XP Power IMM0105S05 Dc-dc converter Datasheet

IMM01 Series
DC-DC Converter
1 Watt
xxx Series
• World Wide Medical Approvals
• Single and Dual Outputs
• 2 µA Patient Leakage Current
• SIP7 Package
• -20 °C to +100 °C Operation
• Full Load at 60 °C Ambient
• 1500 VAC Isolation, 1 MOPP
• MTBF 1 MHrs
• 3 Year Warranty
Dimensions:
IMM01:
0.76 x 0.36 x 0.44” (19.5 x 9.2 x 11.1 mm)
Models & Ratings
Input Voltage
Output Voltage
4.5-9.0 V
9.0-18.0 V
Output Current
Input current
No Load
Full Load
Maximum capacitive
load
Model Number
3V3
303 mA
75 mA
337 mA
2200 µF
IMM0105S3V3
5V
200 mA
75 mA
337 mA
2200 µF
IMM0105S05
12 V
83 mA
75 mA
327 mA
470 µF
IMM0105S12
15 V
67 mA
75 mA
327 mA
470 µF
IMM0105S15
±3.3 V
±150 mA
55 mA
337 mA
±1000 µF
IMM0105D03
±5 V
±100 mA
55 mA
337 mA
±1000 µF
IMM0105D05
±12 V
±42 mA
75 mA
327 mA
±220 µF
IMM0105D12
±15 V
±33 mA
75 mA
327 mA
±220 µF
IMM0105D15
3V3
303 mA
25 mA
163 mA
2200 µF
IMM0112S3V3
5V
200 mA
25 mA
163 mA
2200 µF
IMM0112S05
12 V
83 mA
25 mA
150 mA
470 µF
IMM0112S12
15 V
67 mA
25 mA
150 mA
470 µF
IMM0112S15
±3.3 V
±150 mA
55 mA
163 mA
±1000 µF
IMM0112D03
±5 V
±100 mA
55 mA
163 mA
±1000 µF
IMM0112D05
±12 V
±42 mA
30 mA
150 mA
±220 µF
IMM0112D12
±15 V
±33 mA
30 mA
150 mA
±220 µF
IMM0112D15
Notes
Input currents measured at low input voltage.
Mechanical Details
Pin Connections
0.76 (19.5)
0.02
(0.50)
0.36 (9.20)
Printed
Face
0.42
(10.6)
0.12
(3.0)
1
2
3
5
6
0.44
(11.1)
Bottom View
0.36
(9.20)
0.13
(3.20)
0.02
(0.50)
7
0.02
(0.50)
Single
-Vin
+Vin
Dual
-Vin
+Vin
3
Remote
On/Off
Remote
On/Off
5
6
7
+Vout
-Vout
No Pin
+Vout
Common
-Vout
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.008 lbs (3.6 g) approx.
3. Pin diameter: 0.02±0.002 (0.5±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
0.10
(2.54)
0.6 (15.24)
1
0.01
(0.25)
Pin
1
2
www.xppower.com
IMM01 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Minimum
Typical
4.5
9
Inrush Current
Input Reflected Ripple Current
Maximum
Units
Notes & Conditions
9
VDC
5 V nominal
12 V nominal
18
VDC
0.05
A2s
16
VDC for 100 ms
5 V models
25
VDC for 100 ms
12 V models
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
2
µA
30
mA pk-pk
Input Surge
Through 12 µH inductor and 47 µF capacitor
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Patient Leakage Current
±2
Initial Set Accuracy
Minimum Load
±1
0
3.3 V & 5.0 V at full load
%
12.0 V & 15.0 V at full load
%
No minimum load required
Line Regulation
±0.5
%
From minimum to maximum input
Load Regulation
2.0
%
From 10% to full load (2% from 0% to 10% load)
Cross Regulation
±5
%
On dual output models, when one output is at 25% load
and other is varied from 10% load to full load
Ripple & Noise
1/2
% pk-pk
For 12 V & 15 V/ 3.3 V & 5 V models. 20 MHz bandwidth.
Measured using 0.1 µF ceramic capacitor
Short Circuit Protection
Continuous fold-back mode, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
Overload Protection
Remote On/Off
190
250
0.03
%/ ˚C
310
%
Of nominal output current at nominal input voltage
Output is on if remote on/off (pin 3) is open
Output turns off if remote on/off (pin 3) is high (4.0-5.5 VDC max) or if 2-4 mA is applied.
General
Characteristic
Efficiency
Minimum
Typical
Maximum
Units
64
78
81
%
Isolation: Input to Output
1500
Switching Frequency
175
Isolation Resistance
109
Isolation Capacitance
Power Density
Mean Time Between Failure
Typical value is for IMM0112S12
VAC
At 250 VAC working voltage, 1 MOPP
1000
kHz
May enter burst mode frequency of 12-28 kHz at light load
27
pF
W/in3
8.31
1
Weight
Notes & Conditions
Ω
MHrs
0.008 (3.6)
MIL-HDBK-217F, +25 °C GB
lb (g)
Environmental
Characteristic
Maximum
Units
Operating Altitude
Minimum
3048
M
Transport Altitude
10,000
Operating Temperature
-20
Storage Temperature
-40
Case Temperature
Humidity
Typical
+100
°C
+125
°C
+105
°C
95
%RH
Cooling
Notes & Conditions
Derate linearly from 100% load at +60 °C to 0% at
+100 °C
Non-condensing
Natural convection
www.xppower.com
2
IMM01 Series
DC-DC Converter
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted
EN55011
Class A
See Application Note
Radiated
EN55011
Class A
EMC: Immunity
Standard
Test Level
Criteria
Medical Device EMC
Phenomenon
IEC60601-1-2
Ed 4.0:2014
As below
ESD Immunity
EN61000-4-2
±15 kV
A
Air Discharge
A
80% mod, 80 MHz - 2.7 GHz plus discrete
communcation proximity field frequencies
Radiated Immunity
EN61000-4-3
10 Vrms
Notes & Conditions
EFT/Burst
EN61000-4-4
2 kV
A
External input filter required, see applications note
Surge
EN61000-4-5
2 kV
A
External input filter required, see applications note
Conducted Immunity
EN61000-4-6
10 V rms
A
Magnetic Fields
EN61000-4-8
30 A/m
A
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
ANSI/AMMI ES60601-1
UL
CSA
CSA C22.2 No. 60601-1
TUV
EN60601-1
CB
IEC60601-1
Mechanical Details
0.76 (19.5)
0.02
(0.50)
0.36 (9.20)
Printed
Face
0.42
(10.6)
0.44
(11.1)
0.12
(3.0)
1
2
3
5
6
Bottom View
0.36
(9.20)
0.02
(0.50)
7
0.02
(0.50)
Pin Connections
0.10
(2.54)
Pin
1
2
0.6 (15.24)
Notes
3
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
1. All dimensions are in inches (mm)
2. Weight: 0.008 lbs (3.6 g) approx.
3. Pin diameter: 0.02±0.002 (0.5±0.05)
External Filter for Surge and EFT
-Vin
On/Off
Remote
On/Off
+Vout
-Vout
No Pin
+Vout
Common
-Vout
+ Vin
L1
IMM01
LRemote
+ Vout
+ Vout
D1
Dual
-Vin
+Vin
EMI Filter Conducted Emissions
+ Vin
C1
Single
-Vin
+Vin
5
6
7
Application Note
Load
C1
C2
IMM01
-Vin
-Vout
C1 is 220 µF, 100 V electrolytic capacitor
D1 is 18 V, 3 kW TVS for 5 V input or 28 V, 3 kW TVS for 12 V input
3
0.01
(0.25)
0.13
(3.20)
Load
-Vout
C1 & C2 are 10 µF, 35 V multilayer ceramic chip capacitors, placed as close
as possible to the input pins
L1 is 12 µH inductor
www.xppower.com
12 April 16
Similar pages