MPD ME0524S-05 Low cost, 0.5w ultra-miniature sip dc/dc con vert er Datasheet

ME05S Series
Low Cost, 0.5W
Ultra-Miniature SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 0.5W Output Power
Input
Parameter
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
• Ultra-Miniature SIP Case
• 35 Standard Models
Input Voltage Range
• 1,000 VDC Isolation
• >1.1 MHour MTBF
Input Reflected Ripple Current
Input Filter
Min.
2.97
4.50
10.80
21.60
43.20
Typ.
3.3
5.0
12.0
24.0
48.0
20
Max.
3.63
5.50
13.20
26.40
52.80
Units
VDC
mA P - P
Internal Capacitor
• -40°C to +85°C Operation Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±3.0
For VIN Change of 1%
±1.2
See Model Selection Guide
100
±0.02
Momentary (0.5 Sec.)
Max.
Units
%
%
mV P - P
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Conditions
60 Seconds
Min.
1,000
1,000
Typ.
Max.
60
80
Standard
See Note 3
See Note 3
See Note 3
Criteria
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
A
A
A
A
A
A
Units
VDC
M
pF
kHz
Level
Class B
Class B
±8 kV/±6 kV
10V/m
±2 kV
±0.5 kV
10 Vrms
1A/m
Environmental
Parameter
Conditions
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Ambient
Case
Min.
-40
Typ.
-40
Free Air Convection
RH, Non-condensing
Max.
+85
+100
+125
Units
95
%
°C
°C
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL-94V0)
0.05 Oz (1.5g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.121
Typ.
Max.
Units
MHours
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
6.0
7.0
15.0
28.0
54.0
260
Units
Absolute Maximum Ratings
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
ME0503S-03
ME0503S-05
ME0503S-09
ME0503S-12
ME0503S-15
ME0503S-18
ME0503S-24
ME0505S-03
ME0505S-05
ME0505S-09
ME0505S-12
ME0505S-15
ME0505S-18
ME0505S-24
ME0512S-03
ME0512S-05
ME0512S-09
ME0512S-12
ME0512S-15
ME0512S-18
ME0512S-24
ME0524S-03
ME0524S-05
ME0524S-09
ME0524S-12
ME0524S-15
ME0524S-18
ME0524S-24
ME0548S-03
ME0548S-05
ME0548S-09
ME0548S-12
ME0548S-15
ME0548S-18
ME0548S-24
Input
Voltage (VDC)
Nominal
Range
3.3
2.97 - 3.63
3.3
2.97 - 3.63
3.3
2.97 - 3.63
3.3
2.97 - 3.63
3.3
2.97 - 3.63
3.3
2.97 - 3.63
3.3
2.97 - 3.63
5.0
4.5 - 5.5
5.0
4.5 - 5.5
5.0
4.5 - 5.5
5.0
4.5 - 5.5
5.0
4.5 - 5.5
5.0
4.5 - 5.5
5.0
4.5 - 5.5
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
48
43.2 - 52.8
48
43.2 - 52.8
48
43.2 - 52.8
48
43.2 - 52.8
48
43.2 - 52.8
48
43.2 - 52.8
48
43.2 - 52.8
Current (mA)
Full-Load No-Load
205
20
216
25
216
25
201
25
208
25
208
25
208
25
132
20
121
13
128
15
127
18
130
22
127
20
134
25
58
15
54
10
57
15
58
20
61
20
61
15
59
15
31
8
29
8
30
10
30
8
29
10
29
10
29
10
17
6
16
6
17
6
17
6
17
6
17
6
18
10
Output
Voltage
Current
(VDC)
(mA, Max)
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
3.3
5.0
9.0
12.0
15.0
18.0
24.0
Fuse
Capacitive
Load
ciency
Rating
Regulation Effi
Load
(%, Typ)
Slow-Blow
(% Typ)
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
152.0
100.0
56.0
42.0
33.0
28.0
21.0
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. Operation at no-load will not damage these units. However, they may not meet all specifications.
3. These converters will operate without external components. However, to meet the specified EMI
limits, a simple external input filter is required. See the input filter note below for more information.
4. All units are rated for operation at full output power to +85°C. Operation over +85°C without airflow
is not recommended. Output power should be derated linearly from 100% at 85°C to 0% at 100°C.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
±20
±10
±10
±10
±10
±10
±10
(µF, Max)
(mA)
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
500
500
500
500
500
500
500
250
250
250
250
250
250
250
150
150
150
150
150
150
150
75
75
75
75
75
75
75
50
50
50
50
50
50
50
76
70
70
72
73
73
73
76
83
78
79
77
79
75
72
78
73
72
69
68
71
69
73
71
71
73
73
72
60
66
62
64
62
62
61
Mechanical Dimensions
Input Filter
Pin Connections
The filter (C 1 , C 2, C 3 & L 1 ) shown in the figure above
is required to meet EN 55022 level B. Recommended
component values are shown in the table at right.
Capacitor C 1 is a 1210, 100V/ceramic, except for the
48V input which is a 100V/electrolytic. Capacitor C2 is a
1210 100V/ceramic. Capacitor C3 is a 1206 2 kV/ceramic.
To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the
value of capacitor C1 should be changed to 470 µF/100V.
All components should be mounted as close to the unit as
possible.
VIN
C1
L1
C2
C3
(VDC)
(µF)
(µH)
(µF)
(pF)
3.3
5.0
12
24
48
2.2
2.2
2.2
2.2
10.0
18.0
18.0
18.0
18.0
18.0
2.2
2.2
470
470
Pin
1
2
3
4
For 48VDC input models the width of the
unit is 0.29 (7.5) and the pins are set 0.08
(2.0) from the edge of the case. These
dimensions are identified with an “*” on
the mechanical drawing
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
Description
-VIN
+VIN
-VOUT
+VOUT
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the front of the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]