Arch AQF240U-28S Ac-dc switching power supply Datasheet

VER : C_5
update : 2015.03.09
AC-DC Switching Power Supply
AQF240U SERIES
240 Watts
A Type
KEY FEATURES
(except 5S)
 U Bracket Switching Power Supply
 Universal Input: 90-264 VAC
 With P.F.C. Function, PF>0.95
 Free Air Convection
 High Efficiency up to 93%
 RoHS Compliant Design
 Ultra Compact Size: 6.0 x 4.18 x 1.38 Inches
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AQF240
U-5S
180W
Model No.
Max Output Wattage (W)
Voltage
Input
Output
Protection
Isolation
AQF240
U-24S
AQF240
U-28S
AQF240
U-36S
AQF240
U-32S
AQF240
U-48S
90-264 VAC or 120-370 VDC
47-63 Hz
Current (Full load)
<3.0 A max. (115 VAC) / <1.5 A max. (230 VAC)
Inrush Current (<2ms)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 0.5 mA max.
Power Factor
PF>0.98 (115 VAC) / PF>0.95 (230 VAC) at Full Load
Voltage (V.DC.)
5V
Voltage Accuracy
±2%
12V
15V
24V
28V
36V
32V
48V
20
16
10
8.57
6.66
7.5
5
92%
92%
92%
92%
93%
Current (Convection) (A) max
36
Line Regulation
±1%
Load Regulation
Minimum Load
Maximum Capacitive Load
±1%
5%
2%
470-23,000µF depending on model
Ripple & Noise (max.)
150mVp-p
120mVp-p
200mVp-p
Efficiency (at 230VAC)
87%
90%
90%
Hold-up Time
13 ms min.
Over Power Protection
Auto recovery
Over Voltage Protection
Latch Off
Short Circuit Protection
Latch Off
Input-Output (V.AC)
4000VAC or 5656VDC
Input-FG
(V.AC)
2000V
Output-FG
.(V.AC)
500V
-10°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>50,000 h @ 25°C (MIL-HDBK-217F)
Vibration
Dimension (L x W x H)
Physical
AQF240
U-15S
Frequency (Hz)
Operating Temperature
Environment
AQF240
U-12S
240W
Weight
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
5S: 6.0 x 4.18 x 1.46 Inches
(150.0 x 106.0 x 37.0 mm ) Tolerance 0.5 mm
Others: 6.0 x 4.18 x 1.38 Inches
(150.0 x 106.0 x 35.0 mm ) Tolerance 0.5 mm
580 g
Cooling Method
Free convection
Safety
Agency Approvals
EMI
CE, UL60950(except 5S), CB(except 5S)
EMC
(Conducted & Radiated Emission)
EMS (Noise Immunity)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
EN 55022 class B
EN 55024
-1-
VER : C_5
update : 2015.03.09
AC-DC Switching Power Supply
AQF240U SERIES
240 Watts
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage,
please disconnect all Y-Capacitors within Arch power supply.
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : C_5
update : 2015.03.09
AC-DC Switching Power Supply
AQF240U SERIES
MECHANICAL DIMENSION
240 Watts
( Top View )
Standard (5S)
PIN#
Single
1
AC IN (L)
2
AC IN (N)
3
FG
4
+DC OUT
5
+DC OUT
6
-DC OUT
7
-DC OUT
ASSEMBLY INSTRUCTIONS
*U Case
T=2.0mm
Customer is advised to screw into the threads no more than 2.0mm
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : C_5
update : 2015.03.09
AC-DC Switching Power Supply
AQF240U SERIES
240 Watts
Standard (12S、15S、24S、28S、32S、48S)
PIN#
Single
1
AC IN (L)
2
AC IN (N)
3
FG
4
+DC OUT
5
+DC OUT
6
-DC OUT
7
-DC OUT
ASSEMBLY INSTRUCTIONS
*U Case
T=2.0mm
Customer is advised to screw into the threads no more than 2.0mm
A Type (except 5S)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
1
AC IN (L)
2
AC IN (N)
3
FG
4~7
+DC OUT
8~11
-DC OUT
-4-
Similar pages