Emerson Network Power AVE360-48S12P-4 Delivers up to 30a output current Datasheet

AVE360-48S12 DC/DC Converter TRN
AVE360-48S12 DC/DC Converter
Technical Reference Note
Industry Standard Half Brick: 36~75V Input, 12V Single Output
Features
Industry Standard Half Brick: 2.4” X 2.28’’ X 0.5’’
Options
•
•
Choice of positive logic or negative logic
for CNT function
Choice of short pins or long pins
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Delivers up to 30A output current
Basic isolation
Ultra High efficiency
Improved thermal performance:
High power density
Low output noise
2:1 wide input voltage of 36-75V
CNT function
Remote sense
Trim function: +10%/-10%
Input under-voltage lockout
Output over-current protection
Output over-voltage protection
Over-temperature protection
Description
The AVE360-48S12 is a new DC/DC converter for optimum efficiency and power density.
AVE360-48S12 provides up to 30A output current in an industry standard Half Brick, which makes it
an ideal choice for small space and high power applications. AVE360-48S12 uses an industry
standard half brick 61.0mm × 57.9mm × 12.7mm (2.4”x2.28”x0.5”), provides CNT and trim functions.
AVE360-48S12 can provide 12V@30A, single output and output is isolated from input.
TEL: (86) 755-86010808
BOM: 31020718
www.emersonnetworkpower.com.cn
DATE: 2008-04-29
1/19
REV1.2
AVE360-48S12 DC/DC Converter TRN
Module Numbering
AVE 360 - 48 S 12
P - 4
Pin length: -4---4.80 mm ± 0.5mm
-6---3.80 mm ± 0.5mm
-8---2.80 mm + 0.5 mm/-0.3 mm
Default is 5.80 mm ± 0.5mm
CNT logic, P---positive, open frame, by default:
negative, open frame
Output rated voltage: 12---12V
Output number: S ---single output, D---dual output
Input rated voltage
Output rated power
Series name
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
2/19
AVE360-48S12 DC/DC Converter TRN
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage and temperature
conditions. Standard test condition on a single unit is as following:
Ta:
25°C
+Vin:
48V ± 2%
-Vin:
return pin for +Vin
CNT:
connect to -Vin
+Vout:
connect to load
-Vout:
connect to load (return)
+Sense:
connect to +Vout
-Sense:
connect to -Vout
Trim (Vadj): open
Input Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Note
Operating Input Voltage
VI
36
48
75
VDC
Inrush transient
-
-
-
2
A2s
-
Input Reflected-ripple Current
II
-
50
80
mAp-p
5Hz to 20MHz: 12µH source
impedance, TA = 25ºC.
-
CAUTION: This power module is not internally fused. An input line fuse must always be used.
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
3/19
AVE360-48S12 DC/DC Converter TRN
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device.
These are absolute stress ratings only. Functional operation of the device is not implied at these or
any other conditions in excess of those given in the operational sections of the IPS. Exposure to
absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Symbol
Min
Typ
Max
Unit
Note
Continuous
VI
0
-
80
Vdc
-
Transient
VI, trans
0
-
100
Vdc
100ms
Operating Ambient Temperature
Ta
-40
25
85
ºC
See Thermal Consideration
Operating Board Temperature
Tc
-
135
ºC
Near temperature sensor Rt
Storage Temperature
TSTG
-55
25
125
ºC
-
Operating Humidity
-
5
-
95
%
-
Basic Input-Output Isolation
-
1,500
-
-
Vdc
1mA for 5 sec, slew rate of
1,500V/10sec
Output Power
Po,max
-
-
360
W
-
Input Voltage
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
4/19
AVE360-48S12 DC/DC Converter TRN
Output Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Conditions
mVp-p
Output Ripple& Noise
-
-
-
300
External Load Capacitance
-
680
2200
10000
μF
(Ta: 25ºC, Vin: 48V,
30000μF can start-up)
Output Voltage Setpoint
Vo,set
11.8
12
12.2
Vdc
Rating input@ Ionom
-
-
-
0.3
%Vo
-
-
-
0.5
%Vo
-
-
-
0.02
%Vo/ºC
Io
0
10
30
A
-
Io
31.5
-
45
A
-
Line
(Vi,min to Vi,max)
Whole range
(f<20MHz)
Load
Output
Regulation
(Io = Io,min to
Io,max)
Temperature
Regulation
Whole range
(Whole range)
Rated Output Current
Output Current-limit Inception
(Hiccup)
Efficiency
Efficiency
TEL: (86) 755-86010808
-
-
93
93
94
94
-
-
%
Ta: 25ºC, Air velocity:
300LFM, Vin: 48V, Load:
Ionom; forced air
direction: from Vin+ to
Vin-
%
Ta: 25ºC, Air velocity:
300LFM, Vin: 48V, Load:
70% Ionom; forced air
direction: from Vin+ to
Vin-
www.emersonnetworkpower.com.cn
5/19
AVE360-48S12 DC/DC Converter TRN
Output Specifications (Cont)
Parameter
Peak Deviation
Dynamic
Response (all)
Settling Time
Symbol
-
Min
-
Typ
-
Max
600
Unit
mV
-
-
-
400
μsec
Turn-On Time
-
-
-
100
msec
Output Voltage Overshoot
-
-
-
5
%Vo
Switching Frequency
-
-
280
-
KHz
(to Vo,nom)
Note
25% Ionom step from
50%Ionom, 0.1A/μS
Io = Ionom;
Vo from 10% to 90%
Io = Ionom;
TEL: (86) 755-86010808
TA = 25C
-
www.emersonnetworkpower.com.cn
6/19
AVE360-48S12 DC/DC Converter TRN
Feature Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Note
Logic Low
-
-0.7
-
1.2
Vdc
-
Logic High
-
3.5
-
5
Vdc
-
Logic Low
-
-
-
1.0
mA
Logic High
-
-
-
-
μA
Output Voltage Adjustment Range*
-
90
-
110
%Vo
-
Output Over-voltage Protection (Static)
Voclamp
14
-
16.5
V
Hiccup
Turn-on Point
-
31
34
36
V
Turn-off Point
-
30
33
35
V
Isolation Capacitance
-
-
-
-
PF
-
Isolation Resistance
-
10
-
-
MΩ
-
Enable pin
voltage:
Enable pin
current:
Under-voltage
Lockout
-
-
Vin: 48V,
Calculated MTBF
-
-
2,000,000
-
Hours Load: Ionom
Board@25oC
Weight
-
-
72
-
g(oz.)
-
Vibration level: 3.5mm (2 ~ 9Hz), 10m/s2 (9 ~ 200HZ), 15m/s2 (200 ~
500HZ)
Vibration (Sine wave)
Directions and time: 3 axes (X, Y, Z), 30 minutes each
Sweep velocity: 1oct / min
Peak acceleration: 300m/s2
Shock (Half-sine wave)
Duration time: 6ms
Continuous shock 3 times at each of 6 directions (±X, ±Y, ±Z)
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
7/19
AVE360-48S12 DC/DC Converter TRN
Characteristic Curves
96
95
Efficiency (%)
94
93
36V
48V
75V
92
91
90
89
88
87
0
5
10
15
20
25
30
35
Output current (A)
Fig. 1
AVE360-48S12 Typical Efficiency
Fig. 2
AVE360-48S12-4 Typical Output Ripple Voltage
o
Ta: 25°C, Air velocity: 300LFM, Vin: 48V, Load: Ionom;
Ta: 25 C, Air velocity: 300LFM, Vin: 48V, Vonom, Ionom,
forced air direction: from Vin+ to Vin-
10μ tantalum (ESR≤100 mΩ)// 1μceramic capacitor
Fig. 3
Fig. 4
AVE360-48S12-4 Typical Transient Response to
Ta: 25℃, Air velocity: 300LFM, forced air direction:
AVE360-48S12-4 Typical Transient Response to
Ta: 25℃, Air velocity: 300LFM, forced air direction:
from Vin+ to Vin-. Vin: 48V, Vonom, 25% Ionom step
step from 50% Ionom, 0.1A/µs ”, the external capacitor
from Vin+ to Vin-. Vin: 48V, Vonom, 50% Ionom
from 75% Ionom, 0.1A/µs ”, the external capacitor
should be “10µ tantalum (ESR≤100 mΩ) // 1µ ceramic
should be “10µ tantalum (ESR≤100 mΩ) // 1µ ceramic
capacitor
capacitor
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
8/19
AVE360-48S12 DC/DC Converter TRN
Performance Curves – Startup Characteristics
Figure 5
Typical start-up from power on
TEL: (86) 755-86010808
Figure 6
Typical start-up from CNT on
www.emersonnetworkpower.com.cn
9/19
AVE360-48S12 DC/DC Converter TRN
Feature Description
CNT Function
Two CNT logic options are available. The CNT
logic, CNT voltage and the module working
state are as the following table.
L
H
OPEN
N
ON
OFF
OFF
P
OFF
ON
ON
N--- means “Negative Logic”
P--- means “Positive Logic”
L--- means “Low Voltage”, -0.7V≤L≤1.2V
H--- means “High Voltage”, 3.5V≤H≤5V
ON--- means “Module is on”, OFF--- means
“Module is off”
Open--- means “CNT pin is left open “
Note: when CNT is left open, VCNT may reach
6V.
Figure 7 shows a few simple CNT circuits.
CNT
CNT
-Vin
-Vin
Simple control
Transistor control
CNT
CNT
-Vin
-Vin
Isolated control
Figure 7
Relay control
CNT circuits
voltage of AVE360-48S12 in order to
compensate for voltage drops in distribution
and maintain a regulated voltage at the point of
load.
When the converter is supporting loads far
away, or is used with undersized cabling,
significant voltage drop can occur at the load.
The best defense against such drops is to
locate the load close to the converter and to
ensure adequately sized cabling is used. When
this is not possible, the converter can
compensate for a drop of up to 10%Vo, through
use of the sense leads.
When used, the + Sense and - Sense leads
should be connected from the converter to the
point of load as shown in Figure 8, using
twisted pair wire, or parallel pattern to reduce
noise effect. The converter will then regulate its
output voltage at the point where the leads are
connected. Care should be taken not to
reverse the sense leads. If reversed, the
converter will trigger OVP protection and turn
off. When not used, the +Sense lead must be
connected with +Vo, and -Sense with -Vo.
Although the output voltage can be increased
by both the remote sense and trim, the
maximum increase for the output voltage is not
the sum of both.
The maximum increase is the larger of either
the remote sense or the trim.
Note that at elevated output voltages the
maximum power rating of the module remains
the same, and the output current capability will
decrease correspondingly.
Remote Sense
+Vo
AVE360-48S12 converter can remotely sense
both lines of its output which moves the
effective output voltage regulation point from
the output terminals of the unit to the point of
connection of the remote sense pins. This
feature automatically adjusts the real output
TEL: (86) 755-86010808
+Sense
+S
Twisted pair
Load
-Sense
-S
-Vo
Figure 8
Sense connection
www.emersonnetworkpower.com.cn
10/19
AVE360-48S12 DC/DC Converter TRN
Note that the trim-up function is valid only when
the input is above 38V.
Trim
The +Vo output voltage of AVE360-48S12 can
be trimmed using the trim pin provided.
Applying a resistor to the trim pin through a
voltage divider from the output will cause the
+Vo output to increase by up to 10% or
decrease by up to 20%. Trimming up by more
than 10% of the nominal output may activate
the OVP circuit or damage the converter.
Trimming down more than 20% can cause the
converter to regulate improperly. If the trim pin
is not needed, it should be left open.
Trim down
With an external resistor between the TRIM
and -SENSE pins, the output voltage set point
decreases (see Figure 10).
+Vin
ON/OFF +Sense
Load
Trim
-Vin
Trim up
+Vo
R adj_down
-Sense
- Vo
With an external resistor connected between
the TRIM and +SENSE pins, the output voltage
set point increases (see Figure 9).
+Vin
Figure 10
Trim down circuit
The following equation determines the required
external-resistor value to obtain a percentage
output voltage change of %.
+Vo
ON/OFF +Sense
Load
Trim
R adj_ up
- Vin
Sense
-Vo
Figure 9
Trim up circuit
The following equation determines the required
external-resistor value to obtain a percentage
output voltage change of %.
Vtrim tolerance less than ±2%,
Radj tolerance is ±1%
Although the output voltage can be increased
by both the remote sense and the trim, the
maximum increase for the output voltage is not
the sum of both. The maximum increase is the
larger of either the remote sense or the trim.
Note that at elevated output voltages the
maximum power rating of the module remains
the same, and the output current capability will
decrease correspondingly.
Vtrim tolerance less than ±2%,
Radj tolerance is ±1%
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
11/19
AVE360-48S12 DC/DC Converter TRN
+Vo
Minimum Load Requirements
There is no minimum load requirement for the
AVE360-48S12 module.
Parameter Device Symbol Typ Unit
Minimum
Load
12V
IMIN
0
A
Output Over-current Protection
AVE360-48S12 DC/DC converter feature
foldback current limiting as part of their
Over-current Protection (OCP) circuits. When
output current exceeds 105 to 140% of rated
current, such as during a short circuit condition,
the module will work on intermittent mode, also
can tolerate short circuit conditions indefinitely.
When the over-current condition is removed,
the converter will automatically restart.
-Vo
Figure 11
Output Capacitance
Output ripple filter
Extra care should be taken when long leads or
traces are used to provide power to the load.
Long lead lengths increase the chance for
noise to appear on the lines. Under these
conditions C2 can be added across the load,
with a 1μF ceramic capacitor C2 in parallel
generally as shown in Figure 12.
+Vo
C1
C2
Load
-Vo
Figure 12
Output ripple filter for a distant load
Decoupling
High output current transient rate of change
(high di/dt) loads may require high values of
output capacitance to supply the instantaneous
energy requirement to the load. To minimize
the output voltage transient drop during this
transient, low Equivalent Series Resistance
(ESR) capacitors may be required, since a high
ESR will produce a correspondingly higher
voltage drop during the current transient.
When the load is sensitive to ripple and noise,
an output filter can be added to minimize the
effects. A simple output filter to reduce output
ripple and noise can be made by connecting a
capacitor C1 across the output as shown in
Figure 11. C1 ranges from 680μF to 10000μF ,
the recommended value for C1 is 2200μF.
TEL: (86) 755-86010808
Load
C1
The converter does not always create noise on
the power distribution system. High-speed
analog or digital loads with dynamic power
demands can cause noise to cross the power
inductor back onto the input lines. Noise can be
reduced by decoupling the load. In most cases,
connecting a 10μF ceramic capacitor in parallel
with a 0.1μF ceramic capacitor across the load
will decouple it. The capacitors should be
connected as close to the load as possible.
Ground Loops
Ground loops occur when different circuits are
given multiple paths to common or earth
ground, as shown in Figure 13. Multiple ground
points can slightly different potential and cause
www.emersonnetworkpower.com.cn
12/19
AVE360-48S12 DC/DC Converter TRN
current flow through the circuit from one point
to another. This can result in additional noise in
all the circuits. To eliminate the problem,
circuits should be designed with a single
ground connection as shown in Figure 14.
RLine
RLine
+Vo
Design Consideration
Load
Load
RLine
-Vo
mode when the maximum device reference
temperature
is
exceeded. When
the
over-temperature condition is removed, the
converter will automatically restart.
Typical Application
RLine
RLine Ground
Loop
Fuse+
+Vin
RLine
Vin
Figure 13
Ground loops
+
C1+
CNT
RLine
RLine
Figure 15
Load
-Vo
RLine
C3
+
+ C2
+
Load
-Vo
+Vin
-Vin
+Vo
Trim
-Vin
+Vo
+Sense
Load
RLine
-Sense
Typical application
F1: Fuse*: Use external fuse (fast blow type)
for each unit.
For 12V output: 30A (Pout=360W)
RLine
Figure 14
C1: Recommended input capacitor C1
≥ 100μF/100V electrolytic or ceramic type
capacitor.
Single point ground
Output Over-Voltage Protection
The output over-voltage protection consists of
circuitry that monitors the voltage on the output
terminals. If the voltage on the output terminals
exceeds the over voltage protection threshold,
then the module will work on hiccup mode.
When the over-voltage condition is removed,
the converter will automatically restart.
The protection mechanism is such that the unit
can continue in this condition until the fault is
cleared.
Over-Temperature Protection
These modules feature an over-temperature
protection circuit to safeguard against thermal
damage. The module will work in intermittent
TEL: (86) 755-86010808
C2: Recommended -40°C ~ 100°C uses:
2,200μF/25V (electrolytic capacitor)
C3: Recommended 10μF/25V
Fusing
The AVE360-48S12 power module has no
internal fuse. An external fuse must always be
employed! To meet international safety
requirements, a 250 Volt rated fuse should be
used. If one of the input lines is connected to
chassis ground, then the fuse must be placed
in the other input line.
Standard safety agency regulations require
input fusing. Recommended fuse ratings for the
AVE360-48S12 are shown as following list.
For 12V output : 30A (Pout=360W)
www.emersonnetworkpower.com.cn
13/19
AVE360-48S12 DC/DC Converter TRN
Note: the fuse is fast blow type.
Input Reverse Voltage Protection
Under installation and cabling conditions where
reverse polarity across the input may occur,
reverse polarity protection is recommended.
Protection can easily be provided as shown in
Figure 16. In both cases the diode used is
rated for 15A/100V. Placing the diode across
the inputs rather than in-line with the input
offers an advantage in that the diode only
conducts in a reverse polarity condition, which
increases circuit efficiency and thermal
performance.
Figure 16
+ Vin
+ Vin
- Vin
- Vin
are to be grounded or both the input and output
pins are to be kept floating. Single fault
testing in the power supply must be performed
in combination with the DC/DC power module
to demonstrate that the output meets the
requirement for SELV. The input pins of the
module are not operator accessible.
Note: Do not ground either of the input pins of
the module, without grounding one of the
output pins. This may allow a non-SELV
voltage to appear between the output pin and
ground. The circuit cannot withstand transient
over-voltage.
Thermal Consideration
Technologies
Reverse polarity protection circuit
Safety Consideration
For safety-agency approval of the system in
which the power module is used, the power
module must be installed in compliance with
the spacing and separation requirements of the
end-use safety agency standard, i.e., UL60950,
CSA C22.2, and EN60950. AVE360-48S12
input-to-output isolation is a basic insulation.
The DC/DC power module should be installed
in end-use equipment, in compliance with the
requirements of the ultimate application, and is
intended to be supplied by an isolated
secondary circuit. When the supply to the
DC/DC power module meets all the
requirements for SELV (<60Vdc), the output is
considered to remain within SELV limits (level
3). If connected to a 60Vdc power system,
double or reinforced insulation must be
provided in the power supply that isolates the
input from any hazardous voltages, including
the ac mains. One input pin and one output pin
TEL: (86) 755-86010808
AVE360-48S12 modules have ultra high
efficiency at full load. With less heat dissipation
and temperature-resistant components such as
ceramic capacitors, these modules exhibit
good behavior during pro-longed exposure to
high temperatures. Maintaining the operating
board temperature within the specified range
helps keep internal component temperatures
within their specifications which in turn help
keep MTBF from falling below the specified
rating. Proper cooling of the power modules is
also necessary for reliable and consistent
operation.
Basic Thermal Management
Measuring the board temperature of the
module is shown in Figure 17.
www.emersonnetworkpower.com.cn
14/19
AVE360-48S12 DC/DC Converter TRN
Because each power module output voltage
has a different power dissipation curve, a plot
of power dissipation versus output current over
three different line voltages are given in Figure
19.
MEASURE CASE
TEMPERATURE HERE
Vin (+)
CNT
Vo (+)
+SENSE
TRIM
Module Derating
-SENSE
Vin (-)
Vo (-)
Experiment Setup
DIMENSIONS: milimeters (inches)
Figure 17
Temperature measurement location
The module should work under 85°C ambient
for the reliability of operation and the board
temperature must not exceed 112°C while
operating in the final system configuration. The
measurement can be made with a surface
probe after the module has reached thermal
equilibrium. No heatsink is mounted, make the
measurement as close as possible to the
indicated position. It makes the assumption
that the final system configuration exists and
can be used for a test environment. Note that
the board temperature of module must always
be checked in the final system configuration to
verify proper operational due to the variation in
test conditions. Thermal management acts to
transfer the heat dissipated by the module to
the surrounding environment. The amount of
power dissipated by the module as heat (PD) is
got by the equation: PD = PI-PO
Where PI is input power; PO is output power;
PD is dissipated power.
Also, module efficiency () is defined as the
following equation:  = PO / PI
If eliminating the input power term, from two
above equations can yield the equation below:
PD = PO (1-) / 
The module power dissipation then can be
calculated through the equation.
TEL: (86) 755-86010808
From the experiment setup shown in Figure 18,
the derating curves shown in Figure 19 can be
drawn. Note that the Printed Wiring Board
(PWB) and the module must be mounted
vertically. The Passage has a rectangular
cross-section. The clearance between the
facing PWB and the top of the module is kept
13 mm (0.5 in.) constantly.
13(0.5)
PWB
Facing PWB
Converter
Air velocity and ambient
temperature testing point
50.8(2.0)
Air flow
Dimensions: millimeters (inches)
Figure 18
Experiment setup
Forced Convection
Figure 19 shows the change of the module
output current with the change of ambient
temperature. In the test, the airflow was
www.emersonnetworkpower.com.cn
15/19
AVE360-48S12 DC/DC Converter TRN
created with externally adjustable fans. A
heatsink should be fitted in the case the input
voltage is 36V or 75V.
35
Power dissipation (W)
30
25
20
36V
48V
75V
15
Dimensions: milimeters (inches)
Figure 20
Non-standard heatsink
10
5
0
0
5
10
15
20
25
30
35
Output current (A)
Figure 19
Forced convection power derating
Airflow direction from Vin(+) to Vin(-): Vin=36,48,75V;
Heatsink Configuration
Dimensions: milimeters (inches)
Several standard heatsinks available for the
AVE360-48S12 are shown in Figure 20 to 22.
Figure 21
Longitudinal fins heatsink
The heatsinks mounted to the top surface of
the module with screws torqued to 0.56 N-m (5
in.-Ib). A thermally conductive dry pad or
thermal grease is placed between the case and
the heatsink to minimize contact resistance
(typically 0.1°C/W to 0.3°C /W) and
temperature differential.
Nomenclature for heatsink configurations is as
follows:
WDxyyy40
Figure 22
Transverse fins heatsink
Heatsink Mounting
x = fin orientation: longitudinal (L) or transverse
(T)
yyy = heatsink height (in 100ths of inch)
For example, WDT5040 is a heatsink that is
transverse mounted for a 61mm × 57.9mm
(2.4in × 2.28in) module with a heatsink height
of 0.5 in.
TEL: (86) 755-86010808
Dimensions: milimeters (inches)
A crucial part of the thermal design strategy is
the thermal interface between the baseplate of
the module and the heatsink. Inadequate
measures taken will quickly negate any other
attempts to control the baseplate temperature.
For example, using a conventional dry insulator
can result in a case-heatsink thermal
impedance of >0.5oC/W, while use one of the
recommended interface methods (using silicon
grease or thermal pads) can result in a
www.emersonnetworkpower.com.cn
16/19
AVE360-48S12 DC/DC Converter TRN
case-heatsink
0.1oC/W.
thermal
impedance
around
have separate airflow paths. This can keep
other system equipment cooler and increase
component life spans.
Soldering
Figure 23
Heatsink mounting
Installation
Although AVE360-48S12 converters can be
mounted in any orientation, free air-flowing
must be taken. Normally power components
are always put at the end of the airflow path or
TEL: (86) 755-86010808
AVE360-48S12 converter is compatible with
standard wave soldering techniques. When
wave soldering, the converter pins should be
preheated for 20-30 seconds at 110oC, and
wave soldered at 260oC for less than 10
seconds.
When hand soldering, the iron temperature
should be maintained at 425oC and applied to
the converter pins for less than 5 seconds.
Longer exposure can cause internal damage to
the converter. Cleaning can be performed with
cleaning solvent IPA or with water.
www.emersonnetworkpower.com.cn
17/19
AVE360-48S12 DC/DC Converter TRN
Mechanical Chart
Device Code Suffix
-4
-6
-8
NONE
L
4.8mm+/-0.5mm
3.8mm+/-0.5mm
2.8mm+0.5/-0.3mm
5.8mm+/-0.5mm
TOLERANCES: X.Xmm= +/-0.5mm
X.XXmm=+/-0.25mm
Pins Definition
Pin Number
P1
P2
P3
P4
TEL: (86) 755-86010808
Function
+Vin
CNT
-Vin
+Vout
Pin Number
P5
P6
P7
P8
www.emersonnetworkpower.com.cn
Function
+SENSE
TRIM
-SENSE
-Vout
18/19
AVE360-48S12 DC/DC Converter TRN
Ordering Information
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current
(A)
Ripple
&Noise
(mV pp,
Max.)
Efficiency
(%)
Typ.
AVE360-48S12-4
36~75
12
30
300
94
AVE360-48S12P-4
36~75
12
30
300
94
Model Number
有毒有害物质或元素标识表
部件
名称
制成板
有毒有害物质或元素
铅
汞
镉
Pb
Hg
Cd
×
○
○
六价铬
C
多溴联苯
多溴联苯醚
PBB
PBDE
○
○
6+
○
○:表示该有毒有害物质在该部件所有均质材料中的含量在 SJ/T-11363-2006 规定的限量要求以下。
×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T-11363-2006 规定的限量要求
艾默生网络能源有限公司一直致力于设计和制造环保的产品,我们会通过持续的研究来减少和消除产品中的有毒有害
物质。以下部件或应用中含有有毒有害物质是限于目前的技术水平无法实现可靠的替代或者没有成熟的解决方案:
1.器件的高温焊料中含有铅。
2.电子器件的玻璃中含有铅。
3.插针的铜合金中含有铅
适用范围:AVE360-48S12
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
19/19
Similar pages