Rectron FM203L Surface mount glass passivated silicon rectifier voltage range 50 to 1000 volts current 2.0 ampere Datasheet

FM201L
THRU
FM207L
SURFACE MOUNT
GLASS PASSIVATED SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 2.0 Ampere
FEATURES
*
*
*
*
*
*
Glass passivated device
Ideal for surface mounted applications
Low leakage current
Metallurgically bonded construction
Mounting position: Any
Weight: 0.098 gram
SMBL
MECHANICAL DATA
* Epoxy : Device has UL flammability classification 94V-0
0.083 (2.11)
0.077 (1.96)
0.155 (3.94)
0.130 (3.30)
0.180 (4.57)
0.160 (4.06)
0.012 (0.305)
0.006 (0.152)
0.085 (2.15)
0.061 (1.55)
0.060 (1.52)
0.030 (0.76)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.008 (0.203)
0.004 (0.102)
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
0.220 (5.59)
0.205 (5.21)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
FM201L
FM202L
FM203L
FM204L
FM205L
FM206L
FM207L
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Ambient Temperature
IO
2.0
Amps
I FSM
50
Amps
Typical Thermal Resistance (Note 1)
RqJA
53
0
C/W
Typical Thermal Resistance (Note 1)
RqJL
16
0
C/W
Typical Junction Capacitance (Note 2)
CJ
30
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Storage Temperature Range
pF
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 2.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
SYMBOL
FM201L
VF
IR
NOTES : 1. Thermal Resistance :Mounted on PCB.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant","100% Sn plating (Pb-free)".
FM202L
FM203L
FM204L
FM205L
FM206L
FM207L
UNITS
1.1
Volts
5.0
mA
125
mA
2006-11
2.0
1.5
1.0
Single Phase Half Wave 60Hz
Resistive or Inductive Load
0.375" (9.5mm) Lead Length
0.5
0
0
25
50
75
100
125
150
175
1000
INSTANTANEOUS FORWARD CURRENT, (mA)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( FM201L THRU FM207L )
TA = 100 OC
100
10
1.0
TA = 75 OC
TA = 25 OC
0.1
0.01
0
20
O
CJ, JUNCTION CAPACITANCE, (pF)
20
10
1.0
0.1
TJ = 25 OC
Pulse width=300mS
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
40
60
100
120
140
4.0
4.5
400
TJ = 25 OC
200
100
80
60
40
20
10
5.0
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.0
4
10
40 80
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.4 TYPICAL JUNCTION CAPACITANCE
60
8.3mS Single Half Sine-Wave
JEDEC Method
50
40
30
20
10
1
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
AMBIENT TEMPERATURE, ( C)
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Mounting Pad Layout
0.106 MAX.
(2.69 MAX.)
0.083MIN.
( 2.10 MIN.)
0.050 MAX.
(1.27 MAX.)
0.220
(5.58) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
Similar pages