TI1 C0603C103K5RACTU Multi-cal-system evaluation module Datasheet

User's Guide
SBOU087A – August 2010 – Revised April 2011
Multi-Cal-System Evaluation Module
This user’s guide describes the characteristics, operation, and the use of the Multi-Cal-System evaluation
module (EVM). It covers all pertinent areas involved to properly use this EVM board. The document
includes the physical printed circuit board layout, schematic diagrams, and circuit descriptions.
1
2
3
4
5
Contents
Overview ..................................................................................................................... 3
Starter System Setup ....................................................................................................... 9
Expanding the System Size .............................................................................................. 22
Troubleshooting Tips ...................................................................................................... 28
Bill of Materials ............................................................................................................. 29
1
Hardware Included with the Multi-Cal-System EVM Kit ................................................................ 3
2
Multi-Cal-Slave Kit .......................................................................................................... 4
3
Multi-Cal-Interface PCA Card
List of Figures
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
.............................................................................................
Multi-Cal-Test PCA Card ...................................................................................................
Multi-Cal-Interface Cable...................................................................................................
Multi-Cal-Power Cable .....................................................................................................
Multi-Cal-System EVM Hardware Setup .................................................................................
Connect Multi-Cal-Master PCA to USB DAQ Platform ...............................................................
Connect Multi-Cal-Interface Cable to Multi-Cal-Master PCA Card..................................................
Connect Multi-Cal-Interface Cable to Multi-Cal-Interface PCA Card ...............................................
Jumpers on Multi-Cal-Interface PCA Card .............................................................................
Jumpers on Multi-Cal-Test PCA Card ..................................................................................
Connect Multi-Cal-Test PCA Card to Multi-Cal-Interface PCA Card ...............................................
Connect Multi-Cal-Power Cable to Multi-Cal-Master PCA Card ....................................................
Connect Multi-Cal-Power Cable to Power Supplies (Current Loop Output) .......................................
Connect Multi-Cal-Power-Cable to Power Supplies (Voltage Output) ..............................................
Typical Instrument Connection ..........................................................................................
Connect Serial Port to DMM .............................................................................................
Connect IEEE488 to DMM ...............................................................................................
Universal 9-V Supply to USB DAQ Platform ...........................................................................
Connect USB Cable to USB DAQ Platform ............................................................................
Complete System Setup ..................................................................................................
Replace Standoffs .........................................................................................................
Connect the Ribbon Cable to the Master ..............................................................................
Connect Slave Ribbon Cable to Slave..................................................................................
Secure Slave to Master ...................................................................................................
Cable Connections to Slave Board .....................................................................................
Jumper Locations and Positions for Expanding System Size .......................................................
4
5
6
6
9
10
11
11
12
13
14
15
16
17
18
19
20
21
21
22
22
23
24
25
26
27
Microsoft, Windows are registered trademarks of Microsoft Corporation.
All other trademarks are the property of their respective owners.
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
1
www.ti.com
29
Complete Expanded System ............................................................................................. 27
30
Communications Error Message ........................................................................................ 28
31
WIndows Device Manager: Active Human Interface Device Connection .......................................... 28
List of Tables
2
...........................................................................................
1
Recommended Starter System
2
Additional Test Equipment Required ..................................................................................... 7
3
Mode Jumpers on the Multi-Cal-Test PCA ............................................................................. 13
4
Jumper Bank Functions on the Multi-Cal-Test PCA .................................................................. 14
5
Multi-Cal-System EVM Board Parts List
Multi-Cal-System Evaluation Module
...............................................................................
7
29
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Overview
www.ti.com
1
Overview
The Multi-Cal-System Evaluation Module is a set of EVMs that is used to calibrate multiple PGA308 and
PGA309 sensor modules. The PGA308 and PGA309 are two programmable analog sensor signal
conditioners. All components in the Multi-Cal-System can be expanded to calibrate up to 64 sensors
simultaneously. For a more detailed description of the PGA308, please refer to the product data sheet
(SBOS440) available from the Texas Instruments web site at http://www.ti.com. Additional support
documents are listed in the section of this guide entitled Related Documentation from Texas Instruments .
The Multi-Cal-System Evaluation Module consists of two printed circuit boards (PCBs). One board (the
USB DAQ Platform) generates the signals required to communicate with the Multi-Cal-System, which is
the second board (Multi-Cal-Master PCA), as well as support and configuration circuitry. The complete
Multi-Cal-System contains a series of PCBs, and can be expanded to meet your specific system
requirements.
Throughout this document, the abbreviation EVM and the term evaluation module are synonymous with
the Multi-Cal-System Evaluation Module.
1.1
Multi-Cal-System Hardware Options
Figure 1 shows the hardware included with the basic Multi-Cal-System kit. Contact the factory if any
component is missing.
Universal Power Supply
USB DAQ Platform
USB Cable
Multi-Cal-Master PCA
Figure 1. Hardware Included with the Multi-Cal-System EVM Kit
The Multi-Cal-System EVM kit includes the following items:
• Multi-Cal-System PCB: This board multiplexes all the communication signals, sensor module output
signals, and power.
• USB DAQ Platform PCB: This board connects to the USB port on your computer. It generates all the
control signals and communication signals for the Multi-Cal-System.
• USB cable: Connects your computer to the USB DAQ Platform PCB; it is an A-Male to B-Male USB
cable.
• Universal 9V power supply: 9-VDC, 220-V/120-V universal power source. (Adaptors are also provided
for most major countries.)
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
3
Overview
www.ti.com
Figure 2 shows the Multi-Cal-Slave kit. Each Multi-Cal-Slave kit enables you to expand the system by
eight channels. For example, a Multi-Cal-Master kit and one Multi-Cal-Slave kit combine to form a
16-channel system. Seven Multi-Cal-Slave boards and a single Multi-Cal-Master combine to form a
64-channel system.
Slave Ribbon Cable
Multi-Cal-Slave PCA
Figure 2. Multi-Cal-Slave Kit
The Multi-Cal-Slave kit contains these items:
• Multi-Cal-Slave PCB: The slave board adds eight measurement channels to the system. The slave
board is almost identical to the master board. The primary difference between the master and the slave
is that the master connects to the USB DAQ Platform and the slave connects to the master via a
ribbon cable, as shown in Figure 2.
• Slave Ribbon cable: The Slave Ribbon cable connects all the signals and power from the master to
the slave. Note that power is distributed across several wires to minimize loss.
Figure 3 shows the Multi-Cal-Interface PCA card. The Multi-Cal-Interface can be used to connect the
sensor modules to the system. The Multi-Cal-Test boards can also be connected to this board. The
Multi-Cal-Interface board connects to the master or slave via the Multi-Cal-Interface cable on the 37-pin
DSUB connectors.
Terminal block
for connection to
sensor module
DSUB9 connection to
Multi-Cal-Test EVM
Multi-Cal-Interface PCA
DSUB37 connection to
Multi-Cal-Master or
Multi-Cal-Slave
Figure 3. Multi-Cal-Interface PCA Card
4
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Overview
www.ti.com
Figure 4 shows the Multi-Cal-Test PCA card. The Multi-Cal-Test card contains a PGA308 with associated
electronics, jumpers for mode configuration, and a sensor emulator. The equivalent PGA309 test board
does not exist at the time of this writing; it is currently under development. The Multi-Cal-Test board can
be used to verify that the system is functional before connecting your sensor modules. The Multi-Cal-Test
PCA can also be used to demonstrate the accuracy capability of the system. The Multi-Cal-Test PCA is
also a good tool for learning how to use the system.
DSUB9 connects
to interface board
Multi-Cal-Test PCA
Jumper-selected
PGA308 configuration
Jumper-selected
SensorEmulator
Figure 4. Multi-Cal-Test PCA Card
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
5
Overview
www.ti.com
Figure 5 shows the Multi-Cal-Interface cable. The Multi-Cal-Interface cable connects the Multi-Cal-Master
or Multi-Cal-Slave to the Interface board.
DSUB37 female connector
to Multi-Cal-Master PCA
or Multi-Cal-Slave PCA
DSUB37 male connector
to Multi-Cal-Interface PCA
Multi-Cal-Interface Cable
Figure 5. Multi-Cal-Interface Cable
Figure 6 shows the Multi-Cal-Power cable. The Multi-Cal-Power cable connects the power supplies and a
digital multimeter (DMM) to the Multi-Cal-Master PCA card.
Multi-Cal-Power Cable
Banana plugs to power supplies
and digital multimeter
DSUB9 female
connector to
Multi-Cal-Master PCA
Figure 6. Multi-Cal-Power Cable
6
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Overview
www.ti.com
1.2
Recommended Starter System
The Multi-Cal-System starter system is an eight-channel system for calibrating PGA308 and PGA309
sensor modules automatically. The starter system allows you to verify that the Multi-Cal-System meets
your specific application requirements. You can expand the capacity of your system later by adding slave
boards. Each slave board adds another eight channels, for a maximum system capability of 64 channels
(one master and seven slave boards). Table 1 describes the recommended starter system and lists the
quantities of each board required.
Table 1. Recommended Starter System
Quantity
Name
1
Multi-Cal-Master EVM
This basic board gives you eight channels.
Multi-Cal-Interface cable
You may choose to build your own cable
because of cable length requirements. The
construction of the cable is given in the
Multi-Cal System Cable user's guide
(SBOU092).
1
Multi-Cal-Power cable
You may choose to build your own cable
because of cable length requirements. The
construction of the cable is given in the
Multi-Cal System Cable user's guide
(SBOU092).
1
Multi-Cal-Interface EVM
2
2
(1)
Multi-Cal-Test EVM
Comments
(1)
Depending on the mechanical requirements of
your specific system, you may develop your
own interface board.
Two Multi-Cal-Test EVMs allow you to check
two channels. This option is typically enough
for initial evaluation of the system. Eight units
would allow you to fully test all eight channels
of the starter system.
The Multi-Cal-Test EVM board uses the PGA308. The equivalent PGA309 test board does not exist at
the time of this writing; it is currently under development.
There are also several additional pieces of test equipment required; Table 2 summarizes this equipment.
Table 2. Additional Test Equipment Required
Name
Comments
±15V Supply
This is power for the multiplexers on the Multi-Cal-Master board. This
supply can range from ±12 V to ±16 V. Choose a low-noise linear
supply for best performance. This supply also powers slave boards if
you expand the system in the future. Keep in mind the current output
capability.
Current requirement for Master = 150 mA
Current for each Slave = 150 mA
Example: For eight channels and one master = 150 mA
Example: For 64 channels (one master and seven slaves) = 8 x 150
mA = 1.2 A
Loop or DUT Power Supply
This supply can range from 5V to 40V, depending on your sensor
module requirements. This power will be directly connected to the
sensor modules. Choose a low-noise linear supply for best
performance. Keep in mind the current output capability. All sensor
modules are powered simultaneously, so multiply the number of
channels by the expected device current to determine the
requirements.
Example: For eight current loop modules: Assume that maximum
current = 25mA (overcurrent range); 8 x 25 mA = 20 0mA
Example: For 64 current loop modules: 64 x 25 mA = 1.6 A
Precision Digital Multimeter
Must allow for software control through RS-232 or IEEE488.
Suggested instrument is the Agilent 34401A.
This controller is not required if you are using RS-232 control. This
item is a National Instruments IEEE488 controller. It allows you to
connect your computer to the precision multimeter for automatic
control.
GPIB-USB-HS
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
7
Overview
www.ti.com
Table 2. Additional Test Equipment Required (continued)
Name
Comments
RS-232 Cable
1.3
This cable is not required if you are using IEE488 control. This cable
allows you to connect your computer to the precision multimeter for
automatic control. Review the documentation for your precision DMM
for more information on the RS-232 cable. This document gives a
description of the cable required for the Agilent 34401A.
Related Documentation from Texas Instruments
The following document provides information regarding Texas Instruments integrated circuits used in the
assembly of the Multi-Cal-System EVM. This user's guide is available from the TI website under literature
number SBOU087. Any letter appended to the literature number corresponds to the document revision
that is current at the time of the writing of this document. Newer revisions may be available from the TI
web site at http://www.ti.com/, or call the Texas Instruments Literature Response Center at (800)
477-8924 or the Product Information Center at (972) 644-5580. When ordering, identify the document by
both title and literature number.
Document
1.4
Literature Number
PGA308 Product Data Sheet
SBOS440
USB DAQ Platform Users Guide
SBOU056
Multi-Cal-Test EVM User's Guide
SBOU088
Multi-Cal-Master EVM User's
Guide
SBOU089
Multi-Cal-System Cable User's
Guide
SBOU092
Multi-Cal-Slave EVM User's Guide
SBOU094
Multi-Cal-Interface User's Guide
SBOU093
Information About Cautions and Warnings
This document contains caution statements.
CAUTION
This is an example of a caution statement. A caution statement describes a
situation that could potentially damage your software or equipment.
The information in a caution or a warning is provided for your protection. Please read each caution
carefully.
1.5
Applications Questions
If you have questions about this or other Texas Instruments evaluation modules, post a question in the
Amplifiers forum at http://e2e.ti.com. Include in the subject heading the product in which you are
interested.
8
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
2
Starter System Setup
Figure 7 shows the system setup for the Multi-Cal-System EVM. The PC runs software that communicates
with the USB-DAQ-Platform. The USB-DAQ-Platform generates the digital signals used to communicate
with the Multi-Cal-System EVM.
RS-232 or
IEEE488
DMM
Loop or
DUT
Power
±15V
EVM
Power
USB DAQ
Platform
Multi-Cal-Master
Multi-Cal-Interface Board
Pressure
Source
Pressure Sensors in Pressure Manifold
Figure 7. Multi-Cal-System EVM Hardware Setup
2.1
Electrostatic Discharge Warning
Many of the components on the Multi-Cal-System EVM are susceptible to damage by electrostatic
discharge (ESD). Customers are advised to observe proper ESD handling precautions when unpacking
and handling the EVM, including the use of a grounded wrist strap at an approved ESD workstation.
CAUTION
Failure to observe ESD handling procedures may result in damage to EVM
components.
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
9
Starter System Setup
2.2
www.ti.com
Multi-Cal-System Hardware Setup for Recommended Starter Kit
Figure 8 shows how to connect the Multi-Cal-Master board to the USB DAQ Platform board. The best (and
easiest) way to connect the two components is to gently push on both sides of the DSUB connectors.
Make sure that the two connectors are completely pushed together; loose connections may cause
intermittent EVM operation.
Figure 8. Connect Multi-Cal-Master PCA to USB DAQ Platform
10
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 9 illustrates how to connect the Multi-Cal-Interface cable to the Multi-Cal-Master PCA card. It is
important to make sure that the connector is not angled or crooked, and that the screws are fully
tightened. Improperly seated connectors are a common cause of intermittent unit failure.
Figure 9. Connect Multi-Cal-Interface Cable to Multi-Cal-Master PCA Card
Figure 10 shows how the Multi-Cal-Interface cable connects to the Multi-Cal-Interface PCA. Again, it is
important to make sure that the connector is not misaligned or crooked, and that the screws are fully
tightened. Improperly seated connectors are a common cause of intermittent device failure. Make sure
that you connect J1 of the Multi-Cal-Master PCA card to P1 of the Multi-Cal-Interface PCA card. When this
step is complete, repeat the process for the other connector (J0 and P0). It is a good idea to attach labels
to the cable connectors to indicate which connector it is associated with.
Figure 10. Connect Multi-Cal-Interface Cable to Multi-Cal-Interface PCA Card
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
11
Starter System Setup
www.ti.com
Figure 11 shows the jumper setup on Multi-Cal-Interface PCA. The Multi-Cal-Interface PCA has eight
jumpers that allow you to choose between current mode sensor modules (for example, 4 mA to 20 mA)
and voltage mode sensor modules (such as 0-V to 5-V output). Place all jumpers in the V position for
voltage mode; alternatively, place all jumpers in the I position for current mode.
Figure 11. Jumpers on Multi-Cal-Interface PCA Card
12
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 12 illustrates the jumper setup on Multi-Cal-Test PCA card. The Multi-Cal-Test PCA has seven
jumpers that allow you to choose between three different modes of operation (current output, four-wire
voltage output, and three-wire voltage output). The Multi-Cal-Test PCA card also has two banks of
jumpers that select the sensor-emulator output on the test board.
SensorEmulator switch (SW1).
Selects between High bank and
Low bank. Here, Low bank is
selected.
Seven jumpers used to select
the PGA308 mode. Here, 4-wire
Voltage Output is selected.
Jumper banks for
sensor emulator. Select
one of the five positions
for each bank. Here.
Low = 6mV, High = 3mV.
Figure 12. Jumpers on Multi-Cal-Test PCA Card
Table 3 and Table 4 explain how to set the jumpers on the Multi-Cal-Test PCA and the respective jumper
functions. The test board allows all for the operation of the three modes of the PGA308 device. The test
board also has a jumper-selected sensor-emulator. The sensor-emulator creates an input signal for the
PGA308 so that you can perform an example calibration.
Table 3. Mode Jumpers on the Multi-Cal-Test PCA
Mode
Jumper Positions
Current Output
JMP1
JMP2
JMP3
JMP4
JMP5
JMP6
JMP7
= Position without label
= Position without label
= XTR
= XTR
= XTR
= XTR
= XTR
4-Wire Voltage Output
JMP1
JMP2
JMP3
JMP4
JMP5
JMP6
JMP7
= Position
= Position
= Position
= Position
= Position
= Position
= Position
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
without label
without label
without label
without label
without label
without label
without label
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
13
Starter System Setup
www.ti.com
Table 3. Mode Jumpers on the Multi-Cal-Test PCA (continued)
Mode
Jumper Positions
3-Wire Voltage Output
JMP1
JMP2
JMP3
JMP4
JMP5
JMP6
JMP7
= Vto1
= Vto1
= Position
= Position
= Position
= Position
= Position
without label
without label
without label
without label
without label
Table 4. Jumper Bank Functions on the Multi-Cal-Test PCA
Jumper Banks
Function
HIGH1 = 0 mV
HIGH2 = 3 mV
HIGH3 = 12 mV
HIGH4 = 51 mV
HIGH5 = 98 mV
Place the jumper shorting unit on one of these five
positions. This jumper bank determines the
sensor-emulator output when the switch (SW1) is in the
HIGH position. The output of the sensor emulator is the
input to the PGA308.
For example, when the shorting unit is in the HIGH2
position, the PGA308 input signal is 3 mV.
LOW1 = 0 mV
LOW2 = 1 mV
LOW3 = 6 mV
LOW4 = 30 mV
LOW5 = 81 mV
Place the jumper shorting unit on one of these five
positions. This jumper bank determines the
sensor-emulator output when the switch (SW1) is in the
LOW position. The output of the sensor emulator is the
input to the PGA308.
For example, when the shorting unit is in the LOW3
position, the PGA308 input signal is 6 mV.
Figure 13 shows how to connect the Multi-Cal-Test PCA to the Multi-Cal-Interface PCA. The
Multi-Cal-Test PCA demonstrates the capability of the Multi-Cal-System. You can test the accuracy and
repeatability of programmed modules using the Multi-Cal-Test PCA. The Multi-Cal-Test PCA is also
helpful in learning how to use the system. Another purpose for the Multi-Cal-Test PCA is to verify that your
system is fully functional before testing your product.
Figure 13. Connect Multi-Cal-Test PCA Card to Multi-Cal-Interface PCA Card
14
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 14 shows how to connect the Multi-Cal-Power cable to the Multi-Cal-Master PCA card. Make sure
that the cable is properly seated and fully screwed in.
Power cable
Figure 14. Connect Multi-Cal-Power Cable to Multi-Cal-Master PCA Card
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
15
Starter System Setup
www.ti.com
Figure 15 shows how to connect the Multi-Cal-Power cable to power supplies and to the DMM. This
connection is for current loop output sensor modules. Refer to Table 3 for an illustration of how to set the
jumpers on the Multi-Cal-Test PCA for current loop configuration.
NOTE: It is very important that the device power supply is floating. In other words, the negative
terminal on the device power supply is not connected to GND on the ±15-V supply. Also, this
supply should not be referenced to earth ground.
Sense Input
HI
HP34401
DMM
HI
ImN
LO
LO
I
VmP
ImP
Linear
Power Supply
+15V
GND
Floating Linear
Power Supply
-15V
POS
VmN
Voltmeter
plugs are
not connected
NEG
24V
15vP
GND
15vN
J9
Multi-Cal-Master-PCA
Figure 15. Connect Multi-Cal-Power Cable to Power Supplies (Current Loop Output)
16
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 16 shows how to connect the Multi-Cal-Power cable to power supplies and to the DMM. This
connection is for voltage output modules (that is. three-wire and four-wire connections). See Table 3 for
information on how to set the jumpers on the Multi-Cal-Test PCA for current loop configuration.
Sense Input
HP34401
DMM
VmP
HI
HI
LO
LO
VmN
I
ImP
Common ground between 15V and 5V supply
Linear
Power Supply
+15V
GND
Linear
Power Supply
-15V
POS
ImN
Ammeter
plugs are
not connected
NEG
5V
15vP
GND
15vN
SupP
SupN
J9
Multi-Cal-Master-PCA
Figure 16. Connect Multi-Cal-Power-Cable to Power Supplies (Voltage Output)
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
17
Starter System Setup
www.ti.com
Figure 17 shows a photograph of typical power supply and DMM connections. It is recommended to tie
back the two banana jacks that are not connected.
Insulate and
tie back unused
connectors
Use cable to
connect GND of ±12V
to the 5V DUT supply,
if needed
Figure 17. Typical Instrument Connection
18
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 18 shows connection to the serial port of the DMM for communication. This connection is used in
order to have remote control of the instrument. The other end of the cable is connected to the serial port
on your computer. In order to use this capability, you must set the DMM to RS-232 mode. An optional way
to communicate with the DMM is via the IEEE488 card.
RS-232 connection on
34401A
Figure 18. Connect Serial Port to DMM
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
19
Starter System Setup
www.ti.com
Figure 19 shows how to connect the IEEE488 to the DMM. The software for the Multi-Cal-System requires
the National Instruments GPIB-USB-HS. This option is also used for remote control of the instrument. In
order to use this capability, you must set the DMM to IEEE488 mode, and set the address according to
the control script (default = 3). An optional way to communicate with the DMM is through the RS-232 port
on your computer.
IEEE488 card
National Instruments
GPIB-USB-HS
Figure 19. Connect IEEE488 to DMM
20
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Starter System Setup
www.ti.com
Figure 20 shows the connection of the 9-V power supply to the USB DAQ Platform. When you connect
power, three LEDs on the USB DAQ Platform illuminate. If the LEDs do not illuminate, check the power
connections.
Connect universal
9V supply
Three power LEDs
will illuminate
Figure 20. Universal 9-V Supply to USB DAQ Platform
Figure 21 shows the connection of the USB cable to the USB DAQ Platform. When you make this
connection, it is recommended that you first turn your computer sound on. When the cable is plugged in,
you should hear the distinctive Microsoft® Windows® sound that indicates a bew USB device was
recognized. The USB DAQ Platform uses the HID drivers included in the Windows operating system. In
some cases, Windows may display messages the first time the EVM is plugged in (as shown here).
Connect USB port
to the PC
The computer may respond
with these messages
Figure 21. Connect USB Cable to USB DAQ Platform
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
21
Expanding the System Size
www.ti.com
Figure 22 shows the complete Multi-Cal-System setup. At this point, the system is fully connected and you
are ready to run the software.
DMM and
power supply
USB DAQ: Generates
signals and controls
Master and
Slave Mux
Interface boards:
Sensors connect here
Figure 22. Complete System Setup
3
Expanding the System Size
The Multi-Cal-System can be expanded by adding Multi-Cal-Slave boards. Each Multi-Cal-Slave board
adds eight additional channels. The maximum system size is 64 channels (one master and seven slaves).
The first step in expanding the system size is to remove the 0.25-inch standoffs and replace them with
1.25-inch standoffs; this step is shown in Figure 23.
Replace with
1.25-inch standoff
Remove
0.25-inch standoff
Figure 23. Replace Standoffs
22
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Expanding the System Size
www.ti.com
The next step in expanding the physical system size is to connect the slave ribbon cable to the master;
this step is illustrated in Figure 24. Make sure to match the key on the ribbon cable with the notch in the
connector.
Notch in
connector
Ribbon cable
keyed to mate
with connector
Note that the ribbon
cable points away
from the notch
Figure 24. Connect the Ribbon Cable to the Master
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
23
Expanding the System Size
www.ti.com
Now connect the slave ribbon cable to the slave. Make sure to match the key on the ribbon cable with the
notch in the connector, as Figure 25 shows. Note that the cable loop is outside of the master and slave
boards.
Multi-Cal-Slave PCA
Notch in connector
on bottom of Slave PCA
Multi-Cal-Master PCA
Cable is keyed to
mate with connector
on bottom of Slave PCA
Figure 25. Connect Slave Ribbon Cable to Slave
24
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Expanding the System Size
www.ti.com
Secure the Multi-Cal-Slave on top of the Multi-Cal- Master, as Figure 26 illustrates. Use the 0.25-inch
standoffs to fasten the slave on top.
Fasten Slave on top
of Master using
0.25-inch standoffs
Figure 26. Secure Slave to Master
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
25
Expanding the System Size
www.ti.com
Figure 27 shows the connection of the cables to the slave board. Make sure the cable is properly seated
and fully screwed down. Each slave board will have two interface cables. Each interface cable has four
channels.
Slave Mux
Ribbon cable:
Connects Master
to Slave
Master Mux
Figure 27. Cable Connections to Slave Board
26
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Expanding the System Size
www.ti.com
Figure 28 shows the jumpers on the Multi-Cal-Slave board that identify the board location. The jumpers on
each slave board must be in a unique position. For the first slave board connected, set the jumpers in the
Slave1a and Slave1b position. As you add additional boards, increment the jumper position. For example,
on the second board connected, use the Slave2a and Slave2b position.
Place jumpers on Slave
in the Slave1a and Slave1b
positions
Figure 28. Jumper Locations and Positions for Expanding System Size
The final step to expanding the system is to connect the interface-cables from the slave to an interface
board. Figure 29 shows the complete system connection for a 16-channel system (that is, one master and
one slave).
DMM and
power supply
USB DAQ: Generates
signals and controls
Master and
Slave Mux
Interface boards:
Sensors connect here
Figure 29. Complete Expanded System
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
27
Troubleshooting Tips
4
www.ti.com
Troubleshooting Tips
The most common issues that can occur with the Multi-Cal-System are communication problems.
Figure 30 shows the message that occurs if you have a communications problem. If you get this message,
use the Windows Device Manager to check the status of the USB-DIG-Platform.
Figure 30. Communications Error Message
Figure 31 shows the Windows Device Manager and the active connection for a USB-driven human
interface device. When you plug and unplug the USB cable, you can see the device appear and disappear
from the list. Select your device and review the details. It should show up as a Human Interface Device
with PID = 2F90, 2F91, 2F92, or 2F93. If it appears as a good USB device, but is not a human interface
device, then the firmware was not programmed properly.
You can also see in the Windows Device Manager the USB Human Interface Device
that corresponds to the USB-DIG Platform. Note the address is: PID = 2F90.
Figure 31. WIndows Device Manager: Active Human Interface Device Connection
28
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Bill of Materials
www.ti.com
5
Bill of Materials
Table 5 shows the parts list for the Multi-Cal-System EVM board.
Table 5. Multi-Cal-System EVM Board Parts List
No.
Qty
Ref Des
Description
Vendor
Part Number
1
9
C006, C106,
C206, C306,
C406, C506,
C606, C706, C71
Capacitor, 10000pF
50V CERAMIC X7R
0603
KEMET
C0603C103K5RACTU
2
53
C6, C5, C60,
C61, C62, C840,
C842, C907,
C908, C909,
C910, C901,
C902, C903,
C904, C905,
C906, C911,
C912, C913,
C914, C915,
C916, C921,
C928, C929,
C938, C970,
C971, C972,
C973, C001,
C002, C101,
C102, C201,
C202, C301,
C302, C401,
C402, C501,
C502, C601,
C602, C701,
C702, C811,
C812, C813,
C814, C820, C70
Capacitor, .10μF 25V
Ceramic,Y5V 0603
KEMET
C0603C104M3VACTU
3
2
C56, C57
Capacitor, Ceramic,
1μF 25V X5R 0603
Murata Electronics North
America
GRM188R61E105KA12D
4
6
C54, C55, C50,
C51, C65, C72
Capacitor, Tantalum
4.7μF 35V 20% SMD
Nichicon
F931V475MCC
5
4
C1, C2, C3, C4
Capacitor, Ceramic,
.01μF 10% 1000V X7R
1206
Vishay/Vitramon
VJ1206Y103KXGAT5Z
6
1
R938
Resistor, 49.9 kΩ
1/10W 1% 0603 SMD
Panasonic - ECG
ERJ-3EKF4992V
7
1
R8
Resistor, 1 MΩ 1%
1206 TF High Voltage
Stackpole Electronics Inc
HVCB 1206 T2 1M 1% I
8
8
R0, R1, R2, R3,
R4, R5, R6, R7
Resistor, 499 Ω 1/10W
1% 603 SMD
Panasonic - ECG
ERJ-3EKF4990V
9
23
R006, R106,
R206, R306,
R406, R506,
R606, R706,
R007, R107,
R207, R307,
R407, R507,
R607,
R707,R939,
R917, R916,
R963, R964,
R965, R966
Resistor, 100 Ω 1/10W
5% 0603 SMD
Stackpole Electronics Inc
RMCF 1/16 100 5% R
10
8
R004, R104,
R204, R304,
R404, R504,
R604, R704,
Resistor, 200 Ω 1/4W
5% 1206 SMD
Stackpole Electronics Inc
RMCF 1/8 200 5% R
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
29
Bill of Materials
www.ti.com
Table 5. Multi-Cal-System EVM Board Parts List (continued)
30
No.
Qty
Ref Des
Description
Vendor
Part Number
11
32
R001, R002,
R003, R005,
R101, R102,
R103, R105,
R201, R202,
R203, R205,
R301, R302,
R303, R305,
R401, R402,
R403, R405,
R501, R502,
R503, R505,
R601, R602,
R603, R605,
R701, R702
,R703, R705
Resistor, 402 Ω 1/10W
1% 0603 SMD
Panasonic - ECG
ERJ-3EKF4020V
12
1
R64
Resistor, 10 kΩ 1/10W
1% 0603 SMD
Stackpole Electronics Inc
RMCF 1/16 10K 1% R
13
1
R63
Resistor, 69.8 kΩ
1/10W 1% 0603 SMD
Yageo
RC0603FR-0769K8L
14
7
RN1, RN2, RN3,
RN902, RN906,
RN907, RN908
Resistor, ARRAY 100
kΩ 10TRM BSS SMD
CTS Resistor Products
746X101104JP
15
1
R970
Resistor, 0.0 Ω 1/4W
5% 1206 SMD
Vishay/Dale
CRCW12060000Z0EA
16
3
U901, U902,
U905
IC SW Mux analog
1/8CH 16-TSSOP
Analog Devices Inc
ADG1408YRUZ
17
5
U903, U904,
U906, U907,
U908
IC MultiplexeR 8X1
16SOIC
Maxim
MAX354CWE
18
3
U919, U920,
U909
IC Chan Protector
Octal 18-SOIC
Analog Devices Inc
ADG467BRZ
19
32
U001, U002,
U003, U004,
U101, U102,
U103, U104,
U201, U202,
U203, U204,
U301, U302,
U303, U304,
U401, U402,
U403, U404,
U501, U502,
U503, U504,
U601, U602,
U603, U604,
U701, U702,
U703, U704,
Relay Opto DC 60V
600MA 6-SMD
Panasonic Electric Works
AQV102A
20
6
U963, U964,
U965, U916,
U917, U939
Diode Schottky 30 V
200 mA SOT23-3
NXP Semiconductors
BAT754S,215
21
2
U800, U4
IC I/O Expander I2C 8B
16SOIC
Texas Instruments
PCA9534DWR
22
2
U820, U821
IC I/O Expander I2C 8B
16SOIC
Texas Instruments
PCA9534ADWR
23
1
U938
IC Buff/Dvr Noninvert
SOT235
Texas Instruments
SN74LVC1G07DBVR
24
1
U70
IC LDO Reg 10 V 150
mA SOT23-5
Texas Instruments
LP2985A-10DBVR
25
1
U921
IC 3-TO-8
Decoder/Demux
16-SSOP
Texas Instruments
SN74HC138DBR
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Bill of Materials
www.ti.com
Table 5. Multi-Cal-System EVM Board Parts List (continued)
No.
Qty
Ref Des
Description
Vendor
Part Number
26
1
U60
IC .5 A Neg Adj Lin
LDO Reg 8SOIC
Texas Instruments
UCC384DP-ADJ
27
1
U6
IC LDO Reg 150 mA 5
V D2PAK-3 TO-263
Texas Instruments
TL750L05CKTTR
28
1
U5
IC 8 V 150 mA LDO
Reg 8-SOIC
Texas Instruments
TL750L08CD
29
8
U005, U105,
U205, U305,
U405, U505,
U605, U705
IC SGL 2 in Pos-AND
Gate SOT23-5
Texas Instruments
SN74AHC1G08DBVR
30
8
U006, U106,
U206, U306,
U406, U506,
U606, U706
IC Single Inverter Gate
SOT23-5
Texas Instruments
SN74AHC1G04DBVR
31
2
U811, U812
IC Quad 2-In NOR
Gate 14-SOIC
Texas Instruments
SN74HC02D
32
2
U813, U814
IC QUAD 2-Input AND
GatE 14-SOIC
Texas Instruments
SN74HC08D
33
1
U35
IC OCT D-Type F-F
W/Clr 20-SSOP
Texas Instruments
SN74HC273DBR
34
8
D0, D1, D2, D3,
D4, D5, D6, D7
LED RED T1-3/4 Rt
Ang PCB
CML Innovative Technologies
5307H1
35
2
D10, D11
Diode TVS 16 V 400 W
Uni 5% SMA
Littelfuse Inc
SMAJ16A
36
2
D20, D21
TVS 400 W 11 V
Unidirect SMA
Littelfuse Inc
SMAJ11A-TP
37
1
D17
Diode TVS 9.0V 400 W
Uni 5% SMA
Littelfuse Inc
SMAJ9.0A
38
1
D16
Diode TVS 6.0V 400 W
Uni 5% SMA
Littelfuse Inc
SMAJ6.0A
39
5
D12, D8, D9,
D14, D15
Diode Schottky 100 V 5
A PowerDI5
Diodes Inc
PDS5100H-13
40
3
Fuse1, Fuse2,
Fuse3
PTC Reset 30 V .200 A
SMD 1210
Littelfuse Inc
1210L020WR
41
2
L2, L3
Inductor Unshield 100
μH .52A SMD
JW Miller A Bourns Company
PM54-101K-RC
42
2
F1, F2
Ferrite Chip 120 Ω
3000 mA 1206
Murata Electronics North
America
BLM31PG121SN1
43
2
J0, J1
Conn DB37 MALE
.318" R/A NICKEL
Norcomp Inc.
182-037-113R531
44
1
J9
Conn D-SUB Plug R/A
9 Pos Gold/FL
AMP/Tyco Electronics
1734352-1
45
1
J102
Conn D-SUB Rcpt R/A
25 Pos 30 Gold (With
Threaded Inserts and
Board locks)
AMP/Tyco Electronics
5747846-4
46
1
J101
Conn D-SUB Plug R/A
25 Pos 30GOLD (With
Threaded Inserts and
Board locks)
AMP/Tyco Electronics
5747842-4
47
1
J8
Conn Header Low-Pro
60 Pos Gold
Assmann Electronics Inc
AWHW60G-0202-T-R
48
8
CH_ON,
CH_OFF, MBIT,
SPI_SCK,
SPI_CS, SPI_IO,
ONE, Vout,
GND_SEN
Connector
OMIT
OMIT
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Multi-Cal-System Evaluation Module
31
Bill of Materials
www.ti.com
Table 5. Multi-Cal-System EVM Board Parts List (continued)
32
No.
Qty
Ref Des
Description
Vendor
Part Number
49
4
JMP1, JMP2,
JMP4, JMP4
Header, 3 pos 0.100"
SGL Gold
Samtec
TSW-103-07-G-S
50
4
JMP1, JMP2,
JMP4, JMP5
Shunt LP w/handle 2
pos 30AU
Tyco Electronics
881545-2
51
1
T1
Terminal block 5 mm
3POS
ON SHORE TECHNOLOGY
ED300/3
52
1
T6
Terminal block 5 mm
2POS
ON SHORE TECHNOLOGY
ED300/2
53
16
M1-M8 and USB
DAQ Standoffs
(bottom)
Standoff Hex M/F 4-40
1.125"ALUM
Keystone Electronics
8406
54
16
M1-M8 and USB
DAQ Standoffs
(top)
Standoff Hex 4-40 Thr
alum .250"
Keystone Electronics
2201
55
6
Use on J0, J1, J9 Female Screwlock 4-40
.312"
Norcomp Inc.
SFSO4401NR
Multi-Cal-System Evaluation Module
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Revision History
www.ti.com
Revision History
Changes from Original (August, 2010) to A Revision .................................................................................................... Page
•
•
•
•
Updated Overview to include references to both PGA308 and PGA309 devices ............................................... 3
Revised description of Multi-Cal-Test PCA card to clarify that PGA309 version is not currently available ................... 5
Changed description of Recommended Starter System components to note that the Multi-Cal-System is compatible with
both PGA308 and PGA309. Added note (1) to Table 1 ............................................................................. 7
Moved Multi-Cal-System EVM Software Overview and Understanding the Instrument Script (Section 3 and Section 5,
respectively) to new document (SBOU104) ......................................................................................... 22
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
SBOU087A – August 2010 – Revised April 2011
Submit Documentation Feedback
Copyright © 2010–2011, Texas Instruments Incorporated
Revision History
33
Evaluation Board/Kit Important Notice
Texas Instruments (TI) provides the enclosed product(s) under the following conditions:
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the
product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are
not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations,
including product safety and environmental measures typically found in end products that incorporate such semiconductor
components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding
electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the
technical requirements of these directives or other related directives.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30
days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY
SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all
claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to
take any and all appropriate precautions with regard to electrostatic discharge.
EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.
TI assumes no liability for applications assistance, customer product design, software performance, or infringement of
patents or services described herein.
Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the
product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s
environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.
FCC Warning
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and
can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15
of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this
equipment in other environments may cause interference with radio communications, in which case the user at his own expense
will be required to take whatever measures may be required to correct this interference.
EVM Warnings and Restrictions
It is important to operate this EVM within the input voltage range of 5.7V to 9V and the output voltage range of 0V to 5V.
Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are
questions concerning the input range, please contact a TI field representative prior to connecting the input power.
Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the
EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load
specification, please contact a TI field representative.
During normal operation, some circuit components may have case temperatures greater than +25°C. The EVM is designed to
operate properly with certain components above +25°C as long as the input and output ranges are maintained. These components
include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of
devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near
these devices during operation, please be aware that these devices may be very warm to the touch.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and
Automotive
www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
Wireless
www.ti.com/wireless-apps
RF/IF and ZigBee® Solutions
www.ti.com/lprf
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
Similar pages