Pan Jit EST1GF AD 00001 Superfast recovery rectifier Datasheet

EST1GF
SUPERFAST RECOVERY RECTIFIERS
VOLTAGE
400 Volts
1 Amperes
CURRENT
FEATURES
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O
Flame Retardant Epoxy Molding Compound
• Exceeds environmental standards of MIL-S-19500/228
• Super fast recovery times, high voltage
• Ultra Thin Profile Package for Space Constrained Utilization
• Package suitable for Automated Handling
• Lead free in comply with EU RoHS 2011/65/EU directives
• Green molding compound as per IEC61249 Std. . (Halogen Free)
MECHANICAL DATA
Case : SMAF Molded Plastic
Terminals : Solderable per MIL-STD-750, Method 2026
Polarity : Color band denotes cathode end
Standard packaging : 12mm tape (EIA-481)
Weight : 0.0011 ounces, 0.0328 grams
Marking : EST1GF
1
2
Cathode
Anode
MAXIMUM RATINGS(TA=25oC unless otherwise noted)
PARAMETER
SYMBOL
VALUE
UNIT
Maximum recurrent peak reverse voltage
VRRM
400
V
Maximum rms voltage
VRMS
280
V
VR
400
V
Maximum average forward rectified current
I F(AV)
1
A
Peak forward surge current 8.3ms single half sine-wave
superimposed on rated load
I FSM
30
A
Maximum forward voltage at 1A
VF
1.25
V
Maximum dc reverse current
IR
1
A
Typical junction capacitance
Measured at 1MHz and applied VR=4V
CJ
16
pF
Maximum dc blocking voltage
Typical thermal resistance
(Note 1)
(Note 2)
RJL
RJA
20
150
Maximum reverse recovery time
(Note 3)
TRR
25
TJ
-55 to + 150
o
C
TSTG
-55 to + 150
o
C
Operating junction temperature range
Storage temperature range
o
C/W
nS
Note:1.Mounted on an FR4 PCB, single-sided copper, with 100cm2 copper pad area
2.Mounted on an FR4 PCB, single-sided copper, mini pad.
3.Reverse Recovery Test Conditions : I F=0.5A, I R=1A, Recover to 0.25A.
July 16,2013-REV.00
PAGE . 1
1.2
CJ, Junction Capacitance (pF)
IF, Forward Current (A)
EST1GF
1
0.8
0.6
0.4
0.2
0
0
25
50
75
100
125
150
100
10
1
1
TC, Case Temperature (°C)
Fig.2 Typical Junction Capacitance
10
TJ = 150°C
IF, Forward Current (A)
IR, Reverse Current (μA)
100
10
1
TJ = 125°C
0.1
TJ = 75°C
0.01
TJ = 25°C
0.001
20
30
40
50
60
70
80
90
100
TJ = 150°C
1
TJ = 125°C
TJ = 75°C
0.1
TJ = 25°C
0.01
0.2
Percent of Rated Peak Reverse Voltage (%)
Fig.3 Typical Reverse Characteristics
July 16,2013-REV.00
100
VR, Reverse Bias Voltage (V)
Fig.1 Forward Current Derating Curve
10
10
0.4
0.6
0.8
1
1.2
1.4
VF, Forward Voltage (V)
Fig.4 Typical Forward Characteristics
PAGE . 2
EST1GF
MOUNTING PAD LAYOUT
0.232
(5.9)
0.063
(1.6)
0.075
(1.9)
0.106
(2.7)
ORDER INFORMATION
• Packing information
T/R - 10K per 13" plastic Reel
T/R - 3K per 7" plastic Reel
July 16,2013-REV.00
PAGE . 3
EST1GF
Part No_packing code_Version
EST1GF_R1_00001
EST1GF_R2_00001
For example :
RB500V-40_R2_00001
Serial number
Version code means HF
Packing size code means 13"
Part No.
Packing type means T/R
Packing Code XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
July 16,2013-REV.00
Version Code XXXXX
1st Code
Packing size code
A
N/A
0
HF
0
serial number
R
7"
1
RoHS
1
serial number
B
13"
2
T
26mm
X
S
52mm
Y
L
F
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
2nd Code HF or RoHS 1st Code 2nd~5th Code
U
D
PAGE . 4
EST1GF
Disclaimer
• Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
• Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
• Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
• Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
• Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
Panjit International Inc. makes no representation or warranty that such applications will be
suitable for the specified use without further testing or modification.
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
• Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
July 16,2013-REV.00
PAGE . 5
Similar pages