Bel Power Solutions MAP140 Series provides a full range of options and up to 30 watts more power than comparable products in this industry-standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6 watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems. Rated for use in convection and forced-air cooled (200 LFM) applications, the MAP140 delivers dependable power with a Mean Time Between Failures (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and NEMKO regulatory compliance, the MAP140 displays the CE Mark. RoHS Lead-Solder-Exemption Compliant Universal Input 85-264 VAC Input Transient & ESD Compliance to EN61000-4-2/-3/-4 CE marked to Low Voltage Directive Industry-Standard Footprint: 7.0 x 4.3 x 1.8 inch (177.8 x 109.2 x 45.7 mm) Remote Sense and Overvoltage Protection Power Fail Signal Standard on MAP140-3000P, Optional on MAP1401012 and MAP140-1024G Optional Overtemperature Protection, L-bracket and Cover MAP140 Series 2 MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT FORCED AIR CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAP140-1012* 12V/15V 11.0V to 16.0V 9.2/7.3A 3 12.5A/10A3 0.1% 0.5% 1% 11.97V to 12.03V MAP140-1024G 24V/28V 22.8V to 29.2V 4.6/4A 3 6.3A/5.4A 3 0.1% 0.5% 1% 23.95V to 24.05V MAP140-1048* 48V 45.6V to 54.0V 2.3A 3.1A 0.1% 0.5% 1% 47.9V to 48.1V MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT 4 PEAK OUTPUT CURRENT 4 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 +5V 4.75V to 5.25V 16A/25A PK 20A/25A PK 0.2% 1% 1% +12V Fixed 4A/9A PK 4A/9A PK 0.1% 2% 1% -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 2% 1% MAP140-3000P* INITIAL SETTING ACCURACY 5.09V to 5.11V 11.97V to 12.03V -11.4V to 12.6V 1 With minimum 200 LFM forced air cooling. Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3 MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024G output currents are expressed as 24V/28V operation. 4 Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts. 5 Non-G models use lead solder exemption and are not recommended for new designs. Oooooo Model numbers highlighted in yellow are not recommended for new designs. * Obsolete 2 [email protected] MAP140 Series PARAMETER CONDITIONS / DESCRIPTION Input Voltage - AC Continuous input range Input Frequency MAX UNITS 85 264 VAC AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 Hold-up Time Nominal AC input voltage (110VAC), full rated load. MIN 110 watt load: 20 140 watt load: 16 NOM VAC ms Input Current 85 VAC (140 W load) 110 VAC (140 W load) Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C Operating Frequency Switching frequency of main transformer PARAMETER CONDITIONS / DESCRIPTION 2.5 2.0 ARMS 41 APK 22 MIN NOM kHz MAX Efficiency Full load @110 VAC. Varies with distribution of loads among outputs Minimum Loads Single output models MAP140-3000P, total output current of V1 + V2 6 Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Single output models See Model Selection Chart Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time 6 3 UNITS 70% typical 0 2 Amps MAP140-3000P with convection cooling 80 Watts MAP140-3000P with 200 LFM forced air cooling 140 Watts 1 % Output voltage overshoot/undershoot at turn-on / turn-off. Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). Time required for initial output voltage stabilization. See Model Selection Chart μs 500 MAP140-3000P 1 Single output models 2 Sec Time required for output voltage to rise from 10% to 90%. 20 ms Minimum load is required only to meet the regulation limits of V3. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00574_AC Asia-Pacific +86 755 298 85888 MAP140 Series 4 PARAMETER CONDITIONS/DESCRIPTION MIN MAP140-3000P, V1 Overvoltage Protection Provided on single output models and MAP140-1012 V1 of MAP140-3000P. MAP140-1024G MAP140-1048 Overload Protection Remote Sense Voltage drop compensated for at the load. Overtemperature Protection PARAMETER Agency Approvals Dielectric Withstand Voltage MAX 6.1 7.2 17.3 20.2 32.2 37.8 55.2 64.8 UNITS V Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Power Fail Warning NOM 250 TTL compatible logic signal. Time before regulation dropout due to loss of input power at 140 watts, 110 VAC. Standard on MAP1403000P and optional on MAP140-1012. Optional signal provides system shutdown due to excessive internal temperature. See options. 2.3 CONDITIONS / DESCRIPTION MIN Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) 2121 4242 mV ms NOM MAX UNITS VDC Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated B Class Conducted EN55022 / CISPR 22 conducted B Class ESD Susceptibility Per EN61000-4-2, level 4 Radiated Susceptibility EFT/Burst Input Transient Protection EN61000-4-5 Class 3 Insulation Resistance Input to output 8 kV Per EN61000-4-3, level 3 10 V/M Per EN61000-4-4, level 3 ±2 kV 1 2 kV Leakage Current Per EN60950, 264 VAC PARAMETER CONDITIONS / DESCRIPTION Altitude Operating Non-operating Operating Temperature9 Derate linearly above 50°C by 2.5% per °C Storage Temperature Line to Line Line to Ground MΩ 10 110 VAC 264 VAC MIN At 100% load: At 50% load: NOM 0.5 1.5 mA MAX UNITS 0 0 10k 40k 50 70 -40 85 °C ±0.05 %/°C ±0.02 ASL Feet °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) Relative Humidity Non-condensing 95 %RH Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS [email protected] MAP140 Series 5 PARAMETER CONDITIONS / DESCRIPTION Dimensions 177.8 x 109.2 x 50.0 mm (7.00 x 4.30 x 1.97 inch) Weight 0.59 kg (1.3 lbs) Cover (Option) Power Fail Signal Thermal Shutdown Add ‘C’ suffix to model number (Please check with factory for availability). For convection cooled applications, derate output power to 75 watts, maximum. Dimensions: 182.9 x 106.7 x 50.0 mm (7.20 x 4.20 x 1.97 inch) Add ‘P’ suffix to model number. Provides 2.3mS warning time before main output drops 5%. Warning time increases at reduced load levels. Option available only on MAP140-1012 and MAP140-1024G. Power fail is standard on MAP140-3000P. Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition. Automatic recovery. Where available, Power Fail signal is initiated prior to shutdown. Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00574_AC Asia-Pacific +86 755 298 85888