MPD MPL05S03E Mpl-05se sery Datasheet

MPL-05SE Series
Single Output, 5W
Ultra-Miniature SIP
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 5W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single Regulated Output
• Meets EN 55022 Class A
• >300 kHour MTBF
• Ultra-Miniature “SIP” Case
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
85
100
47
Input Voltage Range
Input Frequency
Typ.
115 VAC
230 VAC
115 VAC
230 VAC
Input Current
Inrush Current
Max.
264
400
63
0.15
0.20
20.0
30.0
Leakage Current
Units
VAC
VDC
Hz
A
A Pk
5.0
mA
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
VIN = Min to Max
±0.5
IOUT = 10% to 100%
±1.5
3.3V, 24V Models
50
All Other Models
50
115 VAC
20
230 VAC
80
±0.15
Continuous (Autorecovery)
Max.
Units
Conditions
Input to Output
Max.
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
%
%
150
120
mV P-P
mSec
%/°C
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
Min.
3,000
Typ.
100
Standard
See Note 2
EN 55022
See Note 2
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 3
EN 61000-4-4
See Note 4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
Units
VAC
kHz
Typ.
Max.
Units
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV /±4 kV
Criteria A; 3 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+85
+100
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Case
Min.
-25
Typ.
+25
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
1.65 x 0.43 x 1.06 Inches (42.0 x 11.0 x 27.0 mm)
Non-Conductive Epoxy (UL94-V0)
0.35 Oz (10g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Output
Model
Number
Voltage
Current
(VDC)
(mA Max.)
MPL-05S-03E
MPL-05S-05E
MPL-05S-09E
MPL-05S-12E
MPL-05S-15E
MPL-05S-24E
3.3
5.0
9.0
12.0
15.0
24.0
1,000
1,000
560
420
340
210
Typical Connection
Output
Max
Voltage Capacitive Efficiency
Accuracy
(%, Typ)
Load
(%)
(µF)
±2.0
±1.0
±1.0
±1.0
±1.0
±1.0
1,000
1,500
630
470
330
100
65
70
72
74
75
75
Notes:
1. Operation at no load will not damage the units, however, they may not meet all specifications.
2. All units are rated for EN 55022 (CE/RE) class A with the addition of external components such
as the typical circuit shown below. They will meet class B with the addition of the ACFM-01 (or a
similar discrete filter circuit). Contact the factory for more information.
3. To meet the requirements of EN 61000-4-4 (±4 kV), external components are needed. This
can be done discretely, or with the addition of the ACFM-01. Contact the factory for more
information.
4. To meet the requirements of EN 61000-4-5 (±4 kV/±4 kV), external components are needed.
This can be done discretely, or with the addition of the ACFM-01. Contact the factory for more
information.
5. It is recommended that a fuse be used on the input of a power supply for protection. For
the MPL-05SE series, a 1.0A/250 VAC slow blow should be used.
The diagram below illustrates a typical application connection of the MPL-05SE series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is recommended on the input to protect the unit in the event of
a surge. A 561KD14 or equivalent is recommended.
3. The filter capacitor C1 is required for specified operation. The recommended value
is 33 µF/400V.
4. The safety capacitors (Cx1 and CY0) provide EMI/RFI suppresion. Recommended
values are 0.22 µF/275 VAC (Cx1) and 1 nF/400 VAC (CY0).
5. Recommended values for other components are:
Output
3.3V
5.0V
9.0V
12V
15V
24V
Typical Board Layout: With ACFM-01 Input Module (See note 6)
L1
0.47 µH
0.47 µH
1.0 µH
1.0 µH
1.0 µH
4.7 µH
C2
470 µF/16V
470 µF/16V
330 µF/35V
330 µF/35V
330 µF/35V
100 µF/35V
C3
C4
TVS
150 µF/35V 100 nF/50V SMBJ7.0A
150 µF/35V 100 nF/50V SMBJ7.0A
150 µF/35V 100 nF/50V SMBJ12A
150 µF/35V 100 nF/50V SMBJ20A
150 µF/35V 100 nF/50V SMBJ20A
47 µF/35V 100 nF/50V SMBJ30A
The output filtering capacitors (C2,C3) are high frequency, low resistance electrolytic capacitors. Capacitor (C4) is ceramic. Voltage derating of capacitors should
be 80% or above.
6. Input noise and surge suppression modules are available for a number of MPD
AC/DC power supplies. An MPL-05SE connection with the ACFM-01 is illustrated
in the diagram at left. For pricing or full technical information on these modules
(ACFM-01 and ACFM-02) please contact the factory.
Pin Connections
Derating Curve
Pin
Function
Pin
Function
1
3
5
AC-Neutral
AC-Line
+VCAP
7
12
14
-VCAP
-VOUT
+VOUT
Mechanical Dimensions
Input Voltage Vs Load
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
FAX: (781) 344-8481
•
E-Mail: [email protected]