ACDC 40 Watts ECP Series xppower.com • Low Profile Design • Ultra Compact Size from 3” x 2” x 0.9” • IT & Medical Approvals • Single, Dual and Triple Output • <0.3 W No Load Input Power • Peak Load Capability • 3 Year Warranty Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor No Load Input Power Earth Leakage Current Input Protection General • • • • • • • • 85-264 VAC 47-63 Hz 0.85 A max at 115 VAC 65 A max at 230 VAC EN61000-3-2, Class A <0.3 W <250 µA at 264 VAC, 60 Hz Internal T2 A/250 V fuse in line and neutral Output • See table • Single output: ±1% at 60% load, Multiple output: ±1% on V1, ±5% on V2 & V3 at 60% load Minimum Load • 10% minimum load required on V1 & V2 of multi output versions Start Up Delay • 1.3 s max Start Up Rise Time • 15 ms typical Hold Up Time • 10 ms min at full load at 115 VAC Line Regulation • ±0.5% max Load Regulation • V1 & V3: ±2%, V2: ±4% (see note 3) Cross Regulation • V2: 5%, 10-100% load change on V1 (see note 4) Transient Response • 4% max deviation, recovering to less than 1% within 500 µs for 50% step load change at 1 A/µs Ripple & Noise • 1% pk-pk, measured with 20 MHz bandwidth Overvoltage Protection • 110-140% of nominal output voltage on V1 only, recycle input to reset Overload Protection • Single output: 140-160% of nominal power Multiple output: 120-150% of nominal power on V1 and V2 only Short Circuit Protection • Trip and restart (hiccup mode) Temperature • ±0.02%/°C max Coefficient Output Voltage Initial Set Accuracy Efficiency Isolation Switching Frequency MTBF • See tables • 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 40-130 kHz variable • >400 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -10 °C to +70 °C, derate from 100% load at 50 °C to 50% load at 70 °C Cooling • Natural convection Operating Humidity • 5% to 95% RH, non condensing Storage Temperature • -40 °C to +85 °C Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity • • • • Radiated Immunity EFT / Burst Surge • • • Conducted Immunity Dips & Interruptions • • Safety Approvals • EN55022, level B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, ±4 kV indirect contact, Perf Criteria A EN61000-4-3, level 2, Perf Criteria A EN61000-4-4, level 3 Perf Criteria A EN61000-4-5, installation class 3, Perf Criteria A EN61000-4-6, level 3, Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60950-1, cUL60950, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1 Output Power 30 40 40 40 40 40 40 40 40 40 40 40 40 40 W W W W W W W W W W W W W W Voltage 5.0 VDC 12.0 VDC 15.0 VDC 18.0 VDC 24.0 VDC 30.0 VDC 48.0 VDC +5.0 VDC +5.0 VDC +5.0 VDC +5.0 VDC +5.0 VDC +5.0 VDC +5.0 VDC Output 1 Current 6.00 A 3.34 A 2.67 A 2.22 A 1.67 A 1.34 A 0.84 A 5.00 A 5.00 A 5.00 A 5.00 A 5.00 A 5.00 A 5.00 A Peak(1) 7.80 A 4.34 A 3.47 A 2.89 A 2.17 A 1.74 A 1.09 A 7.80 A 7.80 A 7.80 A 7.80 A 7.80 A 7.80 A 7.80 A Voltage +12.0 +15.0 +24.0 +12.0 +15.0 +24.0 +24.0 VDC VDC VDC VDC VDC VDC VDC Output 2 Current 2.0 1.5 1.0 2.0 1.5 1.0 1.0 A A A A A A A Output 3 Voltage Current Peak(1) 2.60 1.95 1.30 2.60 1.95 1.30 1.30 A A A A A A A -12.0 VDC -15.0 VDC +12.0 VDC -12.0 VDC 0.5 0.5 0.5 0.5 Efficiency(2) Model Number 82% 89% 89% 90% 90% 91% 92% 89% 90% 90% 89% 90% 90% 90% ECP40US05 ECP40US12 ECP40US15 ECP40US18 ECP40US24 ECP40US30 ECP40US48 ECP40UD01 ECP40UD02 ECP40UD03 ECP40UT01 ECP40UT02 ECP40UT03 ECP40UT04 A A A A Notes 1. 2. 3. 4. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. Typical efficiency at 230 VAC and full load at 25 °C. For multiple output units, load regulation is given for load change of 10% to 100% with other outputs set to 60% adjustment load. When V2 load is 15-100% Mechanical Details ECP40USXX ECP40UDXX / ECP40UTXX 3.00 (76.2) 3.50 (88.9) 2.75 (69.8) 3.25 (82.6) CN2 1 2.00 (50.8) 4 CN1 3 0.79 (19.0) 0.91 (23.0) Input Connector CN1 Pin 1 Neutral Pin 2 Not Fitted Pin 3 Line CN1 mates with JST housing VHR-3N and JST Series SVH-21T-P1.1 crimp terminals. 1.75 (44.5) 1.75 (44.5) 0.12 (3.2) 1 0.134 (Ø 3.4) CN2 1 2.0 (50.8) CN1 3 0.134 (Ø 3.4) 0.12 (3.2) 0.06 (1.6) 0.09 (2.4) Output Connector CN2 Pin 1 + Vout Pin 2 + Vout Pin 3 - Vout Pin 4 - Vout CN2 mates with JST housing VHR-4N and JST Series SVH-21T-P1.1 crimp terminals. Mounting holes marked with must be connected to safety earth 6 1 Mounting holes need to be isolated from ground 0.12 (3.2) 0.12 (3.2) 0.86 (22.0) 0.06 (1.6) 0.09 (2.4) Input Connector CN1 Pin 1 Neutral Pin 2 Not Fitted Pin 3 Line CN1 mates with JST housing VHR-3N and JST Series SVH-21T-P1.1 crimp terminals. Output Connector CN2 Pin 1 V2 Pin 2 V1 Pin 3 V1 Pin 4 RTN Pin 5 RTN Pin 6 V3 CN2 mates with JST housing VHR-6N and JST Series SVH-21T-P1.1 crimp terminals. Mounting holes marked with must be connected to safety earth Notes 1. All dimensions are in inches (mm). 2. Weight: ECP40USXX: 0.18 lbs (80 g) approx, ECP40UD/UTXX: 0.24 lbs (110 g) 19-Feb-13 ACDC ECP40 Models and Ratings