Honeywell CSCA0600A000B15B02 Hall-effect based open-loop current sensor Datasheet

CSCA-A Series
Hall-Effect Based Open-Loop
Current Sensors
DESCRIPTION
The CSCA-A Series of open-loop current sensors are based
concentrated in the gap in this core. The HED is located in this
on the principles of the Hall-effect wherein a Hall-effect device
core gap. Therefore, the HED output is directly proportional to
(HED) produces an output voltage linearly related to the
the amplitude and phase of the primary current.
amplitude and phase of a magnetic field applied to it.
The HED output is trimmed for gain and offset calibration such
Current flowing through a primary conductor generates a
that the CSCA-A Series sensor provides a predefined output
rotating magnetic field around the conductor. This field is
sensitivity versus primary current.
collector by a core of magnetically sensitive material and
FEATURES
POTENTIAL APPLICATIONS
•
Measures ac, dc and impulse currents
•
Variable speed drives
•
Competitive cost/performance ratio
•
Ground fault detectors
•
Low power consumption
•
Current feedback control systems
•
Compact size
•
Robotics
•
High level of electrical isolation between primary and
•
UPS and telecommunication power supplies
secondary circuits
•
Welding power supplies
•
Large primary aperture
•
Automotive - Battery management systems
•
RoHs compliant
•
Watt meters
•
CE, UL approvals (pending)
CSCA-A Series
SPECIFICATIONS (all specifications are at ±15 Vdc supply and 25 °C [77 °F] ambient temperature unless otherwise specificed)
Characteristic
Symbol Parameter
Nominal current
IPN
See product selection guide
Peak measuring range (ac peak)
IPK
See product selection guide
Nominal output voltage at IPN
VSN
4V±1%
Supply voltage
Vcc
±15 Vdc ± 5 %
Supply current
Icc
17 mA typ.
Accuracy at IPN 1
X
< ±2 % of IPN
Linearity 2
EI
< ±1 %
< ±20 mV
VO
Zero current offset
< ±20 mV
VOR
Residual offset after IPN
Thermal drift of offset
VOT
< ±3 mV/°C @ IPN = 50 A
< ±1.5 mV/°C @ IPN = 100 A to 600 A
Thermal drift of gain
VST
< ±4 mV/°C
Response time 3
tR
3 µs to 7 µs
di/dt
di/dt accuracy followed
> 50A/µs
Bandwidth
f
dc to 50 kHz
Isolation voltage
VD
3 kV, 50 Hz, 60 sec
Rated insulation voltage
VI
849 V reinforced
Output resistance
RS
> 10 kOhm
Ambient operating temperature
TA
-10 °C to 80 °C [14 °F to 176 °F]
Ambient storage temperature
TS
-25 °C to 85 °C [-13 °F to 185 °F]
NOTES:
1
For IP > IPN then X is the same percentage value but of IP
2
Independent linearity per the Instrument Society of America
3
At 90% of IP
4
Appropriate specification items defined using the guidance of EN50178
2
www.honeywell.com/sensing
Hall-Effect Based Open Loop Current Sensors
MOUNTING DIMENSIONS (For reference only. mm)
CSCA-A-001
CSCA-A-002
Pins arrangement
Pins arrangement
1. + 15 V
1. + 15 V
2. - 15 V
2. - 15 V
3. Output
3. Output
4. Ground
4. Ground
Honeywell Sensing and Control
3
ORDER GUIDE
Catalog listing
Description
CSCA0050A000B15B01
CSCA0100A000B15B01
CSCA0200A000B15B01
CSCA0300A000B15B01
CSCA0400A000B15B01
CSCA0500A000B15B01
CSCA0600A000B15B01
CSCA0050A000B15B02
CSCA0100A000B15B02
CSCA0200A000B15B02
CSCA0300A000B15B02
CSCA0400A000B15B02
CSCA0500A000B15B02
CSCA0600A000B15B02
Hall-effect based, open-loop current sensor, Molex-type connector, 50 A rms nominal, ±150 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 100 A rms nominal, ±300 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 200 A rms nominal, ±600 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 300 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 400 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 500 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Molex-type connector, 600 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Gallant connector, 50 A rms nominal, ±150 A range
Hall-effect based, open-loop current sensor, Gallant connector, 100 A rms nominal, ±300 A range
Hall-effect based, open-loop current sensor, Gallant connector, 200 A rms nominal, ±600 A range
Hall-effect based, open-loop current sensor, Gallant connector, 300 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Gallant connector, 400 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Gallant connector, 500 A rms nominal, ±900 A range
Hall-effect based, open-loop current sensor, Gallant connector, 600 A rms nominal, ±900 A range
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop devices
or in any other application where failure of the product could result
in personal injury.
Failure to comply with these instructions could result in death
or serious injury.
•
The information presented in this product sheet is for reference
only. Do not use this document as a product installation guide.
• Complete installation, operation, and maintenance information
is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death
or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgement or consult your local sales
office for specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event
shall Honeywell be liable for consequential, special, or indirect
damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we supply
is believed to be accurate and reliable as of this printing. However, we
assume no responsibility for its use.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network of sales
offices, representatives and distributors. For application assistance,
current specifications, pricing or name of the nearest Authorized
Distributor, contact your local sales office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, Minnesota 55422
www.honeywell.com/sensing
005872-1-EN IL50 GLO Printed in USA
February 2007
Copyright © 2007 Honeywell International Inc. All rights reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
CSCA0100A000B15B01 CSCA0200A000B15B01 CSCA0300A000B15B01 CSCA0400A000B15B01
CSCA0500A000B15B01 CSCA0600A000B15B01 CSCA0050A000B15B02 CSCA0100A000B15B02
CSCA0300A000B15B02
Similar pages