Littelfuse AK10-430C Transient voltage suppression diode Datasheet

Transient Voltage Suppression Diodes
Axial Leaded – 10kA > AK10 series
AK10 Series
RoHS
Pb
Description
The AK10 series of high current transient suppressors have
been specially designed for use in A.C. line protection and
any demanding applications (AC or DC).They offer superior
clamping characteristics over standard S.A.D. technologies
by virtue of the Littelfuse Foldbak technology, which
provides a clamping voltage lower than the avalanche
voltage (but above the rated working voltage). Therefore,
any voltage rise due to increased current conduction is
contained to a minimum, providing the best possible
protection level. They can also be connected in series and/
or parallel to create very high capacity protection solutions.
Agency Approvals
AGENCY
Features
AGENCY FILE NUMBER
• Halogen-Free
• RoHS compliant
• Foldbak technology for
superior clamping factor
• Glass passivated junction
• Bi-directional
E128662
Maximum Ratings and Thermal Characteristics
Parameter
Symbol
Value
Unit
Operating Junction and
Storage Temperature Range
TJ , TSTG
(-)55 to 150
°C
IPP
10
kA
Current Rating1
AK10 Series
(TA=25OC unless otherwise noted)
•Ultra compact: Less
than one-tenth the size
of traditional discrete
solutions
•Very Low Clamping
Voltage
• Sharp Breakdown Voltage
•Low Slope Resistance
Note:
1. Rated IPP measured with 8 x 20μs pulse.
Electrical Characteristics
Part
Numbers
AK10 - 058C
AK10 - 066C
AK10 - 076C
AK10 - 170C
AK10 - 190C
AK10 - 240C
AK10 - 380C
AK10 - 430C
Test
Max. Clamping Voltage Max. Temp
Max.
Max.
Standoff
Agency
Reverse Breakdown
Current VCL @ Peak Pulse Current Coefficient Capacitance Approval
Reverse
Voltage
Voltage (VBR) @ IT
IT
(IPP) (Note 1)
of VBR
0 Bias 10kHz
Leakage
(VSO)
Volts
(IR) @VSO µA
Min Volts Max Volts
(mA)
VCL Volts
IPP Amps
(%/OC)
(nF)
58
66
76
170
190
240
380
430
20
20
20
20
20
20
20
20
64
72
85
180
200
250
401
440
70
80
95
220
245
285
443
490
10
10
10
10
10
10
10
10
110
120
140
260
290
340
520
625
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
6.5
6.5
6.5
2.8
2.5
2.2
2.0
1.4
Note: Using 8 x 20µS wave shaped defined in IEC 61000-4-5.
AK10 Series
141
Revision: October 19, 2011, 16:35
©2011 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to http://www.Littelfuse.com/series/AK10.html for current information.
X
X
X
X
X
X
X
X
Transient Voltage Suppression Diodes
Axial Leaded – 10kA > AK10 series
Soldering Parameters
Lead–free assembly
Pre Heat
Ramp-up
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
200°C
- Time (min to max) (ts)
60 – 180 secs
TL
Average ramp up rate (Liquidus Temp
(TL) to peak
3°C/second max
TS(max) to TL - Ramp-up Rate
3°C/second max
Reflow
tp
TP
Temperature (T)
Reflow Condition
Ts(max)
Ts(min)
217°C
- Time (min to max) (ts)
60 – 150 seconds
Ramp-down
ts
Preheat
25˚C
- Temperature (TL) (Liquidus)
t 25˚C to Peak
Time (t)
Peak Temperature (TP)
260+0/-5 °C
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Flow/Wave Soldering (Solder Dipping)
Ramp-down Rate
6°C/second max
Peak Temperature :
265OC
Time 25°C to peak Temperature (TP)
8 minutes Max.
Dipping Time :
10 seconds
280°C
Soldering :
1 time
Do not exceed
Critical Zone
TL to TP
tL
Physical Specifications
Weight
Contact manufacturer
Case
Epoxy encapsulated
Terminal
Silver plated leads, solderable per
MIL-STD-202 Method 208
Ratings and Characteristic Curves (T =25°C unless otherwise noted)Peak Power Derating
A
Peak Power Derating
Percent of Rated Value
120
100
80
60
40
20
0
0
25
50
75
100
125
150
AMBIENT TEMPERATURE (°C)
AK10 Series
142
Revision: October 19, 2011, 16:35
©2011 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to http://www.Littelfuse.com/series/AK10.html for current information.
Transient Voltage Suppression Diodes
Axial Leaded – 10kA > AK10 series
Dimensions
Dimensions
A
G
L2
F
L1
D
B
E
C
Part Marking System
Inches
Millimeters
A
0.950
24.15
B
0.095
2.4
C - 058C/066C/076C
0.236
6.00
C
0.145
3.68
D
0.570 max.
14.48 max.
E
0.050
1.270
F
0.500 max.
12.70 max.
G - 058C/066C/076C
0.200
5.08
G - 170C/190C
0.362
9.2
G - 240C
0.420
10.67
G - 380C/430C
0.650
16.50
L1
0.310
7.87
L1 - 380C/430C
0.177
4.5
L2= A - (G+L1) tolerance +/- 0.04 inch (1.0 mm)
Part Numbering System
Date Code
AK10 XXXX
Littelfuse Logo
AK10-xxxx
XX
Series Type
LF
Stand Off Voltage
(Please Refer to Electrical
Characteristics Chart)
Product Type
AK10 Series
AK10 Series
Note: UL mark does not appear on -058C & -066C & -076C.
143
Revision: October 19, 2011, 16:35
©2011 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to http://www.Littelfuse.com/series/AK10.html for current information.