POWERDYNAMICS HGN-336-3M-F-150 Iec 60320 inlet socket with switch, snap-in Datasheet

HGN-336
IEC 60320 INLET SOCKET WITH SWITCH, SNAP-IN
MECHANICAL DIMENSIONS (Unit: mm)
33.0
40.0
16.0
+0.5
4.0 +0.2
4.0 +0.2
10A 250V
14.0+0.2
24.0+0.5
FEATURES
The HGN-336 power entry module features an IEC
Connector and a two-pole switch. The unit protects electronic
equipment against malfunction due to fast common-mode and
differential mode interferences. Designed for labor saving
snap-in mounting. These filters are also available for Medical
equipment with low leakage current.
57.0
3.0
41.5
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
6.30
TECHNICAL DATA
• Rated Voltage: 115/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A,
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
* Medical application
0.8
A +0.2
30+0.2
36.5 +0.2
R1.5 TYP.
RECOMMENDED
PANEL CUTOUT
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
60
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
HGN-336 Series Example & Ordering Code
HGN-336 - 1
=
=
=
=
=
CURRENT RATING (A):
SCHEMATIC:
M -
F
- 150
1
2
3
4
6
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
BLANK
TERMINAL:
=F
QUICK CONNECT (6.3 x 0.8)
PANEL THICKNESS*:
= 150
= 160
= 200
0.06 (1.5MM)
0.062 (1.6MM)
0.08 (2.0MM)
* More panel thickness options are available upon request
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
40
35
30
21
20
58
49
41
35
30
50
49
48
40
34
50
50
54
50
45
65
65
60
70
55
28
30
34
30
35
9
10
10
9
9
13
14
14
14
14
13
16
19
19
19
45
40
31
20
19
65
60
54
45
40
70
70
70
70
70
60
60
64
60
60
30
30
35
30
35
E
N'
2200pF
E'
LOAD
30
25
20
14
10
Fuse
0.033 F
18
12
5
5
3
1M
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
L(mH)
N
0.033 F
1A
2A
3A
4A
6A
L
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
LINE
Current
Rating
2200pF
P
Fuse
L(mH)
P'
Medical Applications
Insertion loss in dB (50 Ohm circuit)
32
30
28
18
13
41
38
33
23
19
51
40
38
30
27
48
42
38
32
29
37
36
30
32
29
31
30
23
30
29
22
21
18
22
25
9
9
9
9
9
11
11
15
13
18
15
11
14
19
21
50
42
38
19
19
67
67
55
44
47
82
82
82
82
84
71
75
76
79
82
37
38
35
40
50
E
P
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
N'
L(mH)
E'
LOAD
22
18
18
10
8
0.033 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
L(mH)
N
0.033 F
1A
2A
3A
4A
6A
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
1M
L
Value
LINE
Current
Rating
P'
61
Similar pages