AIMTEC AM5E-4803S-FZ 5 watt | dc-dc converter Datasheet

Series AM5E-FZ
5 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
AM5E-1203S-FZ
AM5E-1205S-FZ
AM5E-1212S-FZ
AM5E-1215S-FZ
AM5E-2403S-FZ
AM5E-2405S-FZ
AM5E-2412S-FZ
AM5E-2415S-FZ
AM5E-4803S-FZ
AM5E-4805S-FZ
AM5E-4812S-FZ
AM5E-4815S-FZ
Input
Voltage (V)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
Models
Dual output
Model
Input
Voltage (V)
Over Load, Over Voltage Protection
Wide 2:1 input range
High efficiency up to 87%
Pin compatible with multiple manufacturers
• Operating temperature -55oC to + 85oC
• Input / Output Isolation 1500 VDC
• Continuous short circuit protection
Output
Voltage
(V)
Minimum
Load
Current (mA)
Output Current
max (A)
Capacitance
load, max (μF)
Efficiency
(%)
20
0
0
0
20
0
0
0
20
0
0
0
1.5
1.0
0.416
0.333
1.5
1.0
0.416
0.333
1.5
1.0
0.416
0.333
4700
2200
330
220
4700
2200
330
220
4700
2200
330
220
78
80
85
85
79
82
86
87
77
82
85
86
Output
Voltage
(V)
Minimum
Load
Current (mA)
Output Current
max (A)
Capacitance
load, max
(μF)
Efficiency
(%)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
AM5E-1205D-FZ
9-18
±5
57
±0.5
1100
82
AM5E-1212D-FZ
9-18
±12
0
±0.208
100
84
AM5E-1215D-FZ
9-18
±15
0
±0.167
69
85
AM5E-2405D-FZ
18-36
±5
57
±0.5
990
83
AM5E-2412D-FZ
18-36
±12
0
±0.208
122
86
AM5E-2415D-FZ
18-36
±15
0
±0.167
147
87
AM5E-4805D-FZ
36-72
±5
57
±0.5
1000
82
AM5E-4812D-FZ
36-72
±12
0
±0.208
220
86
AM5E-4815D-FZ
36-72
±15
0
±0.167
13
86
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5E-FZ
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
No Load Input Current
Input reflected current
Transient recovery deviation
Transient response time
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Over load protection
Over Voltage Protection
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
www.aimtec.com
F 051e R12
5 Watt | DC-DC Converter
Nominal
Typical
12
24
48
Maximum
9-18
18-36
36-72
VDC
π(PI )
400
-0.7-25
-0.7-50
-0.7-100
12 Vin
24 Vin
48 Vin
ms
VDC
100
<3
250
±5
300
50% load step
change
Conditions
Typical
3 sec
Rated
> 1000
580
24 Vin
Conditions
Typical
±1
20MHz Bandwidth
Conditions
300
-55 to +125
Units
VDC
MOhm
pF
Maximum
Units
150
Zener Diode Clamp
±0.5
±0.5
±0.5
±5
±0.02
75
Typical
ms
mA
mAp-p
%of Vout
µs
1500
Continuous
Auto Recovery
LL-HL
25-100%
10-100% Balanced
25-100% Unbalanced
Units
%
%
%
%
%
% oC
mVp-p
Maximum
-55 to +85
100
Units
KHz
o
C
o
C
o
C
Free air convection
95
%
Nickel coated copper
30
g
Tolerance ±0.5mm
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.20 mm
>1,960,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
o
1.5mm from case max 10 sec
260
C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5E-FZ
5 Watt | DC-DC Converter
Pin Out Specifications
Pin
Single
1
2
3
4
5
+V Input
-V Input
+V Output
No Pin.
-V Output
Dual
+V Input
-V Input
+V Output
Common.
-V Output
2.54
(0.10)
Dimensions
50.80
(2.00)
20.32
(0.80)
15.24
(0.60)
10.16
(0.40)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
5.08
(0.20)
Min
10.20
(0.40)
DIA
1.00
(0.04)
5
15.24
(0.60)
Built-in Stand-offs to
ease PCB cleaning
4
10.16
(0.40)
10.16
(0.40)
2
Bottom View
2.54
(0.10)
1
5.08
(0.20)
25.40
(1.00)
10.16
(0.40)
3
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only