HGN-336 IEC 60320 INLET SOCKET WITH SWITCH, SNAP-IN MECHANICAL DIMENSIONS (Unit: mm) 33.0 40.0 16.0 +0.5 4.0 +0.2 4.0 +0.2 10A 250V 14.0+0.2 24.0+0.5 FEATURES The HGN-336 power entry module features an IEC Connector and a two-pole switch. The unit protects electronic equipment against malfunction due to fast common-mode and differential mode interferences. Designed for labor saving snap-in mounting. These filters are also available for Medical equipment with low leakage current. 57.0 3.0 41.5 APPLICATIONS Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. 6.30 TECHNICAL DATA • Rated Voltage: 115/250VAC • Rated Current: 1A, 2A, 3A, 4A, 6A, • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 250VAC 50Hz: 0.5mA, max @ 250VAC 50Hz: 2µA*, max • Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C * Medical application 0.8 A +0.2 30+0.2 36.5 +0.2 R1.5 TYP. RECOMMENDED PANEL CUTOUT Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords. 60 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com HGN-336 Series Example & Ordering Code HGN-336 - 1 = = = = = CURRENT RATING (A): SCHEMATIC: M - F - 150 1 2 3 4 6 STANDARD TYPE = WITHOUT C(Y); C(X) ONLY =M BLANK TERMINAL: =F QUICK CONNECT (6.3 x 0.8) PANEL THICKNESS*: = 150 = 160 = 200 0.06 (1.5MM) 0.062 (1.6MM) 0.08 (2.0MM) * More panel thickness options are available upon request Attenuation Tables & Schematics Non-Medical Applications Insertion loss in dB (50 Ohm circuit) 40 35 30 21 20 58 49 41 35 30 50 49 48 40 34 50 50 54 50 45 65 65 60 70 55 28 30 34 30 35 9 10 10 9 9 13 14 14 14 14 13 16 19 19 19 45 40 31 20 19 65 60 54 45 40 70 70 70 70 70 60 60 64 60 60 30 30 35 30 35 E N' 2200pF E' LOAD 30 25 20 14 10 Fuse 0.033 F 18 12 5 5 3 1M 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA L(mH) N 0.033 F 1A 2A 3A 4A 6A L Comm. Mode(L-G) MHz Diff. mode(L-L) MHz Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 LINE Current Rating 2200pF P Fuse L(mH) P' Medical Applications Insertion loss in dB (50 Ohm circuit) 32 30 28 18 13 41 38 33 23 19 51 40 38 30 27 48 42 38 32 29 37 36 30 32 29 31 30 23 30 29 22 21 18 22 25 9 9 9 9 9 11 11 15 13 18 15 11 14 19 21 50 42 38 19 19 67 67 55 44 47 82 82 82 82 84 71 75 76 79 82 37 38 35 40 50 E P 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com N' L(mH) E' LOAD 22 18 18 10 8 0.033 F 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA L(mH) N 0.033 F 1A 2A 3A 4A 6A Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 1M L Value LINE Current Rating P' 61