XP Power JCL3024S12 Dc-dc power supply Datasheet

DC-DC
30 Watts
xppower.com
JCL30 Series
•
2:1 Input Range
•
High Efficiency up to 91%
•
-40 °C to +100 °C Operating Temperature
•
Fixed 270 kHz Switching Frequency
•
Regulated Single & Dual Outputs
•
Continuous Short Circuit Protection
•
Standard Remote On/Off
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
Input Surge
General
• 12 VDC (9-18 VDC)
24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input,
Turn off <63% nominal input
• 12 V models 25 VDC for 100 ms
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Output
Output Voltage
Output Voltage Adj
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
Cross Regulation
Ripple & Noise
Transient Response
•
•
•
•
•
•
•
•
•
See table
±10% via trim pin
No minimum load required
±0.5% max
±0.5% max from 10% to full load
±1.0% max
±5.0%, see note 2
75 mV pk-pk max, see note 3
3% max deviation, recovery to within
1% in 200 µs for a 25% load change
• 0.02%/°C
Temperature
Coefficient
Overvoltage Protection • 3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical,
±12.0 V models ±15.0 V typical,
±15.0 V models ±18.0 V typical
Overcurrent Protection • 120% typical
Short Circuit Protection • Trip & restart (hiccup mode)
Remote On/Off
• ON >2.5 VDC or open circuit
OFF <0.8 VDC or short circuit pin 2 & 3
Thermal Protection
• Shuts down when case measures
+110 °C typical
Efficiency
Isolation Voltage
Isolation Capacitance
Switching Frequency
MTBF
• See table
• 1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
• 1200 pF typical
• 270 kHz typical
• 1 MHrs to MIL-STD-217F
Environmental
Operating Temperature
Case Temperature
Storage Temperature
Cooling
Operating Humidity
Shock
Vibration
•
•
•
•
•
•
-40 °C to +100 °C (see derating curve)
+100 °C max
-40 °C to +125 °C
Convection-cooled
Up to 90%, non-condensing
30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
*See note 4
• EN55022, Level A conducted & radiated
with external components see application note
• EN61000-4-2, Level 2 Perf Criteria B
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, Level 3 Perf Criteria A*
• EN61000-4-5, Level 3 Perf Criteria A*
• EN61000-4-6, 3 V rms Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Input
Voltage
Output
Voltage
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±12.0 VDC
±15.0 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±12.0 VDC
±15.0 VDC
3.3 VDC
5.0 VDC
12.0 VDC
15.0 VDC
±12.0 VDC
±15.0 VDC
9-18 VDC
18-36 VDC
36-75 VDC
Input Current(1)
No Load
Full Load
30 mA
1.87 A
30 mA
2.48 A
30 mA
2.84 A
30 mA
2.84 A
30 mA
2.84 A
30 mA
2.84 A
25 mA
0.92 A
25 mA
1.23 A
25 mA
1.40 A
25 mA
1.40 A
25 mA
1.40 A
25 mA
1.40 A
20 mA
0.46 A
20 mA
0.61 A
20 mA
0.70 A
20 mA
0.70 A
20 mA
0.71 A
20 mA
0.71 A
Output
Current
5.50 A
5.00 A
2.50 A
2.00 A
±1.25 A
±1.00 A
5.50 A
5.00 A
2.50 A
2.00 A
±1.25 A
±1.00 A
5.50 A
5.00 A
2.50 A
2.00 A
±1.25 A
±1.00 A
Max Capacitive
Load
15000 µF
10000 µF
2200 µF
1000 µF
±1000 µF
±680 µF
15000 µF
10000 µF
2200 µF
1000 µF
±1000 µF
±680 µF
15000 µF
10000 µF
2200 µF
1000 µF
±1000 µF
±680 µF
Efficiency
83%
86%
90%
90%
90%
90%
84%
87%
91%
91%
91%
91%
84%
87%
91%
91%
91%
91%
Model
Number
JCL3012S3V3
JCL3012S05
JCL3012S12
JCL3012S15
JCL3012D12
JCL3012D15
JCL3024S3V3
JCL3024S05
JCL3024S12
JCL3024S15
JCL3024D12
JCL3024D15
JCL3048S3V3
JCL3048S05
JCL3048S12
JCL3048S15
JCL3048D12
JCL3048D15
Notes
1. Input currents specified at nominal 12 V, 24 V or 48 V input.
2. Cross regulation is ±5% when one output is at 100% and other is varied
between 25% and 100%.
3. Measured with 20 MHz bandwidth and 1 µF ceramic capacitor.
4. External input capacitor required, Nichicon FW series 1000 µF /
100 V or equivalent.
Mechanical Details
All dimensions are in inches (mm)
Weight: 0.11 lbs (48 g)
1.60
(40.64)
0.70
0.50
(17.78)
(12.70)
0.30
0.10
(7.62)
(2.54)
5
4
PIN CONNECTIONS
0.22min
(5.60)
7
6
0.04 DIA
(1.02)
1.80
(45.72
BOTTOM
2.00
(50.80)
VIEW
1
0.70
(17.78)
2
3
0.20
(5.08)
Pin
Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
3
Remote On/Off
Remote On/Off
4
No Pin
+Vout
5
+Vout
Com
6
-Vout
-Vout
7
Trim
Trim
Notes
0.45
(11.43)
1.
2.
3.
4.
0.60
(15.24)
All dimensions are in inches (mm).
Pin diameter: 0.04 ±0.002 (1.0 ±0.05)
Pin pitch tolerance: ±0.014 (±0.35)
Case tolerance: ±0.02 (±0.5)
Application Notes
Derating Curve
External Output Trim
100
7 (7)
7 (7)
Pins in brackets ( )
are for dual
output versions
Load (%)
80
TRIM UP
TRIM DOWN
60
6 (6)
40
20
0
-40 -20
5 (4)
Input Filter
+Vin
+Vout
L
0
10
20 30 40 50 60
Ambient Temperature (ºC)
70
80
90
100
C1
C2
DC/DC
Converter
-Vin
LOAD
-Vout
Remote On/Off Control
Standard ROF logic is positive.
Output On >2.5 VDC or open circuit
Output Off <0.8 VDC or short circuit pins 2 & 3
C3
Model
12 VDC
24 VDC
48 VDC
C1
330 µF, 100 V
330 µF, 100 V
330 µF, 100 V
L
12 µH
12 µH
12 µH
C2
100 µF, 100 V
100 µF, 100 V
100 µF, 100 V
C3
N/A
N/A
1000 pF/2k V
27-Nov-08
DC-DC
JCL30
Models and Ratings