Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Earth Leakage Current
Input Protection
General
•
•
•
•
•
•
•
•
85-264 VAC
47-63 Hz
0.85 A max at 115 VAC
65 A max at 230 VAC
EN61000-3-2, Class A
<0.3 W
<250 µA at 264 VAC, 60 Hz
Internal T2 A/250 V fuse in line and neutral
Output
• See table
• Single output: ±1% at 60% load,
Multiple output: ±1% on V1, ±5% on V2
& V3 at 60% load
Minimum Load
• 10% minimum load required on V1 & V2
of multi output versions
Start Up Delay
• 1.3 s max
Start Up Rise Time
• 15 ms typical
Hold Up Time
• 10 ms min at full load at 115 VAC
Line Regulation
• ±0.5% max
Load Regulation
• V1 & V3: ±2%, V2: ±4% (see note 3)
Cross Regulation
• V2: 5%, 10-100% load change on V1
(see note 4)
Transient Response
• 4% max deviation, recovering to less than
1% within 500 µs for 50% step load
change at 1 A/µs
Ripple & Noise
• 1% pk-pk, measured with 20 MHz
bandwidth
Overvoltage Protection • 110-140% of nominal output voltage
on V1 only, recycle input to reset
Overload Protection
• Single output: 140-160% of nominal power
Multiple output: 120-150% of nominal power
on V1 and V2 only
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
• ±0.02%/°C max
Coefficient
Output Voltage
Initial Set Accuracy
Efficiency
Isolation
Switching Frequency
MTBF
• See tables
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 40-130 kHz variable
• >400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5% to 95% RH, non condensing
Storage Temperature • -40 °C to +85 °C
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
•
•
•
•
Radiated Immunity
EFT / Burst
Surge
•
•
•
Conducted Immunity
Dips & Interruptions
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4 kV indirect contact,
Perf Criteria A
EN61000-4-3, level 2, Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria A
EN61000-4-6, level 3, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60950-1, cUL60950, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
Output
Power
30
40
40
40
40
40
40
40
40
40
40
40
40
40
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Voltage
5.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
30.0 VDC
48.0 VDC
+5.0 VDC
+5.0 VDC
+5.0 VDC
+5.0 VDC
+5.0 VDC
+5.0 VDC
+5.0 VDC
Output 1
Current
6.00 A
3.34 A
2.67 A
2.22 A
1.67 A
1.34 A
0.84 A
5.00 A
5.00 A
5.00 A
5.00 A
5.00 A
5.00 A
5.00 A
Peak(1)
7.80 A
4.34 A
3.47 A
2.89 A
2.17 A
1.74 A
1.09 A
7.80 A
7.80 A
7.80 A
7.80 A
7.80 A
7.80 A
7.80 A
Voltage
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+24.0
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Output 2
Current
2.0
1.5
1.0
2.0
1.5
1.0
1.0
A
A
A
A
A
A
A
Output 3
Voltage
Current
Peak(1)
2.60
1.95
1.30
2.60
1.95
1.30
1.30
A
A
A
A
A
A
A
-12.0 VDC
-15.0 VDC
+12.0 VDC
-12.0 VDC
0.5
0.5
0.5
0.5
Efficiency(2)
Model
Number
82%
89%
89%
90%
90%
91%
92%
89%
90%
90%
89%
90%
90%
90%
ECP40US05
ECP40US12
ECP40US15
ECP40US18
ECP40US24
ECP40US30
ECP40US48
ECP40UD01
ECP40UD02
ECP40UD03
ECP40UT01
ECP40UT02
ECP40UT03
ECP40UT04
A
A
A
A
Notes
1.
2.
3.
4.
Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
Typical efficiency at 230 VAC and full load at 25 °C.
For multiple output units, load regulation is given for load change of 10% to 100% with other outputs set to 60% adjustment load.
When V2 load is 15-100%
Mechanical Details
ECP40USXX
ECP40UDXX / ECP40UTXX
3.00 (76.2)
3.50 (88.9)
2.75 (69.8)
3.25 (82.6)
CN2
1
2.00
(50.8)
4
CN1
3
0.79
(19.0)
0.91 (23.0)
Input Connector CN1
Pin 1
Neutral
Pin 2
Not Fitted
Pin 3
Line
CN1 mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals.
1.75
(44.5)
1.75
(44.5)
0.12
(3.2)
1
0.134 (Ø 3.4)
CN2
1
2.0
(50.8)
CN1
3
0.134 (Ø 3.4)
0.12
(3.2)
0.06
(1.6)
0.09 (2.4)
Output Connector CN2
Pin 1
+ Vout
Pin 2
+ Vout
Pin 3
- Vout
Pin 4
- Vout
CN2 mates with JST housing
VHR-4N and JST Series
SVH-21T-P1.1 crimp terminals.
Mounting holes marked with
must be connected to
safety earth
6
1
Mounting holes need to be
isolated from ground
0.12
(3.2)
0.12
(3.2)
0.86
(22.0)
0.06
(1.6)
0.09 (2.4)
Input Connector CN1
Pin 1
Neutral
Pin 2
Not Fitted
Pin 3
Line
CN1 mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals.
Output Connector CN2
Pin 1
V2
Pin 2
V1
Pin 3
V1
Pin 4
RTN
Pin 5
RTN
Pin 6
V3
CN2 mates with JST housing
VHR-6N and JST Series
SVH-21T-P1.1 crimp terminals.
Mounting holes marked with
must be connected to
safety earth
Notes
1. All dimensions are in inches (mm).
2. Weight: ECP40USXX: 0.18 lbs (80 g) approx, ECP40UD/UTXX: 0.24 lbs (110 g)
19-Feb-13
ACDC
ECP40
Models and Ratings
Similar pages