Bel MAP140-3000P Universal input 85-264 vac Datasheet

Bel Power Solutions MAP140 Series provides a full range of options
and up to 30 watts more power than comparable products in this
industry-standard footprint. With a universal input from 85 to 264 VAC
and power densities up to 2.6 watts/inch3, the MAP140 meets the
most rigorous requirements of commercial, industrial, and datacom
systems.
Rated for use in convection and forced-air cooled (200 LFM)
applications, the MAP140 delivers dependable power with a Mean
Time Between Failures (MTBF) in excess of 180,000 hours.
In addition to UL, CSA, and NEMKO regulatory compliance, the
MAP140 displays the CE Mark.

RoHS Lead-Solder-Exemption Compliant

Universal Input 85-264 VAC

Input Transient & ESD Compliance to EN61000-4-2/-3/-4

CE marked to Low Voltage Directive

Industry-Standard Footprint: 7.0 x 4.3 x 1.8 inch
(177.8 x 109.2 x 45.7 mm)

Remote Sense and Overvoltage Protection

Power Fail Signal Standard on MAP140-3000P, Optional on MAP1401012 and MAP140-1024G

Optional Overtemperature Protection, L-bracket and Cover
MAP140 Series
2
MODEL5
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION
COOLED
CURRENT
FORCED
AIR
CURRENT 1
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE 2
INITIAL SETTING
ACCURACY
MAP140-1012*
12V/15V
11.0V to 16.0V
9.2/7.3A 3
12.5A/10A3
0.1%
0.5%
1%
11.97V to 12.03V
MAP140-1024G
24V/28V
22.8V to 29.2V
4.6/4A 3
6.3A/5.4A 3
0.1%
0.5%
1%
23.95V to 24.05V
MAP140-1048*
48V
45.6V to 54.0V
2.3A
3.1A
0.1%
0.5%
1%
47.9V to 48.1V
MODEL5
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT 4
PEAK
OUTPUT
CURRENT 4
LINE
REGULATION
LOAD
REGULATION
RIPPLE &
NOISE 2
+5V
4.75V to 5.25V
16A/25A PK
20A/25A PK
0.2%
1%
1%
+12V
Fixed
4A/9A PK
4A/9A PK
0.1%
2%
1%
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
2%
1%
MAP140-3000P*
INITIAL SETTING
ACCURACY
5.09V to
5.11V
11.97V to
12.03V
-11.4V to 12.6V
1
With minimum 200 LFM forced air cooling.
Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3 MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024G output currents are expressed as 24V/28V operation.
4 Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
5 Non-G models use lead solder exemption and are not recommended for new designs.
Oooooo Model numbers highlighted in yellow are not recommended for new designs.
* Obsolete
2
[email protected]
MAP140 Series
PARAMETER
CONDITIONS / DESCRIPTION
Input Voltage - AC
Continuous input range
Input Frequency
MAX
UNITS
85
264
VAC
AC input
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated
loads.
85
Hold-up Time
Nominal AC input voltage (110VAC), full rated load.
MIN
110 watt load:
20
140 watt load:
16
NOM
VAC
ms
Input Current
85 VAC (140 W load)
110 VAC (140 W load)
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
Operating Frequency
Switching frequency of main transformer
PARAMETER
CONDITIONS / DESCRIPTION
2.5
2.0
ARMS
41
APK
22
MIN
NOM
kHz
MAX
Efficiency
Full load @110 VAC. Varies with distribution of loads among outputs
Minimum Loads
Single output models
MAP140-3000P, total output current of V1 + V2 6
Ripple and Noise
Full load, 20 MHz bandwidth.
See Model Selection Chart
Single output models
See Model Selection Chart
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
6
3
UNITS
70% typical
0
2
Amps
MAP140-3000P with convection cooling
80
Watts
MAP140-3000P with 200 LFM forced air cooling
140
Watts
1
%
Output voltage overshoot/undershoot at turn-on / turn-off.
Varies by output, regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to
100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple
output units).
Time required for initial output voltage
stabilization.
See Model Selection Chart
μs
500
MAP140-3000P
1
Single output models
2
Sec
Time required for output voltage to rise from 10% to 90%.
20
ms
Minimum load is required only to meet the regulation limits of V3.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00574_AC
Asia-Pacific
+86 755 298 85888
MAP140 Series
4
PARAMETER
CONDITIONS/DESCRIPTION
MIN
MAP140-3000P, V1
Overvoltage Protection
Provided on single output models and MAP140-1012
V1 of MAP140-3000P.
MAP140-1024G
MAP140-1048
Overload Protection
Remote Sense
Voltage drop compensated for at the load.
Overtemperature Protection
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
MAX
6.1
7.2
17.3
20.2
32.2
37.8
55.2
64.8
UNITS
V
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Power Fail Warning
NOM
250
TTL compatible logic signal. Time before regulation dropout due to
loss of input power at 140 watts, 110 VAC. Standard on MAP1403000P and optional on MAP140-1012.
Optional signal provides system shutdown due to excessive internal
temperature. See options.
2.3
CONDITIONS / DESCRIPTION
MIN
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Input to Chassis
Input to Output (tested by manufacturer only)
2121
4242
mV
ms
NOM
MAX
UNITS
VDC
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated
B
Class
Conducted
EN55022 / CISPR 22 conducted
B
Class
ESD Susceptibility
Per EN61000-4-2, level 4
Radiated Susceptibility
EFT/Burst
Input Transient Protection
EN61000-4-5 Class 3
Insulation Resistance
Input to output
8
kV
Per EN61000-4-3, level 3
10
V/M
Per EN61000-4-4, level 3
±2
kV
1
2
kV
Leakage Current
Per EN60950, 264 VAC
PARAMETER
CONDITIONS / DESCRIPTION
Altitude
Operating
Non-operating
Operating Temperature9
Derate linearly above 50°C by 2.5% per °C
Storage Temperature
Line to Line
Line to Ground
MΩ
10
110 VAC
264 VAC
MIN
At 100% load:
At 50% load:
NOM
0.5
1.5
mA
MAX
UNITS
0
0
10k
40k
50
70
-40
85
°C
±0.05
%/°C
±0.02
ASL Feet
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
Relative Humidity
Non-condensing
95
%RH
Shock
Operating, peak acceleration
20
G
Vibration
Random vibration, 10Hz to 2kHz, 3 axis
6
GRMS
[email protected]
MAP140 Series
5
PARAMETER
CONDITIONS / DESCRIPTION
Dimensions
177.8 x 109.2 x 50.0 mm (7.00 x 4.30 x 1.97 inch)
Weight
0.59 kg (1.3 lbs)
Cover (Option)
Power Fail Signal
Thermal Shutdown
Add ‘C’ suffix to model number (Please check with factory for availability).
For convection cooled applications, derate output power to 75 watts, maximum.
Dimensions: 182.9 x 106.7 x 50.0 mm (7.20 x 4.20 x 1.97 inch)
Add ‘P’ suffix to model number. Provides 2.3mS warning time before main output drops 5%.
Warning time increases at reduced load levels. Option available only on MAP140-1012 and MAP140-1024G.
Power fail is standard on MAP140-3000P.
Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition.
Automatic recovery. Where available, Power Fail signal is initiated prior to shutdown.
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00574_AC
Asia-Pacific
+86 755 298 85888
Similar pages