Series AM30K-Z 30 Watt | DC-DC Converter FEATURES: • • • • Models: Single output Model Input – Voltage (V) AM30K-1203SZ AM30K-1205SZ AM30K-1212SZ AM30K-1215SZ AM30K-2403SZ AM30K-2405SZ AM30K-2412SZ AM30K-2415SZ AM30K-4803SZ AM30K-4805SZ AM30K-4812SZ AM30K-4815SZ 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 Models: Dual output Model Input – Voltage (V) AM30K-1212DZ AM30K-1215DZ AM30K-2412DZ AM30K-2415DZ AM30K-4812DZ AM30K-4815DZ 9-18 9-18 18-36 18-36 36-75 36-75 Wide Input 2:1 Range Full SMD Technology 1500 VDC Isolation Efficiency up to 91% • • • • Adjustable Output Voltage Remote ON/OFF Function Over Current, Voltage, & Temperature Protection Soft Start Output Voltage (V) Output Current max (A) Isolation (VDC) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 5.5 5.0 2.5 2.0 5.5 5.0 2.5 2.0 5.5 5.0 2.5 2.0 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 Output Voltage (V) Output Current max (A) Isolation (VDC) ±1.25 ±1.0 ±1.25 ±1.0 ±1.25 ±1.0 1500 1500 1500 1500 1500 1500 ±12 ±15 ±12 ±15 ±12 ±15 Max Capacitive Load (uF) Efficiency (%) 15000 10000 2200 1000 15000 10000 2200 1000 15000 10000 2200 1000 83 86 90 90 84 87 91 91 84 87 91 91 Max Capacitive Load (uF) Efficiency (%) ±1000 ±680 ±1000 ±680 ±1000 ±680 90 90 91 91 90 90 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Input Specifications Voltage range Filter Start up time Absolute Maximum Rated Input Voltage Peak Input Voltage time On/Off Control Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R8.F Nominal 12 24 48 Typical 9-18 18-36 36-75 20 Maximum Units VDC π(Pi) Network ms 25 50 VDC 100 100 ms ON – high or open (2.5V TO 5.5V); OFF – low (-0.7V to 0.8V or short circuit between pin 2 & 3) 12 24 48 Conditions 3 sec Typical 1000 1200 Tel: +1 514 620 2722 1 of 4 Rated 1500 Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Output Specifications Output Specifications Voltage accuracy Voltage balance (Dual Output model) Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation (Single) Line voltage regulation (Dual) Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range General Specifications Input Specifications Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Over Temperature Protection Case material Weight Dimensions (L X W X H) MTBF Conditions Typical ±5 ±5 125 120 Balanced Load HL-LL HL-LL 10% to 100% Load 10% to 100% Load At 20MHz Bandwidth Maximum Continuous Auto Recovery ±5 ±5 ±0.5 ±0.5 ±0.02 75 ±10 Conditions 100% load With drating above 60 oC (see graph below) Typical 270 Units % % % % % % % % %/oC m Vp-p % Maximum Units -40 to +85 -40 to +125 100 Free air convection 95 110 Nickel-coated Copper and Epoxy (UL94V-0 rated) 48 2.00 x1.60 x0.40 inches 50.80 x 40.60 x 10.20 mm >1000000 hrs Calculated using MIL-HDBK-217 F at +25 oC KHz o C o C % g Safety Specifications Standards Agency approvals Safety www.aimtec.com F 051e R8.F CE IEC/EN 60950-1 EN55022 Class A EN55022 Class A EN61000-4-2 Perf. Criteria B EN61000-4-3 Perf. Criteria A EN61000-4-4 Perf. Criteria B EN61000-4-5 Perf. Criteria B EN61000-4-6 Perf. Criteria A EN61000-4-8 Perf. Criteria A Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Pin Out Specifications +Vin -Vin On/Off Control No Pin +Vout -Vout Trim +Vin -Vin On/Off Control +Vout Com -Vout Trim 50.80 (2.00) 4 40.60 (1.60) 7.62 10.16 5.08 (0.30) (0.40) (0.20) 17.78 (0.70) Dimensions Dual Bottom View 3 6 7 Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) Ø 1.00 (0.04) 5.08 (0.20) 2.54 (0.10) 2 5 45.72 (1.80) Built-in Stand-offs to ease PCB Cleaning 10.16 (0.40) Printed Face 1 10.16 10.16 10.16 (0.40) (0.40) (0.40) Single 5.10 (0.20) 1 2 3 4 5 6 7 5.10 (0.20) Pin Trimming www.aimtec.com F 051e R8.F Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Derating Free Air Convection 60º C Output Power (%) 100 80 60 Safe Operating Area 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Control ON/OFF pin connection example: Note A: An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. The filter capacitor Aimtec suggests: 1000uF, 100V. Models AM30K-12XXXZ AM30K-24XXXZ AM30K-48XXXZ C1 330 μf, 100V 330 μf, 100V 330 μf, 100V L 12μH 12μH 12μH C2 100μ, 100V 100μ, 100V 100μ, 100V C3 N/A N/A 1000Pf, 2000V Note B: Input filter components (C1, C2, L) are used to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.F Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only