MHI600ARWI8SSeries Wide Input, 6W DIP Ultra-High Isolation DC/DC Converters Electrical Specifications Key Features: • 6W Output Power • 8.0 kV Isolation Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range • 15 kV/µS CMTI • Wide 2:1 Input Range Start-Up Threshold Voltage • Reinforced Insulation • EN 60950 Approved (Pend.) • -40°C to +75°C Operation • Industry Standard Pin-Out Under Voltage Shutdown Short Circuit Input Power Input Filter Conducted EMI Conditions 12 VDC Input 24 VDC Input 48 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input Min. 9.0 18.0 36.0 7.0 13.0 30.0 Typ. 12.0 24.0 48.0 8.0 15.0 33.0 Max. 18.0 36.0 75.0 9.0 18.0 36.0 8.5 16.0 34.0 3,000 Units VDC VDC VDC mW (Pi) Filter Meets EN 55022 Class A & FCC Level A Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Conditions Ripple & Noise (20 MHz)< See Note 3 Transient Recovery Time, See Note 4 Transient Response Deviation Output Power Protection Temperature Coefficient Output Short Circuit Min. Typ. Dual Output, Balanced Loads VIN = Min to Max See Note 2 5 VDC Output Models All Other Models ±0.5 ±0.3 ±0.5 75 100 300 25% Load Step Change ±3.0 Foldback 120 150 ±0.02 Continuous (Autorecovery) Max. ±1.0 ±2.0 ±0.5 ±1.0 100 150 500 ±6.0 ±0.05 Units % % % % mV P - P µSec % % %/°C General Parameter Isolation Voltage, 60 Sec Isolation Resistance Isolation Capacitance Common Mode Transient Immunity Switching Frequency Conditions Rated For 60 Sec Tested For 1 Sec 500 VDC 100 kHz, 1V Min. 4,000 8,000 10 Typ. Max. 7 13 15 150 Units VAC rms VDC G pF kV/µS kHz Environmental Parameter Conditions Operating Temperature Range MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Ambient Case Min. -40 Typ. +25 -50 Free Air Convection RH, Non-condensing Max. +75 +95 +125 Units 95 % °C °C See Mechanical Diagram (Page 3) Non-Conductive Black Plastic (UL94-V0) 0.57 Oz (16.2g) Reliability Specifications Parameter MTBF Safety Standards Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 700 UL 60950, EN 60950 (Pending) Max. Units kHours Max. 25.0 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (0.1 Sec) Lead Temperature Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case for 10 Sec Min. Typ. Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Model Number MHI612S-05ARWI8 MHI612S-12ARWI8 MHI612D-12ARWI8 MHI612D-15ARWI8 MHI624S-05ARWI8 MHI624S-12ARWI8 MHI624D-12ARWI8 MHI624D-15ARWI8 MHI648S-05ARWI8 MHI648S-12ARWI8 MHI648D-12ARWI8 MHI648D-15ARWI8 Input Voltage (VDC) Nominal Range 12 9.0 - 18.0 12 9.0 - 18.0 12 9.0 - 18.0 12 9.0 - 18.0 24 18.0 - 36.0 24 18.0 - 36.0 24 18.0 - 36.0 24 18.0 - 36.0 48 36.0 - 75.0 48 36.0 - 75.0 48 36.0 - 75.0 48 36.0 - 75.0 Output Current (mA) Full-Load No-Load 563 30 649 30 641 30 641 30 274 20 316 20 313 20 313 20 137 10 158 10 156 10 156 10 Voltage Current Current (VDC) (mA, Max) (mA, Min) 5.0 12.0 ±12.0 ±15.0 5.0 12.0 ±12.0 ±15.0 5.0 12.0 ±12.0 ±15.0 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is measured over a range of 25% IOUT to 100% IOUT. 3. When measuring output ripple & noise, it is recommended that an external capacitor (0.47 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. To further reduce output ripple, a 3.3 µF is recommended. 4. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 5. The converter should be connected to a low ac-impedance source. A source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (<1.0 at 100 kHz) capacitor be mounted close to the converter. For the 12 V input units a 10 µF is recommended, for 24V input units a 4.7 µF and for 48V units a 2.2 µF. 6. Operation at no-load will not damage the unit, but they may not meet all specifications. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection tables for the correct rating. 1,000 500 ±250 ±200 1,000 500 ±250 ±200 1,000 500 ±250 ±200 (%, Typ) Capacitive Load (µF, Max) (mA) 74 77 78 78 76 79 80 80 76 79 80 80 1,000 470 220 220 1,000 470 220 220 1,000 470 220 220 1,200 1,200 1,200 1,200 600 600 600 600 300 300 300 300 Efficiency 200.0 100.0 ±50.0 ±40.0 200.0 100.0 ±50.0 ±40.0 200.0 100.0 ±50.0 ±40.0 Fuse Rating Slow-Blow Derating Curve IGBT Applications Notes: The MHI600x-xARW series is a good choice for applications involving high speed switching, such as driving IGBTs. They are designed to withstand the extra stress caused by the high voltage switching transients present in IGBT drive circuits. All of the MHIxxx series have isolation levels that range from 5.2 to 8 kV. Many of these have reinforced insulation. The high isolation levels (and the correspondingly low capacitive coupling rates) allow them to be safely used in applications with highly dynamic switched AC or DC. Mechanical Dimensions Pin Connections Pin 1 11 12 13 15 23 24 Single Output +VIN No Pin -VOUT +VOUT No Pin -VIN -VIN Pin 1 11 12 13 15 23 24 Dual Output +VIN Common No Pin -VOUT +VOUT -VIN -VIN Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]