Keysight N6705B Dc power analyzer mainframe Datasheet

Keysight Technologies
N6700 Modular Power System Family
N6705B, N6715B DC Power Analyzer Mainframes
N6731B – N6786A DC Power Modules
14585A Control and Analysis Software
Data Sheet
2 | Keysight | N6700 Modular Power System Family - Data Sheet
R&D Engineers are Under Time Pressure
–– Ideal for R&D testing and design
validation
–– Sources and measures DC voltage and
current into your device under test
–– Combines one to four DC power
supplies, DMM, oscilloscope, arbitrary
waveform generator, and data logger
in one integrated instrument
–– Saves time – no programming
required
–– Eliminates the need to gather and
configure multiple instruments
–– Flexible, modular system: Lets you mix
and match DC source power levels
and measurement performance levels
to optimize your investment
–– Connect via GPIB, LAN, or USB
–– Fully compliant to LXI Class C
specification
Due to increasing time-to-market
pressures, research and development
engineers often find themselves on tight
schedules to work through device under
test (DUT) testing. Along with being driven
faster, the R&D engineers can face a high
regret factor should their haste result in
damaging scarce, complex’ or expensive
DUTs during product development. This
is a particular concern when tests involve
applying DC power to a DUT. Furthermore,
test complexity increases when testing
devices that require multiple input
voltages, such as printed circuit boards.
Today, when performing DC power-related
tests, R&D engineers must gather and
configure multiple instruments to
complete DC sourcing and measurement
tasks. When executing these complex
tasks, which can involve simultaneously
connecting to and physically interacting
with multiple test instruments, the risk
of error increases. In response, R&D
engineers may choose to automate tests
that are too complex to do manually.
Unfortunately, while automating tasks
reduces human error, writing and debugging programs adds more work to already
overloaded R&D engineers.
The Keysight Technologies, Inc. N6705 DC
Power Analyzer represents an entirely new
instrument category for R&D engineers.
It provides unrivaled productivity gains
when sourcing and measuring DC voltage
and current into a DUT. Using the Keysight
N6705 DC Power Analyzer, R&D engineers
can gain insights into the DUT’s power
consumption in minutes without writing a
single line of code. It provides an easyto-use interface, with all sourcing and
measuring functions available from the
front panel.
3 | Keysight | N6700 Modular Power System Family - Data Sheet
New Instrument Category for R&D Engineers to Increase Productivity
The Keysight N6705 DC power
analyzer saves time
–– Provides unrivaled productivity gains
for sourcing and measuring DC
voltage and current into your DUT
by integrating up to four advanced
power supplies with DMM, scope,
arbitrary waveform, and data logger
features.
–– Eliminates the need to gather multiple
pieces of equipment, create complex
test setups including transducers
(such as current probes and shunts)
to measure current into your DUT.
–– Eliminates the need to develop
and debug programs to control a
collection of instruments and take
useful measurements because all
the functions and measurements are
available at the front panel.
The Keysight N6705 DC power
analyzer makes these tasks
easy, right from the front panel
–– Setup and view critical turn-on/turnoff sequences.
–– Measure and display voltage,
current versus time to visualize power
into the DUT.
–– Control DC bias supply ramp-up/
down rates.
–– Generate DC bias supply transients
and disturbances (arbs).
–– Log data for seconds, minutes, hours,
or even days to see current/power
consumption or capture anomalies.
–– Save data and screen shots to
internal storage or external USB
memory devices.
–– Save and name your setup and tests
for easy re-use.
–– Share setups with colleagues.
The Keysight 14585A control
and analysis software saves
even more time
The 14585A control and analysis software
is a companion PC application that lets
you control any of the N6700 family’s DC
power modules when installed in up to
four N6705 mainframes – from a single
PC control screen. With this software, you
get improved data visualization and data
management.
–– Compliments the N6705 DC power
analyzer’s front panel controls.
–– Control and analyze data from up
to four N6705 DC power analyzer
mainframes and any installed modules
at once – up to 16 power modules
simultaneously.
–– Easily create complex waveforms to
simulate or load down a DUT by inputting a formula, choosing from built-in,
or importing waveform data.
–– Enhanced control and analysis of data
with familiar PC controls and large
display.
–– Data log measurements directly to a
PC.
–– Perform statistical analysis of power
consumptions.
For more information, visit
www.keyight.com/find/14585.
4 | Keysight | N6700 Modular Power System Family - Data Sheet
Modular System Based on DC Power Supply Outputs
The Keysight N6705 DC power analyzer
is a modular system that can be tailored
to meet specific test needs. At the heart
of the DC power analyzer is the DC power
module. The Keysight N6705 DC power
analyzer is a mainframe that has four
slots to accept one to four DC power
modules. Each DC power module takes
one slot, except for the N6750 highperformance autoranging and N6760
precision power modules that are ≥ 300
W, which occupy two slots. This modular
design gives you the flexibility to mix and
match over thirty different DC power
modules to create a solution optimized to
meet specific test requirements.
R&D engineers can invest in highperformance outputs where speed and
accuracy are needed, or purchase basic
performance outputs for simple DC power
requirements. In the future, as your test
needs change, you can purchase different
modules and swap them into the DC
power analyzer, thus creating a solution
that protects your investment and grows
with you.
Each DC power module output is fully
isolated and floating from ground and
from each other.
Figure 2. DC power modules are easily
installed into the N6705 DC power
analyzer mainframe.
Figure 1. The Keysight N6705 DC power analyzer with 14585A software.
Feature
Benefit
Integrates capabilities of power supply
DMM, scope, arb, and data logger
Saves time by eliminating the need to find and
interconnect multiple instruments.
Provides synergistic functions not available from
separately connected instruments.
Large color graphics display
Fast, simple, quick, set-up and monitoring.
Ability to visualize results of multiple channels.
Connections and controls color-coded to the Fast set-up and control.
display
Confidence that you are configured and testing
correctly.
Intuitive, dedicated physical controls for
common functions
Fast set-up and control using a familiar interface,
with each instrument function behaving like its
standalone counterpart.
Access all capabilities without programming
Reduce 90% of the effort associated with set-up by
eliminating the need for a PC, drivers, and software.
The N6730, N6740, and N6770 Series of
basic DC power modules
50 W, 100 W, and 300 W;
up to 150 V, up to 20 A
The N6750 Series of high-performance,
autoranging DC power modules
50 W, 100 W, 300 W and 500 W;
up to 60 V, up to 50 A
The N6760 Series of precision DC power
modules
50 W, 100 W, 300 W and 500 W;
up to 60 V, up to 50 A
The N6780 Series of application-specific
power modules
Up to 80 W;
up to 20 V, up to ± 8 A
5 | Keysight | N6700 Modular Power System Family - Data Sheet
Voltmeter/Ammeter: Meter View
Each DC power module in the Keysight
N6705 DC power analyzer has a fully
integrated voltmeter and ammeter to
measure the actual voltage and current
being sourced out of the DC output into
the DUT. Because this voltmeter/ammeter
function is built in, it is easy to make
measurements without additional wires
or the added complexity of current sense
resistors or current shunts. The accuracy
of the voltage and current measurements
are based on the type of module that is
installed (basic, high-performance, precision, or SMU). You can find the accuracy
specification in the tables starting on page
17 under “Voltage Measurement Accuracy”
and “Current Measurement Accuracy.”*
*
Figure 3. In Meter View, all 4 outputs can be
viewed simultaneously. The both measured
values for voltage and current and setting for
voltage and current are displayed for each
output.
Complete specifications are available at http://literature.cdn.keysight.com/litweb/pdf/N6700-90001.pdf
Figure 4. In Meter View, you can also view
an enlarged view of one channel, displaying
many settings and measured values, for
that channel. A summary is shown for the
other three channels.
6 | Keysight | N6700 Modular Power System Family - Data Sheet
Oscilloscope: Scope View
Each DC power module in the Keysight
N6705 DC power analyzer has a fully
integrated digitizer to capture the actual
voltage-versus-time and current-versustime being sourced from the DC output
into the DUT. The digitized data appears
on the large color display just like an
oscilloscope. Because this oscilloscope
function is built in, it is possible to
make current measurements without
current sense resistors, current shunts,
or current probes. This greatly reduces
measurement setup complexity and
provides for accurate and fully specified,
calibrated measurements. The accuracy
of the measurements in oscilloscope
mode is based on the type of power
module installed (basic, high-performance
autoranging, precision, and SMU). You
can find this information in the Keysight
N6700 Modular Power System Family
Specifications Guide under “Oscilloscope
Measurement Accuracy.”*
The N6760 and N6780 SMU series
of power modules offer simultaneous
digitizing of output voltage and output
current, such that you can view a voltage
trace and a current trace at the same time
on the oscilloscope display. For all other
module types, you can select to view
either a voltage trace or a current trace on
the oscilloscope display.
Note that the measurement window is
determined by multiplying the selected
buffer size by the sample rate. For a
measurement window of 60 seconds for
example, with a buffer size set to 256 k
points, the fastest sample rate available
to you will be 234 microseconds. If the
buffer size is set to 64 k points, the
fastest available sample rate will be 937
microseconds.
Figure 5. In scope view, voltage and
current traces are displayed. In this
picture, the DC current flowing into the
DUT is clearly visible as a time-varying
waveform.
The table below shows the relationship
between the number of scope traces, the
sample rate, and the buffer size available
for each trace. As shown, the digitizer
can run at up to 200 kHz with up to 256
k samples per trace (512 k samples with
SCPI commands). With an effective
measurement bandwidth of up to 30 kHz,
this oscilloscope function is perfectly
matched to capture time varying events
on the DC output, such as peak current
demand, dropouts, rise times and other
DC transients and disturbances.
The measurement buffer size can be set to
between 1 k and 256 k points. Whatever
buffer size is selected, its available points
must be divided by the total number of
traces being measured.
The oscilloscope can be triggered on
either voltage or current levels. Because
the Keysight N6705 DC power analyzer
is an integrated instrument, the oscilloscope can also be easily configured
to trigger on the start of an arbitrary
waveform or to trigger when the DC
power output is enabled. For example, to
make an inrush current measurement on
your DUT, you can set the oscilloscope
to trigger on the DC output’s on/off key,
set the trigger mode to single shot, and
then turn on the DC output. This will
immediately capture the current flowing
out of the DC module into the DUT and
give a picture of the inrush current of
the DUT. This integrated functionality
is not available when using a collection
of separate test instruments on the test
bench and is an example of how the DC
power analyzer reduces setup time and
complexity.
Power module type
Number of traces
(1 trace = V or I)
Fastest sample rate Maximum buffer
size available per
trace
One N6780 SMU
1 trace
5.12 µs
(~ 200 kHz)
256 k points
Any power module
1 or 2 traces
10.24 µs
(~ 100 kHz)
128 k points
Any power module
3 or 4 traces
20.48 µs
(~ 50 kHz)
64 k points
* Complete specifications are available at http://literature.cdn.keysight.com/litweb/pdf/N6700-90001.pdf
7 | Keysight | N6700 Modular Power System Family - Data Sheet
Data Logger View
The Keysight N6705 DC power analyzer
can also function as a data logger. Using
the measurement capability built into
each DC power module, the N6705
can continuously log data to the large
color display and to a file. Data can be
simultaneously logged on all four DC
outputs. The accuracy of the voltage and
current measurements depends on the
type of module that is installed (basic,
high-performance, precision, and SMU).
The maximum data log file size is ~2 gigabytes, which is approximately one billion
readings. The data file can be stored on
the N6705’s internal non-volatile RAM or
saved externally on a USB memory device.
The data logger display can be saved
as a GIF file for use in reports. The
logged data can be saved for viewing
at a later time. Logged data can also
be exported to a CSV file that can be
read by most common data analysis
software packages.
As illustrated in the table below, there are
two modes of operation:
–– In standard mode, measurements are
spaced by the sample period, which is
programmable from
75 milliseconds to 60 seconds. For
each DC output, voltage measurements, current measurements, or
both can be logged. Each reading
is an integrated voltage or current
measurement. Standard mode data
logging is available on all DC power
module types.
–– In continuous sampling mode, the
built-in digitizer of the DC power
module runs continuously at 50,000
readings per second. You can specify
a sample period, which is the period
of time during which these continuous
readings will be accumulated. For
each sample period, one average
reading (and optionally, a minimum
and maximum value) is saved. In this
mode, the digitizer runs continuously as
the readings are averaged and stored;
therefore, the digitizer is always making
measurements and no data is missed.
The sample period is programmable
from 20 microseconds to 60 seconds. In
this mode, the N6760 and N6780 SMU
series of power modules offer simultaneous logging of output voltage and
output current. For all other module
types, you can log either voltage or
current when in continuous sampling
mode.
Figure 6. In Data Logger View, you can log
data on multiple traces. Here, the current
flowing out of output 1 and output 2 are
captured over 30 seconds.
Figure 7. To set up the data logger, use
a menu screen to select the operating
parameters. Setup screens like this are
used throughout the DC power analyzer.
Sample interval n
Standard
sample V + I
(@ 50 kHz)
Averaged Averaged
voltage for
5.12 ms
Continuous
sample V or I
(@ 50 kHz)
Sample interval n+1
wait
current for
5.12 ms
Averaged voltage OR current
for entire sample interval
wait
Averaged
voltage for
5.12 ms
Averaged
current for
5.12 ms
Averaged voltage OR current
for entire sample interval
Standard data logging
Continuous data logging
Sample interval
range
75 milliseconds to
60 seconds
20* microseconds to 60 seconds
* Add 20 µs for each additional parameter (Voltage,
Current, Min, or Max)
Sample rate:
50 kHz
200 kHz for N6780 SMU
50 kHz for all others
Data logging mode
used by N6705
Automatically selected when any N6730,
N6740, N6750, or
N6770 are set to
sample BOTH voltage
and current.
Automatically selected when any N6730, N6740,
N6750 or N6770 is set to measure either voltage
or current. Note that N6760 and N6780 SMU
modules can be set to sample BOTH.
8 | Keysight | N6700 Modular Power System Family - Data Sheet
Arbitrary Waveform Generator
Each DC power output on the Keysight
N6705 DC power analyzer can be
modulated by the module’s built-in
arbitrary waveform generator. This permits
the output to act as a DC bias transient
generator or power arbitrary waveform
generator. The maximum bandwidth
is based on the type of module that
is installed (basic, high-performance,
precision, and SMU). Refer to the Keysight
N6700 Modular Power System Family
Specifications Guide* for the bandwidth of
each DC power module.
The Keysight N6705 uses run length
encoding, where each point in the
waveform is defined by the voltage setting
and the dwell time or duration to stay at
that setting. Waveforms can be generated
by specifying only a small number of
points. For example, a pulse would only
take three points to define it.
The Keysight N6705 offers the following
waveform choices (see table below).
For example, to generate a pulse train of
10 identical pulses, you can program the
parameters for one pulse and then specify
that you want it to repeat 10 times.
For user-defined voltage and current
waveforms, you can download up to 512
setpoints of voltage or current. For each
setpoint, a dwell time is specified and
output will stay (i.e., dwell) at that setpoint
for the programmed dwell time value. For
each of the 512 setpoints in the user-defined waveform, you can have a different
dwell time from 0 to 262 seconds with 1
microsecond resolution. The module will
step through the user-defined table of
values, staying at each setpoint for the
programmed dwell time, and then it will
move on to the next point. User-defined
waveforms can be imported from a CSV
file or directly entered from the front panel
of the DC power analyzer.
Constant-dwell voltage or current
waveforms can also be generated, with up
to 64000 programmable points.
For each waveform, you can set it to
repeat continuously or you can specify the
number of times the waveform is repeated.
*
Figure 8. The Arb Selection menu is used
to select which pre-programmed waveform
will be applied to the output of the DC
power module. Each of the four outputs can
have a different waveform applied.
Arbitrary waveform (voltage or current)
Number of points per waveform
Sine
100 points
Step
2 points
Ramp
100 points
Pulse
3 points
Stepped ramp (or staircase)
Determined by the number of steps programmed
Exponential
100 points
Trapezoid
100 points
User-defined waveform
(where the output is a voltage or current
source)
Up to 512 points with point-by-point adjustable dwell
Constant-dwell waveform
Up to 64,000 points with programmable dwell (same
for all points)
Figure 9. Once you have selected a
waveform, you simply fill in the blanks to
describe the waveform.
Complete specifications are available at http://literature.cdn.keysight.com/litweb/pdf/N6700-90001.pdf
9 | Keysight | N6700 Modular Power System Family - Data Sheet
Additional Features
Output sequencing
Series and parallel operation
Each DC power module can be individually
set to turn on or turn off with a delay. By
adjusting the delay times and then commanding the Keysight N6705 to turn on,
you can set the Keysight N6705 modules
to sequence on in a particular order. The
same sequencing capability is available to
shut down the modules in particular order.
Delay times can be set from no delay to
one thousand seconds of delay in onemillisecond increments.
To increase available voltage and power
per output, identically rated outputs can be
operated directly in series. The maximum
series operation is 240 V. To increase the
available current and power per output,
identically rated outputs can be operated
directly in parallel. The maximum rated
parallel operation is 100 A per Keysight
N6705.
For applications that require more than four
DC power modules to be sequenced, this
output sequencing can be extended across
multiple Keysight N6705 mainframes. By
wiring the I/O ports on the rear panel of the
mainframes together, a pair of synchronization signals is sent between mainframes,
allowing the output sequences of each
mainframe to be synchronized.
This capability is also supported to link
Keysight N6705 output sequences with
outputs installed in N6700B, N6701A
and N6702A Low-Profile Modular Power
System mainframes. It is not supported on
the discontinued N6700A mainframe.
Programmable voltage slew
For some applications, like inrush limiting
or powering rate-sensitive devices, it is
necessary to slow down and control the
speed of the DC output to maintain a
specific voltage slew rate. The Keysight
N6705 provides programmable voltage
slew rate, so that you can easily control the
speed at which the output slews from one
voltage to another. You can set the speed
of a voltage change anywhere from its
maximum up/down programming speed to
its slowest change of up to 10 seconds.
Convenient front panel
connections
The N6705 uses 3-way binding posts on
the front panel for connection to the DUT.
The binding posts accept standard banana
plugs, bare wire, and spade-lug connectors. The binding posts are rated for 20 A
per post. To avoid setup and connection
errors, the binding posts are color-coded
to the control keys and the display. For
modules with outputs rated at greater than
20 A, such as the N6753A, high current
wires must be brought out through the
N6705’s rear panel.
The N6705B mainframe provides rear
panel access ports to route these wires.
If you have an N6705A mainframe, order
N6705U-057 to replace your rear panel.
4-wire sensing for improved
measurement accuracy
To improve the voltage measurement
accuracy and regulation of the DC
outputs, the Keysight N6705 DC power
analyzer offers 4-wire sensing capability,
also called remote sensing, on each of the
four outputs of the DC power analyzer.
4-wire remote sensing is useful when the
DUT draws high current and you want to
account for voltage drop in the power leads
to achieve tight regulation and high voltage
measurement accuracy.
Figure 10. The Output On/Off Delays screen
allows you to enter the delay times for each
output. A graphical representation of the
settings is shown
to visually confirm your choices.
To use 4-wire sensing in addition to your
power leads, you must connect two low
current sensing leads between the DUT
input terminals and 4-wire sense terminal
binding posts located on the front of the
N6705 mainframe. This permits the output
module to monitor and regulate its output
voltage directly at the DUT input terminals
instead of the N6705 front panel output
binding posts. It then automatically adjusts
its output voltage to compensate for
voltage drops across the resistance in the
power leads.
For convenience, switching between
2-wire mode (local sensing) and 4-wire
mode (remote sensing) is done via an
internal relay inside the N6705 DC power
analyzer, eliminating the need for shorting
bars or jumpers commonly found on other
bench power sources.
10 | Keysight | N6700 Modular Power System Family - Data Sheet
DC power modules offer low
noise outputs
Careful attention has been paid to this
design to ensure low normal mode noise
(ripple and peak-peak) as well as low
common mode noise. While all DC power
modules are switching power supplies, the
N6750 high-performance autoranging DC
power modules, the N6760 precision DC
power modules, and the N6780 Source
Measure Units are switching power supply
designs that outperform most linear power
supplies on the market.
DC power modules provide fast
voltage changes
When it comes to speed, the N6750
high-performance autoranging DC power
modules, the N6760 precision DC power
modules, and the N6780 Source Measure
Units achieve performance unlike a typical
DC power supply. Thanks to an active
down-programming circuit to rapidly pull
down the output when lowering the output
voltage, these power modules can rapidly
program both up and down in voltage.
Changing voltage from 0 V to 50 V, or 50 V
to 0 V for example, can be accomplished in
less than 1.5 milliseconds.
The N6750 high-performance autoranging DC power modules and the N6760
precision DC power modules give you even
more flexibility by providing autoranging
outputs. This autoranging capability
provides maximum output power at any
output voltage up to 60 V. This allows one
power supply to do the job of several power
supplies, because its operating range covers low voltage, high current as well as high
voltage, low current operating points. For
example, the N6755A high-performance,
autoranging DC module, rated at 20 V, 50
A, and 500 W can provide full power at:
10 V @ 50 A (= 500 W),
20 V @ 25 A (= 500 W),
15 V @ 33 A (= 500 W),
or anywhere in between.
Therefore, this 500 W autoranging power
supply, due to its extended
voltage and current range, can produce
voltage and current combinations in the
range of a 1000 W non-autoranging
power supply.
Note that for smaller voltage changes,
from 0 V to 5 V or 5 V to 0 V for example,
the programming speed is less than 200
microseconds. These output speeds
allow the N6750/60/80 to give maximum
system through-put when your test calls
for frequent changes in power supply
voltage settings.
Autoranging for flexibility
Figure 11. The Keysight N6705 DC power analyzer is a perfect size
for the bench.
11 | Keysight | N6700 Modular Power System Family - Data Sheet
Real time clock
DUT protection features
The Keysight N6705 DC power analyzer
has a built-in battery backed real time
clock. This allows for proper timestamping of logged data. It is also used to
tag files with correct creation dates.
Each Keysight N6705 DC power module
is protected against over-voltage, overcurrent, and over-temperature. A fault
condition in one module can be detected
within 10 microseconds by other modules
so that they can be quickly shut down to
avoid hazardous conditions on your DUT.
Front panel USB
The Keysight N6705 DC power analyzer
provides a convenient front panel USB
port designed exclusively for data storage
devices, such as USB memory devices or
USB hard drives. On devices connected to
this USB port, you can save test setups,
test results, and screen images. It is also an
easy way to move test setup files between
two N6705 DC power analyzers or test
results between the DC power analyzer and
a PC. You can also log data directly to the
USB device plugged into the front panel.
This extends the total storage capability of
the N6705.
Internal memory
The Keysight N6705 DC power analyzer
has 4 gigabytes of non-volatile storage.
This storage is shared between the four
DC outputs. It can be used for saving test
setups, test results, and screen images.
External USB storage is supported for
increased storage capacity to log data
longer.
Emergency stop
Should a hazardous situation occur
during testing, you can press the large
red emergency stop button on the front
panel of the Keysight N6705. Pressing this
easy-to-find button immediately removes
power from the DC outputs. However, any
data collection (such as a scope trace or
data log) that is running at the time will
continue to run. By doing so, the data you
were collecting is saved and you will get a
record of what was happening at the time
of the event that caused you to press the
emergency stop button. The measurements could aid in failure analysis, repair,
or debugging of the DUT.
Output disconnect and polarity
reversal relays
Figure 12. The N6705’s front panel USB port.
Modules in the Keysight N6705 can be
individually ordered with optional Output
Disconnect Relays (option 761) or Output
Disconnect/Polarity Reversal Relays
(option 760). See table on page 21 for
option 760 and 761 availability. All relays
are built into the module, so no additional
wiring is needed to incorporate the relay
function.
Although the plus and minus rail of the
output power mesh are physically disconnected from the output terminals with
options 760 and 761, a small AC network
is still connected across the plus and
minus output terminals. This AC network
is required for EMI compliance.
With option 761, Output Disconnect
Relays, an emergency condition or turning
the DC output off causes mechanical
relays disconnect both the plus and minus
side of the power supply, including the
sense leads.
With option 760, Output Disconnect/Polarity Reversal Relays, mechanical relays
switch the leads on both the plus and the
minus side of the power supply, including
the sense leads, resulting in a voltage
polarity reversal at the DUT. In addition
to polarity reversal, option 760 provides
the same output disconnect function as
option 761.
Note: Output current is limited on some
modules when option 760 Output Disconnect/Polarity Reversal Relays is installed.
See the “Available options” tables on page
21 for more information about maximum
current limitations with option 760.
Figure 13. The emergency stop button
shuts down all outputs immediately.
12 | Keysight | N6700 Modular Power System Family - Data Sheet
Triggering
Programming language
The Keysight N6705 DC power analyzer
has hardware trigger in/trigger out signals
which permit the Keysight N6705 to be
synchronized with other test equipment.
For example, when you turn on the outputs
of the Keysight N6705, it can generate a
trigger signal to start a measurement on
an RF power meter.
The Keysight N6705 supports SCPI (Standard Commands for Programmable Instruments). Note that the Keysight N6705’s
command set is compatible with the
N6700 modular power system for ATE, so
programs written for the Keysight N6700
will work on the Keysight N6705.
Connectivity
The Keysight N6705 DC power analyzer
comes standard with GPIB, USB 2.0, and
10/100 base-T ethernet LAN interfaces.
The Keysight N6705 is fully compliant with
the LXI class C specification.
Security
All non-volatile RAM data and settings
can be cleared from the front panel. For
customers who have security concerns
about USB access to internally stored
test data and setups, the Keysight N6705
also offers option AKY, which removes
the USB ports from the front and rear
of the Keysight N6705. When used in
systems running GPIB, the LAN and/or
USB interfaces can be disabled for extra
security.
Control from any browser
The Keysight N6705 can be controlled
via a standard web browser. The Keysight
N6705 contains a web server that provides
a webpage containing a graphical front
panel representation of the Keysight
N6705 front panel. The Web GUI operation
is identical to operating the real front
panel on the Keysight N6705 DC power
analyzer.
Drivers
For customers who wish to operate
the DC power analyzer under computer
control, the Keysight N6705 comes with
both VXIplug&play drivers and IVI-COM
drivers. LabView drivers are available at
NI.COM.
Firmware updates
The Keysight N6705 firmware is stored in
FLASH ROM and can
be easily updated when new
features become available. Firmware can
be downloaded into the Keysight N6705
over GPIB, LAN, or USB
using the supplied firmware
update utility program. Firmware updates
can be found at
www.keysight.com/find/N6705firmware.
14585A control & analysis
software
Control up to four N6705
mainframes. For details visit
www.keysight.com/find/14585
13 | Keysight | N6700 Modular Power System Family - Data Sheet
Makes a great tool for ATE
systems that require an advanced
user interface for test and debug
Power management feature
allows you to allocate N6705
mainframe power
While the Keysight N6705 DC power
analyzer is designed primarily as an
R&D bench tool, customers building
ATE systems may find the Keysight
N6705 has great utility in an ATE
system. It is fully programmable, LXI
class C certified, and takes the same
commands as the Keysight N6700.
But thanks to its large display and
easy to use controls, test engineers
may find the Keysight N6705 makes
a great tool for visualizing test results
as the tests execute, for DUT troubleshooting, for DUT debugging, and f o
r ATE test development, The Keysight
N6705 mounts in a standard 19” rack
using standard rack mount hardware
for 4 U instruments.
Often, a DUT requires some high
power DC sources and several very
low power DC sources. In this case,
you may choose to configure a
system where the sum of the power
modules installed in the Keysight
N6705 exceeds the total power
available from the Keysight N6705
mainframe. The power management
features of the Keysight N6705
allow you to allocate mainframe
power to the outputs where it’s
needed, achieving maximum asset
utilization and flexibility. This feature
provides safety from unexpected and
dangerous shutdowns that can occur
with power systems without power
management when operated in a
similar way. For example, if your DUT
requires 250 W on two of its inputs, but
only 10 W each on two auxiliary inputs,
you can configure a system consisting of
two 300 W DC modules and two 50 W DC
modules. Although the sum of the module
power is greater than 600 W, you can
still use the Keysight N6705. Thanks to
the power management feature, you can
allocate the 250 W each to the two 300 W
modules while you allocate only 25 W to
each of the 50 W modules.
Universal AC input
The Keysight N6705 has a universal
input that operates from 100-240 VAC,
50/60/400 Hz. There are no switches to
set or fuses to change when switching
from one voltage standard to another. The
AC input employs power factor correction.
Achieve correlation and
share data between R&D and
manufacturing
The Keysight N6705 DC power
analyzer is a modular system that
uses the same DC power modules as
the N6700 low-profile modular power
system for ATE. Customers who use
the N6705 in R&D and the N6700
in manufacturing can easily achieve
test correlation between R&D testing,
design characterization/validation
testing, and manufacturing testing
because the DC power modules are
common to both the bench and ATE
versions of the product. Test programs
can be easily shared between R&D
and manufacturing since the Keysight
N6705 and the Keysight N6700 share
a common command set.
Figure 14. The Keysight N6705 can be installed in a standard 19 inch rack.
14 | Keysight | N6700 Modular Power System Family - Data Sheet
Choosing the Right DC Power Modules to Meet Your Testing Needs
N6730/40/70 basic series
Use the N6730/40/70 DC power
modules for basic applications –
Now with voltages up to 150 V
Not all testing requires high-performance
power supplies. When your budget is tight
and when speed and accuracy are a lower
consideration, the N6730 Series of 50 W
DC power modules, the N6740 Series of
100 W DC power modules, and the N6770
Series of 300 W DC power modules are an
economical solution that give you clean,
reliable DC power.
The N6730/40/70 series DC power
modules provide programmable voltage
and current, measurement and protection
features at a very economical price. These
power modules offer a wide range of
voltage, current, and power outputs. In
oscilloscope mode, they can be configured
to display either a voltage or a current
trace.
N6750 high-performance series
Use the N6750 DC power
modules for applications where
the power supply plays a critical
role – Now with available power
up to 500 W
The Keysight N6750 series of highperformance, autoranging DC power
modules provide low noise, high accuracy,
and output voltage changes that are up
to 10 to 50 times faster than other power
supplies. Additionally, autoranging output
capabilities enable one power supply to
do the job of several traditional power
supplies.
The N6750 series combine the widest
arbitrary waveform generator bandwidth,
available power up to 500 W, and highaccuracy measurements. In oscilloscope
mode, they can be configured to display
either a voltage or a current trace.
N6760 precision series
Use the N6760 DC power
modules for applications where
precision low-level performance
is required – Now with available
power up to 500 W
The N6760 precision DC power modules
provide dual ranges on both programming
and measurement. In the low range, these
power supplies provide 16-bit voltage and
current programming, and 18-bit measurements precision in the milliampere
and microampere region. They are ideally
suited for semiconductor and passive
device testing, or where a precisely
controlled output and highly accurate,
precise, measurements are needed during
test.
The N6760 precision DC power modules
also provide fast output changes for wide
arbitrary waveform generator bandwidth.
In oscilloscope mode, the precision
DC power modules offer the ability to
view both a voltage and a current trace
simultaneously.
N6780 SMU series
Use the N6780 source/measure
units for the most demanding
applications where multiquadrant operation and high
precision are required
The N6780 series of source/measure units
offer the highest level of performance in
the N6700 series. These SMUs feature
highly accurate measurements down to
nanoamperes, while providing operation as
a DC voltage source, DC current source,
and electronic load.
Figure 15. The basic series.
For details on these products and how
they can be used for applications including battery drain analysis and functional
test, visit www.keysight.com/find/N6780
and download the N6780 Series Source/
Measure Units (SMUs) for the N6700
Modular Power System Data Sheet,
literature number 5990-5829EN.
N6783 application-specific
series
For details on these products and how
they can be used for specific applications visit
www.keysight.com/find/N6783A-BAT
www.keysight.com/find/N6783A-MFG
and download the N6783A-BAT Data
Sheet, 5990-8662EN and the N6783AMFG Data Sheet, 5990-8643EN.
Figure 16. The N6750 high-performance
series and N6760 precision series DC power
modules that are ≥ 300 W each occupy two
modules slots within the mainframe. All
other modules occupy one module slot.
15 | Keysight | N6700 Modular Power System Family - Data Sheet
DC Power Module Feature Map
For detailed product specifications and characteristics, refer to the Keysight N6700 Modular Power System Family
Specifications Guide at http://literature.cdn.keysight.com/N6700-90001.pdf.
Feature
( = available)
DC power
N673xB, N674xB,
N677xA
High-performance
N675xA
Precision
N676xA
50 W output rating
N6731B – N6736B
N6751A
N6761A
100 W output rating
N6741B – N6746B
N6752A
N6762A
300 W output rating
N6773A – N6777A
N6753A, N6754A
N6763A, N6764A
500 W output rating
N6755A, N6756A
N6765A, N6766A
Output disconnect relays
Option 761
Option 761
Option 761
Output disconnect/polarity reversal relays
Option 760
Option 760
Option 760
Arbitrary waveform generation





Autoranging output capability
Voltage or current turn-on priority
N6761A, N6762A
Precision voltage and current measurements

Low voltage and current output ranges
N6761A, N6762A
Low voltage and current measurement ranges

200 µA measurement range (N6761A/N6762A only)
Voltage or current scope traces
Option 2UA



Simultaneous voltage and current scope traces

Simultaneous voltage and current data logging

Interleaved voltage and current data logging


Dynamic current correction

N6751A, N6752A
N6761A, N6762A
SCPI command list capability



SCPI command array readback



SCPI command programmable sample rate



SCPI command external data logging



N6753A – N6756A
N6763A – N6766A
Double-wide (occupies 2 channel locations)
16 | Keysight | N6700 Modular Power System Family - Data Sheet
DC Power Module Feature Map, continued
Feature
( = available)
Source/measure units (SMU)
Application-specific
N6781A
N6785A
N6782A
N6786A
N6784A
N6783A-BAT
N6783A-MFG
Output rating
20 W
80 W
20 W
80 W
20 W
24 W
18 W
2-quadrant operation






4-quadrant operation

Auxiliary voltage measurement input


Output disconnect relays





Option 761
Option 761
Arbitrary waveform generation







Negative voltage protection







Voltage or current priority mode





CC load/CV load





Battery emulator/charger





Voltage/current measurement only





Programmable output resistance


600 mV output range


300 mA output range








100 mA, 10 mA output ranges









1 V, 100 mV measurement ranges
100 mA, 1 mA, 10 μA measurement ranges
8 A, 100 mA, 1 mA measurement ranges





150 mA measurement range
Voltage or current scope traces





Simultaneous voltage and current scope
traces





Simultaneous voltage and current data
logging





Interleaved voltage and current data
logging
Seamless measurement autoranging




SCPI command list capability







SCPI command array readback







SCPI command programmable sample rate







SCPI command external data logging







SCPI command histogram measurements




17 | Keysight | N6700 Modular Power System Family - Data Sheet
DC Power Module Key Performance Specifications
Note: This data sheet does not include a comprehensive list of all power module specifications and characteristics.
Complete performance specifications and supplemental characteristics for all power modules can be found at
http://literature.cdn.keysight.com/litweb/pdf/N6700-90001.pdf. See the Keysight N6700 Modular Power System Family
Specifications Guide, part number N6700-90001.
DC output ratings
(volts/amps/watts)
Ripple & noise (p-p/
rms)
Voltage programming accuracy
Current programming accuracy
Voltage measurement accuracy
Current measurement accuracy
N6731B
5 V/10 A/50 W
10 mV/2 mV
0.1% + 19 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 20 mA
N6732B
8 V/6.25 A/50 W
12 mV/2 mV
0.1% + 19 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 10 mA
N6733B
20 V/2.5 A/50 W
14 mV/3 mV
0.1% + 20 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 5 mA
N6734B
35 V/1.5 A/52.5 W
15 mV/5 mV
0.1% + 35 mV
0.15% + 20 mA
0.1% + 35 mV
0.15% + 4 mA
N6735B
60 V/0.8 A/50 W
25 mV/9 mV
0.1% + 60 mV
0.15% + 20 mA
0.1% + 60 mV
0.15% + 4 mA
N6736B
100 V/0.5 A/50 W
30 mV/18 mV
0.1% + 100 mV
0.15% + 10 mA
0.1% + 100 mV
0.15% + 2 mA
N6741B
5 V/20 A/100 W
20 mV/2 mV
0.1% + 19 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 20 mA
N6742B
8 V/12.5 A/100 W
12 mV/2 mV
0.1% + 19 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 10 mA
N6743B
20 V/5 A/100 W
14 mV/3 mV
0.1% + 20 mV
0.15% + 20 mA
0.1% + 20 mV
0.15% + 5 mA
N6744B
35 V/3 A/105 W
15 mV/5 mV
0.1% + 35 mV
0.15% + 20 mA
0.1% + 35 mV
0.15% + 4 mA
N6745B
60 V/1.6 A/100 W
25 mV/9 mV
0.1% + 60 mV
0.15% + 20 mA
0.1% + 60 mV
0.15% + 4 mA
N6746B
100 V/1 A/100 W
30 mV/18 mV
0.1% + 100 mV
0.15% + 10 mA
0.1% + 100 mV
0.15% + 2 mA
N6751A
50 V/5 A/50 W
4.5 mV/0.35 mV
0.06% + 19 mV
0.1% + 20 mA
0.05% + 20 mV
0.1% + 4 mA
N6752A
50 V/10 A/100 W
4.5 mV/0.35 mV
0.06% + 19 mV
0.1% + 20 mA
0.05% + 20 mV
0.1% + 4 mA
N6753A
20 V/50 A/300 W
5 mV/1 mV
0.06% + 10 mV
0.1% + 30 mA
0.05% + 10 mV
0.1% + 30 mA
N6754A
60 V/20 A/300 W
6 mV/1 V
0.06% + 25 mV
0.1% + 12 mA
0.05% + 25 mV
0.1% + 8 mA
N6755A
20 V/50 A/500 W
5 mV/1 mV
0.06% + 10 mV
0.1% + 30 mA
0.05% + 10 mV
0.1% + 30 mA
N6756A
60 V/17 A/500 W
6 mV/1 V
0.06% + 25 mV
0.1% + 12 mA
0.05% + 25 mV
0.1% + 8 mA
N6761A 1
50 V/1.5 A/50 W
4.5 mV/0.35 mV
0.016% + 6 mV
0.04% + 0.2 mA
0.016% + 6 mV
0.04% + 0.16 mA
N6762A
1
50 V/3 A/100 W
4.5 mV/0.35 mV
0.016% + 6 mV
0.04% + 0.2 mA
0.016% + 6 mV
0.04% + 0.16 mA
N6763A
1
20 V/50 A/300 W
5 mV/1 mV
0.03% + 5 mV
0.1% + 15 mA
0.03% + 10 mV
0.1% + 10 mA
N6764A 1
60 V/20 A/300 W
6 mV/1 V
0.03% + 12 mV
0.1% + 15 mA
0.03% + 25 mV
0.1% + 5 mA
N6765A
1
20 V/50 A/500 W
5 mV/1 mV
0.03% + 5 mV
0.1% + 15 mA
0.03% + 10 mV
0.1% + 10 mA
N6766A 1
60 V/17 A/500 W
6 mV/1 V
0.03% + 12 mV
0.1% + 15 mA
0.03% + 25 mV
0.1% + 5 mA
N6773A
20 V/15 A/300 W
20 mV/3 mV
0.1% + 20 mV
0.15% + 60 mA
0.1% + 20 mV
0.15% + 15 mA
N6774A
35 V/8.5 A/300 W
22 mV/5 mV
0.1% + 35 mV
0.15% + 60 mA
0.1% + 35 mV
0.15% + 12 mA
N6775A
60 V/5 A/300 W
35 mV/9 mV
0.1% + 60 mV
0.15% +60 mA
0.1% + 60 mV
0.15% +12 mA
N6776A
100 V/3 A/300 W
45 mV/18 mV
0.1% + 100 mV
0.15% + 30 mA
0.1% + 100 mV
0.15% + 6 mA
N6777A
150 V/2 A/300 W
68 mV/27 mV
0.1% + 150 mV
0.15% + 30 mA
0.1% + 150 mV
0.15% + 6 mA
N6781A 1
20 V/± 3 A/20 W
12 mV/1.2 mV
0.025% + 1.8 mV
0.04% + 0.3 mA
0.025% + 1.2 mV
0.03% + 0.25 mA
N6782A
1
20 V/±3 A/20 W
12 mV/1.2 mV
0.025% + 1.8 mV
0.04% + 0.3 mA
0.025% + 1.2 mV
0.03% + 0.25 mA
N6784A
1
± 20 V/± 3 A/20 W
12 mV/1.2 mV
0.025% + 1.8 mV
0.04% + 0.3 mA
0.025% + 1.2 mV
0.03% + 0.25 mA
8 V/−2 A to 3 A/24 W
8 mV/1.5 mV
0.1% + 10 mV
0.1% + 1.8 mA
0.05% + 5 mV
0.1% + 0.6 mA
N6783A-BAT 2
N6783A-MFG
6 V/−2 A; 3 A/18 W
8 mV/1.5 mV
0.1% + 10 mV
0.1% + 1.8 mA
0.05% + 5 mV
0.1% + 0.6 mA
1
N6785A
20 V/+/-8A/80 W
15 mV/1.5 mV
0.025%+1.8 mV
0.04%+1.5 mA
0.025%+1.8 mV
0.04%+1.5 mA
N6786A1
20 V/+/-8A/80 W
15 mV/1.5 mV
0.025%+1.8 mV
0.04%+1.5mA
0.025%+1.8 mV
0.04%+1.5 mA
2
1
These power modules have multiple output and measurement ranges; values shown are for the highest range.
2
These power modules have multiple measurement ranges; values shown are for the highest range.
18 | Keysight | N6700 Modular Power System Family - Data Sheet
DC Power Analyzer Mainframe Key Characteristics
Interface capabilities
GPIB
SCPI – 1993, IEEE 488.2 compliant interface
LXI compliance
Class C
USB 2.0
Requires Keysight IO Library version M.01.01 or 14.0 and up
10/100 LAN
Requires Keysight IO Library version L.01.01 or 14.0 and up
Environmental conditions
Operating environment
Indoor use, installation category II (for AC input), pollution degree 2
Temperature range
0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature)
Relative humidity
Up to 95%
Altitude
Up to 2000 meters
AC input
Input ratings
~ 100 VAC – 240 VAC; 50/60/400 Hz
Power consumption
1440 VA
Power factor
0.99 @ nominal input and rated power
Net weight
N6705 with 4 modules (typical)
16 kg/35 lbs
Dimensions
Height/width/depth
194.7 mm/425.6 mm/313 mm
7.665 in./16.756 in./12.319 in.
19 | Keysight | N6700 Modular Power System Family - Data Sheet
Ordering Information
The DC power analyzer system
is available 2 ways
1. You can order an N6705B mainframe
and various modules as separate
products. (See steps below.) Each item
will arrive in a separate box so that you
can assemble the system yourself.
2. You can order an N6715B system,
which is a build-to-order DC power
analyzer system that is shipped as
a fully assembled multiple-output
power supply. (See pages 21 and 22 for
N6715B ordering information.
Mainframe
N6705B
DC power analyzer mainframe
Holds 1 to 4 modules.
Total available output power = 600 W
Available options to the N6705B mainframe
1CP005A
Rack mount kit
AKY
Delete front/rear USB
This option removes all USB capability from the DC power analyzer.
Both the front panel USB port and the rear panel USB port are removed.
055
Delete data logger
This option disables the data logger functionality in the DC power analyzer
firmware. The DC power analyzer hardware is unchanged. To enable the data
logger functionality at a later time, order the N6705U upgrade kit.
When ordering the DC power analyzer as
a mainframe and modules, follow these
steps.
056
Step 1
ABA
Full documentation on CD-ROM and printed users guide
Select the appropriate documentation and
line cord options.
900
Power cord, United Kingdom, P/N 8120-1351
901
Power cord, Australia, New Zealand, P/N 8120-1369
902
Power cord, Europe, Korea, P/N 8120-1689
903
Power cord, USA, Canada, 120 V, P/N 8120-4383
904
Power cord, USA, Canada, 240 V, P/N 8120-0698
906
Power cord, Switzerland, P/N 8120-2104
912
Power cord, Denmark, P/N 8120-2956
917
Power cord, South Africa, India, P/N 8120-4211
918
Power cord, Japan, 100 V, P/N 8120-5342
919
Power cord, Israel, P/N 8120-6800
920
Power cord, Argentina, P/N 8120-6869
921
Power cord, Chile, P/N 8120-6980
922
Power cord, China, P/N 8120-8376
927
Power cord, Thailand, Brazil, P/N 8120-8871
Step 2
Order 1 to 4 modules (see next page).
If the sum of the power of the modules
exceeds the available output power rating
on the mainframe, see page 13
for an explanation of Keysight’s power
management capability. Note that each
mainframe has 4 module slots to hold
modules. Each module occupies one module slot, except for the N6753A–N6756A
and N6763A–N6766A which occupy two
module slots.
Software license
This option provides a license to control one N6705 mainframe using the 14585A
Control & Analysis software.
Upgrade/retrofit kits
N6705U-001
Add data logger
This option activates the data logger functionality in the DC power analyzer
firmware. The DC power analyzer hardware is unchanged.
N6705U-056
Software license
This option provides a license to control one N6705 mainframe using the 14585A
Control & Analysis Software.
N6705U-057
Rear panel upgrade kit
This option upgrades the rear panel for an N6705A mainframe with the additional
access ports and measurement inputs that are on the N6705B mainframe.
For more information, visit www.keysight.com/find/N6705U
20 | Keysight | N6700 Modular Power System Family - Data Sheet
Ordering Information, continued
Modules
Order 1 to 4 modules to be installed in
each N6705B power analyzer mainframe.
(To order modules as part of the N6715B,
build-to-order systems, see page 22).
If the sum of the power of the modules
exceeds the available output power rating
on the mainframe, see page 13 for an
explanation of Keysight’s power management capability.
You can individually specify each option
for each module. For example, you can
order one module with Option 761 Output
Disconnect Relays while the remaining
modules have no relay options.
As your needs change and you want
to change configuration or add more
modules to existing N6705 mainframe,
use this ordering information to order the
required modules.
Modules
N6730 50 W
N6731B
DC power modules N6732B
5 V, 10 A, 50 W DC power module
8 V, 6.25 A, 50 W DC power module
N6733B
20 V, 2.5 A, 50 W DC power module
N6734B
35 V, 1.5 A, 50 W DC power module
N6735B
60 V, 0.8 A, 50 W DC power module
N6736B
100 V, 0.5 A, 50 W DC power module
N6740 100 W
N6741B
DC power modules N6742B
5 V, 20 A, 100 W DC power module
N6743B
20 V, 5 A, 100 W DC power module
N6744B
35 V, 3 A, 100 W DC power module
N6745B
60 V, 1.6 A, 100 W DC power module
N6750 highN6751A
performance,
auto-ranging
N6752A
DC power modules
50 V, 1.5 A, 50 W high-performance autoranging DC power
module
50 V, 1.5 A, 50 W high-performance autoranging DC power
module
N6753A
20 V, 50 A, 300 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6754A
60 V, 20 A, 300 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6755A
20 V, 50 A, 500 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6756A
60 V, 17 A, 500 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6760 precision
N6761A
DC power modules N6762A
50 V, 1.5 A, 50 W precision DC power module
50 V, 3 A, 100 W precision DC power module
N6763A
20 V, 50 A, 300 W precision DC power module (occupies 2 of 4
mainframe slots)
N6764A
60 V, 20 A, 300 W precision DC power module (occupies 2 of 4
mainframe slots)
N6765A
20 V, 50 A, 500 W precision DC power module (occupies 2 of 4
mainframe slots)
N6766A
60 V, 17 A, 500 W precision DC power module (occupies 2 of 4
mainframe slots)
N6770 300 W
N6773A
DC power modules N6774A
N6780 ~80 W
applicationspecific modules
8 V, 12.5 A, 100 W DC power module
20 V, 15 A, 300 W DC power module
35 V, 8.5 A, 300 W DC power module
N6775A
60 V, 5 A, 300 W DC power module
N6776A
100 V, 3 A, 300 W DC power module
N6777A
150 V, 2 A, 300 W DC power module
N6781A
20 V, ± 3 A, 20 W source/measure unit
N6782A
20 V, ± 3 A, 20 W source/measure unit
N6784A
± 20 V, ± 3 A, 20 W source/measure unit
N6783A-BAT
8 V, 3 A, 24 W battery charge/dischargemodule
N6783A-MFG
6 V, 3 A, 18 W mobile communications module
N6785A
20 V, +/-8A, 80 W source/measure unit
N6786A
20 V, +/-8A, 80 W source/measure unit
21 | Keysight | N6700 Modular Power System Family - Data Sheet
Ordering Information, continued
Available options to N6700 modules
N6731BN6736B
50 W
DC power
modules
N6741BN6746B
100 W
DC power
modules
N6751AN6756A
highperformance
autoranging
DC power
modules
N6761AN6766A
precision
DC power
modules
N6773AN6776A
300 W
DC power
modules
N6781A, N6782A,
N6784A
N6785A
N6786A
SMU modules
N6783A-BAT
N6783A-MFG
applicationspecific
Output disconnect
relays
761
761
761
761
761
Standard
761
Output disconnect and
polarity reversal relays
760
760 1, 2
760 1
760 1
760 2
Not available
Not available
200 microampere
measurement range
Not available
Not available
Not available
2UA 3
Not available
Not available
Not available
Commercial calibration
with test results data
UK6
UK6
UK6
UK6
UK6
UK6
UK6
ISO 17025 calibration
certificate
1A7
1A7
1A7
1A7
1A7
Not available
1A7
1. Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, N6762A.
2. Option 760 limits the output current to 10 A maximum on Models N6742B and N6773A.
3. Option 2UA is only available on Models N6761A and N6762A.
N6715B build-to-order system
To purchase a DC power analyzer, order an
N6715B. This model number is a buildto-order system that is shipped as a fully
tested and assembled instrument. Each
system consists of one mainframe plus
optionally 1 to 4 modules. Each mainframe
has 4 module slots to hold modules. Each
module occupies one module slot, except
for the N6753A – N6755A and the N6763A
– N6766A, which occupy two module
slots. To specify which modules you want
installed in the system, the modules are
ordered as options to the system model
number. You must order at least one
module.
Build-to-order system
N6715B
Build-to-order DC power analyzer system,
Consists of 1 N6705B mainframe with total available power of 600 W
Available options to the N6715B system
1CP005A
Rack mount kit
AKY
Delete front/rear USB
This option removes all USB capability from the DC power analyzer.
Both the front panel USB port and the rear panel USB port are removed.
056
Software license
This option provides a license to control one N6705 mainframe using the 14585A
Control & Analysis software.
ABA
Full documentation on CD-ROM and printed users guide
900
Power cord, United Kingdom, P/N 8120-1351
901
Power cord, Australia, New Zealand, P/N 8120-1369
If the sum of the power of the modules
exceeds the available output power rating
on the mainframe, see page 13 for an
explanation of Keysight’s power management capability.
902
Power cord, Europe, Korea, P/N 8120-1689
903
Power cord, USA, Canada, 120 V, P/N 8120-4383
904
Power cord, USA, Canada, 240 V, P/N 8120-0698
906
Power cord, Switzerland, P/N 8120-2104
If you prefer to purchase a DC power analyzer mainframe and modules as separate
pieces, see page 19.
912
Power cord, Denmark, P/N 8120-2956
917
Power cord, South Africa, India, P/N 8120-4211
918
Power cord, Japan, 100 V, P/N 8120-5342
919
Power cord, Israel, P/N 8120-6800
920
Power cord, Argentina, P/N 8120-6869
921
Power cord, Chile, P/N 8120-6980
922
Power cord, China, P/N 8120-8376
927
Power cord, Thailand, Brazil, P/N 8120-8871
22 | Keysight | N6700 Modular Power System Family - Data Sheet
Ordering Information, continued
Modules as options to N6715B
Module options for N6715B system
Order 1 to 4 modules as options to an
N6715B, specify its model number,
followed by “–ATO.” For example, to order
an N6731B as an option to the N6710B,
you would specify “–ATO.” For example,
to order an N6731B as an option to the
N6710B, you would specify “N6731B–
ATO”as the option. (To order modules as
separate products, see page 19). If the
sum of the power of the modules exceeds
the available output power rating on the
mainframe, see page 13 for an explanation of Keysight’s power management
capability.
N6730 50 W
DC power
modules
You can individually specify each option
for each module. For example, you can
order one module with Option 761 Output
Disconnect Relays while the remaining
modules have no relay options.
N6750 highperformance,
auto-ranging
DC power
modules
N6740 100 W
DC power
modules
N6760
precision
DC power
modules
N6770 300 W
DC power
modules
N6780 up to
80 W
applicationspecific
modules
N6731B-ATO
5 V, 10 A, 50 W DC power module
N6732B-ATO
8 V, 6.25 A, 50 W DC power module
N6733B-ATO
20 V, 2.5 A, 50 W DC power module
N6734B-ATO
35 V, 1.5 A, 50 W DC power module
N6735B-ATO
60 V, 0.8 A, 50 W DC power module
N6736B-ATO
100 V, 0.5 A, 50 W DC power module
N6741B-ATO
5 V, 20 A, 100 W DC power module
N6742B-ATO
8 V, 12.5 A, 100 W DC power module
N6743B-ATO
20 V, 5 A, 100 W DC power module
N6744B-ATO
35 V, 3 A, 100 W DC power module
N6745B-ATO
60 V, 1.6 A, 100 W DC power module
N6751A-ATO
50 V, 1.5 A, 50 W high-performance autoranging
DC power module
N6752A-ATO
50 V, 1.5 A, 50 W high-performance autoranging
DC power module
N6753A-ATO
20 V, 50 A, 300 W high-performance autoranging
DC power module (occupies 2 of 4 mainframe slots)
N6754A-ATO
60 V, 20 A, 300 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6755A-ATO
20 V, 50 A, 500 W high-performance autoranging DC power
module (occupies 2 of 4 mainframe slots)
N6756A-ATO
60 V, 17 A, 500 W high-performance autoranging
DC power module (occupies 2 of 4 mainframe slots)
N6761A-ATO
50 V, 1.5 A, 50 W precision DC power module
N6762A-ATO
50 V, 3 A, 100 W precision DC power module
N6763A-ATO
20 V, 50 A, 300 W precision DC power module (occupies 2 of 4
mainframe slots)
N6764A-ATO
60 V, 20 A, 300 W precision DC power module (occupies 2 of 4
mainframe slots)
N6765A-ATO
20 V, 50 A, 500 W precision DC power module (occupies 2 of 4
mainframe slots)
N6766A-ATO
60 V, 17 A, 500 W precision DC power module (occupies 2 of 4
mainframe slots)
N6773A-ATO
20 V, 15 A, 300 W DC power module
N6774A-ATO
5 V, 8.5 A, 300 W DC power module
N6775A-ATO
60 V, 5 A, 300 W DC power module
N6776A-ATO
100 V, 3 A, 300 W DC power module
N6777A-ATO
150 V, 2 A, 300 W DC power module
N6781A-ATO
20 V, ±3 A, 20 W source/measure unit
N6782A-ATO
20 V, ±3 A, 20 W source/measure unit
N6784A-ATO
± 20 V, ±3 A, 20 W source/measure unit
N6785A-ATO
20 V, ±8 A, 80 W source/measure unit
N6786A-ATO
20 V, ±8 A, 80 W source/measure unit
N6783A-BAT
8 V, 3 A, 24 W battery charge/discharge module
N6783A-MFG
6 V, 3 A, 18 W mobile communications module
23 | Keysight | N6700 Modular Power System Family - Data Sheet
Need a power solution for ATE?
The Keysight N6700 modular power
analyzer is small, flexible, and fast
–– Ideal for ATE systems in R&D, design
validation, and manufacturing
–– Small size: Up to 4 outputs in 1U of
rack space
–– Flexible, modular system: You can mix and match power levels and
performance levels to optimize your investment
–– Uses the same modules as the N6705 DC Power Analyzer
–– Fast command processing time to improve throughput
–– Connect via GPIB, LAN, or USB
–– Fully compliant to LXI Class C specification
Complete specifications can be found in the N6700 Modular Power System
Data Sheet, publication 5958-1411EN. For more information, go to
www.keysight.com/find/N6700
24 | Keysight | N6700 Modular Power System Family - Data Sheet
From Hewlett-Packard through Agilent to Keysight
For more than 75 years, we‘ve been helping you unlock measurement insights. Our
unique combination of hardware, software and people can help you reach your next
breakthrough. Unlocking measurement insights since 1939.
1939
THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
Keysight Infoline
www.keysight.com/find/service
Keysight’s insight to best in class information management. Free access to
your Keysight equipment company reports and e-library.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/n6705
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-02-10-16)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2012 - 2016
Published in USA, May 11, 2016
5989-6319EN
www.keysight.com