Embedded Power for Business-Critical Continuity Rev. 01.30.08 ASA 10W Series 1 of 2 ASA Series RoHS 10 Watts Total Power: 10 Watts Input Voltage: 24V or 48V # of Outputs: Single Electrical Specifications Input Input range Efficiency2 18 to 36 VDC; 36 to 75 VDC 83%@12Vo Output Special Features • • • • • Encapsulated 2:1 input range 1.25" X 0.8” DIP package 1500Vdc I/O isolation Single output Voltage tolerance Line regulation Load regulation Noise/ripple ±2.0% ±0.8% ±1.2% 100mV for 2.5Vo, 3.3Vo and 5.0Vo 120mV for 12Vo Short circuit protection Auto-restart Switching frequency 350KHz Temperature coefficient ±0.02 /°C Isolation I/O isolation Insulation resistance Insulation capacitance 1500 VDC min. 10Mohm 1000pF Environmental Specifications Operating ambient temperature range Storage temperature Humidity MTBF RoHS Compliant Safety CE Mark -40°C to +60°C (no derating) -55°C to +105°C 5% to 95% (non-condensing) 1 Mhrs demonstrated MTBF Embedded Power for Business-Critical Continuity Ordering Information Americas Input Maximum Output 1 Voltage Output 2 Voltage Model Number Voltage Power 7.5 W ASA03G24-L 18 - 36 V 2.5 V @ 3 A 10 W ASA03F24-L 18 - 36 V 3.3 V @ 3 A 10 W ASA02A24-L 18 - 36 V 5V@2A 10 W ASA00B24-L 18 - 36 V 12 V @ 0.835 A 7.5 W ASA03G48-L 36 - 75 V 2.5 V @ 3 A 10 W ASA03F48-L 36 - 75 V 3.3 V @ 3 A 10 W ASA02A48-L 36 - 75 V 5V@2A 10 W ASA00B48-L 36 - 75 V 12 V@ 0.835 A Please contact Astec for information on other output voltages, power ranges and configurations. Available in RoHS 6 version only. Rev. 01.30.08 ASA 10W Series 2 of 2 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 Mechanical Drawing Top View 31.75 (1.25) 20.32 (0.80) Label 3.05 (0.12) ASTEC 22.86 (0.90) Dot ˀVin -Vin Pb ASA02A48-L IN=48Vdc Nom. OUT=5Vdc Date Code RoHS ӽ0.50 (0.02) For global contact, visit: www.powerconversion.com NC 15.24 (0.60) Bottom View +Vin +Vin -Vout techsupport.embeddedpower @emerson.com NC +Vout While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Dot 2.54 (0.10) 5.08 (0.20) 10.16 (0.40) Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Notes: 1. All specifications subject to change without notice. Mechanical drawings are for reference only. 2. Warranty: 1 yr 3. Label and logo appearance may vary from what is shown on mechanical drawings. Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.