Lineage Power NSR060A0X43Z Naos raptor 60a: non-isolated power module Datasheet

Data Sheet
December 6, 2010
Naos Raptor 60A: Non-Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A Output Current
Features
RoHS Compliant
Applications

Distributed power architectures

Intermediate bus voltage applications

Telecommunications equipment

Servers and storage applications

Networking equipment

Compliant to RoHS EU Directive 2002/95/EC (Z
versions)

Compatible in a Pb-free or SnPb wave-soldering
environment (Z versions)


Wide input voltage range (5Vdc-13.8Vdc)

Tunable LoopTM to optimize dynamic output voltage
response

Fixed switching frequency

Output overcurrent protection (non-latching)

Over temperature protection

Over voltage protection – Hiccup Mode



Remote On/Off
Output voltage programmable from 0.6Vdc to
5.0Vdc via external resistor
Power Good Signal
Small size:
65.5 mm x 31.8 mm x 11.6 mm
(2.58 in. x 1.25 in. x 0.46 in.)



Wide operating temperature range (0°C to 70°C)
†
UL* 60950 Recognized, CSA C22.2 No. 60950-00
‡
rd
Certified, and VDE 0805 (EN60950-1 3 edition)
Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The Naos Raptor 60A SIP power modules are non-isolated dc-dc converters in an industry standard package that
can deliver up to 60A of output current with a full load efficiency of 92.1% at 3.3Vdc output voltage (VIN = 12Vdc).
These modules operate over a wide range of input voltage (VIN = 5Vdc-13.8Vdc) and provide a precisely regulated
output voltage from 0.6dc to 5.0Vdc, programmable via an external resistor. Features include remote On/Off,
adjustable output voltage, over current, over temperature and over voltage protection. A new feature, the Tunable
LoopTM, allows the user to optimize the dynamic response of the converter to match the load.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
Document No: DS06-129 ver. 1.09
PDF name: NSR060A0X_ds.pdf
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
Operating Ambient Temperature
All
VIN
-0.3
15
Vdc
All
TA
0
70
°C
All
Tstg
-55
125
°C
(see Thermal Considerations section)
Storage Temperature
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
VIN
5
12.0
13.8
Vdc
Maximum Input Current
All
IIN,max
40
Adc
(VIN= VIN, min to VIN, max, IO=IO, max VO,set = 3.3Vdc)
Input No Load Current
(VIN = 9Vdc, IO = 0, module ON)
VO,set = 0.6 Vdc
IIN,No load
36
(VIN = 12Vdc, IO = 0, module ON)
VO,set = 5.0Vdc
IIN,No load
86
mA
All
IIN,stand-by
1
mA
Inrush Transient
All
It
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN, min to
VIN, max, IO= IOmax ; See Test configuration section)
All
150
Input Ripple Rejection (120Hz)
All
50
Input Stand-by Current
mA
(VIN = 12Vdc, module disabled)
LINEAGE POWER
2
1
2
As
mAp-p
dB
2
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
% VO, set
Output Voltage Set-point
(VIN=IN, min, IO=IO, max, TA=25°C) Vo, SET ≥ 1.2Vdc
All
VO, set
–0.8
⎯
+0.8
Vo, SET < 1.2Vdc
All
VO, set
–10
⎯
+10
mV
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
All
VO, set
–1.1%
⎯
+1.1%
% VO, set
Adjustment Range
Selected by an external resistor
Output Regulation (for VO ≥ 2.5V)
All
VO
0.6
5.0
Vdc
0.3
% VO, set
Input range1 (5V – 9V); range2 (9V – 13.8V)
Line (Range1, range2)
⎯
All
Load (IO=IO, min to IO, max)
All
⎯
0.6
% VO, set
Line & Load
All
⎯
0.8
% VO, set
Line (Range1, range2)
All
⎯
9
mV
Load (IO=IO, min to IO, max)
All
⎯
12
mV
Line & Load
All
⎯
15
mV
Output Regulation (for VO < 2.5V)
Input range1 (5V – 9V); range2 (9V – 13.8V)
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max, Cout = 0μF)
Vo = 0.6V
⎯
30
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
Vo = 1V
⎯
30
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
Vo = 1.5V
⎯
40
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
Vo = 2.5V
⎯
40
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
Vo = 3.3V
⎯
60
mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth)
Vo = 5.0V
⎯
60
mVpk-pk
1000
μF
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance
1
TM
Without the Tunable Loop
All
CO, max
⎯
⎯
ESR ≥ 0.15 mΩ
All
CO, max
0
⎯
2000
μF
ESR ≥ 10 mΩ
All
CO, max
0
⎯
10000
μF
ESR ≥ 1 mΩ
With the Tunable Loop
TM
Output Current
All
Io
0
⎯
60
Adc
Output Current Limit Inception (Hiccup Mode )
All
IO, lim
103
130
180
% Io
Output Short-Circuit Current
All
IO, s/c
⎯
5
⎯
Adc
(VO≤250mV) ( Hiccup Mode )
Efficiency
VIN= VIN, nom, TA=25°C
IO=IO, max , VO= VO,set
Switching Frequency
1
VO,set = 0.6Vdc
η
74.4
%
VO,set = 1.2Vdc
η
85.0
%
VO,set = 1.8Vdc
η
88.6
%
VO,set = 2.5Vdc
η
91.0
%
VO,set = 3.3Vdc
η
92.1
%
VO,set = 5.0Vdc
η
93.5
%
All
fsw
⎯
500
⎯
kHz
TM
External capacitors may require using the new Tunable Loop feature to ensure that the module is stable as well as
TM
getting the best transient response. See the Tunable Loop section for details.
LINEAGE POWER
3
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
General Specifications
Parameter
Min
Calculated MTBF (VIN=12V, VO=1.5Vdc, IO=60°, TA=40°C) Per
Telcordia Issue 2, Method I Case 3
Typ
Max
Unit
2,808,442
⎯
Weight
Hours
⎯
22 (0.78)
g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to GND)
Logic High (On/Off pin open – Module ON)
Input High Current
All
IIH
0.5
⎯
3.3
mA
Input High Voltage
All
VIH
3.5
⎯
Vin,max
V
Logic Low (Module OFF)
Input Low Current
All
IIL
⎯
⎯
200
µA
Input Low Voltage
All
VIL
-0.3
⎯
1.2
V
0
0.4
V
2.4
5.25
V
Sink Current, PwGood = low
4
mA
Source Current, PwGood = high
2
mA
PwGood (Power Good)
Signal Interface Open Collector/Drain
PwGood = High = Power Good
PwGood = Low = Power Not Good
Logic level low voltage, Isink = 4 mA
Logic level high voltage, Isource = 2 mA
Turn-On Delay and Rise Times
(VIN=VIN, nom, IO=IO, max , VO to within ±1% of steady state)
Case 1: On/Off input is enabled and then
input power is applied (delay from instant at
which VIN = VIN, min until Vo = 10% of Vo, set)
All
Tdelay
3
msec
Case 2: Input power is applied for at least one second
and then the On/Off input is enabled (delay from instant
at which On/Off is enabled until Vo = 10% of Vo, set)
All
Tdelay
1.2
msec
Output voltage Rise time (time for Vo to rise from
10% of Vo, set to 90% of Vo, set)
All
Trise
3
msec
0.5
% VO, set
0.5
V
Output voltage overshoot
o
IO = IO, max; VIN, min – VIN, max, TA = 25 C
Remote Sense Range
All
Over Temperature Protection
All
⎯
Tref
⎯
135
ºC
(See Thermal Considerations section)
Input Undervoltage Lockout
Turn-on Threshold
All
4.5
4.8
Vdc
Turn-off Threshold
All
4.1
4.4
Vdc
125
130
VO, set, %
Overvoltage Protection (Hiccup Mode)
LINEAGE POWER
All
120
4
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves
The following figures provide typical characteristics for the Naos Raptor 60A module at 0.6Vout and at 25ºC.
90
70
OUTPUT CURRENT, Io (A)
EFFICIENCY, η (%)
85
80
Vin = 5V
75
Vin = 12V
70
Vin = 14V
65
0
10
20
30
40
50
0.5m/s
(100LFM)
20
10
30
35
40
45
50
55
60
65
OUTPUT VOLTAGE
VO (V) (100mV/div)
OUTPUT CURRENT,
I O (A) (10Adiv)
TIME, t (100μs /div)
VIN (V) (5V/div)
VO (V) (200mV/div)
Figure 4. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
INPUT VOLTAGE
VO (V) (200mV/div)
LINEAGE POWER
30
Figure 2. Derating Output Current versus Ambient
Temperature and Airflow.
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
ON/OFF VOLTAGE
VON/OFF (V) (200mV/div)
OUTPUT VOLTAGE
Figure 5. Typical Start-up Using On/Off Voltage (Io =
Io,max).
1m/s
(200LFM)
AMBIENT TEMPERATURE, TA C
Figure 1. Converter Efficiency versus Output Current.
TIME, t (1ms/div)
1.5m/s
(300LFM)
40
O
OUTPUT CURRENT, IO (A)
Figure 3. Typical output ripple and noise (VIN = 12V, Io =
Io,max).
50
25
60
TIME, t (1μs/div)
2m/s
(400LFM)
60
TIME, t (1ms/div)
Figure 6. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
5
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves (continued)
The following figures provide typical characteristics for the Naos Raptor 60A module at 1.2Vout and at 25ºC.
70
95
85
OUTPUT CURRENT, Io (A)
EFFICIENCY, η (%)
90
Vin = 5V
Vin = 12V
80
Vin = 14V
75
70
0
10
20
30
40
50
60
LINEAGE POWER
1m/s
(200LFM)
30
0.5m/s
(100LFM)
20
10
30
35
40
45
50
55
60
65
IO (A) (10Adiv)
OUTPUT CURRENT,
VO (V) (100mV/div)
Figure 8. Derating Output Current versus Ambient
Temperature and Airflow.
OUTPUT VOLTAGE
Figure 11. Typical Start-up Using On/Off Voltage (Io =
Io,max).
1.5m/s
(300LFM)
AMBIENT TEMPERATURE, TA C
TIME, t (100μs /div)
INPUT VOLTAGE
VIN (V) (5V/div)
VO (V) (500mV/div)
Figure 10. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
VON/OFF (V) (200mV/div)
ON/OFF VOLTAGE
OUTPUT VOLTAGE
VO (V) (500mV/div)
TIME, t (1ms/div)
40
O
Figure 7. Converter Efficiency versus Output Current.
Figure 9. Typical output ripple and noise (VIN = 12V, Io =
Io,max).
50
25
OUTPUT CURRENT, IO (A)
TIME, t (1μs/div)
2m/s
(400LFM)
60
TIME, t (1ms/div)
Figure 12. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
6
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves (continued)
The following figures provide typical characteristics for the Naos Raptor 60A module at 1.8Vout and at 25ºC.
95
OUTPUT CURRENT, Io (A)
70
EFFICIENCY, η (%)
90
Vin = 5V
Vin = 12V
85
Vin = 14V
80
75
0
10
20
30
40
50
0.5m/s
(100LFM)
20
10
30
35
40
45
50
55
60
65
OUTPUT VOLTAGE
VO (V) (200mV/div)
IO (A) (10Adiv)
OUTPUT CURRENT,
TIME, t (100μs /div)
VIN (V) (5V/div)
VO (V) (500mV/div)
Figure 16. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
INPUT VOLTAGE
VO (V) (500mV/div)
LINEAGE POWER
1m/s
(200LFM)
30
Figure 14. Derating Output Current versus Ambient
Temperature and Airflow.
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
ON/OFF VOLTAGE
VON/OFF (V) (200mV/div)
OUTPUT VOLTAGE
Figure 17. Typical Start-up Using On/Off Voltage (Io =
Io,max).
1.5m/s
(300LFM)
AMBIENT TEMPERATURE, TA C
Figure 13. Converter Efficiency versus Output Current.
TIME, t (1ms/div)
40
O
OUTPUT CURRENT, IO (A)
Figure 15. Typical output ripple and noise (VIN = 12V, Io
= Io,max).
50
25
60
TIME, t (1μs/div)
2m/s
(400LFM)
60
TIME, t (1ms/div)
Figure 18. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
7
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves (continued)
The following figures provide typical characteristics for the Naos Raptor 60A module at 2.5Vout and at 25ºC.
100
70
OUTPUT CURRENT, Io (A)
EFFICIENCY, η (%)
95
Vin = 5V
90
Vin = 12V
85
Vin = 14V
80
75
0
10
20
30
40
50
0.5m/s
(100LFM)
20
10
30
35
40
45
50
55
60
65
OUTPUT VOLTAGE
VO (V) (200mV/div)
IO (A) (10Adiv)
OUTPUT CURRENT,
TIME, t (100μs /div)
VIN (V) (5V/div)
VO (V) (1V/div)
Figure 22. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
INPUT VOLTAGE
VO (V) (1V/div)
LINEAGE POWER
1m/s
(200LFM)
Figure 20. Derating Output Current versus Ambient
Temperature and Airflow.
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
ON/OFF VOLTAGE
VON/OFF (V) (200mV/div)
OUTPUT VOLTAGE
Figure 23. Typical Start-up Using On/Off Voltage (Io =
Io,max).
1.5m/s
(300LFM)
30
AMBIENT TEMPERATURE, TA C
Figure 19. Converter Efficiency versus Output Current.
TIME, t (1ms/div)
40
O
OUTPUT CURRENT, IO (A)
Figure 21. Typical output ripple and noise (VIN = 12V, Io
= Io,max).
50
25
60
TIME, t (1μs/div)
2m/s
(400LFM)
60
TIME, t (1ms/div)
Figure 24. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
8
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves (continued)
The following figures provide typical characteristics for the Naos Raptor 60A module at 3.3Vout and at 25ºC.
70
100
OUTPUT CURRENT, Io (A)
EFFICIENCY, η (%)
95
90
Vin = 6V
Vin = 12V
Vin = 14V
85
80
75
0
10
20
30
40
50
60
LINEAGE POWER
1m/s
(200LFM)
20
0.5m/s
(100LFM)
10
30
35
40
45
50
55
60
65
IO (A) (10Adiv)
OUTPUT VOLTAGE
OUTPUT CURRENT,
VO (V) (200mV/div)
Figure 26. Derating Output Current versus Ambient
Temperature and Airflow.
TIME, t (100μs /div)
VIN (V) (5V/div)
VO (V) (1V/div)
Figure 28. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
INPUT VOLTAGE
VO (V) (1V/div)
Figure 29. Typical Start-up Using On/Off Voltage (Io =
Io,max).
1.5m/s
(300LFM)
30
AMBIENT TEMPERATURE, TA C
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
ON/OFF VOLTAGE
VON/OFF (V) (200mV/div)
OUTPUT VOLTAGE
TIME, t (1ms/div)
40
O
Figure 25. Converter Efficiency versus Output Current.
Figure 27. Typical output ripple and noise (VIN = 12V, Io
= Io,max).
50
25
OUTPUT CURRENT, IO (A)
TIME, t (1μs/div)
2m/s
(400LFM)
60
TIME, t (1ms/div)
Figure 30. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
9
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Characteristic Curves (continued)
The following figures provide typical characteristics for the Naos Raptor 60A module at 5Vout and at 25ºC.
70
100
90
Vin = 12V
Vin = 9V
OUTPUT CURRENT, Io (A)
EFFICIENCY, η (%)
95
Vin = 14V
85
80
75
0
10
20
30
40
50
60
LINEAGE POWER
30
1.5m/s
(300LFM)
1m/s
(200LFM)
20
0.5m/s
(100LFM)
10
30
35
40
45
50
55
60
65
IO (A) (10Adiv)
OUTPUT VOLTAGE
OUTPUT CURRENT,
VO (V) (200mV/div)
Figure 32. Derating Output Current versus Ambient
Temperature and Airflow.
TIME, t (100μs /div)
VIN (V) (5V/div)
VO (V) (2V/div)
Figure 34. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with VIN=12V.
INPUT VOLTAGE
VO (V) (1V/div)
Figure 35. Typical Start-up Using On/Off Voltage (Io =
Io,max).
40
AMBIENT TEMPERATURE, TA C
OUTPUT VOLTAGE
VO (V) (10mV/div)
OUTPUT VOLTAGE
ON/OFF VOLTAGE
VON/OFF (V) (200mV/div)
OUTPUT VOLTAGE
TIME, t (1ms/div)
50
O
Figure 31. Converter Efficiency versus Output Current.
Figure 33. Typical output ripple and noise (VIN = 12V, Io
= Io,max).
2m/s
(400LFM)
25
OUTPUT CURRENT, IO (A)
TIME, t (1μs/div)
60
TIME, t (1ms/div)
Figure 36. Typical Start-up Using Input Voltage (VIN =
12V, Io = Io,max).
10
70
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Test Configurations
Design Considerations
CURRENT PROBE
The Naos Raptor 60A module should be
connected to a low-impedance source. A highly
inductive source can affect the stability of the
module. An input capacitance must be placed
directly adjacent to the input pin of the module, to
minimize input ripple voltage and ensure module
stability.
To minimize input voltage ripple, low-ESR polymer
and ceramic capacitors are recommended at the input
of the module. Figure 40 shows the input ripple
voltage for various output voltages at 60A of load
current with 2x22 µF or 4x22 µF ceramic capacitors
and an input of 12V.
LTEST
VIN(+)
BATTERY
1μH
CIN
CS 1000μF
Electrolytic
2x100μF
Tantalum
E.S.R.<0.1Ω
@ 20°C 100kHz
COM
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 1μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 37. Input Reflected Ripple Current Test
Setup.
COPPER STRIP
VO (+)
RESISTIVE
LOAD
1uF
.
10uF
SCOPE
COM
GROUND PLANE
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 38. Output Ripple and Noise Test Setup.
Rdistribution
Rcontact
Rcontact
VIN(+)
Input Filtering
Rdistribution
250
Input Ripple Voltage (mVp-p)
TO OSCILLOSCOPE
2x22uF
200
4x22uF
150
100
50
0
0
1
2
3
4
5
Output Voltage (Vdc)
Figure 40. Input ripple voltage for various output
voltages with 2x22 µF or 4x22 µF ceramic
capacitors at the input (60A load). Input voltage is
12V.
VO
Output Filtering
VO
VIN
Rdistribution
RLOAD
Rcontact
Rcontact
COM
Rdistribution
COM
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 39. Output Voltage and Efficiency Test
Setup.
VO. IO
Efficiency
η =
LINEAGE POWER
VIN. IIN
x
100 %
The Naos Raptor 60A modules are designed for low
output ripple voltage and will meet the maximum
output ripple specification with no external capacitors.
However, additional output filtering may be required
by the system designer for a number of reasons.
First, there may be a need to further reduce the
output ripple and noise of the module. Second, the
dynamic response characteristics may need to be
customized to a particular load step change.
To reduce the output ripple and improve the dynamic
response to a step load change, additional
capacitance at the output can be used. Low ESR
ceramic and polymer are recommended to improve
the dynamic response of the module. For stable
operation of the module, limit the capacitance to less
than the maximum output capacitance as specified in
the electrical specification table. Optimal
performance of the module can be achieved by using
11
Data Sheet
December 6, 2010
TM
the Tunable Loop
data sheet.
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
feature described later in this
Remote On/Off
Safety Considerations
For safety agency approval the power module must
be installed in compliance with the spacing and
separation requirements of the end-use safety agency
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-103, and VDE 0850:2001-12 (EN60950-1) Licensed.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
An input fuse for the module is recommended. Due to
the wide input voltage and output voltage ranges of
the module, different fuse ratings are recommended
as shown in Table 1. These are suggested
“maximum” fuse ratings. However, for optimum circuit
protection, the fuse value should not be any larger
than required in the end application. As an option to
using a fuse, no fuse is required, if the module is
1. powered by a power source with current limit
protection set point less than the protection
device value listed in Table 1, and
2. the module is evaluated in the end-use
equipment.
Table 1.
Input
Voltage
(VDC)
10.1 to 14
6.51 to 10
5 to 6.5
Output Voltage (VDC)
0.59 to 1.3
25A
40A
40A
1.31 to 2.7
50A
70A
90A
Feature Descriptions
2.71 to 5.0
80A
100A
100A
The Naos Raptor 60A power modules feature a
remote On/Off pin with positive logic. If not using the
On/Off pin, leave the pin open (the module will be ON,
except for the -49 option modules where leaving the
pin open will cause the module to remain OFF). The
On/Off signal (VOn/Off) is referenced to ground.
During a Logic High on the On/Off pin, the module
remains ON. During Logic-Low, the module is turned
OFF.
MODULE
5V
2K
2K
100K
ENABLE
ON/OFF
2.2K
2.2K
47K
47K
GND
Figure 41. Remote On/Off Implementation. The
100K resistor is absent in the -49 option modules.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought
back into its specified range. The typical average
output current during hiccup is 10% of Io,max.
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shut down if the overtemperature threshold of 135ºC
is exceeded at the thermal reference point Tred. The
thermal shutdown is not intended as a guarantee that
the unit will survive temperatures beyond its rating.
Once the unit goes into thermal shutdown, it will then
wait to cool before attempting to restart.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, module operation is disabled. The module will
begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.
LINEAGE POWER
12
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Power Good
Table 2
The Naos Raptor 60A power modules provide a
Power Good Status signal that indicates whether or
not the power module is functioning properly.
PwGood is a power good signal implemented with an
open-collector output to indicate that the output
voltage is within the regulation limits of the power
module. The PwGood signal will be de-asserted to a
low state If any condition such as over-temperature,
over-current, or over-voltage occurs which would
result in the output voltage going out of range.
VO, set (V)
Rtrim (Ω)
0.6
1.0
1.2
1.5
1.8
2.5
3.3
5.0
Open
3000
2000
1333
1000
632
444
273
Output Voltage Programming
Monotonic Start-up and Shutdown
The output voltage of the Naos Raptor 60A module
can be programmed to any voltage from 0.6Vdc to
5.0Vdc by connecting a resistor between the Trim +
and Trim - pins of the module. Without an external
resistor between Trim + and Trim - pins, the output of
the module will be 0.6Vdc. To calculate the value of
the trim resistor, Rtrim for a desired output voltage,
use the following equation:
The Naos Raptor 60A modules have monotonic startup and shutdown behavior for any combination of
rated input voltage, output current and operating
temperature range.
Rtrim =
1.2
kΩ
(Vo − 0.6)
Rtrim is the external resistor in kΩ
Vo is the desired output voltage
Table 2 provides Rtrim values required for some
common output voltages.
By using a ±0.1% tolerance trim resistor with a TC of
±25ppm, a set point tolerance of ±0.8% can be
achieved as specified in the electrical specification.
The POL Programming Tool available at
www.lineagepower.com under the Design Tools
section, helps determine the required trim resistor
needed for a specific output voltage.
Note: Vin ≥ 180% of Vout at the module output pin.
V IN(+)
V O(+)
ON/OFF
TRIM+
Vout
LOAD
R trim
TRIM−
GND
Figure 42. Circuit configuration for programming
output voltage using an external resistor.
LINEAGE POWER
13
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
VOUT
SENSE+
Feature Descriptions (continued)
Tunable LoopTM
The Naos Raptor 60A modules have a new feature
that optimizes transient response of the module called
TM
Tunable Loop . External capacitors are usually
added to improve output voltage transient response
due to load current changes. Sensitive loads may
also require additional output capacitance to reduce
output ripple and noise. Adding external capacitance
however affects the voltage control loop of the
module, typically causing the loop to slow down with
sluggish response. Larger values of external
capacitance could also cause the module to become
unstable.
To use the additional external capacitors in an optimal
manner, the Tunable LoopTM feature allows the loop
to be tuned externally by connecting a series R-C
between the SENSE and TRIM pins of the module, as
shown in Fig. 43. This R-C allows the user to
externally adjust the voltage loop feedback
compensation of the module to match the filter
network connected to the output of the module.
Recommended values of RTUNE and CTUNE are given
in Tables 3 and 4. Table 3 lists recommended values
of RTUNE and CTUNE in order to meet 2% output
voltage deviation limits for some common output
voltages in the presence of a 30A to 60A step change
(50% of full load), with an input voltage of 12V. Table
4 shows the recommended values of RTUNE and CTUNE
for different values of ceramic output capacitors up to
1880 µF, again for an input voltage of 12V. The value
of RTUNE should never be lower than the values shown
in Tables 3 and 4. Please contact your Lineage Power
technical representative to obtain more details of this
feature as well as for guidelines on how to select the
right value of external R-C to tune the module for best
transient performance and stable operation for other
output capacitance values.
LINEAGE POWER
RTune
MODULE
CTune
TRIM+
RTrim
TRIMFigure. 43. Circuit diagram showing connection of
RTUME and CTUNE to tune the control loop of the
module.
Table 3. Recommended values of RTUNE and CTUNE
to obtain transient deviation of 2% of Vout for a
30A step load with Vin=12V.
Vout
5V
3.3V
2.5V
1.8V
1.2V
0.6V
2x47μF 6x47μF 2x47μF
+
+
+
8x330μF 13x330μF 31x330μF
Cext
2x330μF 3x330μF 5x330μF Polymer Polymer Polymer
Polymer Polymer Polymer
RTUNE
100
68
47
39
33
30
CTUNE
12nF
27nF
47nF
100nF
180nF
180nF
ΔV
100mV
66mV
50mV
36mV
24mV
12mV
Table 4. General recommended values of of RTUNE
and CTUNE for Vin=12V and various external
ceramic capacitor combinations.
Cext
RTUNE
2x47μF 4x47μF 10x47μF 20x47μF 40x47μF
100
75
CTUNE 2700pF 4700pF
47
33
30
12nF
22nF
27nF
14
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Thermal Considerations
Power modules operate in a variety of thermal
environments; however sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test setup is shown in Figure 44. The derating data applies
to airflow in either direction of the module’s axis.
The thermal reference points, Tref1 and Tref2 used in
the specifications are shown in Figure 45. For reliable
operation this temperatures should not exceed 120ºC.
The output power of the module should not exceed
the rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Heat Transfer via Convection
Wind Tunnel
50.8
[2.00]
PWBs
Power Module
76.2
[3.0]
7.24
[0.285]
Probe Location
for measuring
airflow and
ambient
temperature
Air
Flow
Figure 44. Thermal Test Set-up.
Figure 45. Temperature measurement locations
Tref1 and Tref2.
LINEAGE POWER
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered at different local ambient temperatures (TA)
for airflow conditions ranging from natural convection
and up to 2m/s (400 ft./min) are shown in the
Characteristics Curves section.
Post solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect
both the reliability of a power module and the
testability of the finished circuit-board assembly. For
guidance on appropriate soldering, cleaning and
drying procedures, refer to the Board Mounted Power
Modules: Soldering and Cleaning Application Note.
Through-Hole Lead-Free Soldering
Information
The RoHS-compliant through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant
components. They are designed to be processed
through single or dual wave soldering machines. The
pins have an RoHS-compliant finish that is compatible
with both Pb and Pb-free wave soldering processes.
A maximum preheat rate of 3°C/s is suggested. The
wave preheat process should be such that the
temperature of the power module board is kept below
210°C. For Pb solder, the recommended pot
temperature is 260°C, while the Pb-free solder pot is
270°C max. Not all RoHS-compliant through-hole
products can be processed with paste-through-hole
Pb or Pb-free reflow process. If additional information
is needed, please consult with your Lineage Power
representative for more details.
15
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Mechanical Outline
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
Pin 26
Pin 25
Pin 3
Pin 24
Pin 1
L = 2.85 ± 0.25 [ 0.112 ± 0.01]
L = 5.08 ± 0.25 [ 0.200 ± 0.01] 5 Option
Side View
Front View
Pinout
LINEAGE POWER
Pin
Function
Pin
Function
Pin
1
Trim +
9
On/Off
18
Function
Vout
2
No Pin
10
Sense -
19
GND
3
GND
11
Sense +
20
Vout
4
PwGood
12
Vin
21
GND
5
Trim -
13
Vin
22
Vout
6
Ishare
14
Vin
23
GND
7
GND
15
Vout
24
Vout
8
GND
16
Vout
25
GND
17
GND
26
GND
16
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Recommended Pad Layout
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
LINEAGE POWER
17
Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 5. Device Codes
Device Code
Input
Voltage Range
Output
Voltage
Output
Current
On/Off
Logic
Connector Type
Comcode
NSR060A0X43Z
5 – 13.8Vdc
0.6 – 5.0Vdc
60 A
Positive
SIP
CC109130936
NSR060A0X43-49Z*
5 – 13.8Vdc
0.6 – 5.0Vdc
60 A
Positive
SIP
CC109138236
NSR060A0X543-37Z*
5 – 13.8Vdc
0.6 – 5.0Vdc
60 A
Positive
SIP
CC109150942
Z refers to RoHS-compliant versions.
* Special codes, consult factory before ordering
Table 6. Device Options
Option
Suffix
Long Pins
5.08 mm ± 0.25 mm
[0.2 ± 0.010 in.]
5
Asia-Pacific Headquarters
Tel: +86.021.54279977*808
World Wide Headquarters
Lineage Power Corporation
601 Shiloh Road, Plano, TX 75074, USA
+1-888-LINEAGE(546-3243)
(Outside U.S.A.: +1-972-244-WATT(9288))
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49.89.878067-280
India Headquarters
Tel: +91.80.28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents.
© 2010 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved.
LINEAGE POWER
18
Document No: DS06-129 ver. 1.09
PDF name: NSR060A0X_ds.pdf
Similar pages