MIW3000 Series 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters Key Features y y y y y y y y y y Efficiency up to 86% 1500VDC Isolation MTBF > 1,000,000 Hours 2:1 Wide Input Range UL1950 Safety Approval Complies with EN55022 Class A Temperature Performance -40] to +71] Industry Standard Pinout UL 94V-0 Package Material Internal SMD Construction Minmax's MIW3000-Series Power modules are low-profile dc-dc converters that operate over input voltage ranges of 4.5-7VDC, High Power Density 9-18VDC, 18-36VDC and 36-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC. The -40] to +71] operating temperature range makes it ideal for More Power data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. 1500 VDC The modules have a maximum power rating of 6W and a typical full-load efficiency of 86%, continuous short circuit, 50mA output ripple, EN55022 Class A conducted noise compliance minimize design-in time, I/O Isolation cost and eliminate the need for external filtering. EMI 2:1 EN55022 Wide Range Block Diagram Single Output +Vin Dual Output +Vo LC Filter +Vin +Vo LC Filter Com. -Vo -Vin 1 PFM Isolation Ref.Amp -Vo -Vin MINMAX PFM Isolation Ref.Amp REV:0 2005/04 MIW3000 Series Model Selection Guide Model Number Input Voltage Output Voltage VDC VDC 3.3 5 12 15 {5 {12 {15 3.3 Max. mA 1200 1000 500 400 {500 {250 {200 1200 Min. mA 60 50 25 20 {25 {12.5 {10 60 @Max. Load mA (Typ.) 1056 1265 1463 1463 1265 1463 1463 429 MIW3022 5 1000 50 514 MIW3023 12 500 25 595 15 400 20 595 {5 {500 {25 514 81 MIW3026 {12 {250 {12.5 595 84 MIW3027 {15 {200 {10 595 84 MIW3031 3.3 1200 60 209 79 MIW3032 5 1000 50 251 83 MIW3033 12 500 25 291 86 MIW3011 MIW3012 MIW3013 MIW3014 MIW3015 MIW3016 MIW3017 MIW3021 5 (4.5 ~ 7 ) 12 ( 9 ~ 18 ) MIW3024 MIW3025 MIW3034 24 ( 18 ~ 36 ) Output Current Input Current @No Load mA (Typ.) Reflected Ripple Current mA (Typ.) 70 100 Efficiency @Max. Load % (Typ.) 75 79 82 82 79 82 82 77 81 84 20 15 400 20 291 {500 {25 251 83 MIW3036 {12 {250 {12.5 291 86 MIW3037 {15 {200 {10 291 86 MIW3041 3.3 1200 60 104 79 MIW3042 5 1000 50 126 83 MIW3043 12 500 25 145 15 400 20 145 {5 {500 {25 126 83 MIW3046 {12 {250 {12.5 145 86 MIW3047 {15 {200 {10 145 86 MIW3044 MIW3045 48 ( 36 ~ 75 ) Absolute Maximum Ratings Parameter Min. Max. Unit 5VDC Input Models 12VDC Input Models Input Surge Voltage ( 1000 mS ) 24VDC Input Models 48VDC Input Models Lead Temperature (1.5mm from case for 10 Sec.) Internal Power Dissipation -0.7 -0.7 -0.7 -0.7 ----- 10 25 50 100 260 2,500 VDC VDC VDC VDC ] mW Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. Environmental Specifications Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conducted EMI REV:0 2005/04 Conditions Ambient Case Min. Max. -40 +71 -40 +90 -40 +125 --95 Free-Air Convection EN55022 Class A Unit ] ] ] % MINMAX 15 84 {5 MIW3035 5 25 86 86 3 10 86 Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. 2 MIW3000 Series Input Specifications Parameter Start Voltage Model Under Voltage Shutdown Typ. Max. 4.4 5V Input Models 3 3.5 12V Input Models 4.5 6 8 24V Input Models 8 12 16 Unit 48V Input Models 16 24 32 5V Input Models --- --- 4 12V Input Models --- --- 8 24V Input Models --- --- 16 48V Input Models --- --- 32 --- --- 1 A --- 1000 3000 mW Reverse Polarity Input Current Short Circuit Input Power Min. All Models Input Filter VDC Pi Filter Output Specifications Parameter Conditions Min. Typ. Max. Unit --- {0.5 {1.0 % Dual Output, Balanced Loads --- {0.5 {2.0 % Line Regulation Vin=Min. to Max. --- {0.1 {0.3 % Load Regulation Io=20% to 100% --- {0.3 {1.0 % --- 50 75 mV P-P Output Voltage Accuracy Output Voltage Balance Ripple & Noise (20MHz) --- --- 100 mV P-P Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Line, Load & Temp. --- --- 15 mV rms Over Power Protection 120 --- --- % Transient Recovery Time --- 150 300 uS 25% Load Step Change Transient Response Deviation Temperature Coefficient Output Short Circuit --- {2 {6 % --- {0.01 {0.02 %/] Continuous General Specifications Parameter Conditions Min. Typ. Max. Unit Isolation Voltage Rated 60 Seconds 1500 --- --- VDC Isolation Voltage Test Flash Tested for 1 Second 1650 --- --- VDC Isolation Resistance 500VDC 1000 --- --- M[ Isolation Capacitance 100KHz,1V --- 380 500 pF --- 300 --- KHz 1,000 --- --- K Hours Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Capacitive Load Models by Vout 3.3V 5V 12V 15V {5V # {12V # {15V # Unit Maximum Capacitive Load 6800 6800 6800 6800 1000 1000 1000 uF # For each output 3 MINMAX REV:0 2005/04 MIW3000 Series Input Fuse Selection Guide 5V Input Models 12V Input Models 24V Input Models 48V Input Models 3000mA Slow - Blow Type 1500mA Slow - Blow Type 700mA Slow - Blow Type 350mA Slow - Blow Type Input Voltage Transient Rating 150 140 130 120 48VDC Input Models 110 Vin ( VDC ) 100 90 80 70 24VDC Input Models 60 50 40 12VDC Input Models 30 20 5VDC Input Models 10 0 10uS REV:0 2005/04 100uS 1mS MINMAX 10mS 100mS 4 100 100 90 90 Efficiency (%) Efficiency (%) MIW3000 Series 80 70 60 80 70 60 50 Low Nom 50 High Low Nom Input Voltage (V) Efficiency vs Input Voltage ( Dual Output ) 90 90 80 80 70 70 Efficiency (%) Efficiency (%) Efficiency vs Input Voltage ( Single Output ) 60 50 60 50 40 40 30 30 20 10 20 40 High Input Voltage (V) 60 80 100 20 Load Current (%) 10 20 40 60 80 100 Load Current (%) Efficiency vs Output Load ( Single Output ) Efficiency vs Output Load ( Dual Output ) 100 100LFM 400LFM Natural convection 200LFM Output Power (%) 80 60 40 20 0 〜 -40 50 60 70 80 Ambient Temperature 90 100 110 ] Derating Curve 5 MINMAX REV:0 2005/04 MIW3000 Series Test Configurations Overcurrent Protection Input Reflected-Ripple Current Test Setup To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + Battery +Vin Lin Cin -Vin The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. +Out DC / DC Converter Current Probe Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Single Output DC / DC Converter -Vin Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 10uF for the 5V input devices, a 3.3uF for the 12V input devices and a 2.2uF for the 24V and 48V devices. + DC Power Source Copper Strip Cout Input Source Impedance Scope +Vin + DC / DC Converter Load Cin - Resistive Load +Out -Vin -Out -Out Output Ripple Reduction +Vin +Out Dual Output DC / DC Converter Com. -Vin -Out A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. Copper Strip Cout Scope Cout Scope Resistive Load + Maximum Capacitive Load The MIW3000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 1000uF maximum capacitive load for dual outputs and 6800uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. - -Vin + +Vin MINMAX Cout -Vin Load -Out +Out Dual Output DC / DC Com. Converter DC Power Source - +Out Single Output DC / DC Converter DC Power Source Design & Feature Considerations REV:0 2005/04 +Vin -Out Cout Load 6 MIW3000 Series Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90°C. The derating curves are determined from measurements obtained in an experimental apparatus. Position of air velocity probe and thermocouple 15mm / 0.6in 7 50mm / 2in Air Flow DUT MINMAX REV:0 2005/04 MIW3000 Series Mechanical Dimensions Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) Single Output 10.2 [0.40] Side 4.5 [0.18] 2 3 9 11 16 14 Bottom 23 22 Tolerance Pin Millimeters Inches X.X{0.25 X.XX{0.01 X.XX{0.13 {0.05 X.XXX{0.005 {0.002 Dual Output 20.3 [0.80] 2.54 [0.100] 2.5 [0.10] 0.50 [0.020] 15.22 [0.600] 4.1 [0.16] 31.8 [1.25] Pin Connections Physical Characteristics Pin Single Output Dual Output 2 -Vin -Vin 3 -Vin -Vin 9 No Pin Common 11 NC -Vout 14 +Vout +Vout 16 -Vout Common 22 +Vin +Vin 23 +Vin +Vin 31.8*20.3*10.2 mm Case Size : Case Material : Metal With Non-Conductive Baseplate Weight : 16.9g Flammability : UL94V-0 1.25*0.80*0.40 inches NC: No Connection The MIW3000 converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. REV:0 2005/04 MINMAX 8