2016-V1.0-1102 Specifications Constant Current LED Power Supplies LXU-30C Series, 30W PAIRUI ELECTRONICS No. 545 Museum Road Yangzhou, Jiangsu China 225009 Tel: 86 (514) 8279 1592 Fax: 86 (514) 8769 3159 2016 led power supplies PRODUCT SPECIFICATION LED Power Supplies for Indoor Use LXU-30C SERIES, 30WATT, IP20 RATING Features 3 Year Warranty Universal Input Voltage Range: 100~240Vac Constant Current Output Mode Waterproof Rating IP20 Built-in Active Power Factor Correction Class II Power, no FG Short Circuit, and Over Temperature Protections Applications √ Panel Light √ Down Light √ Cabinet Light √ Other Indoor used Lights √ Recessed Light Electrical LX U 30 - C 700 R ST Strain ReliefSet Flicker Blank = Default Models R = No Flicker Output Current(mA) Output Mode C = Constant Current Mode Output Power(W) Input Voltage Range U = 100-240Vac Series Name PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:1/6 led power supplies PRODUCT SPECIFICATION Electrical PartNumber Nominal Input Voltage Output Current Output Voltage No Load Output Voltage Ripple Efficiency Certificate LXU30-C350 100-240VAC 350mA(60-86V) 94V 5%/50% 90% CE LXU30-C500 100-240VAC 500mA(42-60V) 66V 5%/50% 90% CE LXU30-C700 100-240VAC 700mA(30-43V) 47V 5%/50% 88% CE LXU30-C1050 100-240VAC 1050mA(20-29V) 32V 5%/50% 86% CE NOTE: 1. Other output models are may available on request; 2. Add suffix “R” for No Flicker and Low Ripple(5%) models. PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:2/6 led power supplies PRODUCT SPECIFICATION INPUT PARAMETER CONDITIONS Input frequency MIN TYP 47 Input current Fullload,Vin=110Vac Full load, Vin=220Vac Inrush current Cold start, Vin=230Vac Power factor(PF) Full load, Vin=110Vac Full load, Vin=220Vac Surge voltage L-N MAX 63 UNITS Hz A A 0.38 0.19 25 A 0.96 0.94 2 KV PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:3/6 led power supplies PRODUCT SPECIFICATION OUTPUT PARAMETER CONDITIONS Output current accuracy MIN TYP MAX UNITS ±5 % Line regulation Vin from 100Vac to 240Vac 3 % Load regulation Vout from min. to max. 3 % Output current overshoot Turning on Turn-on delay time Cold start, power on 1000 ms Ripple (Refer to below note) DefaultModels No Flicker(with suffix “R”) 50%Io 5%Io mAp-p mAp-p THD Output load≥60% % 10 % 20 NOTE: The values are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with 0.1uF & 47uF parallel capacitor under ambient temperature 25℃ at rated input voltage and rated load. Protection Short circuit In hiccup mode, it will recover automatically after fault condition is removed Over temperature 120℃-160℃ It will recover automatically after the temperature goes down PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:4/6 led power supplies PRODUCT SPECIFICATION Environment PARAMETER CONDITIONS MIN Ambient operating temperature Startup at rated voltage Operating relative humidity TYP MAX UNITS -25 +70 ℃ Non condensing 20 90 % Storagetemperature Humidity 10 ~ 95% RH - 40 + 80 ℃ Maximum case temperature Hot-spotoncase + 75 ℃ MTBF Fullload, 220Vac input, 25℃ambient temperature Waterproof rating IP20 Dimension(LxWxH) 97.0 x 43.0 x 30.0mm Weight 250g 230 Khrs Safety/EMC Safety Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 NOTE: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25℃andVin=100Vac to 240Vac. PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:5/6 PRODUCT SPECIFICATION led power supplies Mechanical 30 43 97 Unit: mm Electrical Curve DERATING CURVE 100 90 Load(%) 80 70 60 50 40 30 -25 -15 0 10 20 30 40 50 60 70 Temperature(℃) PAIRUI ELECTRONICS www.pairuigroup.com Updated 2016-V1.0-1102 Page:6/6