400W Single Output Switching Power Supply ERPF-400 series Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 ■ Features Universal AC input / Full range (Withstand 300VAC surge input for 5 seconds) Built-in active PFC function High efficiency up to 91% Design against rain splash Protections: Short circuit / Overload / Over voltage/ ■ Applications LED strip lighting LED channel letters LED moving sign Over temperature Cooling by free air convection LED indicator for power on Low cost,high reliability 100% full load burn-in test 3 years warranty ■ Description ERPF-400 series is a 400W single output enclosed type AC/DC power surply with the active PFC design. It adopts an aluminum case and the interior is semi-potted, protecting the internal electronic components from rain splash and dust. With the complete protection functions, ERPF-400 is suitable for the applications such as outdoor LED channel letters, billboard, commercial signs, etc. ■ Model Encoding ERPF - 400 - 24 Output voltage(12V/24V/48V) Output wattage Series name File Name:ERPF-400-SPEC 2017-08-14 400W Single Output Switching Power Supply ERPF-400 series SPECIFICATION ERPF-400-12 MODEL 12V 24V 48V RATED CURRENT 30A 16.7A 8.3A 0 ~ 30A 0 ~ 16.7A 0 ~ 8.3A 360W 400.8W 398.4W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 240mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.2V VOLTAGE TOLERANCE Note.3 ±1.0% LINE REGULATION ±0.5% 21.6 ~ 26.4V ±1.0% ±0.5% 43.2 ~ 52.8V ±1.0% ±0.5% LOAD REGULATION ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load HOLD UP TIME (Typ.) 10ms/230VAC; 10ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF≧0.95/230VAC, PF≧0.98/115VAC 89% CURRENT RANGE INPUT Note.5 EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. 127 ~ 370VDC 90% cold start 45A/115VAC, 90A/230VAC <1mA / 240VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V Protection type :Shut down O/P voltage, re-power on to recover Shut down O/P voltage, recovers automatically after temperature goes down -30 ~ +60℃ (Refer to output load derating curve) 20 ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note.6) EMC EMISSION IEC/EN 60950-1,CCC GB4943.1-2011 approved -30 ~ +85℃, 10 ~ 95% RH ±0.1%/℃ (0 ~ 35℃) 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH Compliance to EN55022 (CISPR22) class A, GB9254 classA, GB17625.1; EN61000-3-2 EMC IMMUNITY Compliance to EN61000-4-5;light industry level,criteria A MTBF DIMENSION 233.422Khrs min. MIL-HDBK-217F (25℃) 220.4*130*48mm (L*W*H) 1.1Kg; 9pcs / 11Kg / 0.63CUFT PACKING NOTE 91% 2.5A/230VAC 3A/115VAC WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS ERPF-400-48 DC VOLTAGE RATED POWER OUTPUT ERPF-400-24 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Please refer to Static Characteristics". 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 450mm*450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com). File Name:ERPF-400-SPEC 2017-08-14 ERPF-400 400W Single Output Switching Power Supply Mechanical Specification Case No.230 200 series Unit:mm 8.6 LED +V ADJ. 65 9 8 9.5 7 130 6 5 ψ8 4 8 3 20.4 2 3 1 Terminal Pin No. assignment : 5 40 Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. Assignment Max mounting torque 4~6 DC OUTPUT +V 8Kgf-cm 7~9 DC OUTPUT -V Block Diagram fosc : 80KHz EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.V.P. FG O.L.P. O.T.P. PWM&PFC CONTROL DETECTION CIRCUIT Derating Curve Static Characteristics 100 100 80 75 65 50 LOAD (%) LOAD (%) 60 40 20 -30 -10 0 10 20 30 35 40 AMBIENT TEMPERATURE (℃) 50 60 (VERTICAL) 50 25 90 100 150 200 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:ERPF-400-SPEC 2017-08-14 400W Single Output Switching Power Supply ERPF-400 series Installation 1.ERPF-400 is designed for outdoor application and should be installed in the place with shelter. 2.ERPF-400 should be installed in an upright position,leaning forward,backward or lay flat are not allowed Faulty installation methods Correct installation method 20cm 20cm 20cm 10m 20cm 3.For heat dissipation, at least 20cm installation distance around the PSU should be kept, shown as below: File Name:ERPF-400-SPEC 2017-08-14