Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] The ACTF480-4/479.5/TO39 is a two channel IF filter for DSB receivers with constant group delay. 1.Package Dimension (TO-39) 2. Pin Configuration 1 Input / Output 2 Output 2 / Input 2 3 Output 1 / Input 1 4 Ground Dimensions Data (Unit: mm) A 9.35±0.10 B 5.08±0.10 C 3.40±0.10 D 3.00±0.20 E 4-Φ0.45±0.20 3.Equivalent LC Model 4.Performance 4-1.Maximum Ratings Rating Value Units AC Voltage Between Any Two Pins V PP 5 V DC Voltage Between Any Two Pins Storage temperature range V DC T stg 0 V -40 to +85 °C Operable temperature range TA -25 to +85 °C In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1 C1 Date : SEPT 04 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 4-2.Electronic Characteristics TA = 25 °C Reference temperature: Terminating source impedance: ZS = 50 Ω Terminating load impedance: ZL = 50 Ω 0.25MHz Group delay aperture: Characteristics of Channel 1 Characteristic Centre Frequency fc Insertion attenuation 479.50 MHz (Reference level for the following data) Pass bandwidth αrel≤3dB B3dB Typ. Max. Units 478.50 479.50 480.50 MHz -- 21.8 24.0 dB -- 15.0 -- MHz --34.0 34.0 3.1 3.0 45.0 44.0 5.0 5.0 --- dB dB dB dB 40.0 46.0 -- dB αrel Relative attenuation Lower sidelobe Upper sidelobe α Min. 472.00 MHz 487.00 MHz 430.00 ….458.00 MHz 501.00 … 530.00 MHz Reflected wave signal suppression 0.15s … 2.0μs after main pulse Amplitude ripple (p-p) 475.00 … 484.00 MHz Δα -- 0.6 1.2 dB Group delay ripple (p-p) 472.00 … 487.00 MHz Δτ -- 10 15 ns -- -86 -- ppm/K Temperature coefficient of frequency TCf In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1 C1 Date : SEPT 04 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] Characteristics of Channel 2 Characteristic Centre Frequency fc Insertion attenuation 479.50 MHz (Reference level for the following data) α αrel≤3dB B3dB Pass bandwidth Typ. Max. Units 478.50 479.50 480.50 MHz -- 22.0 24.0 dB -- 27.0 -- MHz --34.0 34.0 3.1 2.7 41.5 41.5 5.0 5.0 --- dB dB dB dB 40.0 44.0 -- dB αrel Relative attenuation Lower sidelobe Upper sidelobe Min. 466.00 MHz 493.00 MHz 430.00 ….456.00 MHz 503.00 … 530.00 MHz Reflected wave signal suppression 0.15μs … 3.0μs after main pulse Amplitude ripple (p-p) 475.00 … 484.00 MHz Δα -- 0.6 1.2 dB Group delay ripple (p-p) 466.00 … 493.00 MHz Δτ -- 8 15 ns -- -86 -- ppm/K Temperature coefficient of frequency TCf In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1 C1 Date : SEPT 04 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 5.Typical Frequency Response In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1 C1 Date : SEPT 04 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling! 1. 2. 3. 4. 5. 6. The frequency f C is defined as the midpoint between the 3dB frequencies. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality. Unless noted otherwise, specifications apply over the entire specified operating temperature range. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies. In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered - Registration number 6830/2 For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1 C1 Date : SEPT 04