Series AM40E-Z 40 Watt | DC-DC Converter FEATURES: • • • • Wide 2:1 Input Range Adjustable Single Output Voltage Undervoltage lockout High Power Density Models Single output Model AM40E-1203SZ AM40E-1205SZ AM40E-1212SZ AM40E-1215SZ AM40E-2403SZ AM40E-2405SZ AM40E-2412SZ AM40E-2415SZ AM40E-4803SZ AM40E-4805SZ AM40E-4812SZ AM40E-4815SZ Input Voltage (V) Output Voltage (V) 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 Input Voltage (V) Output Voltage (V) Output Current max (A) 8 8 3.33 2.67 8 8 3.33 2.67 8 8 3.33 2.67 Models Dual output Model AM40E-1212DZ AM40E-1215DZ AM40E-2412DZ AM40E-2415DZ AM40E-4812DZ AM40E-4815DZ 9-18 9-18 18-36 18-36 36-75 36-75 Output Current max (A) ±12 ±15 ±12 ±15 ±12 ±15 ±1.67 ±1.33 ±1.67 ±1.33 ±1.67 ±1.33 • • • Efficiency up to 92% Remote On/Off Function Soft start Maximum Capacitive load (µF) Efficiency (%) 21800 13600 2300 1500 21800 13600 2300 1500 21800 13600 2300 1500 90 91 91 91 91 92 91 92 91 92 91 92 Maximum Capacitive load (µF) Efficiency (%) ±1200 ±750 ±1200 ±750 ±1200 ±750 91 92 91 92 92 92 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time On/Off control www.aimtec.com F 051e R12.C Nominal 12 24 48 Typical 9-18 18-36 36-75 π (Pi) Network 30 Maximum Units VDC ms 25 50 VDC 100 1 s ON: 3 ~12VDC or open circuit ; OFF – 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3 (OFF idle current: 5mA Typical) 12 24 48 Tel: +1 514 620 2722 1 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter Input Specifications (continued) Parameters Under voltage lockout Input Reflected Ripple Current Isolation Specifications Parameters Tested I/O voltage Case/Input and Output Resistance Capacitance Nominal Typical 12V ON/OFF 24V ON/OFF 48V ON/OFF 20 Conditions Maximum 8.6 / 7.9 17.8 / 16 33.5 / 30.5 VDC mA p-p Typical 3 sec 3 sec Rated 1600 1600 <1000 1000 Output Specifications Parameters Conditions Typical Cross Regulation (Dual Output Models) 25% load on one output 100% load on second load ±5 Voltage accuracy Over voltage protection Over load protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Voltage adjustment range (single) Minimum Load Current Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation www.aimtec.com F 051e R12.C Maximum 0 Conditions 100% load Derating above 55 Typical -40 to +125 270 Units % % % % %/oC mV p-p ±10 % % of Max Units -40 to +71 105 95 Nickel coated Copper 32 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm >328,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours 1.5mm from case for 10 sec 260 250 ±3 2 of 7 VDC VDC MOhm pF % of Iout Maximum 2.5 Free Air Convection Tel: +1 514 620 2722 Units % Zener diode clamp 130 Continuous Auto-Recovery ±0.5 ±0.5 ±1 ±0.02 100 150 3.3Vout/5Vout other models Ripple & Noise (20MHz Bandwidth) General Specifications ±1 HL-LL 0% to 100% load 0% to 100% load Units KHz o C o C o C %/ oC % RH g o C µS % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter Safety Specifications Parameters Agency Approval CE EN55022: 2006 + A1:2007, Class B IEC61000-3-2:2006+A2:2009 IEC61000-3-3:2008 EN55024:1998 + A1:2001 + A2:2003 IEC61000-4-2: 2008 IEC61000-4-3:2006+A1: 2007 IEC61000-4-4:2004 IEC61000-4-5:2005 IEC61000-4-6:2008 IEC61000-4-8:2009 NOTE: also designed to meet IEC 60950-1:2001 Safety Pin Out Specifications Pin 1 2 3 4 5 6 Single + V Input - V Input On/Off Control + V Output -V Output Trim Dual + V Input - V Input On/Off Control + V Output Common - V Output Dimensions 4 1 5 Bottom View 3 10.16 (0.40) 2.54 (0.10) F 051e R12.C 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) 5.08 (0.20) www.aimtec.com 6 10.16 (0.40) 25.40 (1.00) 2 10.16 (0.40) 2.54 (0.10) 5.08 (0.20) 5.08 (0.20) 50.80 (2.00) 10.16 (0.40) Single and Dual Output Models Tel: +1 514 620 2722 3 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter Trimming Derating 55 Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 71 80 100 Ambient Temperature º C www.aimtec.com F 051e R12.C Tel: +1 514 620 2722 4 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter Input Reflected Ripple Current Test Step Lin Current Probe + +V output +V input DC/DC Converter Cin DC Power Source - Load -V input -V output Input reflected ripple current is measured through a source inductor Lin(4.7uH) and a source capacitor Cin (47uF, ESR<1.0ohm at 100KHz) at a nominal input and full load Output Ripple and noise reduction + +V output +V input DC/DC Converter Cin Cout Load DC Power Source 10uF 10uF - -V input 1uF -V output To reduce ripple and noise, it is recommended to use a 1µF ceramic disk capacitor and a 10µF electrolytic Control ON/OFF pin connection example +V input On/Off Control 4 DC/DC Converter 5 6 -V input www.aimtec.com F 051e R12.C 7 Tel: +1 514 620 2722 5 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter EMI Filter C9 C7 L1 +Vin C1 C2 C3 C4 C5 C6 +Vout AM40E-xxyZ (Single Output) Load -Vin -Vout C8 C8 C7 L1 C1 C2 C3 +Vin C4 C5 AM40E-xxyZ (Dual Output) C6 -Vin www.aimtec.com F 051e R12.C Tel: +1 514 620 2722 6 of 7 +Vout COM Load -Vout Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40E-Z 40 Watt | DC-DC Converter Model AM40E-12xxSZ (single) AM40E-24xxSZ (single) AM40E-48xxSZ (single) AM40E-12xxDZ (dual) AM40E-24xxDZ (dual) AM40E-48xxDZ (dual) C1 220µF, 100V 220µF, 100V 220µF, 100V 220µF, 100V 220µF, 100V 220µF, 100V L1 Common Choke 68µH Common Choke 68µH Common Choke 68µH Common Choke 68µH Common Choke 68µH Common Choke 68µH C2/C3/C5/C6 1812,6.8µF, 50V 1812,4.7µF, 50V 1812,1.5µF, 50V 1812,6.8µF, 50V 1812,4.7µF, 50V 1812,1.5µF, 50V C4 330µF, 100V 220µF, 100V 220µF, 100V 330µF, 100V 220µF, 100V 220µF, 100V C7 C8 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV 1206,1000pF, 2KV C9 1206,1000pF, 2KV EFT/Surge +V output +V input C1 DC/DC Converter Load 220uF 100V -V input -V output NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.C Tel: +1 514 620 2722 7 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only