Specifications
MODELS
DRF-120-24-1
DRF-240-24-1
DRF-480-24-1
AC Input voltage range VAC
85-264
Input frequency Hz
47-63
Inrush cold (typ) A
20
40
Power factor (typ) (115/230) 0.98/0.95
0.98/0.95
0.98/0.92
Input current (typ) (2) A
1.2/0.6
2.4/1.2
4.7/2.5
Output voltage V
24
Output current A
5
10
20
Peak output current (1) A
7.5
15
30
Peak output power (1) W
180
360
720
Line regulation mV
<96
Load regulation mV
<240
Ripple and noise (2 & 3) mV
<240
Over current protection (4) -
>105% peak output current
Over voltage protection (5) V
30-35.5
Hold up time (230VAC) ms
20
Efficiency (typ) (230VAC)
%
91
94
Average efficiency (230VAC)
%
88.6
92.4
92
Standby input power (230VAC) W
<0.5
<0.5
<0.75
Parallel operation (6) -
Possible
Series operation (6) -
Possible
LED indicators DC OK signal - green (Vout > 80% rated output voltage): Peak power mode - red
DC OK relay (24V model only) -
Relay contact 30V/1A
Operating temperature °C
-25°C to +70°C(60 to 70°C derate linearly to 75% load)
Storage temperature °C
-40°C to +85°C
Operating humidity -
5-95% RH (non condensing)
Cooling -
Convection
Withstand voltage -I/P to FG:1.5kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to FG: 500VAC (100mA) for 1 min
Isolation resistance
MΩ
I/P to FG, IP to O/P and O/P to FG: >100MOhms (500VDC) at 25°C & 70%RH
Vibration -Non-operating,10-55Hz(sweep for 1 min.):19.6 m/s2 constant, X,Y,Z axis 1 hour each
Shock -
<196m/s2
Safety agency approvals (7) -
IEC/EN/UL60950-1, CE, UL508 listed, ATEX, IEC Ex, GL
Emissions -
EN55022 Class B, CISPR22-B
Immunity -
EN61000-4-2,-3,-4,-5,-6,-8,-11
Weight (typ) g
600
900
1300
Size (W x H x D) mm
36.5 x 123.4 x 115
49 x 123.4 x 115
82 x 123.4 x 115
Case material -
Metal
Warrantyyrs
5
See Page 2 for Notes
DRF Series (provisional datasheet)
1
Notes from page 1
1. Operating period at peak output current is 4 sec, max duty cycle<35% &< rated output power
2. At 115/230VAC, Ta = 25°C, nominal output voltage, rated output power
3. Ripple & noise is measured at 20MHz using 300mm twisted pair of load wires terminated with 0.1µF film cap & 47µF electrolytic cap
4. Constant current (CC) limit for >101% of peak output current. CC limit with auto recovery within 4 sec, unit will shutdown at >4sec
5. Output will shutdown, manual reset by mains cycle off/on or CNT on/off
6. Refer to instruction manual
7. Select /HL model for ATEX, IEC Ex and GL (Germanischer Lloyd) approvals (see optional models table)
Model Selector
Output
Voltage
Output Adjust
Range (V)
Max Output
Current (A)
Max Output
Power (W)
Efficiency at
115/230VAC (%)
DRF120-24-1
24
24-28
5
120
89/91
DRF240-24-1
24
24-28
10
240
92.5/94
DRF480-24-1
24
24-28
20
480
92.5/94
Model
Signal Connector Pin Assignment
PIN
Function
1
2
3
4
5
6
7
8
CB
For parallel operation cut the link between pins 1 & 2 for droop mode current share
CB-COM
N/C
No Connection
N/C
CNT+
Remote ON/OFF control, when CNT+ is pulled to TTL low the power supply turns ON, otherwise it turns OFF
CNT-
PV
Programming voltage range 5 - 6V presets the output to 24 - 28V
COMM
Detail
DRF120 example*
Terminal Explanation
Connection
1 +V: +Output terminal
2 –V: –Output terminal
3V.ADJ: Output voltage adjust trimmer
The output voltage rises when a trimmer is turned clockwise
4 L: AC Input terminal. Live line (fuse in line)
5 N: AC Input terminal. Neutral line
*Signal connectors are found on the topside of the unit.
See product outline drawings for locations
6 –V: Protective Earth
Connect to safety ground of apparatus or equipment
7 DC OK:
Green LED lights when output voltage is > 80% of rated output voltage
8 PEAK:
Red LED lights when unit is in peak power mode
Optional Models
Suffix
Description
9 DC OK: Relay contact
/HL
Conformally Coated (ATEX, IEC EX, GL)
10 DC OK: Relay contact
2
DRF Series (provisional datasheet)
DRF120-24-1 Outline Drawing
DRF Series (provisional datasheet)
3
DRF240-24-1 Outline Drawing
4
DRF Series (provisional datasheet)
DRF480-24-1 Outline Drawing
DRF Series (provisional datasheet)
5
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
ZAC des Delaches
CS 41077
9 rue Thuillere
91978 Villebon Courtaboeuf
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
[email protected]
www.fr.tdk-lambda.com
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
[email protected]
www.uk.tdk-lambda.com
Italy Sales Office
TDK-Lambda Ltd.
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
[email protected]
www.tdk-lambda.co.il
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
[email protected]
www.it.tdk-lambda.com
Netherlands
[email protected]
www.tdk-lambda.nl
Russia
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
[email protected]
www.tdk-lambda.ru
TDK-Lambda Germany GmbH
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
[email protected]
www.de.tdk-lambda.com
Local Distribution
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
[email protected]
www.de.tdk-lambda.com
Scandinavia Sales Office
Valdemarsgade 7
4100 Ringsted
Denmark
Tel: +45 24 63 95 65
Fax: +45 69 80 44 99
[email protected]
www.emea.tdk-lambda.com
RSG Electronic Components GmbH
Sprendlinger Landstr. 115
D-63069 Offenbach / Germany
Tel. +49.69.984047-0
Fax +49.69.984047-77
[email protected]
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice.
Switzerland Sales Office
DRF Dec13 v4
6
Bahnhofstrasse 50
8305 Dietlikon
Switzerland
Tel: +41 44 850 53 53
Fax: +41 44 850 53 50
[email protected]
www.de.tdk-lambda.com
DRF Series (provisional datasheet)
www.emea.tdk-lambda.com
Similar pages