DATA SHEET 4GB Registered DDR3 SDRAM DIMM EBJ41HE4BDFD EBJ41HE4BDFM EBJ41HE4BDFP (512M words × 72 bits, 2 Ranks) Specifications Features • Density: 4GB • Organization 512M words × 72 bits, 2 ranks • Mounting 36 pieces of 1G bits DDR3 SDRAM sealed in FBGA • Package: 240-pin socket type dual in line memory module (DIMM) PCB height: 30.5mm (max.) Lead pitch: 1.0mm Lead-free (RoHS compliant) and Halogen-free • Power supply: VDD = 1.5V ± 0.075V • Data rate: 1333Mbps/1066Mbps (max.) • Eight internal banks for concurrent operation (components) • Interface: SSTL_15 • Burst lengths (BL): 8 and 4 with Burst Chop (BC) • /CAS Latency (CL): 6, 7, 8, 9 • /CAS write latency (CWL): 5, 6, 7 • Precharge: auto precharge option for each burst access • Refresh: auto-refresh, self-refresh • Refresh cycles Average refresh period 7.8µs at 0°C ≤ TC ≤ +85°C 3.9µs at +85°C < TC ≤ +95°C • Operating case temperature range TC = 0°C to +95°C • Double-data-rate architecture; two data transfers per clock cycle • The high-speed data transfer is realized by the 8 bits prefetch pipelined architecture • Bi-directional differential data strobe (DQS and /DQS) is transmitted/received with data for capturing data at the receiver • DQS is edge-aligned with data for READs; centeraligned with data for WRITEs • Differential clock inputs (CK and /CK) • DLL aligns DQ and DQS transitions with CK transitions • Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS • Posted /CAS by programmable additive latency for better command and data bus efficiency • On-Die-Termination (ODT) for better signal quality Synchronous ODT Dynamic ODT Asynchronous ODT • Multi Purpose Register (MPR) for temperature read out • ZQ calibration for DQ drive and ODT • Programmable Partial Array Self-Refresh (PASR) • /RESET pin for Power-up sequence and reset function • SRT range: Normal/extended • Programmable Output driver impedance control • 1 piece of registering clock driver and 1 piece of serial EEPROM (256 bytes EEPROM) for Presence Detect (PD) • Class B temperature sensor functionality with EEPROM Note: Warranty void if removed DIMM heat spreader. Document No. E1580E30 (Ver. 3.0) Date Published January 2010 (K) Japan Printed in Japan URL: http://www.elpida.com Elpida Memory, Inc. 2009-2010 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Ordering Information Part number Component 1 JEDEC speed bin* Data rate Mbps(max.) (CL-tRCD-tRP) EBJ41HE4BDFD-DJ-F 1333 240-pin DIMM Gold DDR3-1333H (9-9-9) (lead-free and halogen-free) EBJ41HE4BDFD-AE-F 1066 DDR3-1066F (7-7-7) EBJ41HE4BDFM-DJ-F 1333 DDR3-1333H (9-9-9) EBJ41HE4BDFM-AE-F 1066 DDR3-1066F (7-7-7) EBJ41HE4BDFP-DJ-F 1333 DDR3-1333H (9-9-9) EBJ41HE4BDFP-AE-F 1066 DDR3-1066F (7-7-7) Package Contact pad Mounted devices EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-AE-F EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-AE-F EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-GL-F EDJ1104BDSE-GN-F EDJ1104BDSE-DJ-F EDJ1104BDSE-AE-F Mounted logic devices IDT Montage Inphi Note: 1. Module /CAS latency = component CL + 1. Part Number E B J 41 H E 4 B D F D - DJ - F Environment code F: Lead Free (RoHS compliant) and Halogen Free Elpida Memory Type B: Module DRAM Speed Grade DJ: DDR3-1333H (9-9-9) AE: DDR3-1066F (7-7-7) Product Family J: DDR3 Density / Rank 41: 4GB/2-rank Module Type H: Registered (with heat spreader) Logic Device Information D: IDT M: Montage P: Inphi Mono Density E: 1Gb Module Outline F: 240-pin DIMM Mono Organization 4: x4 Die Rev. (Mono) Power Supply, Interface B: 1.5V, SSTL_15 Data Sheet E1580E30 (Ver. 3.0) 2 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Pin Configurations Front side 1 pin 121 pin 48 pin 49 pin 120 pin 168 pin 169 pin 240 pin Back side Pin No. Pin name Pin No. Pin name Pin No. Pin name Pin No. Pin name 1 VREFDQ 61 A2 121 VSS 181 A1 2 VSS 62 VDD 122 DQ4 182 VDD 3 DQ0 63 CK1 123 DQ5 183 VDD 4 DQ1 64 /CK1 124 VSS 184 CK0 5 VSS 65 VDD 125 DQS9 185 /CK0 6 /DQS0 66 VDD 126 /DQS9 186 VDD 7 DQS0 67 VREFCA 127 VSS 187 /EVENT 8 VSS 68 Par_In 128 DQ6 188 A0 9 DQ2 69 VDD 129 DQ7 189 VDD 10 DQ3 70 A10(AP) 130 VSS 190 BA1 11 VSS 71 BA0 131 DQ12 191 VDD 12 DQ8 72 VDD 132 DQ13 192 /RAS 13 DQ9 73 /WE 133 VSS 193 /CS0 14 VSS 74 /CAS 134 DQS10 194 VDD 15 /DQS1 75 VDD 135 /DQS10 195 ODT0 16 DQS1 76 /CS1 136 VSS 196 A13 17 VSS 77 ODT1 137 DQ14 197 VDD 18 DQ10 78 VDD 138 DQ15 198 NC 19 DQ11 79 NC 139 VSS 199 VSS 20 VSS 80 VSS 140 DQ20 200 DQ36 21 DQ16 81 DQ32 141 DQ21 201 DQ37 22 DQ17 82 DQ33 142 VSS 202 VSS 23 VSS 83 VSS 143 DQS11 203 DQS13 24 /DQS2 84 /DQS4 144 /DQS11 204 /DQS13 25 DQS2 85 DQS4 145 VSS 205 VSS 26 VSS 86 VSS 146 DQ22 206 DQ38 27 DQ18 87 DQ34 147 DQ23 207 DQ39 28 DQ19 88 DQ35 148 VSS 208 VSS 29 VSS 89 VSS 149 DQ28 209 DQ44 30 DQ24 90 DQ40 150 DQ29 210 DQ45 31 DQ25 91 DQ41 151 VSS 211 VSS 32 VSS 92 VSS 152 DQS12 212 DQS14 33 /DQS3 93 /DQS5 153 /DQS12 213 /DQS14 34 DQS3 94 DQS5 154 VSS 214 VSS 35 VSS 95 VSS 155 DQ30 215 DQ46 36 DQ26 96 DQ42 156 DQ31 216 DQ47 Data Sheet E1580E30 (Ver. 3.0) 3 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Pin No. Pin name Pin No. Pin name Pin No. Pin name Pin No. Pin name 37 DQ27 97 DQ43 157 VSS 217 VSS 38 VSS 98 VSS 158 CB4 218 DQ52 39 CB0 99 DQ48 159 CB5 219 DQ53 40 CB1 100 DQ49 160 VSS 220 VSS 41 VSS 101 VSS 161 DQS17 221 DQS15 42 /DQS8 102 /DQS6 162 /DQS17 222 /DQS15 43 DQS8 103 DQS6 163 VSS 223 VSS 44 VSS 104 VSS 164 CB6 224 DQ54 45 CB2 105 DQ50 165 CB7 225 DQ55 46 CB3 106 DQ51 166 VSS 226 VSS 47 VSS 107 VSS 167 NC 227 DQ60 48 VTT 108 DQ56 168 /RESET 228 DQ61 49 VTT 109 DQ57 169 CKE1 229 VSS 50 CKE0 110 VSS 170 VDD 230 DQS16 51 VDD 111 /DQS7 171 A15 231 /DQS16 52 BA2 112 DQS7 172 A14 232 VSS 53 /Err_Out 113 VSS 173 VDD 233 DQ62 54 VDD 114 DQ58 174 A12 234 DQ63 55 A11 115 DQ59 175 A9 235 VSS 56 A7 116 VSS 176 VDD 236 VDDSPD 57 VDD 117 SA0 177 A8 237 SA1 58 A5 118 SCL 178 A6 238 SDA 59 A4 119 SA2 179 VDD 239 VSS 60 VDD 120 VTT 180 A3 240 VTT Data Sheet E1580E30 (Ver. 3.0) 4 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Pin Description Pin name Function A0 to A15 Address input Row address Column address A10 (AP) Auto precharge A0 to A13 A0 to A9, A11 A12 (/BC) Burst chop BA0, BA1, BA2 Bank select address DQ0 to DQ63 Data input/output CB0 to CB7 Check bit (Data input/output) /RAS Row address strobe command /CAS Column address strobe command /WE Write enable /CS0, /CS1 Chip select CKE0, CKE1 Clock enable CK0, CK1 Clock input /CK0, /CK1 Differential clock input DQS0 to DQS17, /DQS0 to /DQS17 Input and output data strobe SCL Clock input for serial PD SDA Data input/output for serial PD SA0, SA1, SA2 Serial address input VDD Power for internal circuit VDDSPD Power for serial EEPROM VREFCA Reference voltage for CA VREFDQ Reference voltage for DQ VSS Ground VTT Termination Voltage /RESET Set DRAM to known state ODT0, ODT1 ODT control Par_In Parity bit for the Address and Control bus /Err_Out Parity error found on the Address and Control bus /Event Temperature event pin NC No connection Data Sheet E1580E30 (Ver. 3.0) 5 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Serial PD Matrix -AE -DJ Byte No. Function described Hex Comments Hex Comments 0 Number of serial PD bytes written/SPD device size/CRC coverage 92h 176/256/0-116 92h 176/256/0-116 1 SPD revision 10h Rev.1.0 10h Rev.1.0 2 Key byte/DRAM device type 0Bh DDR3 SDRAM 0Bh DDR3 SDRAM 3 Key byte/module type 01h RDIMM 01h RDIMM 4 SDRAM density and banks 02h 1G bits, 8 banks 02h 1G bits, 8 banks 5 SDRAM addressing 12h 14 rows, 11 columns 12h 14 rows, 11 columns 6 Module nominal voltage, VDD 00h 1.5V 00h 1.5V 7 Module organization 08h 2 ranks/×4 bits 08h 2 ranks/×4 bits 8 Module memory bus width 0Bh 72 bits/ECC 0Bh 72 bits/ECC 9 Fine timebase (FTB) dividend/divisor 52h 5/2 52h 5/2 10 Medium timebase (MTB) dividend 01h 1 01h 1 11 Medium timebase (MTB) divisor 08h 8 08h 8 12 SDRAM minimum cycle time (tCK (min.)) 0Fh 1.875ns 0Ch 1.5ns 13 Reserved 00h — 00h — 14 SDRAM /CAS latencies supported, LSB 1Ch 6, 7, 8 3Ch 6, 7, 8, 9 15 SDRAM /CAS latencies supported, MSB 00h — 00h — 16 SDRAM minimum /CAS latencies time (tAA (min.)) 69h 13.125ns 69h 13.125ns 17 SDRAM write recovery time (tWR) 78h 15ns 78h 15ns 18 SDRAM minimum /RAS to /CAS delay (tRCD) 69h 13.125ns 69h 13.125ns 19 SDRAM minimum row active to row active delay (tRRD) 3Ch 7.5ns 30h 6.0ns 20 SDRAM minimum row precharge time (tRP) 69h 13.125ns 69h 13.125ns 21 SDRAM upper nibbles for tRAS and tRC 11h — 11h — 22 SDRAM minimum active to precharge time (tRAS), LSB 2Ch 37.5ns 20h 36ns 23 SDRAM minimum active to active /auto-refresh time 95h (tRC), LSB 50.625ns 89h 49.125ns 24 SDRAM minimum refresh recovery time delay (tRFC), LSB 70h 110ns 70h 110ns 25 SDRAM minimum refresh recovery time delay (tRFC), MSB 03h 110ns 03h 110ns 26 SDRAM minimum internal write to read command delay (tWTR) 3Ch 7.5ns 3Ch 7.5ns 27 SDRAM minimum internal read to precharge command delay (tRTP) 3Ch 7.5ns 3Ch 7.5ns 28 Upper nibble for tFAW 01h 37.5ns 00h 30ns 29 Minimum four activate window delay time (tFAW) 2Ch 37.5ns F0h 30ns 30 SDRAM output drivers supported 83h DLL-off, RZQ/6, 7 83h DLL-off, RZQ/6, 7 31 SDRAM refresh options 81h PASR/2X refresh at +85ºC to +95ºC 81h PASR/2X refresh at +85ºC to +95ºC 32 Module thermal sensor 80h Incorporated 80h Incorporated 33 SDRAM device type 00h Standard 00h Standard 34 to 59 Reserved 00h — 00h — Data Sheet E1580E30 (Ver. 3.0) 6 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP -AE -DJ Byte No. Function described Hex Comments Hex Comments 60 Module nominal height 10h 30 < height ≤ 31mm 10h 30 < height ≤ 31mm 61 Module maximum thickness 33h Dual sides w/HS 33h Dual sides w/HS 62 Reference raw card used 24h Row Card E1 24h Row Card E1 63 DIMM Module Attributes 09h 2 rows/1 register 09h 2 rows/1 register 64 Heat Spreader Solution 80h Incorporated 80h Incorporated 65 Register Vendor ID, LSB (IDT) 80h — 80h — (Montage) 86h — 86h — (Inphi) 04h — 04h — B3h — B3h — (Montage) 32h — 32h — (Inphi) B3h — B3h — 61h — 61h — 66 67 Register Vendor ID, MSB (IDT) Register Revision (IDT) (Montage) 05h — 05h — (Inphi) 11h — 11h — 68 Register Type 00h SSTE32882 00h SSTE32882 69 Register Control Word Functions (RC1, 0) 00h Default 00h Default 70 Register Control Word Functions (RC3, 2) 50h Default 50h Default 71 Register Control Word Functions (RC5, 4) 55h Default 55h Default 72 Register Control Word Functions (RC7, 6) 00h Default 00h Default 73 Register Control Word Functions (RC9, 8) 00h Default 00h Default 74 Register Control Word Functions (RC11, 10) 00h Default 00h Default 75 Register Control Word Functions (RC13, 12) 00h Default 00h Default 76 Register Control Word Functions (RC15, 14) 00h Default 00h Default 77 to 116 Reserved 00h — 00h — 117 Module ID: manufacturer’s JEDEC ID code, LSB 02h Elpida Memory 02h Elpida Memory 118 Module ID: manufacturer’s JEDEC ID code, MSB FEh Elpida Memory FEh Elpida Memory 119 Module ID: manufacturing location ×× — ×× — 120 Module ID: manufacturing date yy Year code (BCD) yy Year code (BCD) 121 Module ID: manufacturing date ww Week code (BCD) ww Week code (BCD) ×× — ×× — 35h — 77h — (Montage) 19h — 5Bh — (Inphi) 2Dh — 6Fh — Cyclical redundancy code (CRC) (IDT) 6Ah — C3h — (Montage) E2h — 4Bh — (Inphi) 54h — FDh — 122 to 125 Module ID: module serial number 126 127 Cyclical redundancy code (CRC) (IDT) Data Sheet E1580E30 (Ver. 3.0) 7 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP -AE -DJ Byte No. Function described Hex Comments Hex Comments 128 Module part number 45h E 45h E 129 Module part number 42h B 42h B 130 Module part number 4Ah J 4Ah J 131 Module part number 34h 4 34h 4 132 Module part number 31h 1 31h 1 133 Module part number 48h H 48h H 134 Module part number 45h E 45h E 135 Module part number 34h 4 34h 4 136 Module part number 42h B 42h B 137 Module part number 44h D 44h D 138 Module part number 46h F 46h F 139 Module part number (IDT) 44h D 44h D (Montage) 4Dh M 4Dh M (Inphi) 50h P 50h P 140 Module part number 2Dh — 2Dh — 141 Module part number 41h A 44h D 142 Module part number 45h E 4Ah J 143 Module part number 2Dh — 2Dh — 144 Module part number 46h F 46h F 145 Module part number 20h (Space) 20h (Space) 146 Module revision code 30h Initial 30h Initial 147 Module revision code 20h (Space) 20h (Space) 148 SDRAM manufacturer’s JEDEC ID code, LSB 02h Elpida Memory 02h Elpida Memory 149 SDRAM manufacturer’s JEDEC ID code, MSB FEh Elpida Memory FEh Elpida Memory 00h — 00h — 150 to 175 Manufacturer's specific data 176 to 255 Open for customer use Data Sheet E1580E30 (Ver. 3.0) 8 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Block Diagram /RCS0 /RCS1 RDQS9 /RDQS9 RDQ[7:4] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS0 /RDQS0 RDQ[3:0] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS1 /RDQS1 RDQ[11:8] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS10 /RDQS10 RDQ[15:12] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS2 /RDQS2 RDQ[19:16] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS11 /RDQS11 RDQ[23:20] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS3 /RDQS3 RDQ[27:24] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS12 /RDQS12 RDQ[31:28] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS4 /RDQS4 RDQ[35:32] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS13 /RDQS13 RDQ[39:36] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS5 /RDQS5 RDQ[43:40] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS14 /RDQS14 RDQ[47:44] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS6 /RDQS6 RDQ[51:48] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS15 /RDQS15 RDQ[55:52] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RBA[2:0] RA[15:0] /RRAS /RCAS /RWE RDQS7 /RDQS7 RDQ[59:56] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS16 /RDQS16 RDQ[63:60] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ /RCS[1:0] RCKE[1:0] RODT[1:0] RDQS8 /RDQS8 RCB[3:0] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ RDQS17 /RDQS17 RCB[7:4] VSS DQS /CS /DQS DQ[3:0] DM ZQ DQS /CS /DQS DQ[3:0] DM ZQ D0 D1 D2 D3 D18 D19 D20 D21 D9 D10 D11 D12 D27 D28 D29 D30 22Ω /CS0 /CS1 BA[2:0] A[15:0] /RAS /CAS /WE CKE0 CKE1 ODT0 ODT1 Par_In CK0 120Ω /CK0 /RESET R e g i s t e r /RCS0 : Rank0 /RCS1 : Rank1 RBA[2:0] RA[15:0] /RRAS /RCAS /RWE RCKE0 : Rank0 RCKE1 : Rank1 RODT0 : Rank0 RODT1 : Rank1 /Err_Out PCK[3:0] a n d P L L /PCK[3:0] All SDRAMs D22 D23 D24 D25 D8 D4 D5 D6 D7 D26 D31 D32 D33 D34 D17 D13 D14 D15 D16 D35 15Ω DQ[63:0] CB[7:0] DQS[17:0] /DQS[17:0] RDQ[63:0] RCB[7:0] RDQS[17:0] /RDQS[17:0] 36Ω VTT 36Ω VTT PCK[3:0] 75Ω /PCK[3:0] CK1 VTT VTT D1 D2 D3 D8 D4 D5 D6 D7 VTT D9 D10 D11 D12 D17 D13 D14 D15 D16 VTT VTT VTT D0 VDDSPD VREFCA VTT VDD VREFDQ VSS D27 D28 D29 D30 D35 D31 D32 D33 D34 VTT ZQ VTT 120Ω /CK1 D18 D19 D20 D21 D26 D22 D23 D24 D25 Register 240Ω VSS SPD All SDRAMs All SDRAMs All SDRAMs All SDRAMs Serial PD SCL A0 A1 A2 Address, command and control Note : 1. DQ wiring may be changed within a nibble. SCL A0 A1 SDA U1 A2 /EVENT /EVENT Data Sheet E1580E30 (Ver. 3.0) 9 SDA EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Electrical Specifications • All voltages are referenced to VSS (GND). Absolute Maximum Ratings Parameter Symbol Value Unit Notes Power supply voltage VDD −0.4 to +1.975 V 1, 3, 4 Input voltage VIN −0.4 to +1.975 V 1, 4 Output voltage VOUT −0.4 to +1.975 V 1, 4 Reference voltage VREFCA −0.4 to 0.6 × VDD V 3, 4 Reference voltage for DQ VREFDQ −0.4 to 0.6 × VDDQ V 3, 4 1, 2, 4 Storage temperature Tstg −55 to +100 °C Power dissipation PD 18 W Short circuit output current IOUT 50 mA 1, 4 Notes: 1. Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. Storage temperature is the case surface temperature on the center/top side of the DRAM. 3. VDD and VDDQ must be within 300mV of each other at all times; and VREF must be not greater than 0.6 × VDDQ, When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV. 4. DDR3 SDRAM component specification. Caution Exposing the device to stress above those listed in Absolute Maximum Ratings could cause permanent damage. The device is not meant to be operated under conditions outside the limits described in the operational section of this specification Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Operating Temperature Condition Parameter Symbol Rating Unit Notes Operating case temperature TC 0 to +95 °C 1, 2, 3 Notes: 1. Operating temperature is the case surface temperature on the center/top side of the DRAM. 2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0°C to +85°C under all operating conditions. 3. Some applications require operation of the DRAM in the Extended Temperature Range between +85°C and +95°C case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply: a) Refresh commands must be doubled in frequency, therefore reducing the refresh interval tREFI to 3.9µs. (This double refresh requirement may not apply for some devices.) b) If Self-refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual Self-Refresh mode with Extended Temperature Range capability (MR2 bit [A6, A7] = [0, 1]) or enable the optional Auto Self-Refresh mode (MR2 bit [A6, A7] = [1, 0]). Data Sheet E1580E30 (Ver. 3.0) 10 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Recommended DC Operating Conditions (TC = 0°C to +85°C) Parameter Symbol min. typ. max. Unit Notes Supply voltage VDD, VDDQ 1.425 1.5 1.575 V 1, 2, 3 VSS 0 0 0 V 1 VDDSPD 3.0 3.3 3.6 V VREFCA (DC) 0.49 × VDD — 0.51 × VDD V 1, 4, 5 VREFDQ (DC) 0.49 × VDD — 0.51 × VDD V 1, 4, 5 VTT (DC) 0.49 × VDD — 0.51 × VDD V Input reference voltage for address, command inputs Input reference voltage for DQ, DM inputs Termination voltage Notes: 1. 2. 3. 4. DDR3 SDRAM component specification. Under all conditions VDDQ must be less than or equal to VDD. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together. The AC peak noise on VREF may not allow VREF to deviate from VREF(DC) by more than ±1% VDD (for reference: approx ±15 mV). 5. For reference: approx. VDD/2 ±15 mV. Data Sheet E1580E30 (Ver. 3.0) 11 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP DC Characteristics 1 (TC = 0°C to +85°C, VDD = 1.5V ± 0.075V, VSS = 0V) Parameter Operating current (ACT-PRE) Operating current (ACT-READ-PRE) Symbol Data rate (Mbps) max. Unit IDD0 1333 1066 2140 2030 mA IDD1 1333 1066 2400 2260 mA 1333 1066 1333 1066 1333 1066 1333 1066 1333 1066 1333 1066 1650 1610 1290 1240 1810 1670 2540 2410 1810 1670 1650 1610 IDD2P1 Precharge power-down standby current IDD2P0 mA Fast PD Exit mA Slow PD Exit mA Precharge standby current IDD2N Precharge standby ODT current IDD2NT Precharge quiet standby current IDD2Q Active power-down current (Always fast exit) IDD3P Active standby current IDD3N 1333 1066 1960 1810 mA IDD4R 1333 1066 3250 2820 mA IDD4W 1333 1066 3210 3070 mA Burst refresh current IDD5B 1333 1066 5180 4910 mA Self-refresh current normal temperature range IDD6 1340 mA All bank interleave read current IDD7 5500 4660 mA RESET low current IDD8 180 mA Operating current (Burst read operating) Operating current (Burst write operating) 1333 1066 Data Sheet E1580E30 (Ver. 3.0) 12 Notes mA mA mA EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Timings used for IDD and IDDQ Measurement-Loop Patterns DDR3-1333 DDR3-1066 Parameter 9-9-9 7-7-7 Unit CL 9 7 nCK tCK min. 1.5 1.875 ns nRCD min. 9 7 nCK nRC min. 33 27 nCK nRAS min. 24 20 nCK nRP min. 9 7 nCK nFAW 20 20 nCK nRRD 4 4 nCK nRFC 74 59 nCK DC Characteristics 2 (TC = 0°C to +85°C, VDD, VDDQ = 1.5V ± 0.075V) (DDR3 SDRAM Component Specification) Parameter Symbol Value Input leakage current ILI 2 µA VDD ≥ VIN ≥ VSS Output leakage current ILO 5 µA DDQ ≥ VOUT ≥ VSS Data Sheet E1580E30 (Ver. 3.0) 13 Unit Notes EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Pin Functions CK, /CK (input pin) CK and /CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of /CK. Output (read) data is referenced to the crossings of CK and /CK (both directions of crossing). /CS (input pin) All commands are masked when /CS is registered high. /CS provides for external rank selection on systems with multiple ranks. /CS is considered part of the command code. /RAS, /CAS, and /WE (input pins) /RAS, /CAS and /WE (along with /CS) define the command being entered. A0 to A15 (input pins) Provided the row address for active commands and the column address for read/write commands to select one location out of the memory array in the respective bank. (A10(AP) and A12(/BC) have additional functions, see below) The address inputs also provide the op-code during mode register set commands. [Address Pins Table] Address (A0 to A13) Row address (RA) Column address (CA) AX0 to AX13 AY0 to AY9, A11 Notes A10(AP) (input pin) A10 is sampled during read/write commands to determine whether auto-precharge should be performed to the accessed bank after the read/write operation. (high: auto-precharge; low: no auto-precharge) A10 is sampled during a precharge command to determine whether the precharge applies to one bank (A10 = low) or all banks (A10 = high). If only one bank is to be precharged, the bank is selected by bank addresses (BA). A12 (/BC) (input pin) A12 is sampled during read and write commands to determine if burst chop (on-the-fly) will be performed. (A12 = high: no burst chop, A12 = low: burst chopped.) BA0 to BA2 (input pins) BA0, BA1 and BA2 define to which bank an active, read, write or precharge command is being applied. BA0 and BA1 also determine if a mode register is to be accessed during a MRS cycle. [Bank Select Signal Table] BA0 BA1 BA2 Bank 0 L L L Bank 1 H L L Bank 2 L H L Bank 3 H H L Bank 4 L L H Bank 5 H L H Bank 6 L H H Bank 7 H H H Remark: H: VIH. L: VIL. Data Sheet E1580E30 (Ver. 3.0) 14 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP CKE (input pin) CKE high activates, and CKE low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE low provides precharge power-down and self-refresh operation (all banks idle), or active power-down (row active in any bank). CKE is asynchronous for self-refresh exit. After VREF has become stable during the power-on and initialization sequence, it must be maintained for proper operation of the CKE receiver. For proper self-refresh entry and exit, VREF must be maintained to this input. CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, /CK, ODT and CKE are disabled during power-down. Input buffers, excluding CKE, are disabled during self-refresh. DQ and CB (input and output pins) Bi-directional data bus. DQS and /DQS (input and output pin) Output with read data, input with write data. Edge-aligned with read data, centered in write data. The data strobe DQS is paired with differential signals /DQS to provide differential pair signaling to the system during READs and WRITEs. ODT (input pins) ODT (registered high) enables termination resistance internal to the DDR3 SDRAM. When enabled, ODT is only applied to each DQ, DQS, /DQS, DM. The ODT pin will be ignored if the mode register (MR1) is programmed to disable ODT. VDD (power supply pins) 1.5V is applied. (VDD is for the internal circuit.) VDDSPD (power supply pin) 3.3V is applied (For serial EEPROM). VSS (power supply pin) Ground is connected. VTT (power supply pin) Termination supply. VREFDQ (power supply) Reference voltage for DQ. VREFCA (power supply) Reference voltage for CA. SCL (input pin) Clock input for serial PD. SDA (input and output pins) Data input/output for serial PD. SA (input pin) Serial address input. /RESET (input pin) /RESET is negative active signal (active low) and is referred to GND. Data Sheet E1580E30 (Ver. 3.0) 15 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Par_In (input pin) Parity bit for the Address and Control bus. /Err_Out (output pin) Parity error found on the Address and Control bus. /Event (output pin) Temperature alert output. Detailed Operation Part, Electrical Characteristics and Timing Waveforms Refer to the EDJ1104BDSE, EDJ1108BDSEdatasheet (E1494E). DM pins of component device fixed to VSS level on the module board. DIMM /CAS latency = component CL + 1 for registered type. Data Sheet E1580E30 (Ver. 3.0) 16 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP Physical Outline Unit: mm Front side 8.50 max (DATUM -A-) 4.00 min (Front) 1 120 B A 47.00 1.27 ± 0.10 71.00 133.35 (Back) 30.50 max 240 17.30 121 9.50 Back side C ± ± ± ± ± ECA-TS2-0245-02 Data Sheet E1580E30 (Ver. 3.0) 17 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP CAUTION FOR HANDLING MEMORY MODULES When handling or inserting memory modules, be sure not to touch any components on the modules, such as the memory ICs, chip capacitors and chip resistors. It is necessary to avoid undue mechanical stress on these components to prevent damaging them. In particular, do not push module cover or drop the modules in order to protect from mechanical defects, which would be electrical defects. When re-packing memory modules, be sure the modules are not touching each other. Modules in contact with other modules may cause excessive mechanical stress, which may damage the modules. MDE0202 NOTES FOR CMOS DEVICES 1 PRECAUTION AGAINST ESD FOR MOS DEVICES Exposing the MOS devices to a strong electric field can cause destruction of the gate oxide and ultimately degrade the MOS devices operation. Steps must be taken to stop generation of static electricity as much as possible, and quickly dissipate it, when once it has occurred. Environmental control must be adequate. When it is dry, humidifier should be used. It is recommended to avoid using insulators that easily build static electricity. MOS devices must be stored and transported in an anti-static container, static shielding bag or conductive material. All test and measurement tools including work bench and floor should be grounded. The operator should be grounded using wrist strap. MOS devices must not be touched with bare hands. Similar precautions need to be taken for PW boards with semiconductor MOS devices on it. 2 HANDLING OF UNUSED INPUT PINS FOR CMOS DEVICES No connection for CMOS devices input pins can be a cause of malfunction. If no connection is provided to the input pins, it is possible that an internal input level may be generated due to noise, etc., hence causing malfunction. CMOS devices behave differently than Bipolar or NMOS devices. Input levels of CMOS devices must be fixed high or low by using a pull-up or pull-down circuitry. Each unused pin should be connected to VDD or GND with a resistor, if it is considered to have a possibility of being an output pin. The unused pins must be handled in accordance with the related specifications. 3 STATUS BEFORE INITIALIZATION OF MOS DEVICES Power-on does not necessarily define initial status of MOS devices. Production process of MOS does not define the initial operation status of the device. Immediately after the power source is turned ON, the MOS devices with reset function have not yet been initialized. Hence, power-on does not guarantee output pin levels, I/O settings or contents of registers. MOS devices are not initialized until the reset signal is received. Reset operation must be executed immediately after power-on for MOS devices having reset function. CME0107 Data Sheet E1580E30 (Ver. 3.0) 18 EBJ41HE4BDFD, EBJ41HE4BDFM, EBJ41HE4BDFP The information in this document is subject to change without notice. Before using this document, confirm that this is the latest version. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Elpida Memory, Inc. Elpida Memory, Inc. does not assume any liability for infringement of any intellectual property rights (including but not limited to patents, copyrights, and circuit layout licenses) of Elpida Memory, Inc. or third parties by or arising from the use of the products or information listed in this document. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of Elpida Memory, Inc. or others. Descriptions of circuits, software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software and information in the design of the customer's equipment shall be done under the full responsibility of the customer. Elpida Memory, Inc. assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information. [Product applications] Be aware that this product is for use in typical electronic equipment for general-purpose applications. Elpida Memory, Inc. makes every attempt to ensure that its products are of high quality and reliability. However, users are instructed to contact Elpida Memory's sales office before using the product in aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment, medical equipment for life support, or other such application in which especially high quality and reliability is demanded or where its failure or malfunction may directly threaten human life or cause risk of bodily injury. [Product usage] Design your application so that the product is used within the ranges and conditions guaranteed by Elpida Memory, Inc., including the maximum ratings, operating supply voltage range, heat radiation characteristics, installation conditions and other related characteristics. Elpida Memory, Inc. bears no responsibility for failure or damage when the product is used beyond the guaranteed ranges and conditions. Even within the guaranteed ranges and conditions, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Elpida Memory, Inc. products does not cause bodily injury, fire or other consequential damage due to the operation of the Elpida Memory, Inc. product. [Usage environment] Usage in environments with special characteristics as listed below was not considered in the design. Accordingly, our company assumes no responsibility for loss of a customer or a third party when used in environments with the special characteristics listed below. Example: 1) Usage in liquids, including water, oils, chemicals and organic solvents. 2) Usage in exposure to direct sunlight or the outdoors, or in dusty places. 3) Usage involving exposure to significant amounts of corrosive gas, including sea air, CL 2 , H 2 S, NH 3 , SO 2 , and NO x . 4) Usage in environments with static electricity, or strong electromagnetic waves or radiation. 5) Usage in places where dew forms. 6) Usage in environments with mechanical vibration, impact, or stress. 7) Usage near heating elements, igniters, or flammable items. If you export the products or technology described in this document that are controlled by the Foreign Exchange and Foreign Trade Law of Japan, you must follow the necessary procedures in accordance with the relevant laws and regulations of Japan. Also, if you export products/technology controlled by U.S. export control regulations, or another country's export control laws or regulations, you must follow the necessary procedures in accordance with such laws or regulations. If these products/technology are sold, leased, or transferred to a third party, or a third party is granted license to use these products, that third party must be made aware that they are responsible for compliance with the relevant laws and regulations. M01E0706 Data Sheet E1580E30 (Ver. 3.0) 19