H Series 50 Watt AC-DC Converters Input voltage range 85...255 V AC 1, 2 or 3 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage LGA • Rugged electrical and mechanical design • Output 1 regulated, outputs 2 and 3 tracking • Operating ambient temperature range –10...50°C with convection cooling Selection chart Output 1 Output 2 Output 3 Rated power Uo nom Io nom Uo nom Io nom Uo nom Io nom Po tot [V DC] 5.1 12 15 24 48 12 15 5.1 5.1 [A] 11 6 4.5 3 1.5 2 1.7 5 5 [V DC] 12 15 12 15 [A] 2 1.7 0.7 0.6 [V DC] 12 15 [A] 0.7 0.6 [W] 56 72 67 72 72 48 51 42 43 Type Input voltage 85...255 V AC LH 1001-2R LH 1301-2R LH 1501-2R LH 1601-2R LH 1901-2R LH 2320-2 LH 2540-2 LH 3020-2 LH 3040-2 Options D, V D D D D D D D, V D, V Input Input voltage Input frequency Inrush current limitation continuous range 85...255 V AC 47...63 Hz by thermistor Output Efficiency Output voltage 1 setting acc. Output voltage 2, 3 setting acc. Output voltage switching noise Line regulation Load regulation output 1 Load regulation output 2, 3 Output voltage 2, 3 Cross load regulation outp. 2, 3 Minimum output current Current limitation main output Current limitation aux. output(s) Operation in parallel Hold-up time www.power-one.com Edition 4/04.2001 Ui nom, Io nom Ui nom, Io nom Ui nom, Io nom IEC/EN 61204, total Ui min...Ui max, Io nom Ui nom, 0...Io1 nom 10...100% Io2,3 nom Ui nom, Io1 nom, Io2,3 = 0 0...100% Io1 nom not required rectangular U/I characteristic rectangular U/I characteristic by current limitation Ui = 230 V AC, Io nom up to 83% ±2% Uo1 nom ±5% Uo2,3 nom typ. 200 mVpp typ. ±1% Uo nom typ. 0.2% Uo1 nom typ. 0.7 V max. 115% Uo2,3 nom typ. 0.7 V 0A typ. 110% Io nom typ. 120% Io nom typ. 70 ms 1 Cassette Style H Series Protection Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature typ. 60 V AC typ. 280 V AC varistor no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart typ. 150% Uo nom TC typ. 100°C Control Output voltage adjustment Inhibit Status indication single output types TTL input, output(s) disabled if left open-circuit LEDs: OK, inhibit 0...110% Uo1 nom Safety Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA C22.2 No. 950 units without options I/case I/O O/case O/O class I IP 40 2 kV AC 4 kV AC 1 kV AC 0.2 kV AC IEC/EN 61000-4-2, contact discharge, level 2 (4 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, input, level 1 (0.5 kV) IEC/EN 61000-4-5, input, level 1 (0.5 kV) CISPR 22/EN 55022, conducted CISPR 22/EN 55022, radiated criterion A criterion A criterion A criterion A class A class B EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Electromagnetic emissions Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93 %, 40 °C IEC/EN 60068-2-6, 10…60/60…150 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 16 ms MIL-HDBK-217E, GB, 40 °C, single output types –10...50°C –10...80°C –25...100°C 21 days 0.15 mm/2 gn 15 gn 10 gn 384'000 h Options Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D www.power-one.com Edition 4/04.2001 D1…D8 V2, V3 2 H Series 50 Watt AC-DC Converters Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. 5 8 11 14 17 20 23 26 29 32 Measuring point for case temperature TC 68 22 (0.87") 173.7 (6.84") M 3; depth = 4 mm (chassis mount) 127 (5") 168.5 (6.63") 20 (0.79") 2TE 6TE S09050 2 European Projection 103 38.7 (1.52") 111.2 (3U) (4.38") OK Inhibit i www.power-one.com Edition 4/04.2001 Potentiometer (option D or V) 3 Cassette Style H Series Pin allocation Pin 2 5 8 11 14 17 14 17 20 23 Electrical Determination Inhibit control input Safe Data or ACFAIL Output voltage (positive) Output voltage (negative) Control input + Control input – Output voltage (positive) Output voltage (negative) Output voltage (positive) Output voltage (negative) 26 29 32 Protective earth AC input voltage AC input voltage LH1000 i D or V Vo1+ Vo1– R G Vo1+ Vo1– N P LH2000 i D or V LH3000 i D or V Vo3+ Vo3– Vo2+ Vo2– Vo1+ Vo1– Vo2+ Vo2– Vo1+ Vo1– N P N P Accessories Front panels 19" (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting 2/12.2000 www.power-one.com Edition 4/04.2001 4