OPTREX DMF5005NF Lcd module technical specification Datasheet

First Edition
Jul 24, 2001
OPTREX
LCD Module Technical Specification
Final Revision
******
Type No.
DMF5005NF-SEW-BBE-CQ
Approved by (Production Div.)
Checked by (Quality Assurance Div.)
Checked by (Design Engineering Div.)
Prepared by (Production Div.)
Table of Contents
1. General Specifications .................................................................................................................................. 2
2. Electrical Specifications ............................................................................................................................... 3
3. Optical Specifications ................................................................................................................................... 7
4. I/O Terminal ...................................................................................................................................................... 9
5. Test ................................................................................................................................................................... 11
6. Appearance Standards ............................................................................................................................... 12
7. Code System of Production Lot ............................................................................................................... 15
8. Type Number.................................................................................................................................................. 15
9. Applying Precautions .................................................................................................................................. 15
10. Precautions Relating Product Handling................................................................................................ 16
11. Warranty ........................................................................................................................................................ 17
Revision History
Rev.
Date
Page
Comment
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 1/17
1. General Specifications
Operating Temp.
:
min. 0°C ~max. 50°C
Storage Temp.
:
min. -20°C ~max. 60°C
Dot Pixels
:
240 (W)
Dot Size
:
0.49 (W)
×
0.49 (H) mm
Dot Pitch
:
0.53 (W)
×
0.53 (H) mm
Viewing Area
:
132.0 (W)
×
39.0 (H) mm
Outline Dimensions
:
180.0 (W)
×
65.0 (H)
Weight
:
170g max.
LCD Type
:
NSD-7446
( F-STN / Black &White-mode / Transflective )
Viewing Angle
:
6:00
Control LSI
:
T6963C-0101 (Produced by TOSHIBA)
Data Transfer
:
8-bit parallel data transfer
Backlight
:
Electro Luminescence (EL) / White
Drawings
:
Dimensional Outline
×
64 (H) dots
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
×
12.0 max. (D) mm
UE-31806B
OPTREX CORPORATION
Page 2/17
2. Electrical Specifications
2.1. Absolute Maximum Ratings
VSS=0V
Parameter
Symbol
Conditions
Min.
Max.
Units
Supply Voltage
VCC -V SS
-
-0.3
7.0
V
VCC -V EE
-
0
28.0
V
VI
-
-0.3
VCC +0.3
V
(Logic)
Supply Voltage
(LCD Drive)
Input Voltage
2.2. DC Characteristics
Ta=25°C, VSS=0V
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Supply Voltage
VCC -V SS
-
4.5
-
5.5
V
(Logic)
Supply Voltage
VCC -V EE
Shown in 3.1
V
(LCD Drive)
High Level
VIH
VCC =5.0V±10%
VCC -2.2
-
VCC
V
VIL
VCC =5.0V±10%
0
-
0.8
V
VOH
IOH =-0.75mA
VCC -0.3
-
VCC
V
VOL
IOL=0.75mA
0
-
0.3
V
ICC
VCC -V SS=5.0V
-
12.5
20.0
mA
IEE
VCC -V EE=13.3V
-
3.0
10.0
mA
Input Voltage
Low Level
Input Voltage
High Level
Output Voltage
Low Level
Output Voltage
Supply Current
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 3/17
2.3. AC Characteristics
VCC =5.0V±10%
Parameter
C/D Setup Time
C/D Hold Time
CE, RD, WR Pulse Width
Data Setup Time
Data Hold Time
Access Time
Output Hold Time
Symbol
Min.
Max.
Units
tCDS
tCDH
tCE, tRD, tWR
tDS
tDH
tACC
tOH
100
-
ns
10
-
ns
80
-
ns
80
-
ns
40
-
ns
-
150
ns
10
50
ns
C/D
tCDS
tCDH
CE
tCE, tRD, tWR
RD, WR
tDS
tDH
D0∼ D7
(WRITE)
tACC
tOH
D0∼ D7
(READ)
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 4/17
2.4. Power Supply ON/OFF Sequence
2.4.1. ON Sequence
SIGNAL
LEVEL
VCC
VCC
VSS
0≤ t
SIGNAL
(Without RESET Signal)
VCC
VSS
0≤ t
VCC
VEE
VSS
VEE
2.4.2. OFF Sequence
LEVEL
SIGNAL
VCC
VSS
VCC
0≤ t
VCC
VSS
SIGNAL
0 ≤t
(Without RESET Signal)
VCC
VSS
VEE
VEE
2.4.3. Reset Sequence
SIGNAL
LEVEL
H Level
RESET
T>250 µs
T≥0
L Level
T ≥10 ms
VCC
VCC
T≥50ms
T ≥0
T ≥50ms
T≥0
VEE
VSS
VCC
VEE
Power On
Reset
Reset Cancellation
Power Off
Please maintain the above sequence when turning on and off the power supply of the
module.
If VEE is supplied to the module while internal alternate signal for LCD driving (M) is
unstable or RESET is active, DC component will be supplied to the LCD panel. This may
cause damage to the LCD module.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 5/17
2.5. Lighting Specifications
2.5.1. Absolute Maximum Rating
Ta=25°C
Parameter
Conditions
Min.
Typ.
Max.
Units
-
-
-
200
Vrms
AC100Vrms
-
-
1500
Hz
Input Voltage
Input Frequency
2.5.2. Operating Characteristics
Ta=25°C
Parameter
Conditions
Min.
Typ.
Max.
Units
Input Voltage
-
-
140
-
Vrms
Input Frequency
-
-
800
-
Hz
Current
AC140Vrms, 800Hz
-
14.2
18.1
mA
Luminance of
AC140Vrms, 800Hz
150
200
-
cd/m2
AC140Vrms, 800Hz
540
-
-
hrs
Backlight Surface
Life
Ta=20°C, 60%RH
Recommended Inverter : NS-106 ( DC 5.0V±10%, Produced by NEC )
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 6/17
3. Optical Specifications
3.1. LCD Driving Voltage
Parameter
Symbol
Recommended
LCD Driving Voltage
VCC -V EE
Note 1
Note 1 :
Conditions
Min.
Typ.
Max.
Units
Ta= 0°C
-
-
15.6
V
Ta=25°C
12.4
13.3
14.2
V
Ta=50°C
11.2
-
-
V
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast
ratio and response time are not guaranteed over the entire range.
3.2. Optical Characteristics
Ta=25°C, 1/64 Duty, 1/9 Bias, VD =13.3V (Note 4), θ= 0°, φ= - °
Parameter
Contrast Ratio
Symbol
Conditions
Min.
Typ.
Max.
CR
θ= 0°, φ= - °
-
7
-
Note 1
Viewing Angle
Response
Time
Units
Shown in 3.3
Rise Note 2
TON
-
-
70
140
ms
Decay Note 3
TOFF
-
-
330
500
ms
Note 1 :Contrast ratio is definded as follows.
CR = LOFF / LON
LON : Luminance of the ON segments
LOFF : Luminance of the OFF segments
Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when
ON signal is applied.
Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when
OFF signal is applied.
Note 4 :Definition of Driving Voltage VD
Assuming that the typical driving waveforms shown below are applied to the LCD Panel
at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is
definded as follows.
VD = (Vth1+Vth2) / 2
Vth1 : The voltage VO-P that should provide 50% of the saturation level in the luminance
at the segment which the ON signal is applied to.
Vth2 : The voltage VO-P that should provide 50% of the saturation level in the luminance
at the segment which the OFF signal is applied to.
VO-P
( B-2 )× V O-P / B
1 / ( f F ×A )
<ON SIGNAL>
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
1
/ fF
<OFF SIGNAL>
OPTREX CORPORATION
Page 7/17
3.3. Definition of Viewing Angle and Optimum Viewing Area
*Point • shows the point where contrast ratio is measured. : θ= 0°, φ= -°
*Driving condition : 1/64 Duty, 1/9 Bias, VD =13.3V, fF =70Hz
90°
45°
135°
θ
φ
180°
10 20 30 40 50
90°
( φ = 0°)
θ
φ
180°
225°
0°
315°
270°
270°
*Area
shows typ. CR≥2
3.4. System Block Diagram
Temperature Chamber
Rotation Table ( θ,φ )
Photometer
#1980A WB
φ
LCD
Optical Fiber
θ
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 8/17
4. I/O Terminal
4.1. Pin Assignment
No.
Symbol
Level
Function
1.
FG
-
Frame Ground
2.
VSS
-
Power Supply (0V, GND)
3.
VCC
-
Power Supply for Logic
4.
VEE
-
Power Supply for LCD Drive
5.
WR
H/L
Write Signal L : Active
6.
RD
H/L
Read Signal L : Active
7.
CE
H/L
Chip Enable Signal L : Active
8.
C/D
H/L
Write Mode H : Command Write L : Data Write
Read Mode H : Status Read L : Data Read
9.
NC
-
Non-connection
10.
RESET
H/L
Reset Signal L : Reset
11.
D0
H/L
Display Data
12.
D1
H/L
Display Data
13.
D2
H/L
Display Data
14.
D3
H/L
Display Data
15.
D4
H/L
Display Data
16.
D5
H/L
Display Data
17.
D6
H/L
Display Data
18.
D7
H/L
Display Data
19.
FS
H/L
Font Switch H : 6×8 dots L : 8×8 dots
20.
NC
-
Non-connection
21.
EL
-
Power Supply for EL
22.
EL
-
Power Supply for EL
4.2. Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the
tolerance of the driving voltage and its temperature dependence.
VCC
VEE
VCC (+Voltage)
Tr
R1
VR
MODULE
R2
VEE (-Voltage)
VSS
VSS (0V)
R1+R2+VR=10~ 20KΩ
Tr=2SA1202 or equivalent
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 9/17
4.3. Block Diagram
8
D0~D7
64
Row Driver
T6961B × 1
or equivalent
WR
RD
240 × 64 dots
3
5
Control LSI
LCDP
240
CE
4
T6963C
Column Driver
T6A39 × 3
or equivalent
C/D
RESET
FS
13
X-tal
8
64K S-RAM
VCC
VSS
Bias Circuit
To LSI
J
FG
VEE
EL
EL Backlight
EL
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 10/17
5. Test
No change on display and in operation under the following test condition.
Conditions:
No.
Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C
Humidity : 65±5%RH
tests will be not conducted under functioning state.
Parameter
Conditions
Notes
1
High Temperature Operating
50°C±2°C, 96hrs (operation state)
2
Low Temperature Operating
0°C±2°C, 96hrs (operation state)
1
3
High Temperature Storage
60°C±2°C, 96hrs
2
4
Low Temperature Storage
-20°C±2°C, 96hrs
1,2
5
Damp Proof Test
40°C±2°C,90~95%RH, 96hrs
1,2
6
Vibration Test
Total fixed amplitude : 1.5mm
3
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm high on
the concrete surface in packing state.
Dropping method corner dropping
F
E
G
B
D
C
A
60cm
A corner : once
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
Concrete Surface
Note 1 : No dew condensation to be observed.
Note 2 :
The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after removed from the test chamber.
Note 3 : Vibration test will be conducted to the product itself without putting it in a
container.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 11/17
6. Appearance Standards
6.1. Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45°against perpendicular line.
45°
6.2. Definition of applicable Zones
A Zone
Bezel Flame
B Zone
C Zone
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 12/17
6.3. Standards
No.
1
Parameter
Black and
Criteria
(1) Round Shape
White Spots,
Foreign Substances
Zone
Acceptable Number
Dimension (mm)
A
B
C
D ≤ 0.1
*
*
*
0.1 < D ≤ 0.2
3
5
*
0.2 < D ≤ 0.25
2
3
*
0.25< D ≤ 0.3
0
1
*
0.3 < D
0
0
*
D = ( Long + Short ) / 2
* : Disregard
(2) Line Shape
Zone
X (mm)
Acceptable Number
Y (mm)
A
B
C
-
0.03 ≥ W
*
*
*
2.0 ≥ L
0.05 ≥ W
3
3
*
1.0 ≥ L
0.1 ≥ W
3
3
*
-
0.1 < W
X : Length Y : Width
In the same way (1)
* : Disregard
Total defects shall not exceed 5.
2
Air Bubbles
(between glass
& polarizer)
Zone
Dimension (mm)
Acceptable Number
A
B
C
D ≤ 0.3
*
*
*
0.3 < D ≤ 0.4
3
*
*
0.4 < D ≤ 0.6
2
3
*
0.6 < D
0
0
*
* : Disregard
Total defects shall not exceed 3.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 13/17
No.
3
Parameter
The Shape of Dot
Criteria
(1) Dot Shape (with Dent)
0.15 ≥
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 2 ≤ 0.2mm
(Less than 0.1mm is no counted.)
(4) Deformation
(X+Y) / 2 ≤ 0.2mm
Y
X
Total acceptable number : 1/dot, 5/cell
(Defect number of (4) : 1pc.)
4
Polarizer Scratches
Not to be conspicuous defects.
5
Polarizer Dirts
If the stains are removed easily from LCDP surface, the module is not
defective.
6
7
Complex Foreign
Black spots, line shaped foreign substances or air bubbles between
Substance Defects
glass & polarizer should be 5pcs maximum in total.
Distance between
D ≤ 0.2 : 20mm or more
Different Foreign
0.2 < D : 40mm or more
Substance Defects
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 14/17
7. Code System of Production Lot
The production lot of module is specified as follows.
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Production Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8. Type Number
The type number of module is specified on the back of module as follows.
DMF5005NF-SEW-BBE-CQ
Stamp or Seal
9. Applying Precautions
Please contact us when questions and/or new problems not specified in this specificationsarise.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 15/17
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
1. The liquid crystal display device panel used in the liquid crystal display module is made of plate
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.
2. The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
1. When working with the module, be sure to ground your body and any electrical equipment you may
be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work
tables against the hazards of electrical shock.
2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other
conductivity-treated fibers.
3. Slowly and carefully remove the protective film from the LCD module, since this operation can
generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
1. Protect the modules from high temperature and humidity.
2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
3. Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the
module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module.
Should hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conductivity is not guaranteed for models that use metal holders where solder connections between
the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to
assure conductivity.
7) For models which use CFL:
1. High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.
3.The use of CFLs for extended periods of time at low temperatures will significantly shorten their
service life.
8) For models which use touch panels:
1.Do not stack up modules since they can be damaged by components on neighboring
modules.
2.Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
1.The mechanical strength of the product is low since the IC chip faces out unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
2.Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical
damage, avoid installation configurations in which the rear of the IC chip runs the risk of making
any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
1.In order to maintain reliability, do not touch or hold by the connector area.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 16/17
2.Avoid any bending, pulling, or other excessive force, which can result in broken
connections.
11. Warranty
This product has been manufactured to your company’s specifications as a part for use in your
company’s general electronic products. It is guaranteed to perform according to delivery specifications.
For any other use apart from general electronic equipment, we cannot take responsibility if the product
is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security
systems, or any other applications in which there is a direct risk to human life and where extremely
high levels of reliability are required. If the product is to be used in any of the above applications, we
will need to enter into a separate product liability agreement.
1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of
the product (including disassembly and reassembly), after product delivery.
2. We cannot accept responsibility for any defect, which may arise after the application of strong
external force to the product.
3. We cannot accept responsibility for any defect, which may arise due to the application of static
electricity after the product has passed your company’s acceptance inspection procedures.
4. When the product is in CFL models, CFL service life and brightness will vary according to the
performance of the inverter used, leaks, etc. We cannot accept responsibility for product
performance, reliability, or defect, which may arise.
5. We cannot accept responsibility for intellectual property of a third party, which may arise through
the application of our product to your assembly with exception to those issues relating directly to
the structure or method of manufacturing of our product.
6. Optrex will not be held responsible for any quality guarantee issue for defect products judged as
Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex
America, Optrex Europe, Display LC delivery which ever comes later.
DMF5005NF-SEW-BBE-CQ (CQ) No. 2001-0149
OPTREX CORPORATION
Page 17/17