up. For
multiple outputs and single +5V output, the minimum load on the +5 V is 0.2
A. For single outputs greater than +5 V the minimum load is 0.1 A. To
maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A.
7 For optimum reliability, no part of the heatsink should exceed 120 oC, and no
semiconductor case temperature should exceed 130 oC.
8 CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
9 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10 Maximum continuous output power for all multiple output models must not
exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling.
Model Numbering Options
1
2
3
The enclosure version includes: IEC connector, on/off switch, wire harness
output connector and fitted cover. To order, please add the suffix ‘E’ the model
number, e.g. NLP65-9608EJ. See NLP65 enclosure for details.
A Safety earth ground pin and ground choke are available as an option.
To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ.
To order an enclosure kit (unfitted), order the part number LPX80.
11 Conducted and radiated emissions testing were performed using the standard
EN55022 set-up with a stand alone NLP65 unit placed on a grounded metal
plate with a line choke on the AC input and ground wires (i.e. the wires are
looped through an EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet
with an integral line filter in the system chassis or to install a line choke on the
input wires as close as possible to AC entry point of the system chasssis. Please
contact the applications group at Artesyn for assistance with EMI compliance.
12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option.
J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6 is
a ground choke and JP10 is a jumper. This option is intended for use in nonmetallic chassis applications where grounding is not possible via the mounting
screws. The ground choke is provided to assist system EMC compliance. When
performing conducted emissions testing on stand alone units, the ‘G’ option is
required to meet level B. To order simply add the suffix ‘G’ to the standard
model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for
both the PFC and non-PFC versions.
13 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in
the end use product.
14 The NLP65-9608J is available with an enclosure. To order an enclosed version,
see model numbering options below.
15 No PFC version, EN61000-3-2 is not applicable to this model.
16 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
17 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerversion.com.
Rev.06.02.08
NLP65 Series
3 of 4
Embedded Power for
Business-Critical Continuity
Americas
Mechanical Drawing
5.00
(127.00)
4.550
(115.57)
0.225
(5.715)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Rev.06.02.08
NLP65 Series
4 of 4
Europe (UK)
J1
J3
3
N
1
L
1
3.00
(76.20)
6
2.550
(64.770)
Asia (HK)
T1
J2
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
C19
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
Mounting
Hole Diameter
0.156 (4.00)
TOLERANCE: .xxx
.xx
0.005"
0.02"
ALL DIMENSIONS IN INCHES (mm)
For global contact, visit:
www.powerconversion.com
technicalsupport@
powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
J2 (ON ‘G’ SUFFIX ONLY)
Pin 1
Safety Ground
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) connector type
Molex 26-60-4060 type.
DC (J3) mating connector type
Molex 09-50-3061 with Molex 2478 phosphor
bronze crimp terminals or equivalent.
Note: The input and output connectors are the same as those used on NFS40,
NFN40, NAL40, NAN40 and NLP40.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
J3
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
TRIPLE
V (A)
V (A)
V (A)
Return
Return
Return
V (B)
V (A)
V (A)
Return
Return
V (C)
V (B)
V (A)
V (A)
Return
Return
N/C
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
Similar pages