Not Recommended For New Designs bq2010 Gas Gauge IC Features General Description ➤ Conservative and repeatable measurement of available charge in rechargeable batteries The bq2010 Gas Gauge IC is intended for battery-pack or in-system installation to maintain an accurate record of a battery's available charge. The IC monitors a voltage drop across a sense resistor connected in series between the negative battery terminal and ground to determine charge and discharge activity of the battery. ➤ Designed for battery pack integration - 120µA typical standby current - Small size enables implementations in as little as 1 2 square inch of PCB ➤ Integrate within a system or as a stand-alone device - Display capacity via singlewire serial communication port or direct drive of LEDs ➤ Measurements compensated for current and temperature ➤ Self-discharge compensation using internal temperature sensor NiMH and NiCd battery self-discharge is estimated based on an internal timer and temperature sensor. Compensations for battery temperature and rate of charge or discharge are applied to the charge, discharge, and self-discharge calculations to provide available charge information across a wide range of operating conditions. Battery capacity is automatically recalibrated, or “learned,” in the course of a discharge cycle from full to empty. ➤ 16-pin narrow SOIC Nominal available charge may be directly indicated using a five- or six-segment LED display. These segments are used to indicate graphically the nominal available charge. Pin Connections Pin Names ➤ Accurate measurements across a wide range of current (> 500:1) LCOM LCOM 1 16 VCC SEG1/PROG1 2 15 REF SEG2/PROG2 3 14 NC SEG3/PROG3 4 13 DQ SEG4/PROG4 5 12 EMPTY SEG5/PROG5 6 11 SB SEG6/PROG6 7 10 DISP VSS 8 9 SR 16-Pin Narrow SOIC LED common output The bq2010 supports a simple single-line bidirectional serial link to an external processor (common ground). The bq2010 outputs battery information in response to external commands over the serial link. The bq2010 may operate directly from 3 or 4 cells. With the REF output and an external transistor, a simple, inexpensive regulator can be built to provide V CC across a greater number of cells. Internal registers include available charge, temperature, capacity, battery ID, battery status, and programming pin settings. To support subassembly testing, the outputs may also be controlled. The external processor may also overwrite some of the bq2010 gas gauge data registers. REF Voltage reference output NC No connect DQ Serial communications input/output EMPTY Empty battery indicator output SB Battery sense input DISP Display control input SEG5/PROG5 LED segment 5/ program 5 input SR Sense resistor input VCC 3.0–6.5V SEG6/PROG6 LED segment 6/ program 6 input VSS System ground SEG1/PROG1 LED segment 1/ program 1 input SEG2/PROG2 LED segment 2/ program 2 input SEG3/PROG3 LED segment 3/ program 3 input SEG4/PROG4 LED segment 4/ program 4 input PN201001.eps 4/95 D 1 Not Recommended For New Designs bq2010 SR Pin Descriptions LCOM The voltage drop (VSR) across the sense resistor RS is monitored and integrated over time to interpret charge and discharge activity. The SR input is tied to the high side of the sense resistor. VSR < VSS indicates discharge, and VSR > VSS indicates charge. The effective voltage drop, VSRO, as seen by the bq2010 is VSR + VOS (see Table 5). LED common output Open-drain output switches VCC to source current for the LEDs. The switch is off during initialization to allow reading of the soft pull-up or pull-down program resistors. LCOM is also high impedance when the display is off. SEG1– SEG6 LED display segment outputs (dual function with PROG1–PROG6) DISP Programmed full count selection inputs (dual function with SEG1–SEG2) These three-level input pins define the programmed full count (PFC) thresholds described in Table 2. PROG3– PROG4 SB Gas gauge rate selection inputs (dual function with SEG3–SEG4) Self-discharge rate selection (dual function with SEG5) EMPTY Display mode selection (dual function with SEG6) DQ Serial I/O pin This is an open-drain bidirectional pin. This three-level pin defines the display operation shown in Table 1. NC Battery empty output This open-drain output becomes high-impedance on detection of a valid end-of-discharge voltage (VEDVF) and is low following the next application of a valid charge. This three-level input pin defines the selfdischarge compensation rate shown in Table 1. PROG6 Secondary battery input This input monitors the single-cell voltage potential through a high-impedance resistive divider network for end-of-discharge voltage (EDV) thresholds, maximum charge voltage (MCV), and battery removed. These three-level input pins define the scale factor described in Table 2. PROG5 Display control input DISP high disables the LED display. DISP tied to VCC allows PROGX to connect directly to VCC or VSS instead of through a pull-up or pull-down resistor. DISP floating allows the LED display to be active during discharge or charge if the NAC registers update at a rate equivalent to |VSRO| ≥ 4mV. DISP low activates the display. See Table 1. Each output may activate an LED to sink the current sourced from LCOM. PROG1– PROG2 Sense resistor input REF No connect Voltage reference output for regulator REF provides a voltage reference output for an optional micro-regulator. 2 VCC Supply voltage input VSS Ground Not Recommended For New Designs bq2010 Figure 1 shows a typical battery pack application of the bq2010 using the LED display capability as a chargestate indicator. The bq2010 can be configured to display capacity in either a relative or an absolute display mode. The relative display mode uses the last measured discharge capacity of the battery as the battery “full” reference. The absolute display mode uses the programmed full count (PFC) as the full reference, forcing each segment of the display to represent a fixed amount of charge. A push-button display feature is available for momentarily enabling the LED display. Functional Description General Operation The bq2010 determines battery capacity by monitoring the amount of charge input to or removed from a rechargeable battery. The bq2010 measures discharge and charge currents, estimates self-discharge, monitors the battery for low-battery voltage thresholds, and compensates for temperature and charge/discharge rates. The charge measurement derives from monitoring the voltage across a small-value series sense resistor between the negative battery terminal and ground. The available battery charge is determined by monitoring this voltage over time and correcting the measurement for the environmental and operating conditions. The bq2010 monitors the charge and discharge currents as a voltage across a sense resistor (see RS in Figure 1). A filter between the negative battery terminal and the SR pin may be required if the rate of change of the battery current is too great. R1 bq2010 Gas Gauge IC Q1 ZVNL110A REF LCOM SEG1/PROG1 VCC C1 0.1µF SB VCC SEG2/PROG2 SEG3/PROG3 DISP SEG4/PROG4 SR VCC SEG5/PROG5 SEG6/PROG6 RB1 RB2 RS VSS EMPTY DQ Charger Indicates optional. Directly connect to VCC across 3 or 4 cells (3 to 5.6V nominal) with a resistor and a Zener diode to limit voltage during charge. Otherwise, R1, C1, and Q1 are needed for regulation of >4 cells. The value of R1 depends on the number of cells. Load Programming resistors (6 max.) and ESD-protection diodes are not shown. R-C on SR may be required, application-specific. FG201001.eps Figure 1. Battery Pack Application Diagram—LED Display 3 Not Recommended For New Designs bq2010 charge display translation. The temperature range is available over the serial port in 10°C increments as shown below: Voltage Thresholds In conjunction with monitoring VSR for charge/discharge currents, the bq2010 monitors the single-cell battery potential through the SB pin. The single-cell voltage potential is determined through a resistor/divider network according to the following equation: TMPGG (hex) Temperature Range 0x < -30°C 1x -30°C to -20°C 2x -20°C to -10°C 3x -10°C to 0°C 4x 0°C to 10°C 5x 10°C to 20°C VEDV1 (early warning) = 1.05V 6x 20°C to 30°C VEDVF (empty) = 0.95V 7x 30°C to 40°C 8x 40°C to 50°C 9x 50°C to 60°C Ax 60°C to 70°C Bx 70°C to 80°C Cx > 80°C RB1 = N−1 RB2 where N is the number of cells, RB1 is connected to the positive battery terminal, and RB2 is connected to the negative battery terminal. The single-cell battery voltage is monitored for the end-of-discharge voltage (EDV) and for maximum cell voltage (MCV). EDV threshold levels are used to determine when the battery has reached an “empty” state, and the MCV threshold is used for fault detection during charging. Two EDV thresholds for the bq2010 are fixed at: If VSB is below either of the two EDV thresholds, the associated flag is latched and remains latched, independent of V S B , until the next valid charge. EDV monitoring may be disabled under certain conditions as described in the next paragraph. During discharge and charge, the bq2010 monitors VSR for various thresholds. These thresholds are used to compensate the charge and discharge rates. Refer to the count compensation section for details. EDV monitoring is disabled if VSR ≤ -250mV typical and resumes 1 2 second after VSR > -250mV. EMPTY Output Layout Considerations The EMPTY output switches to high impedance when VSB < VEDVF and remains latched until a valid charge occurs. The bq2010 also monitors VSB relative to VMCV, 2.25V. VSB falling from above VMCV resets the device. The bq2010 measures the voltage differential between the SR and VSS pins. VOS (the offset voltage at the SR pin) is greatly affected by PC board layout. For optimal results, the PC board layout should follow the strict rule of a single-point ground return. Sharing high-current ground with small signal ground causes undesirable noise on the small signal nodes. Additionally: Reset The bq2010 recognizes a valid battery whenever VSB is greater than 0.1V typical. VSB rising from below 0.25V or falling from above 2.25V resets the device. Reset can also be accomplished with a command over the serial port as described in the Reset Register section. n The capacitors (SB and VCC) should be placed as close as possible to the SB and VCC pins, respectively, and their paths to VSS should be as short as possible. A high-quality ceramic capacitor of 0.1µf is recommended for VCC. n The sense resistor capacitor should be placed as close as possible to the SR pin. n The sense resistor (RSNS) should be as close as possible to the bq2010. Temperature The bq2010 internally determines the temperature in 10°C steps centered from -35°C to +85°C. The temperature steps are used to adapt charge and discharge rate compensations, self-discharge counting, and available 4 Not Recommended For New Designs bq2010 1. Gas Gauge Operation The operational overview diagram in Figure 2 illustrates the operation of the bq2010. The bq2010 accumulates a measure of charge and discharge currents, as well as an estimation of self-discharge. Charge and discharge currents are temperature and rate compensated, whereas self-discharge is only temperature compensated. LMD is the last measured discharge capacity of the battery. On initialization (application of VCC or battery replacement), LMD = PFC. During subsequent discharges, the LMD is updated with the latest measured capacity in the Discharge Count Register (DCR) representing a discharge from full to below EDV1. A qualified discharge is necessary for a capacity transfer from the DCR to the LMD register. The LMD also serves as the 100% reference threshold used by the relative display mode. The main counter, Nominal Available Charge (NAC), represents the available battery capacity at any given time. Battery charging increments the NAC register, while battery discharging and self-discharge decrement the NAC register and increment the DCR (Discharge Count Register). 2. The Discharge Count Register (DCR) is used to update the Last Measured Discharge (LMD) register only if a complete battery discharge from full to empty occurs without any partial battery charges. Therefore, the bq2010 adapts its capacity determination based on the actual conditions of discharge. Battery capacity (mAh) * sense resistor (Ω) = PFC (mVh) Selecting a PFC slightly less than the rated capacity for absolute mode provides capacity above the full reference for much of the battery's life. Charge Current Discharge Current Self-Discharge Timer Rate and Temperature Compensation Rate and Temperature Compensation Temperature Compensation + Main Counters and Capacity Reference (LMD) Programmed Full Count (PFC) or initial battery capacity: The initial LMD and gas gauge rate values are programmed by using PROG1–PROG4. The PFC also provides the 100% reference for the absolute display mode. The bq2010 is configured for a given application by selecting a PFC value from Table 2. The correct PFC may be determined by multiplying the rated battery capacity in mAh by the sense resistor value: The battery's initial capacity is equal to the Programmed Full Count (PFC) shown in Table 2. Until LMD is updated, NAC counts up to but not beyond this threshold during subsequent charges. This approach allows the gas gauge to be charger-independent and compatible with any type of charge regime. Inputs Last Measured Discharge (LMD) or learned battery capacity: + - Nominal Available Charge (NAC) < Last Measured Discharged (LMD) Temperature Step, Other Data Temperature Translation Outputs Chip-Controlled Available Charge LED Display + Discharge Count Qualified Register (DCR) Transfer Serial Port FG201002.eps Figure 2. Operational Overview 5 Not Recommended For New Designs bq2010 Example: Selecting a PFC Value Select: Given: PFC = 33792 counts or 211mVh PROG1 = float PROG2 = float PROG3 = float PROG4 = low PROG5 = float PROG6 = float Sense resistor = 0.1Ω Number of cells = 6 Capacity = 2200mAh, NiCd battery Current range = 50mA to 2A Absolute display mode Serial port only Self-discharge = C 64 Voltage drop over sense resistor = 5mV to 200mV The initial full battery capacity is 211mVh (2110mAh) until the bq2010 “learns” a new capacity with a qualified discharge from full to EDV1. Therefore: 2200mAh * 0.1Ω = 220mVh Table 1. bq2010 Programming Pin Connection PROG5 Self-Discharge Rate PROG6 Display Mode DISP Display State H Disabled Absolute NAC = PFC on reset LED disabled Absolute NAC = 0 on reset LED-enabled on discharge or charge when equivalent |VSRO| ≥ 4mV Relative NAC = 0 on reset LED on Z NAC L NAC Note: 64 47 PROG5 and PROG6 states are independent. Table 2. bq2010 Programmed Full Count mVh Selections 1 2 Programmed Full Count (PFC) - - - Scale = 1/80 Scale = 1/160 Scale = 1/320 Scale = 1/640 Scale = 1/1280 Scale = 1/2560 mVh/ count H H 49152 614 307 154 76.8 38.4 19.2 mVh H Z 45056 563 282 141 70.4 35.2 17.6 mVh H L 40960 512 256 128 64.0 32.0 16.0 mVh Z H 36864 461 230 115 57.6 28.8 14.4 mVh Z Z 33792 422 211 106 53.0 26.4 13.2 mVh Z L 30720 384 192 96.0 48.0 24.0 12.0 mVh L H 27648 346 173 86.4 43.2 21.6 10.8 mVh L Z 25600 320 160 80.0 40.0 20.0 10.0 mVh L L 22528 282 141 70.4 35.2 17.6 8.8 mVh 90 45 22.5 11.25 5.6 2.8 mV PROGx VSR equivalent to 2 counts/sec. (nom.) PROG4 = L PROG3 = H PROG4 = Z PROG3 = Z PROG3 = L PROG3 = H PROG3 = Z PROG3 = L 6 Units Not Recommended For New Designs bq2010 3. 4. Nominal Available Charge (NAC): Discharge Counting NAC counts up during charge to a maximum value of LMD and down during discharge and self-discharge to 0. NAC is reset to 0 on initialization (PROG6 = Z or low) and on the first valid charge following discharge to EDV1. NAC is set to PFC on initialization if PROG6 = high. To prevent overstatement of charge during periods of overcharge, NAC stops incrementing when NAC = LMD. All discharge counts where VSRO < VSRD cause the NAC register to decrement and the DCR to increment. Exceeding the fast discharge threshold (FDQ) if the rate is equivalent to VSRO < -4mV activates the display, if enabled. The display becomes inactive after VSRO rises above -4mV. V SRD is a programmable threshold as described in the Digital Magnitude Filter section. The default value for VSRD is -300µV. Discharge Count Register (DCR): Self-Discharge Estimation The DCR counts up during discharge independent of NAC and could continue increasing after NAC has decremented to 0. Prior to NAC = 0 (empty battery), both discharge and self-discharge increment the DCR. After NAC = 0, only discharge increments the DCR. The DCR resets to 0 when NAC = LMD. The DCR does not roll over but stops counting when it reaches ffffh. The bq2010 continuously decrements NAC and increments DCR for self-discharge based on time and temperature. The self-discharge count rate is programmed to be a nominal 1 64 * NAC, 1 47 * NAC per day, or disabled as selected by PROG5. This is the rate for a battery whose temperature is between 20°–30°C. The NAC register cannot be decremented below 0. The DCR value becomes the new LMD value on the first charge after a valid discharge to VEDV1 if: Count Compensations The bq2010 determines fast charge when the NAC updates at a rate of ≥ 2 counts/sec. Charge and discharge activity is compensated for temperature and charge/discharge rate before updating the NAC and/or DCR. Selfdischarge estimation is compensated for temperature before updating the NAC or DCR. No valid charge initiations (charges greater than 256 NAC counts, where VSRO > VSRQ) occurred during the period between NAC = LMD and EDV1 detected. The self-discharge count is not more than 4096 counts (8% to 18% of PFC, specific percentage threshold determined by PFC). Charge Compensation Two charge efficiency compensation factors are used for trickle charge and fast charge. Fast charge is defined as a rate of charge resulting in ≥ 2 NAC counts/sec (≥ 0.15C to 0.32C depending on PFC selections; see Table 2). The compensation defaults to the fast charge factor until the actual charge rate is determined. The temperature is ≥ 0°C when the EDV1 level is reached during discharge. The valid discharge flag (VDQ) indicates whether the present discharge is valid for LMD update. Charge Counting Temperature adapts the charge rate compensation factors over three ranges between nominal, warm, and hot temperatures. The compensation factors are shown below. Charge activity is detected based on a positive voltage on the VSR input. If charge activity is detected, the bq2010 increments NAC at a rate proportional to VSRO and, if enabled, activates an LED display if the rate is equivalent to VSRO > 4mV. Charge actions increment the NAC after compensation for charge rate and temperature. The bq2010 determines charge activity sustained at a continuous rate equivalent to VSRO > VSRQ. A valid charge equates to sustained charge activity greater than 256 NAC counts. Once a valid charge is detected, charge counting continues until VSRO (VSR + VOS) falls below VSRQ. VSRQ is a programmable threshold as described in the Digital Magnitude Filter section. The default value for VSRQ is 375µV. Charge Temperature Trickle Charge Compensation Fast Charge Compensation <30°C 0.80 0.95 30–40°C 0.75 0.90 > 40°C 0.65 0.80 Discharge Compensation Corrections for the rate of discharge are made by adjusting an internal discharge compensation factor. The discharge compensation factor is based on the namically measured VSR. 7 Not Recommended For New Designs bq2010 The compensation factors during discharge are: Digital Magnitude Filter Approximate VSR Threshold Discharge Compensation Factor Efficiency VSR > -150 mV 1.00 100% VSR < -150 mV 1.05 95% The bq2010 has a programmable digital filter to eliminate charge and discharge counting below a set threshold. The default setting is -0.30mV for V SRD and +0.38mV for VSRQ. The proper digital filter setting can be calculated using the following equation. Table 4 shows typical digital filter settings. VSRD (mV) = -45 / DMF VSRQ (mV) = -1.25 * VSRD Temperature compensation during discharge also takes place. At lower temperatures, the compensation factor increases by 0.05 for each 10°C temperature step below 10°C. Table 4. Typical Digital Filter Settings Comp. factor = 1.0 + (0.05 * N) DMF 75 100 150 (default) 175 200 Where N = Number of 10°C steps below 10°C and -150mV < V SR < 0. For example: T > 10°C : Nominal compensation, N = 0 DMF Hex. 4B 64 96 AF C8 VSRD (mV) -0.60 -0.45 -0.30 -0.26 -0.23 VSRQ (mV) 0.75 0.56 0.38 0.32 0.28 0°C < T < 10°C: N = 1 (i.e., 1.0 becomes 1.05) -10°C < T < 0°C: N = 2 (i.e., 1.0 becomes 1.10) Error Summary -20°C < T < -10°C: N = 3 (i.e., 1.0 becomes 1.15) Capacity Inaccurate -20°C < T < -30°C: N = 4 (i.e., 1.0 becomes 1.20) The LMD is susceptible to error on initialization or if no updates occur. On initialization, the LMD value includes the error between the programmed full capacity and the actual capacity. This error is present until a valid discharge occurs and LMD is updated (see the DCR description on page 7). The other cause of LMD error is battery wear-out. As the battery ages, the measured capacity must be adjusted to account for changes in actual battery capacity. Self-Discharge Compensation The self-discharge compensation is programmed for a nominal rate of 1 64 * NAC, 1 47 * NAC per day, or disabled. This is the rate for a battery within the 20–30°C temperature range (TMPGG = 6x). This rate varies across 8 ranges from <10°C to >70°C, doubling with each higher temperature step (10°C). See Table 3. A Capacity Inaccurate counter (CPI) is maintained and incremented each time a valid charge occurs (qualified by NAC; see the CPI register description) and is reset whenever LMD is updated from the DCR. The counter does not wrap around but stops counting at 255. The capacity inaccurate flag (CI) is set if LMD has not been updated following 64 valid charges. Table 3. Self-Discharge Compensation Typical Rate Temperature Range PROG5 = Z < 10°C NAC 10–20°C NAC 20–30°C NAC 30–40°C NAC 40–50°C NAC 50–60°C NAC 60–70°C NAC > 70°C NAC 256 128 64 32 16 8 4 2 PROG5 = L NAC NAC NAC NAC NAC NAC NAC Current-Sensing Error 188 NAC Table 5 illustrates the current-sensing error as a function of VSR. A digital filter eliminates charge and discharge counts to the NAC register when VSRO (VSR + VOS) is between VSRQ and VSRD. 94 47 23.5 11.8 Communicating With the bq2010 5.88 The bq2010 includes a simple single-pin (DQ plus return) serial data interface. A host processor uses the interface to access various bq2010 registers. Battery characteristics may be easily monitored by adding a single contact to the battery pack. The open-drain DQ pin on 2.94 1.47 8 Not Recommended For New Designs bq2010 Table 5. bq2010 Current-Sensing Errors Symbol Parameter Typical Maximum Units ± 50 ± 150 µV Notes VOS Offset referred to VSR INL Integrated non-linearity error ±2 ±4 % Add 0.1% per °C above or below 25°C and 1% per volt above or below 4.25V. DISP = VCC. INR Integrated nonrepeatability error ±1 ±2 % Measurement repeatability given similar operating conditions. the bq2010 should be pulled up by the host system or may be left floating if the serial interface is not used. communication. The data should be held for a period, tDV, to allow the host or bq2010 to sample the data bit. The interface uses a command-based protocol, where the host processor sends a command byte to the bq2010. The command directs the bq2010 either to store the next eight bits of data received to a register specified by the command byte or to output the eight bits of data specified by the command byte. The final section is used to stop the transmission by returning the DQ pin to a logic-high state by at least a period, tSSU, after the negative edge used to start communication. The final logic-high state should be held until a period, tSV, to allow time to ensure that the bit transmission was stopped properly. The timings for data and break communication are given in the serial communication timing specification and illustration sections. The communication protocol is asynchronous return-toone. Command and data bytes consist of a stream of eight bits that have a maximum transmission rate of 333 bits/sec. The least-significant bit of a command or data byte is transmitted first. The protocol is simple enough that it can be implemented by most host processors using either polled or interrupt processing. Data input from the bq2010 may be sampled using the pulse-width capture timers available on some microcontrollers. Communication with the bq2010 is always performed with the least-significant bit being transmitted first. Figure 3 shows an example of a communication sequence to read the bq2010 NAC register. bq2010 Registers The bq2010 command and status registers are listed in Table 6 and described below. Communication is normally initiated by the host processor sending a BREAK command to the bq2010. A BREAK is detected when the DQ pin is driven to a logic-low state for a time, tB or greater. The DQ pin should then be returned to its normal ready-high logic state for a time, tBR. The bq2010 is now ready to receive a command from the host processor. Command Register (CMDR) The write-only CMDR register is accessed when eight valid command bits have been received by the bq2010. The CMDR register contains two fields: The return-to-one data bit frame consists of three distinct sections. The first section is used to start the transmission by either the host or the bq2010 taking the DQ pin to a logic-low state for a period, tSTRH,B. The next section is the actual data transmission, where the data should be valid by a period, tDSU, after the negative edge used to start W/R bit n Command address The W/R bit of the command register is used to select whether the received command is for a read or a write function. Written by Host to bq2010 CMDR = 03h LSB n Received by Host to bq2010 NAC = 65h MSB Break 1 1 0 0 0 0 0 0 LSB MSB 1 0 1 0 011 0 DQ TD201001.eps Figure 3. Typical Communication with the bq2010 9 Not Recommended For New Designs bq2010 Table 6. bq2010 Command and Status Registers Control Field Register Name Symbol Loc. (hex) Read/ Write 7(MSB) 6 5 4 3 2 1 0(LSB) CMDR Command register 00h Write W/R AD6 AD5 AD4 AD3 AD2 AD1 AD0 FLGS1 Primary status flags register 01h Read CHGS BRP BRM CI VDQ n/u EDV1 EDVF Temperature TMPGG and gas gauge register 02h Read TMP3 TMP2 TMP1 TMP0 GG3 GG2 GG1 GG0 NACH Nominal available charge high byte register 03h R/W NACH7 NACH6 NACH5 NACH4 NACH3 NACH2 NACH1 NACH0 NACL Nominal available charge low byte register 17h Read NACL7 NACL6 NACL5 NACL4 NACL3 NACL2 NACL1 NACL0 BATID Battery identification register 04h R/W BATID7 BATID6 BATID5 BATID4 BATID3 BATID2 BATID1 BATID0 LMD Last measured discharge register 05h R/W LMD7 LMD6 LMD5 LMD4 LMD3 LMD2 LMD1 LMD0 FLGS2 Secondary status flags register 06h Read CR DR2 DR1 DR0 n/u n/u n/u OVLD PPD Program pin pull-down register 07h Read n/u n/u PPD6 PPD5 PPD4 PPD3 PPD2 PPD1 PPU Program pin pull-up register 08h Read n/u n/u PPU6 PPU5 PPU4 PPU3 PPU2 PPU1 CPI Capacity inaccurate count register 09h Read CPI7 CPI6 CPI5 CPI4 CPI3 CPI2 CPI1 CPI0 DMF Digital magnitude filter register 0ah R/W DMF7 DMF6 DMF5 DMF4 DMF3 DMF2 DMF1 DMF0 RST Reset register 39h Write RST 0 0 0 0 0 0 0 Note: n/u = not used 10 Not Recommended For New Designs bq2010 tected after the EDV1 flag is asserted. BRP = 1 signifies that the device has been reset. The W/R values are: CMDR Bits The BRP values are: 7 6 5 4 3 2 1 0 W/R - - - - - - - FLGS1 Bits Where W/R is: 0 The bq2010 outputs the requested register contents specified by the address portion of CMDR. 1 The lower seven-bit field of CMDR contains the address portion of the register to be accessed. Attempts to write to invalid addresses are ignored. - 5 AD6 AD5 5 4 3 2 1 0 - BRP - - - - - - 4 3 2 1 0 AD4 AD3 AD2 AD1 AD0 (LSB) FLGS1 Bits 5 4 3 2 1 0 - - - - - - 7 6 5 4 3 2 1 0 - - BRM - - - - - 0 0.1V < VSB < 2.25V 1 0.1 V > VSB or VSB > 2.25V The capacity inaccurate flag (CI) is used to warn the user that the battery has been charged a substantial number of times since LMD has been updated. The CI flag is asserted on the 64th charge after the last LMD update or when the bq2010 is reset. The flag is cleared after an LMD update. The CHGS values are: - VSB dropping from above MCV, VSB rising from below 0.1V, or a serial port initiated reset has occurred Where BRM is: The charge status flag (CHGS) is asserted when a valid charge rate is detected. Charge rate is deemed valid when VSRO > VSRQ. A VSRO of less than VSRQ or discharge activity clears CHGS. 6 1 FLGS1 Bits The read-only FLGS1 register (address=01h) contains the primary bq2010 flags. 7 Battery is charged until NAC = LMD or discharged until the EDV1 flag is asserted The BRM values are: Primary Status Flags Register (FLGS1) CHGS 0 The battery removed flag (BRM) is asserted whenever the potential on the SB pin (relative to VSS) rises above MCV or falls below 0.1V. The BRM flag is asserted until the condition causing BRM is removed. CMDR Bits 6 6 Where BRP is: The following eight bits should be written to the register specified by the address portion of CMDR. 7 7 The CI values are: FLGS1 Bits Where CHGS is: 0 Either discharge activity detected or VSRO < VSRQ 1 VSRO > VSRQ 7 6 5 4 3 2 1 0 - - - CI - - - - Where CI is: The battery replaced flag (BRP) is asserted whenever the potential on the SB pin (relative to VSS), VSB, falls from above the maximum cell voltage, MCV (2.25V), or rises above 0.1V. The BRP flag is also set when the bq2010 is reset (see the RST register description). BRP is reset when either a valid charge action increments NAC to be equal to LMD, or a valid charge action is de- 11 0 When LMD is updated with a valid full discharge 1 After the 64th valid charge action with no LMD updates or the bq2010 is reset Not Recommended For New Designs bq2010 The EDVF values are: The valid discharge flag (VDQ) is asserted when the bq2010 is discharged from NAC=LMD. The flag remains set until either LMD is updated or one of three actions that can clear VDQ occurs: n n n FLGS1 Bits The self-discharge count register (SDCR) has exceeded the maximum acceptable value (4096 counts) for an LMD update. 7 6 5 4 3 2 1 0 - - - - - - - EDVF Where EDVF is: A valid charge action sustained at VSRO > VSRQ for at least 256 NAC counts. The EDV1 flag was set at a temperature below 0°C 0 Valid charge action detected, VSB ≥ 0.95V 1 VSB < 0.95V providing that OVLD=0 (see FLGS2 register description) The VDQ values are: Temperature and Gas Gauge Register (TMPGG) FLGS1 Bits 7 6 5 4 3 2 1 0 - - - - VDQ - - - The read-only TMPGG register (address=02h) contains two data fields. The first field contains the battery temperature. The second field contains the available charge from the battery. Where VDQ is: 0 SDCR ≥ 4096, subsequent valid charge action detected, or EDV1 is asserted with the temperature less than 0°C 1 On first discharge after NAC = LMD TMPGG Temperature Bits 7 6 5 TMP3 TMP2 The first end-of-discharge warning flag (EDV1) warns the user that the battery is almost empty. The first segment pin, SEG1, is modulated at a 4Hz rate if the display is enabled once EDV1 is asserted, which should warn the user that loss of battery power is imminent. The EDV1 flag is latched until a valid charge has been detected. 4 TMP1 TMP0 3 2 1 - - - 0 The bq2010 contains an internal temperature sensor. The temperature is used to set charge and discharge efficiency factors as well as to adjust the self-discharge coefficient. The temperature register contents may be translated as shown below. The EDV1 values are: FLGS1 Bits 7 6 5 4 3 2 1 0 - - - - - - EDV1 - Where EDV1 is: 0 1 Valid charge action detected, VSB ≥ 1.05V VSB < 1.05V providing that OVLD=0 (see FLGS2 register description) The final end-of-discharge warning flag (EDVF) is used to warn that battery power is at a failure condition. All segment drivers are turned off. The EDVF flag is latched until a valid charge has been detected. The EMPTY pin is also forced to a high-impedance state on assertion of EDVF. The host system may pull EMPTY high, which may be used to disable circuitry to prevent deep-discharge of the battery. 12 TMP3 TMP2 TMP1 TMP0 Temperature 0 0 0 0 T < -30°C 0 0 0 1 -30°C < T < -20°C 0 0 1 0 -20°C < T < -10°C 0 0 1 1 -10°C < T < 0°C 0 1 0 0 0°C < T < 10°C 0 1 0 1 10°C < T < 20°C 0 1 1 0 20°C < T < 30°C 0 1 1 1 30°C < T < 40°C 1 0 0 0 40°C < T < 50°C 1 0 0 1 50°C < T < 60°C 1 0 1 0 60°C < T < 70°C 1 0 1 1 70°C < T < 80°C 1 1 0 0 T > 80°C Not Recommended For New Designs bq2010 of the battery from full to empty. In this way the bq2010 updates the capacity of the battery. LMD is set to PFC during a bq2010 reset. The bq2010 calculates the available charge as a function of NAC, temperature, and a full reference, either LMD or PFC. The results of the calculation are available via the display port or the gas gauge field of the TMPGG register. The register is used to give available capacity in 1 16 increments from 0 to 15 16. 7 - 6 - TMPGG Gas Gauge Bits 5 4 3 2 GG3 GG2 1 GG1 Secondary Status Flags Register (FLGS2) The read-only FLGS2 register (address=06h) contains the secondary bq2010 flags. 0 GG0 The charge rate flag (CR) is used to denote the fast charge regime. Fast charge is assumed whenever a charge action is initiated. The CR flag remains asserted if the charge rate does not fall below 2 counts/sec. The gas gauge display and the gas gauge portion of the TMPGG register are adjusted for cold temperature dependencies. A piece-wise correction is performed as follows: Temperature > 0°C -20°C < T < 0°C < -20°C The CR values are: 7 CR Available Capacity Calculation NAC / “Full Reference” 0.75 * NAC / “Full Reference” 0.5 * NAC / “Full Reference” 6 - 5 - FLGS2 Bits 4 3 - 2 - 1 - 0 - Where CR is: The adjustment between > 0°C and -20°C < T < 0°C has a 10°C hysteresis. 0 When charge rate falls below 2 counts/sec 1 When charge rate is above 2 counts/sec The fast charge regime efficiency factors are used when CR = 1. When CR = 0, the trickle charge efficiency factors are used. The time to change CR varies due to the user-selectable count rates. Nominal Available Charge Registers (NACH/NACL) The discharge rate flags, DR2–0, are bits 6–4. The read/write NACH high-byte register (address=03h) and the read-only NACL low-byte register (address=17h) are the main gas gauging register for the bq2010. The NAC registers are incremented during charge actions and decremented during discharge and self-discharge actions. The correction factors for charge/discharge efficiency are applied automatically to NAC. 7 - FLGS2 Bits 5 4 3 DR1 DR0 - 6 DR2 2 - 1 - 0 They are used to determine the current discharge regime as follows: On reset, if PROG6 = Z or low, NACH and NACL are cleared to 0; if PROG6 = high, NACH = PFC and NACL = 0. When the bq2010 detects a valid charge, NACL resets to 0. Writing to the NAC registers affects the available charge counts and, therefore, affects the bq2010 gas gauge operation. Do not write the NAC registers to a value greater than LMD. DR2 0 0 DR1 0 0 DR0 0 1 VSR (V) VSR > -150mV VSR < -150mV The overload flag (OVLD) is asserted when a discharge overload is detected, VSR < -250mV. OVLD remains asserted as long as the condition persists and is cleared 0.5 seconds after VSR > -250mV. The overload condition is used to stop sampling of the battery terminal characteristics for end-of-discharge determination. Sampling is reenabled 0.5 secs after the overload condition is removed. Battery Identification Register (BATID) The read/write BATID register (address=04h) is available for use by the system to determine the type of battery pack. The BATID contents are retained as long as VCC is greater than 2V. The contents of BATID have no effect on the operation of the bq2010. There is no default setting for this register. 7 - Last Measured Discharge Register (LMD) LMD is a read/write register (address=05h) that the bq2010 uses as a measured full reference. The bq2010 adjusts LMD based on the measured discharge capacity 13 6 - 5 - FLGS2 Bits 4 3 - 2 - 1 - 0 OVLD Not Recommended For New Designs bq2010 DR2–0 and OVLD are set based on the measurement of the voltage at the SR pin relative to VSS. The rate at which this measurement is made varies with device activity. Digital Magnitude Filter (DMF) The read-write DMF register (address = 0ah) provides the system with a means to change the default settings of the digital magnitude filter. By writing different values into this register, the limits of VSRD and VSRQ can be adjusted. Program Pin Pull-Down Register (PPD) The read-only PPD register (address=07h) contains some of the programming pin information for the bq2010. The segment drivers, SEG1–6, have a corresponding PPD register location, PPD1–6. A given location is set if a pull-down resistor has been detected on its corresponding segment driver. For example, if SEG1 and SEG4 have pull-down resistors, the contents of PPD are xx001001. Note: Care should be taken when writing to this register. A VSRD and VSRQ below the specified VOS may adversely affect the accuracy of the bq2010. Refer to Table 4 for recommended settings for the DMF register. Reset Register (RST) The reset register (address=39h) provides the means to perform a software-controlled reset of the device. By writing the RST register contents from 00h to 80h, a bq2010 reset is performed. Setting any bit other than the most-significant bit of the RST register is not allowed, and results in improper operation of the bq2010. PPD/PPU Bits 7 6 5 4 3 2 1 0 - - PPU6 PPU5 PPU4 PPU3 PPU2 PPU1 - - PPD6 PPD5 PPD4 PPD3 PPD2 PPD1 Resetting the bq2010 sets the following: n LMD = PFC n CPI, VDQ, NACH, and NACL = 0 n CI and BRP = 1 Program Pin Pull-Up Register (PPU) The read-only PPU register (address=08h) contains the rest of the programming pin information for the bq2010. The segment drivers, SEG1–6, have a corresponding PPU register location, PPU1–6. A given location is set if a pullup resistor has been detected on its corresponding segment driver. For example, if SEG3 and SEG6 have pull-up resistors, the contents of PPU are xx100100. Note: NACH = PFC when PROG6 = H. Self-discharge is disabled when PROG5 = H Display The bq2010 can directly display capacity information using low-power LEDs. If LEDs are used, the program pins should be resistively tied to VCC or VSS for a program high or program low, respectively. Capacity Inaccurate Count Register (CPI) The read-only CPI register (address=09h) is used to indicate the number of times a battery has been charged without an LMD update. Because the capacity of a rechargeable battery varies with age and operating conditions, the bq2010 adapts to the changing capacity over time. A complete discharge from full (NAC=LMD) to empty (EDV1=1) is required to perform an LMD update assuming there have been no intervening valid charges, the temperature is greater than or equal to 0°C, and the self-discharge counter is less than 4096 counts. The bq2010 displays the battery charge state in either absolute or relative mode. In relative mode, the battery charge is represented as a percentage of the LMD. Each LED segment represents 20% of the LMD. The sixth segment, SEG6, is not used. In absolute mode, each segment represents a fixed amount of charge, based on the initial PFC. In absolute mode, each segment represents 20% of the PFC, with SEG6 representing “overfull” (charge above the PFC). As the battery wears out over time, it is possible for the LMD to be below the initial PFC. In this case, all of the LEDs may not turn on in absolute mode, representing the reduction in the actual battery capacity. The CPI register is incremented every time a valid charge is detected. When NAC > 0.94 * LMD, however, the CPI register increments on the first valid charge; CPI does not increment again for a valid charge until NAC < 0.94 * LMD. This prevents continuous trickle charging from incrementing CPI if self-discharge decrements NAC. The CPI register increments to 255 without rolling over. When the contents of CPI are incremented to 64, the capacity inaccurate flag, CI, is asserted in the FLGS1 register. The CPI register is reset whenever an update of the LMD register is performed, and the CI flag is also cleared. The capacity display is also adjusted for the present battery temperature. The temperature adjustment reflects the available capacity at a given temperature but does not affect the NAC register. The temperature adjustments are detailed in the TMPGG register description. When DISP is tied to VCC, the SEG1–6 outputs are inactive. When DISP is left floating, the display becomes active 14 Not Recommended For New Designs bq2010 SEG1 blinks at a 4Hz rate whenever VSB has been detected to be below VEDV1 (EDV1 = 1), indicating a lowbattery condition. VSB below VEDVF (EDVF = 1) disables the display output. whenever the NAC registers are counting at a rate equivalent to |VSRO| ≥ 4mV. When pulled low, the segment outputs become active immediately. A capacitor tied to DISP allows the display to remain active for a short period of time after activation by a push-button switch. Microregulator The segment outputs are modulated as two banks of three, with segments 1, 3, and 5 alternating with segments 2, 4, and 6. The segment outputs are modulated at approximately 100Hz with each segment bank active for 30% of the period. The bq2010 can operate directly from 3 or 4 cells. To facilitate the power supply requirements of the bq2010, an REF output is provided to regulate an external lowthreshold n-FET. A micropower source for the bq2010 can be inexpensively built using the FET and an external resistor; see Figure 1. Absolute Maximum Ratings Symbol Parameter Minimum Maximum Unit Notes VCC Relative to VSS -0.3 +7.0 V All other pins Relative to VSS -0.3 +7.0 V REF Relative to VSS -0.3 +8.5 V Current limited by R1 (see Figure 1) VSR Relative to VSS -0.3 +7.0 V Minimum 100Ω series resistor should be used to protect SR in case of a shorted battery (see the bq2010 application note for details). TOPR Operating temperature 0 +70 °C Commercial Note: Permanent device damage may occur if Absolute Maximum Ratings are exceeded. Functional operation should be limited to the Recommended DC Operating Conditions detailed in this data sheet. Exposure to conditions beyond the operational limits for extended periods of time may affect device reliability. DC Voltage Thresholds (TA = TOPR; V = 3.0 to 6.5V) Minimum Typical Maximum Unit VEDVF Symbol Final empty warning 0.93 0.95 0.97 V SB VEDV1 First empty warning 1.03 1.05 1.07 V SB VSR1 Discharge compensation threshold -120 -150 -180 mV SR, VSR + VOS VSRO SR sense range -300 - +2000 mV SR, VSR + VOS VSRQ Valid charge 375 - - µV VSR + VOS (see note) VSRD Valid discharge - - -300 µV VSR + VOS (see note) VMCV Maximum single-cell voltage 2.20 2.25 2.30 V SB VBR - 0.1 0.25 V SB pulled low Battery removed/replaced 2.20 2.25 2.30 V SB pulled high Note: Parameter Notes Default value; value set in DMF register. VOS is affected by PC board layout. Proper layout guidelines should be followed for optimal performance. See “LayoutConsiderations.” 15 Not Recommended For New Designs bq2010 DC Electrical Characteristics (TA = TOPR) Symbol VCC VREF Parameter Minimum Typical Maximum Unit Notes Supply voltage 3.0 4.25 6.5 V VCC excursion from < 2.0V to ≥ 3.0V initializes the unit. Reference at 25°C 5.7 6.0 6.3 V IREF = 5µA Reference at -40°C to +85°C 4.5 - 7.5 V IREF = 5µA RREF Reference input impedance 2.0 5.0 - MΩ VREF = 3V - 90 135 µA VCC = 3.0V, DQ = 0 ICC Normal operation - 120 180 µA VCC = 4.25V, DQ = 0 - 170 250 µA VCC = 6.5V, DQ = 0 VSB Battery input 0 - VCC V RSBmax SB input impedance 10 - - MΩ IDISP DISP input leakage - - 5 µA VDISP = VSS ILCOM LCOM input leakage -0.2 - 0.2 µA DISP = VCC RDQ Internal pulldown 500 - - KΩ VSR Sense resistor input -0.3 - 2.0 V RSR SR input impedance VIH Logic input high VIL Logic input low VIZ Logic input Z VOLSL 10 - - MΩ VCC - 0.2 - - V 0 < VSB < VCC VSR < VSS = discharge; VSR > VSS = charge -200mV < VSR < VCC PROG1–PROG6 - - VSS + 0.2 V PROG1–PROG6 float - float V PROG1–PROG6 SEGX output low, low VCC - 0.1 - V VCC = 3V, IOLS ≤ 1.75mA SEG1–SEG6 VOLSH SEGX output low, high VCC - 0.4 - V VCC = 6.5V, IOLS ≤ 11.0mA SEG1–SEG6 VOHLCL LCOM output high, low VCC VCC - 0.3 - - V VCC = 3V, IOHLCOM = -5.25mA VOHLCH LCOM output high, high VCC VCC - 0.6 - - V VCC = 6.5V, IOHLCOM = -33.0mA IIH PROG1-6 input high current - 1.2 - µA IIL PROG1-6 input low current - 1.2 - µA VPROG = VCC/2 At VOHLCH = VCC - 0.6V IOHLCOM LCOM source current IOLS SEGX sink current VPROG = VCC/2 -33 - - mA - - 11.0 mA At VOLSH = 0.4V At VOL = VSS + 0.3V DQ, EMPTY IOL Open-drain sink current - - 5.0 mA VOL Open-drain output low - - 0.5 V IOL ≤ 5mA, DQ, EMPTY VIHDQ DQ input high 2.5 - - V DQ VILDQ DQ input low - - 0.8 V DQ RPROG Soft pull-up or pull-down resistor value (for programming) - - 200 KΩ PROG1–PROG6 RFLOAT Float state external impedance - 5 - MΩ PROG1–PROG6 16 Not Recommended For New Designs bq2010 Serial Communication Timing Specification (TA = TOPR) Symbol Parameter Minimum Typical Maximum Unit tCYCH Cycle time, host to bq2010 3 - - ms tCYCB Cycle time, bq2010 to host 3 - 6 ms tSTRH Start hold, host to bq2010 5 - - ns tSTRB Start hold, bq2010 to host 500 - - µs tDSU Data setup - - 750 µs tDH Data hold 750 - - µs tDV Data valid 1.50 - - ms tSSU Stop setup - - 2.25 ms tSH Stop hold 700 - - µs tSV Stop valid 2.95 - - ms tB Break 3 - - ms tBR Break recovery 1 - - ms Note: Notes See note The open-drain DQ pin should be pulled to at least VCC by the host system for proper DQ operation. DQ may be left floating if the serial interface is not used. Serial Communication Timing Illustration DQ (R/W 1 ) V V DQ (R/W 0 ) V V tSTRH tSTRB tDH tDSU tDV DQ (BREAK) tSSU tSV tCYCH, tCYCB, tB tSH tBR TD201002.eps 17 Not Recommended For New Designs bq2010 16-Pin SOIC Narrow (SN) 16-Pin SN (SOIC Narrow) D e Dimension Minimum A 0.060 A1 0.004 B 0.013 C 0.007 D 0.385 E 0.150 e 0.045 H 0.225 L 0.015 All dimensions are in inches. B E H A C A1 .004 L 18 Maximum 0.070 0.010 0.020 0.010 0.400 0.160 0.055 0.245 0.035 Not Recommended For New Designs bq2010 Data Sheet Revision History Change No. Page No. Description 3 4 EDV monitoring 3 6 Table 1, PROG5 3 7,8 Self-discharge 3 11 Capacity inaccurate Nature of Change Was: EDV monitoring is disabled if VSR ≤ -150mV; Is: EDV monitoring is disabled if VSR ≤ -250mV Was: PROG5 = H = Reserved; Is: PROG5 = H = Disable self-discharge Add: or disabled as selected by PROG5 Correction: CI is asserted on the 64th charge after the last LMD update or when the bq2010 is reset 3 13 Nominal available charge register NACL stops counting when NACH reaches zero Was: 3 13 Overload flag Is: Notes: Changes 1 and 2; please refer to the 1995 Data Book. Change 3 = Apr. 1995 D changes from Mar. 1994 C. VSR < -150mV VSR < -250mV Ordering Information bq2010 Temperature Range: blank = Commercial (0 to +70°C) Package Option: SN = 16-pin narrow SOIC Device: bq2010 Gas Gauge IC 19 PACKAGE OPTION ADDENDUM www.ti.com 4-Sep-2015 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (°C) Device Marking (4/5) BQ2010SN-D107 NRND SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR 0 to 70 2010 D107 BQ2010SN-D107G4 NRND SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR 0 to 70 2010 D107 BQ2010SN-D107TR NRND SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR 0 to 70 2010 D107 BQ2010SN-D107TRG4 NRND SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR 0 to 70 2010 D107 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 4-Sep-2015 Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 TAPE AND REEL INFORMATION *All dimensions are nominal Device BQ2010SN-D107TR Package Package Pins Type Drawing SOIC D 16 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) 2500 330.0 16.4 Pack Materials-Page 1 6.5 B0 (mm) K0 (mm) P1 (mm) 10.3 2.1 8.0 W Pin1 (mm) Quadrant 16.0 Q1 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) BQ2010SN-D107TR SOIC D 16 2500 367.0 367.0 38.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2015, Texas Instruments Incorporated