MBR2020FCT THRU MBR20100FCT omponents 20736 Marilla Street Chatsworth !"# $ % !"# Features • • • • • 20 Amp Schottky Barrier Rectifier 20 to 100 Volts High Surge Capacity Low Forward Voltage Drop High Current Capability, High Efficiency Marking : type number Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Maximum Ratings • • ITO-220AB Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C B L M MCC Catalog Number MBR2020FCT MBR2030FCT MBR2035FCT MBR2040FCT MBR2045FCT MBR2060FCT MBR2080FCT MBR20100FCT Maximum Recurrent Peak Reverse Voltage 20V 30V 35V 40V 45V 60V 80V 100V Maximum RMS Voltage 14V 21V 24.5V 28V 31.5V 42V 56V 70V C Maximum DC Blocking Voltage 20V 30V 35V 40V 45V 60V 80V 100V IF(AV) 20 A TA = 120°C IFSM 150A 8.3ms, half sine PIN 1 Maximum DC Reverse Current At Rated DC Blocking Voltage 2020FCT~2045FCT 2060FCT~20100FCT 2020FCT~2045FCT 2060FCT~20100FCT IR www.kersemi.com .70V .80V .85V .84V .95V .95V .72V .85V .85V 0.1mA 0.15mA 50mA 150mA IFM = 10A; TA =25°C IFM = 20A; TA =25°C IFM = 20A; TA =125°C TA = 25°C TA = 125°C 2 3 E F O I G J N H H PIN 1 PIN 2 PIN 3 VF A K Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage 2020FCT-2045FCT 2060FCT 2080FCT-20100FCT 2020FCT-2045FCT 2060FCT 2080FCT-20100FCT 2020FCT-2045FCT 2060FCT 2080FCT-20100FCT D A B C D E F G H I J K L M N O INCHES .583 .606 --.406 .100 .112 .248 .272 --.161 --.071 .512 .543 .100 --.035 --.032 .118 .134 --.189 --.130 .098 .114 --.055 MM 14.80 --2.55 6.30 ----13.00 15.40 10.30 2.85 6.90 4.10 1.80 13.80 2.55 ----3.00 ----2.50 --- 0.90 0.80 3.40 4.80 3.30 2.90 1.40 MBR2020FCT thru MBR20100FCT Figure 1 Typical Forward Characteristics 100 60 Figure 2 Typical Reverse Characteristics 2060FCT 50 40 MBR2020FCT-MBR2045FCT 10 T A = 125 º C 20 1 2020FCT-2045FCT MBR2060FCT-MBR20100FCT mA 10 6 TA = 75º C 0.1 4 MBR2020FCT-MBR2045FCT 0.01 2080FCT-20100FCT 2 TA = 25º C 25°C 0.001 Amps 1 .6 MBR2060FCT-MBR20100FCT 0 20 40 60 80 Volts [%] 100 120 140 Instantaneous Reverse Leakage Current - mAmpere Percent Of Rated Peak Reverse Voltage - Volts% .4 .2 .1 .06 .04 .02 .01 .2 .3 .4 .5 .6 .7 .8 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 20 150 18 125 16 100 75 14 Amps Amps 50 12 25 10 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 100 125 150 °C 1 2 4 6 8 10 20 40 60 80 100 Cycles Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Average Forward Rectified Current - Amperesversus Ambient Temperature - °C www.kersemi.com